Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Angular Reference”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Emittance growth due to multiple passes through H-minus stripping foil in Booster

Expressions for transverse emittance growth due to turn-by-turn passes through the H-minus stripping foil in Booster are developed here from simple principles of statistics and simple assumptions about the initial distribution of particles incident on the foil. These are meant to complement work already presented by Zeno [1, 2, 3] and Brown [4]. The expressions show that while the average emittance hEi of the distribution simply increases linearly with turn number, the emittance E based on the mean square particle position does so with an additional oscillatory term that depends on the machine tune. It is shown that this term can be ignored as long as the turn number is su ciently large and the tune is su ciently far from integer and half-integer values. Under these conditions the relation between hEi and E is simply hEi = 2 E. This relation is shown to hold for a Gaussian distribution that is matched to the machine lattice. Two symmetry conditions which help characterize the particle distribution are identi ed. These provide justi cation for calling E an emittance. It is shown that if the conditions are satis ed by the initial distribution, they will not be satis ed after a single traversal of the foil and one turn around the machine. However, on subsequent turns the distribution can (and does) return to satisfying the conditions. Moreover, for su ciently large turn number, the symmetry conditions are approximately satis ed. As already noted in [4], the emittance growth per turn is proportional to the lattice beta at the foil and the mean square angular kick received by protons passing through the foil. We take the former to be 5 m. The latter is obtained from simulations performed with the code TRIM [5]. Having these numbers in hand, actual numbers for emittance growth are presented. The reader may wish to start with Section 11 and refer to previous sections as needed or desired.

43 PARTICLE ACCELERATORS↗

Slew maneuver dynamics of the Spacecraft Control Laboratory experiment

Mathematical expressions for slew maneuver dynamics are presented. The total kinetic energy expression of the system is given as T = T(0) + T(1) + T(2), where T(0), T(1), and T(2) refer to the kinetic energies of the shuttle, the flexible beam, and the tip mass (the reflector), respectively. The specific equations for each of these are defined and integrated into the total energy expression. Using the chain rule in the Lagrange equations and an expression allowing the transformation of the orbiter angular velocity from the inertial frame to the body-fixed frame, the rotational equations are obtained. Finally, the vibration equations for the beam are derived, again using the Lagrange equations.

Kakad, Y. P.↗

Conformal image-guided microbeam radiation therapy at the ESRF biomedical beamline ID17

Purpose: Upcoming veterinary trials in microbeam radiation therapy (MRT) demand for more advanced irradiation techniques than in preclinical research with small animals. The treatment of deep-seated tumors in cats and dogs with MRT requires sophisticated irradiation geometries from multiple ports, which impose further efforts to spare the normal tissue surrounding the target. Methods: This work presents the development and benchmarking of a precise patient alignment protocol for MRT at the biomedical beamline ID17 of the European Synchrotron Radiation Facility (ESRF). The positioning of the patient prior to irradiation is verified by taking x-ray projection images from different angles. Results: Using four external fiducial markers of 1.7 mm diameter and computed tomography-based treatment planning, a target alignment error of less than 2 mm can be achieved with an angular deviation of less than 2{sup ∘}. Minor improvements on the protocol and the use of smaller markers indicate that even a precision better than 1 mm is technically feasible. Detailed investigations concerning the imaging dose lead to the conclusion that doses for skull radiographs lie in the same range as dose reference levels for human head radiographs. A currently used online dose monitor for MRT has been proven to give reliable results for the imaging beam. Conclusions: The ESRF biomedical beamline ID17 is technically ready to apply conformal image-guided MRT from multiple ports to large animals during future veterinary trials.

60 APPLIED LIFE SCIENCES↗

The Berkeley extreme ultraviolet calibration facility

The vacuum calibration facilities of the Space Sciences Laboratory, University of California at Berkeley are designed for the calibration and testing of EUV and FUV spaceborne instrumentation (spectral range 44-2500 A). The facility includes one large cylindrical vacuum chamber (3 x 5 m) containing two EUV collimators, and it is equipped with a 4-axis manipulator of angular-control resolution 1 arcsec for payloads weighing up to 500 kg. In addition, two smaller cylindrical chambers, each 0.9 x 1.2 m, are available for vacuum and thermal testing of UV detectors, filters, and space electronics hardware. All three chambers open into class-10,000 clean rooms, and all calibrations are referred to NBS secondary standards.

