Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Advanced Detector Development”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Large Format Arrays for Far Infrared and Millimeter Astronomy

Some of the most compelling questions in modem astronomy are best addressed with submillimeter and millimeter observations. The question of the role of inflation in the early evolution of the universe is best addressed with large sensitive arrays of millimeter polarimeters. The study of the first generations of galaxies requires sensitive submillimeter imaging, which can help us to understand the history of energy release and nucleosynthesis in the universe. Our ability to address these questions is dramatically increasing, driven by dramatic steps in the sensitivity and size of available detector arrays. While the MIPS instrument on the SIRTF mission will revolutionize far infrared astronomy with its 1024 element array of photoconductors, thermal detectors remain the dominant technology for submillimeter and millimeter imaging and polarimetry. The last decade has seen the deployment of increasingly large arrays of bolometers, ranging from the 48 element arrays deployed on the KAO in the late 198Os, to the SHARC and SCUBA arrays in the 1990s. The past years have seen the deployment of a new generation of larger detector arrays in SHARC II (384 channels) and Bolocam (144 channels). These detectors are in operation and are beginning to make significant impacts on the field. Arrays of sensitive submillimeter bolometers on the SPIRE instrument on Herschel will allow the first large areas surveys of the sky, providing important insight into the evolution of galaxies. The next generation of detectors, led by SCUBA II, will increase the focal scale of these instruments by an order of magnitude. Two major missions are being planned by NASA for which further development of long wavelength detectors is essential, The SAFlR mission, a 10-m class telescope with large arrays of background limited detectors, will extend our reach into the epoch of initial galaxy formation. A major goal of modem cosmology is to test the inflationary paradigm in the early evolution of the universe. To this end, a mission is planned to detect the imprint of inflation on the CMB by precision measurement of its polarization. This work requires very large arrays of sensitive detectors which can provide unprecedented control of a wide range of systematic errors, given the small amplitude of the signal of interest. We will describe the current state of large format detector arrays, the performance requirements set by the new missions, and the different approaches being developed in the community to meet these requirements. We are confident that within a decade, these developments will lead to dramatic advances in our understanding of the evolution of the universe.

Moseley, Harvey↗

Ultra Low Power Imaging Systems Using CMOS Image Sensor Technology

The need for miniaturization in advanced science sensor systems has led to the development of a new image sensor technology, the active pixel image sensor (APS). The development of CMOS APS technology allows the integration of timing and control electronics, imaging detector arrays, signal chains and analog-to-digital conversion on a single integrated circuit. The impact on the imaging system is to reduce power by approximately 1000x over existing systems - from tens of watts to tens of milliwatts.

imaging↗

Characteristic Performance Evaluation of a new SAGe Well Detector for Small and Large Sample Geometries

Environmental scientific research requires a detector that has sensitivity low enough to reveal the presence of any contaminant in the sample at a reasonable counting time. Canberra developed the germanium detector geometry called Small Anode Germanium (SAGe) Well detector, which is now available commercially. The SAGe Well detector is a new type of low capacitance germanium well detector manufactured using small anode technology capable of advancing many environmental scientific research applications. The performance of this detector has been evaluated for a range of sample sizes and geometries counted inside the well, and on the end cap of the detector. The detector has energy resolution performance similar to semi-planar detectors, and offers significant improvement over the existing coaxial and Well detectors. Energy resolution performance of 750 eV Full Width at Half Maximum (FWHM) at 122 keV γ-ray energy and resolution of 2.0 - 2.3 keV FWHM at 1332 keV γ-ray energy are guaranteed for detector volumes up to 425 cm{sup 3}. The SAGe Well detector offers an optional 28 mm well diameter with the same energy resolution as the standard 16 mm well. Such outstanding resolution performance will benefit environmental applications in revealing the detailed radionuclide content of samples, particularly at low energy, and will enhance the detection sensitivity resulting in reduced counting time. The detector is compatible with electric coolers without any sacrifice in performance and supports the Canberra Mathematical efficiency calibration method (In situ Object Calibration Software or ISOCS, and Laboratory Source-less Calibration Software or LABSOCS). In addition, the SAGe Well detector supports true coincidence summing available in the ISOCS/LABSOCS framework. The improved resolution performance greatly enhances detection sensitivity of this new detector for a range of sample sizes and geometries counted inside the well. This results in lower minimum detectable concentrations compared to Traditional Well detectors. The SAGe Well detectors are compatible with Marinelli beakers and compete very well with semi-planar and coaxial detectors for large samples in many applications. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Magnon spectroscopy in the electron microscope

