Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “BEAM MONITORING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Track Matching in the DUNE Near Detectors

The Deep Underground Neutrino Experiment (DUNE) is an international particle physics experiment looking answer some of the largest unanswered questions in neutrino physics. DUNE uses a high power neutrino beam produced at Fermi National Accelerator Laboratory (Fermilab), and consists of a near detector (ND) also located at Fermilab and a far detector (FD) 1300 km away at the Sanford Underground Research Facility (SURF) in South Dakota. In the first phase of the experiment, the ND complex will contain a modular liquid argon TPC (ND-LAr) and a solid scintillator-based muon spectrometer (TMS), in addition to a beam monitoring detector (SAND) and systems for moving ND-LAr and TMS away from the neutrino beam axis (PRISM). A prototype of ND-LAr, the 2x2 demonstrator, alongside a solid scintillator muon tagger provided by repurposed MINERvA planes, has been built and taken data at Fermilab. For analyses with the ND, connecting particle tracks (such as muons) that exit the liquid argon active volume into the solid scintillator muon detector can improve particle identification and energy reconstruction, and alleviate pileup due to the intense beam. To match tracks between detectors during reconstruction, we have explored using Graph Neural Networks (GNNs) to connect tracks segments between the liquid argon detector region and the solid scintillator detector planes. We have trained a GNN on reconstructed simulated data from the 2×2 demonstrator and repurposed MINERvA planes. We will evaluate its performance and then train a similar network on reconstructed ND-LAr and TMS simulations.

Xing, Daniel [U. Colorado, Boulder]↗

Fast Beam Tuning for Accelerator Driven Systems

The biggest challenge for Accelerator Driven Systems (ADS) is the stringent availability requirement of >99% compared to ~80% achieved by a typical accelerators. In addition to overall availability, due to thermal stress problems, ADS is also sensitive to the length of each downtime. A significant source of downtime is re-adjustment tuning of the system to account for drift in component behavior, or substitution of a backup device for one that failed. Tuning at present is done by hand, i.e. with human observation, interpretation, and decision, a process which takes hours; whereas ADS requires recovery in minutes. In this research, we apply intelligent controls in a (simulated) proton linac to automate fine-tuning. Beam monitor data is fed into a controller which adjusts magnet currents and RF power to minimize beam loss. We consider fluctuations in ion source characteristics; drift in magnet behavior (mechanical motion, or change in calibration); and failure of an accelerating cavity.

43 PARTICLE ACCELERATORS↗

Design and Analysis of a Single-Shot Longitudinal Phase Space Measurement Diagnostics at the Argonne Wakefield Accelerator

A single-shot longitudinal phase space diagnostics is currently being assembled at the Argonne Wakefield Accelerator (AWA). The diagnostics consists of mapping the longitudinal phase space coordinates to the transverse position space plane using a beamline that incorporates two magnetic dipoles arranged as a dogleg followed by an rf deflecting cavity. The deflecting cavity streaks the beam vertically while the dipole magnets bend horizontally. In this paper, we analyze analytically and via numerical simulations the performances of such diagnostics and their limitations. Simulations done in IMPACT-T shows good reconstruction of the longitudinal phase space.

43 PARTICLE ACCELERATORS↗

Extending Electro-Optic Detection of Short Particle Beams Beyond the Transverse Phonon Resonance

A technique to noninvasively measure the longitudinal profile of an ultrashort charged particle beam is developed. This technique is based on three-wave mixing of the particle beam's self-fields and an optical probe in a nonlinear material. The resulting mixed field is then diagnosed by a cross-correlating frequency resolved optical gate, which provides both frequency and phase information about the generated pulse from which, in principle, the temporal profile can be reconstructed. An equation for the generated fields as well as numerical results showing the effects of a chirped probe pulse are presented.

43 PARTICLE ACCELERATORS↗

Transverse-to-Longitudinal Phase Space Exchange: a Versatile Tool for Shaping the Current and Energy Profiles of Relativistic Electron Bunches

Over the recent years, the emergence of accelerator beamlines capable of exchanging the phase space coordinates between two degrees of freedom has opened the path toward the precise control of phase space distribution and in particular to the production of relativistic electron beams with shaped current profiles. After briefly reviewing the technique, we present its application to produce a train of sub-picosecond microbunches and report on its experimental implementation at the Fermilab's A0 photoinjector facility.

43 PARTICLE ACCELERATORS↗

Development of a novel bunch oscillation recorder with RFSoC technology

The SuperKEKB accelerator is designed to achieve unprecedented luminosity levels, but this goal is currently hindered by Sudden Beam Loss (SBL) events. These events not only obstruct luminosity improvement but also pose a significant risk to accelerator components, the Belle II detectors, and the superconducting focusing system, potentially leading to severe damage and quenching of the superconducting system. Here, to address this critical challenge, we have developed a novel Bunch Oscillation Recorder (BOR) based on RFSoC technology. The BOR has demonstrated high precision with a position resolution of 0.03 mm, making it a powerful tool for real-time beam monitoring. In its initial deployment, the BOR successfully recorded multiple SBL events, providing valuable data for further analysis. By strategically positioning BORs at the suspected points of SBL origin, we aim to directly identify sources of beam instability. We anticipate that this portable, high-speed BOR monitor will play a crucial role in resolving the SBL issue, ultimately helping achieve SuperKEKB's luminosity targets.