Welsh, Barry Y.↗

Video Meteor Fluxes

The flux of meteoroids, or number of meteoroids per unit area per unit time, is critical for calibrating models of meteoroid stream formation and for estimating the hazard to spacecraft from shower and sporadic meteors. Although observations of meteors in the millimetre to centimetre size range are common, flux measurements (particularly for sporadic meteors, which make up the majority of meteoroid flux) are less so. It is necessary to know the collecting area and collection time for a given set of observations, and to correct for observing biases and the sensitivity of the system. Previous measurements of sporadic fluxes are summarized in Figure 1; the values are given as a total number of meteoroids striking the earth in one year to a given limiting mass. The Gr n et al. (1985) flux model is included in the figure for reference. Fluxes for sporadic meteoroids impacting the Earth have been calculated for objects in the centimeter size range using Super-Schmidt observations (Hawkins & Upton, 1958); this study used about 300 meteors, and used only the physical area of overlap of the cameras at 90 km to calculate the flux, corrected for angular speed of meteors, since a large angular speed reduces the maximum brightness of the meteor on the film, and radiant elevation, which takes into account the geometric reduction in flux when the meteors are not perpendicular to the horizontal. They bring up corrections for both partial trails (which tends to increase the collecting area) and incomplete overlap at heights other than 90 km (which tends to decrease it) as effects that will affect the flux, but estimated that the two effects cancelled one another. Halliday et al. (1984) calculated the flux of meteorite-dropping fireballs with fragment masses greater than 50 g, over the physical area of sky accessible to the MORP fireball cameras, counting only observations in clear weather. In the micron size range, LDEF measurements of small craters on spacecraft have been used to estimate the flux (Love & Brownlee, 1993); here the physical area of the detector is well known, but the masses depend strongly on the unknown velocity distribution. In the same size range, Thomas & Netherway (1989) used the narrow-beam radar at Jindalee to calculate the flux of sporadics. In between these very large and very small sizes, a number of video and photographic observations were reduced by Ceplecha (2001). These fluxes were calculated (details are given in Ceplecha, 1988) taking the Halliday et al. (1984) MORP fireball fluxes, slightly corrected in mass, as a calibration, and adjusting the flux of small cameras to overlap with the number/mass relation from that work.

Campbell-Brown, M. D.↗

A comparison of Monte Carlo fission models for safeguards neutron coincidence counters

Monte Carlo simulation is a powerful tool used to model neutron coincidence detectors for international safeguards. The simulation has typically sampled properties such as the fission neutron multiplicity, energy, and direction, from independent probability density functions. However, multiplicity counters detect event-based neutron correlations and thus more accurate fission event modeling is needed. To respond to this need, the Fission Reaction Event Yield Algorithm (FREYA) and the Cascading Gamma-ray Multiplicity with Fission (CGMF) models were added in the newest version of MCNP, MCNP6.2. The models simulate individual fission events conserving momentum, energy, and angular momentum such that correlated particles are emitted. The effects of the new models on simulations of safeguards neutron coincidence counters were studied and compared to standard MCNP simulations. The MCNPX-PoliMi model was also included in the comparison. The properties of fission neutrons from safeguards relevant isotopes were compared to literature references. Then a hypothetical simplified detector was modeled to isolate the effects of specific differences between models. Experimental measurements from previous work were modeled and agreements were compared. Lastly, the probabilities of correlated events occurring in the experimental measurements were calculated with the different models. For example, the probability was calculated of detecting neutrons from both induced fission in uranium and spontaneous fission of Cf-252 in the same fission chain.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Pressure suit joint analyzer

A measurement system for simultaneously measuring torque and angular flexure in a pressure suit joint is described. One end of a joint under test is held rigid. A torque transducer is pivotably supported on the other movable end of a joint. A potentiometer is attached to the transducer by an arm. The wiper shaft of the potentiometer is gripped by a reference arm that rotates the wiper shaft the same angle as the flexure of joint. A signal is generated by the potentiometer which is representative of the joint flexure. A compensation circuit converts the output of the transducer to a signal representative of joint torque.

Vykukal, H. C.↗

Solar Probe - System concepts and requirements

The design and related constraints relevant to the development of the Solar Probe are examined with reference to the environmental conditions and mission trajectory. The science-related requirements of the Solar Probe mission include instruments with 360-deg sweep on a platform that spins at 60 rpm and carries a magnetometer on a boom. The mission trajectory of a 4-solar-radii perihelion is designed to eliminate angular velocity about the sun, and the unusual requirements of dense interplanetary dust and enhanced gamma-ray radiation are mentioned. A list of specific functional requirements that directly affect the system configuration is given which includes those for the high-gain antenna and the main shield. These requirements are translated into a full-science-scope spacecraft design, and specific mass and power estimates are given. Reduced-scope and baseline configurations are also presented that allow good scientific return with significantly reduced development costs.