Abstract The miniaturization of transistors is approaching its limits owing to challenges in heat management and information transfer speed 1 . To overcome these obstacles, emerging technologies such as spintronics 2 are being developed, which make use of the electron’s spin as well as its charge. Local phenomena at interfaces or structural defects will greatly influence the efficiency of spin-based devices, making the ability to study spin-wave propagation at the nanoscale and atomic scale a key challenge 3,4 . The development of high-spatial-resolution tools to investigate spin waves, also called magnons, at relevant length scales is thus essential to understand how their properties are affected by local features. Here we detect bulk THz magnons at the nanoscale using scanning transmission electron microscopy (STEM). By using high-resolution electron energy-loss spectroscopy with hybrid-pixel electron detectors, we overcome the challenges posed by weak signals to map THz magnon excitations in a thin NiO nanocrystal. Advanced inelastic electron scattering simulations corroborate our findings. These results open new avenues for detecting magnons and exploring their dispersions and their modifications arising from nanoscale structural or chemical defects. This marks a milestone in magnonics and presents exciting opportunities for the development of spintronic devices.

Science & Technology - Other Topics↗

Crystal Growth and Detector Development for Underground Experiments

Cosmogenic production in germanium crystals grown on the surface can limit the sensitivity for the next generation deep underground experiments in searching for rare event physics beyond the Standard Model. One of the best solutions to eliminate unwanted cosmogenics is to produce the germanium crystals and detectors in an underground environment. The goal of this project is to create state-of-the-art detectors to advance neutrinoless double-beta decay and dark matter exploration research and technology while simultaneously paving the way for infrastructure to support an underground laboratory for zone refining, crystal growth, and detector fabrication at the Sanford Underground Research Facility. The greatest challenge in the growth of germanium crystals is a lack of precise control of individual crystal properties such as the impurity distribution, the dislocation density, and the crystalline structure. With knowledge gained from the pioneers in the field of crystal growth, the researchers have developed a novel technique to grow detector-grade crystals in South Dakota.

36 MATERIALS SCIENCE↗

The Chandra X-Ray Observatory Radiation Environmental Model Update

CRMFLX (Chandra Radiation Model of ion FLUX) is a radiation environment risk mitigation tool for use as a decision aid in planning the operation times for Chandra's Advanced CCD Imaging Spectrometer (ACIS) detector. The accurate prediction of the proton flux environment with energies of 100 - 200 keV is needed in order to protect the ACIS detector against proton degradation. Unfortunately, protons of this energy are abundant in the region of space where Chandra must operate. In addition, on-board particle detectors do not measure proton flux levels of the required energy range. CRMFLX is an engineering environment model developed to predict the proton flux in the solar wind, magnetosheath, and magnetosphere phenomenological regions of geospace. This paper describes the upgrades to the ion flux databases for the magnetosphere, magnetosheath, and solar wind regions. These data files were created by using Geotail and Polar spacecraft flux measurements only when the Advanced Composition Explorer (ACE) spacecraft's 0.14 MeV particle flux was below a threshold value. This new database allows for CRMFLX output to be correlated with both the geomagnetic activity level, as represented by the Kp index, as well as with solar proton events. Also, reported in this paper are results of analysis leading to a change in Chandra operations that successfully mitigates the false trigger rate for autonomous radiation events caused by relativistic electron flux contamination of proton channels.

Blackwell, William C.↗

The ladder and readout cables of intermediate silicon strip detector for sPHENIX

A new silicon-strip-type detector was developed for precise charged-particle tracking in the central rapidity region of heavy ion collisions. A new detector and collaboration at the Relativistic Heavy Ion Collider at Brookhaven National Laboratory is sPHENIX, which is a major upgrade of the PHENIX detector. The intermediate tracker (INTT) is part of the advanced tracking system of the sPHENIX detector complex together with a CMOS monolithic-active-pixel-sensor based silicon-pixel vertex detector, a time-projection chamber, and a micromegas-based detector. The INTT detector is barrel shaped and comprises 56 silicon ladders. Two different types of strip sensors of 78 micron pitch and 320 micron thick are mounted on each half of a silicon ladder. Each strip sensor is segmented into 8 × 2 and 5 × 2 blocks with lengths of 16 and 20 mm. Strips are read out with a silicon strip-readout (FPHX) chip. In order to transmit massive data from the FPHX to the down stream readout electronics card (ROC), a series of long and high speed readout cables were developed. This document focuses on the silicon ladder, the readout cables, and the ROC of the INTT. The radiation hardness is studied for some parts of the INTT devices in the last part of this document, since the INTT employed some materials from the technology frontier of the industry whose radiation hardness is not necessarily well known.