Beam diagnostics↗

Vacuum system of the compact Energy Recovery Linac

The compact Energy Recovery Linac (cERL), a test accelerator to establish important technologies demanded for future ERL-based light sources, was constructed in late 2013 at KEK. The accelerator was successfully commissioned in early 2014, and demonstrated beam circulation with energy recovery. In the cERL vacuum system, low-impedance vacuum components are required to circulate high-intensity, low-emittance and short-bunch electron beams. We therefore developed ultra-high-vacuum (UHV)-compatible flanges that can connect beam tubes seamlessly, and employed retractable beam monitors, namely, a movable Faraday cup and screen monitors. In most parts of the accelerator, pressures below 1×10{sup −7} Pa are required to mitigate beam-gas interactions. Particularly, near the photocathode electron gun and the superconducting (SC) cavities, pressures below 1×10{sup −8} Pa are required. The beam tubes in the sections adjoining the SC cavities were coated with non-evaporable getter (NEG) materials, to reduce gas condensation on the cryo-surfaces. During the accelerator commissioning, stray magnetic fields from the permanent magnets of some cold cathode gauges (CCGs) were identified as a source of the disturbance to the beam orbit. Magnetic shielding was specially designed as a remedy for this issue.

43 PARTICLE ACCELERATORS↗

A method for online verification of adapted fields using an independent dose monitor

Purpose: Clinical implementation of online adaptive radiotherapy requires generation of modified fields and a method of dosimetric verification in a short time. We present a method of treatment field modification to account for patient setup error, and an online method of verification using an independent monitoring system.Methods: The fields are modified by translating each multileaf collimator (MLC) defined aperture in the direction of the patient setup error, and magnifying to account for distance variation to the marked isocentre. A modified version of a previously reported online beam monitoring system, the integral quality monitoring (IQM) system, was investigated for validation of adapted fields. The system consists of a large area ion-chamber with a spatial gradient in electrode separation to provide a spatially sensitive signal for each beam segment, mounted below the MLC, and a calculation algorithm to predict the signal. IMRT plans of ten prostate patients have been modified in response to six randomly chosen setup errors in three orthogonal directions.Results: A total of approximately 49 beams for the modified fields were verified by the IQM system, of which 97% of measured IQM signal agree with the predicted value to within 2%.Conclusions: The modified IQM system was found to be suitable for online verification of adapted treatment fields.

61 RADIATION PROTECTION AND DOSIMETRY↗

The MANX Muon Cooling Experiment Detection System

The MANX experiment is being proposed to demonstrate the reduction of 6D muon phase space emittance, using a continuous liquid absorber to provide ionization cooling in a helical solenoid magnetic channel. The experiment involves the construction of a two-period-long helical cooling channel (HCC) to reduce the muon invariant emittance by a factor of two. The HCC would replace the current cooling section of the MICE experiment now being set up at the Rutherford Appleton Laboratory. The MANX experiment would use the existing MICE spectrometers and muon beam line. We discuss the placement of detection planes to optimize the muon track resolution.

43 PARTICLE ACCELERATORS↗

Capability Improvements at Marshall Space Flight Center's X-Ray and Cryogenic Facility

The X-Ray & Cryogenic Facility (XRCF) at Marshall Space Flight Center is the world’s largest x-ray optic calibration facility and NASA’s premier cryogenic optical test facility. Built specifically to calibrate the Chandra telescope, the facility contributed to several other x-ray missions until 2005 when it became dedicated to normal incidence optical testing at cryogenic temperatures. Recently the facility’s x-ray test capability has been returned to service and updated. New beam monitors, focal plane detectors, and test article and instrument positioning systems have been added. The x-ray data acquisition system has been updated. A real-time position monitoring metrology system is being developed that will enable calibration of large diameter optics via partial illumination in a diverging beam. The newly expanded x-ray test capabilities of the facility will be discussed.

XRCF↗

Acceleration Mechanism Of Pulsed Laser-Electromagnetic Hybrid Thruster

A fundamental study of a newly developed rectangular pulsed laser-electromagnetic hybrid thruster was conducted. Laser-ablation plasma in the thruster was induced through laser beam irradiation onto a solid target and accelerated by electrical means instead of direct acceleration only by using a laser beam. The performance of the thrusters was evaluated by measuring the ablated mass per pulse and impulse bit. As results, significantly high specific impulses up to 7,200 s were obtained at charge energies of 8.6 J. Moreover, from the Faraday cup measurement, it was confirmed that the speed of ions was accelerated with addition of electric energy.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Polarized Beams at EICs

Designs of future electron-ion colliders (EIC) are presently under development at BNL and TJNAF. Polarized beams of electrons, protons and light ions are essential feature of those designs. The talk reviews approaches and techniques used in the EIC designs for delivering high-energy polarized beams and describes existing challenges.