Gronroos, H. G.↗

Delimitation of terrestrial impact craters by way of pseudotachylytic rock distribution

The determination of the shape and size of terrestrial impact craters is problematic, yet is critical to understanding cratering mechanics and for scaling bolide mass, volume, and impact velocity with crater size and target response. The problem is particularly difficult in older geological terrains (e.g. Precambrian) which are more likely to have suffered post-impact deformation and hence distortion of the original structure and/or where weathering may have partly removed or obscured its original shape. Traditionally, a number of features are used to assist us in determining the shape and size of an impact structure. These include the following: (1) the occurrence of faults, especially those disposed concentrically relative to the crater--the outermost ring faults being interpreted as indicating a viable minimum diameter; and (2) the development of so-called breccias, some of which are also associated with faults (e.g. the Sudbury Breccia developed within the target rocks of the Sudbury Structure of Onta rio, Canada). 'Breccia' is not a satisfactory term because a number of breccia-types exist at impact sites (e.g. fall-back breccias and in-situ brecciated target material). Of relevance to crater diameter determination is the recognition of discrete zones and fault- and shock-related pseudotachylyte. Pseudotachylyte is a rock type comprising a fine-grained, usually dark matrix containing clasts of minerals and/or rock derived from the country rock target material. It origin is normally attributed to high-speed slip (including vibration) along a slip surface (i.e. fault) or to the passage of a shock wave through the host material. The clasts can occur as angular fragments (i.e. like a breccia), but are more commonly developed as rounded to sub-rounded fragments. Significantly, the scale of these pseudotachylytes can range from sub-millimeter thick veinlets to dyke-like bodies up to 1 km or more thick. It is the latter, larger occurrence which has been referred to as 'breccia.' The smaller-sized occurrence is generally not recognized in the field, nor is it traditionally associated with its larger counterpart.

Spray, John G.↗

Spectral Irradiance Calibration in the Infrared: 3-35 microns Spectra of Three Southern Standard Stars - Part 6

We present three new absolutely calibrated continuous stellar spectra from 3 to 35 microns, constructed as far as possible from actual observed spectral fragments taken from the Kuiper Airborne Observatory (KAO), and the IRAS Low Resolution Spectrometer (LRS). These stars- alpha(sup 1) Cen, alpha TrA, and epsilon Car-augment our previous archive of complete absolutely calibrated spectra for northern K and M giants. All these spectra have a common calibration pedigree. The wavelength coverage is ideal for calibration of many existing and proposed ground-based, airborne, and satellite sensors. KAO and IRAS data in the 15-30 micron range suggest that the spectra of cool giants are close to Rayleigh-Jeans slopes. Our observations of alpha(sup 1) Cen, absolutely calibrated via our adopted Sirius model, indicate an angular diameter in very good agreement with values in the literature, demonstrating 'closure' of the set of spectra within our absolute framework. We compare our observed alpha(sup 1) Cen spectrum with a published grid of theoretical models from Kurucz, and adopt a plausible theoretical shape, that fits our spectrum, as a secondary reference spectrum in the southern sky.

Cohen, Martin↗

As the World Turns: Everything You Wanted to Know about Earth's Rotation

Earth's rotation vector is not a constant in space. Rather, it varies slightly with time on all temporal scales in a very complex, but interesting way. Phenomenologically, the variation can be considered separately in terms of (1) variations in the rotational speed (which translates into the length of day); and (2) variations in the orientation of the rotation axis (called the polar motion relative to the Earth reference frame, and the nutations relative to the inertial space). From the dynamics point of view, these changes can be separated into two types: astronomical (due to external torques mostly exerted by Moon and Sun), and geophysical (due to mass transport in the geophysical fluids of the Earth system under the conservation of angular momentum). Interesting and significant phenomena result. Decades of advancing measurements and active research have yielded fascinating stories.