43 PARTICLE ACCELERATORS↗

Multiple Spin Resonance Crossing in Accelerators

In this paper the method of beam depolarization compensation during spin resonance crossing is developed. This method is based on the restoration of the spin adiabatic invariant after the spin resonance crossing. The case when the restoration of spin adiabatic invariant occurs due to multiple crossing of the resonance effective area is considered. At the same time it is necessary to provide the certain difference of spin phases between the moments of crossing of the resonance effective area. The conditions of beam polarization preservation when the resonance effective area is repeatedly crossed are obtained. Numerical examples are presented.

43 PARTICLE ACCELERATORS↗

Study of the one-way speed of light anisotropy with particle beams

Concepts of high precision studies of the one-way speed of light anisotropy are discussed. The high energy particle beam allows measurement of a one-way speed of light anisotropy (SOLA) via analysis of the beam momentum variation with sidereal phase without the use of synchronized clocks. High precision beam position monitors could provide accurate monitoring of the beam orbit and determination of the particle beam momentum with relative accuracy on the level of 10^-10, which corresponds to a limit on SOLA of 10^-18 with existing storage rings. A few additional versions of the experiment are also presented.

Wojtsekhowski, Bogdan B.↗

SPINK, A Thin Elements Spin Tracking Code

Spink is a spin tracking code for spin polarized particles. The code tracks both trajectories in 3D and spin. It works using thick element modeling from MAD and thin element modeling based on the BMT equation to track spin. The code is written in Fortran and typically runs on a Linux platform, either sequentially or MPI-parallel.

43 PARTICLE ACCELERATORS↗

Method and apparatus for real time imaging and monitoring of radiotherapy beams

A method and apparatus for real time imaging and monitoring of radiation therapy beams is designed to preferentially distinguish and image low energy radiation from high energy secondary radiation emitted from a target as the result of therapeutic beam deposition. A detector having low sensitivity to high energy photons combined with a collimator designed to dynamically image in the region of the therapeutic beam target is used.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-D-213-01: Transparent Photon Detector For The Online Monitoring Of IMRT Beams

Purpose: An innovative Transparent Detector for Radiotherapy (TraDeRa) has been developed. The detector aims at real-time monitoring of modulated beam ahead of the patient during delivery sessions, with a field cover up to 40×40 cm {sup 2}. Methods: TraDeRa consists in a pixelated matrix of ionization chambers with a patented electrodes design. An in-house designed specific integrated circuit allows to extract the signal and provides a real-time map of beam intensity and shape, at the linac pulse-scale. The measurements under irradiation are made with a 6 MV clinical X-Ray beam. Dose calculations are performed with the Monte Carlo code PENELOPE, modeling the full accelerator head and the TraDeRa detector. Results: A 2 % attenuation of the beam was measured in the presence of TraDeRa and the PENELOPE dosimetric study showed no significant modification of the photon beam properties. TraDeRa detects error leaf position as small as 1 mm compared to a reference field, for both static and modulated fields. In addition, measurements are accurate over a large dynamic range from low intensity signals, as inter-leaves leaks, to very high intensities as obtained on the medical line of the European Synchrotron Radiation Facility. The detector is fully operational for conventional and high dose rate beams as FFF modes (up to 2400 MU/min). Conclusion: The current version of TraDeRa shows promising results for IMRT quality assurance (QA), allowing pulse-scale monitoring of the beam and high sensitivity for errors detection. The attenuation is small enough not to hinder the irradiation while keeping the beam upstream of the patient under constant control. A final prototype under development will include 1600 independent electrodes, half of them with a high resolution centered on the beam axis. This compact detector provides an independent set of measurements for a better QA. Funding support : This work was supported by the LABEX PRIMES (ANR-11-LABX-0063) of Universite de Lyon, within the program “Investissements d’Avenir” (ANR-11-IDEX-0007) operated by the French National Research Agency (ANR) and within the project “INSPIRA” operated by the OSEO institution.

60 APPLIED LIFE SCIENCES↗

Operational Performance of LCLS Beam Instrumentation

The Linac Coherent Light Source (LCLS) X-ray FEL utilizing the last km of the SLAC linac has been operational since April 2009 and finished its first successful user run last December. The various diagnostics for electron beam properties including beam position monitors, wire scanners, beam profile monitors, and bunch length diagnostics are presented as well as diagnostics for the X-ray beam. The low emittance and ultra-short electron beam required for X-ray FEL operation has implications on the transverse and longitudinal diagnostics. The coherence effects of the beam profile monitors and the challenges of measuring fs long bunches are discussed.

43 PARTICLE ACCELERATORS↗