Chao, Benjamin F.↗

Optical Alignment of the Global Precipitation Measurement (GPM) Star Trackers

The optical alignment of the star trackers on the Global Precipitation Measurement (GPM) core spacecraft at NASA Goddard Space Flight Center (GSFC) was challenging due to the layout and structural design of the GPM Lower Bus Structure (LBS) in which the star trackers are mounted as well as the presence of the star tracker shades that blocked line-of-sight to the primary star tracker optical references. The initial solution was to negotiate minor changes in the original LBS design to allow for the installation of a removable item of ground support equipment (GSE) that could be installed whenever measurements of the star tracker optical references were needed. However, this GSE could only be used to measure secondary optical reference cube faces not used by the star tracker vendor to obtain the relationship information and matrix transformations necessary to determine star tracker alignment. Unfortunately, due to unexpectedly large orthogonality errors between the measured secondary adjacent cube faces and the lack of cube calibration data, we required a method that could be used to measure the same reference cube faces as originally measured by the vendor. We describe an alternative technique to theodolite auto-collimation for measurement of an optical reference mirror pointing direction when normal incidence measurements are not possible. This technique was used to successfully align the GPM star trackers and has been used on a number of other NASA flight projects. We also discuss alignment theory as well as a GSFC-developed theodolite data analysis package used to analyze angular metrology data.

Hetherington, Samuel↗

Uncertainty in Soil Moisture Retrievals: an Ensemble Approach Using SMOS L-Band Microwave Data

The uncertainty of soil moisture (SM) retrievals from satellite brightness temperature (TB) observations depends primarily on the choice of radiative transfer model (RTM) parameters, prior SM information and TB inputs. This paper studies the sensitivity of several (quasi-)operational and experimental SM retrieval products from the Soil Moisture Ocean Salinity (SMOS) mission to these choices at 11 reference sites, located in 7 watersheds across the United States (US). Different literature-based RTM parameter sets cause large biases between retrievals. Whereas typical RTM parameter sets are calibrated for SM retrievals, it is shown that a parameter set carefully optimized for TB forward modeling can also be used for retrieving SM. It is also shown that the inclusion of dynamic prior SM estimates in a Bayesian retrieval scheme can strongly improve SM retrievals, regardless of the choice of RTM parameters, and that the use of multi-angular and multi-polarization TB does not necessarily lead to superior retrievals compared to retrievals based on TB data at a single incidence angle and polarization. The second part of this paper evaluates ensemble uncertainty metrics for SM retrievals obtained by propagating a wide range of RTM parameters through the RTM. As expected for bounded variables, the spread in the ensemble SM retrievals is smallest for wet and dry SM values and highest for intermediate SM values. After removal of the strong long-term mean bias associated with the RTM parameter values for individual ensemble members, the remaining anomaly ensemble SM spread of 0.037 cu m/cu m approximates the actual time series unbiased root-mean-square-difference of 0.042 cu m/cu m between ensemble mean retrievals and in situ reference data across the reference sites. However, the temporal variability in the anomaly ensemble spread reveals higher-order biases in the retrieval error, which should be accounted for when characterizing retrieval error.

Jan Quets↗

Some aversive characteristics of centrifugally generated gravity.

The effective weight of rats was manipulated by centrifugation. Two effective weight levels were obtained. In three escape avoidance conditions a lever press produced a change from a base level of 2.1 g to a response level of 1.1 g. In a punishment condition a response produced a change from a 1.1 g level to a 2.1 g level and in an extinction condition responses had no effect on the 2.1 g effective weight level present. All changes took 30 sec and were maintained for an additional 10 sec before a return to base level was initiated. When responses occurred closer together than the 40 sec, they delayed the return to base level by 40 sec. This 40 sec interval is referred to as response-contingent-time. The response rate and amount of response-contingent-time served as the data. The results confirmed previous data that centrifugation is aversive. The results are interpreted as indicating that the aversiveness is attributable to the increase in effective weight, and that rats can discriminate the different angular velocity-radius of rotation combinations used.

Altman, F.↗

The soft X-ray telescope for the SOLAR-A mission

The Soft X-ray Telescope (SXT) of the SOLAR-A mission is designed to produce X-ray movies of flares with excellent angular and time resolution as well as full-disk X-ray images for general studies. A selection of thin metal filters provide a measure of temperature discrimination and aid in obtaining the wide dynamic range required for solar observing. The co-aligned SXT aspect telescope will yield optical images for aspect reference, white-light flare and sunspot studies, and, possibly, helioseismology. This paper describes the capabilities and characteristics of the SXT for scientific observing.

Tsuneta, S.↗

Output Measurement Equations for Flexible Aircraft Flight Dynamics

A summary of output measurement equations for onboard sensors used in flight testing of flexible aircraft is presented. These equations include the effects of structural flexibility and are considerably more complex than the standard equations for rigid-body aircraft. The output equations discussed include accelerations from linear accelerometers, strains, angular rates, angular accelerations, Euler angles, true airspeed, and air flow angles. The output equations are derived in full form and then simplified in some cases. Linearized output equations, suitable for state-space or transfer function models, are also developed. Example flight test data from the X-56A subscale aeroelastic demonstrator is discussed, for reference.

Grauer, Jared A.↗

SU-E-T-391: Assessment and Elimination of the Angular Dependence of the Response of the NanoDot OSLD System in MV Beams

Purpose: Assess the angular dependence of the nanoDot OSLD system in MV X-ray beams at depths and mitigate this dependence for measurements in phantoms. Methods: Measurements for 6 MV photons at 3 cm and 10 cm depth and Monte Carlo simulations were performed. Two special holders were designed which allow a nanoDot dosimeter to be rotated around the center of its sensitive volume (5 mm diameter disk). The first holder positions the dosimeter disk perpendicular to the beam (en-face). It then rotates until the disk is parallel with the beam (edge on). This is referred to as Setup 1. The second holder positions the disk parallel to the beam (edge on) for all angles (Setup 2). Monte Carlo simulations using GEANT4 considered detector and housing in detail based on microCT data. Results: An average drop in response by 1.4±0.7% (measurement) and 2.1±0.3% (Monte Carlo) for the 90° orientation compared to 0° was found for Setup 1. Monte Carlo simulations also showed a strong dependence of the effect on the composition of the sensitive layer. Assuming 100% active material (Al??O??) results in a 7% drop in response for 90° compared to 0°. Assuming the layer to be completely water, results in a flat response (within simulation uncertainty of about 1%). For Setup 2, measurements and Monte Carlo simulations found the angular dependence of the dosimeter to be below 1% and within the measurement uncertainty. Conclusion: The nanoDot dosimeter system exhibits a small angular dependence off approximately 2%. Changing the orientation of the dosimeter so that a coplanar beam arrangement always hits the detector material edge on reduces the angular dependence to within the measurement uncertainty of about 1%. This makes the dosimeter more attractive for phantom based clinical measurements and audits with multiple coplanar beams. The Australian Clinical Dosimetry Service is a joint initiative between the Australian Department of Health and the Australian Radiation Protection and Nuclear Safety Agency.

07 ISOTOPE AND RADIATION SOURCES↗

Integrated fiber-mirror ion trap for strong ion-cavity coupling

We present and characterize fiber mirrors and a miniaturized ion-trap design developed to integrate a fiber-based Fabry-Perot cavity (FFPC) with a linear Paul trap for use in cavity-QED experiments with trapped ions. Our fiber-mirror fabrication process not only enables the construction of FFPCs with small mode volumes, but also allows us to minimize the influence of the dielectric fiber mirrors on the trapped-ion pseudopotential. We discuss the effect of clipping losses for long FFPCs and the effect of angular and lateral displacements on the coupling efficiencies between cavity and fiber. Optical profilometry allows us to determine the radii of curvature and ellipticities of the fiber mirrors. From finesse measurements, we infer a single-atom cooperativity of up to 12 for FFPCs longer than 200 μm in length; comparison to cavities constructed with reference substrate mirrors produced in the same coating run indicates that our FFPCs have similar scattering losses. We characterize the birefringence of our fiber mirrors, finding that careful fiber-mirror selection enables us to construct FFPCs with degenerate polarization modes. As FFPCs are novel devices, we describe procedures developed for handling, aligning, and cleaning them. We discuss experiments to anneal fiber mirrors and explore the influence of the atmosphere under which annealing occurs on coating losses, finding that annealing under vacuum increases the losses for our reference substrate mirrors. X-ray photoelectron spectroscopy measurements indicate that these losses may be attributable to oxygen depletion in the mirror coating. Special design considerations enable us to introduce a FFPC into a trapped ion setup. Our unique linear Paul trap design provides clearance for such a cavity and is miniaturized to shield trapped ions from the dielectric fiber mirrors. We numerically calculate the trap potential in the absence of fibers. In the experiment additional electrodes can be used to compensate distortions of the potential due to the fibers. Home-built fiber feedthroughs connect the FFPC to external optics, and an integrated nanopositioning system affords the possibility of retracting or realigning the cavity without breaking vacuum.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