43 PARTICLE ACCELERATORS↗

Open Source Platform for Live Processing of High Data Rate Electron Microscopy (SBIR Phase I Award Topic 15, Subtopic B, Final Scientific / Technical Report)

4D scanning transmission electron microscopy (STEM) is experiencing a revolution both in terms of data size, and data veracity, as are many other areas of experimental data acquisition. This presents enormous opportunities to make new scientific discoveries, but is also hamstrung by aging software that is no longer fit for purpose. Experimental data acquisition platforms must make the same investments in software infrastructure that the simulation community made decades ago to take advantage of high-performance computing (HPC) if they hope to realize the full potential of the latest advances made in detector technology. This requires rethinking the design and deployment of hardware, moving away from small, fixed commodity computing capabilities with closed interfaces to open, modular, scalable systems designed for parallelism and throughput. The technical approach will leverage best-in-class open source technologies, and develop new approaches strategically to build an open source platform for experimental data acquisition targeting high data rate electron microscopy. The project will develop a software platform that uses the power and performance of modern HPC resources to ingest the large volume of data produced by electron microscopes using direct electron detectors. A set of configurable pipelines will be used to enable the processing to be tailored to the problem being investigated with builtin visualization of data at interactive rates. This project will leverage investments made by the DOE and other agencies to provide a powerful software platform for the experimental data community working with most powerful electron microscopes, such as 4D STEM detectors. It will create a platform that serves as a reference for the community. Permissive open source licensing will make the platform available to all, with a simple deployment strategy offering the ability to keep data close to where it is generated. This advanced software platform will require customization for each deployment, creating opportunities for software services that are typically offered to extend open source software platforms.

97 MATHEMATICS AND COMPUTING↗

WE-H-206-00: Advances in Preclinical Imaging

Lihong V. Wang: Photoacoustic tomography (PAT), combining non-ionizing optical and ultrasonic waves via the photoacoustic effect, provides in vivo multiscale functional, metabolic, and molecular imaging. Broad applications include imaging of the breast, brain, skin, esophagus, colon, vascular system, and lymphatic system in humans or animals. Light offers rich contrast but does not penetrate biological tissue in straight paths as x-rays do. Consequently, high-resolution pure optical imaging (e.g., confocal microscopy, two-photon microscopy, and optical coherence tomography) is limited to penetration within the optical diffusion limit (∼1 mm in the skin). Ultrasonic imaging, on the contrary, provides fine spatial resolution but suffers from both poor contrast in early-stage tumors and strong speckle artifacts. In PAT, pulsed laser light penetrates tissue and generates a small but rapid temperature rise, which induces emission of ultrasonic waves due to thermoelastic expansion. The ultrasonic waves, orders of magnitude less scattering than optical waves, are then detected to form high-resolution images of optical absorption at depths up to 7 cm, conquering the optical diffusion limit. PAT is the only modality capable of imaging across the length scales of organelles, cells, tissues, and organs (up to whole-body small animals) with consistent contrast. This rapidly growing technology promises to enable multiscale biological research and accelerate translation from microscopic laboratory discoveries to macroscopic clinical practice. PAT may also hold the key to label-free early detection of cancer by in vivo quantification of hypermetabolism, the quintessential hallmark of malignancy. Learning Objectives: To understand the contrast mechanism of PAT To understand the multiscale applications of PAT Benjamin M. W. Tsui: Multi-modality molecular imaging instrumentation and techniques have been major developments in small animal imaging that has contributed significantly to biomedical research during the past decade. The initial development was an extension of clinical PET/CT and SPECT/CT from human to small animals and combine the unique functional information obtained from PET and SPECT with anatomical information provided by the CT in registered multi-modality images. The requirements to image a mouse whose size is an order of magnitude smaller than that of a human have spurred advances in new radiation detector technologies, novel imaging system designs and special image reconstruction and processing techniques. Examples are new detector materials and designs with high intrinsic resolution, multi-pinhole (MPH) collimator design for much improved resolution and detection efficiency compared to the conventional collimator designs in SPECT, 3D high-resolution and artifact-free MPH and sparse-view image reconstruction techniques, and iterative image reconstruction methods with system response modeling for resolution recovery and image noise reduction for much improved image quality. The spatial resolution of PET and SPECT has improved from ∼6–12 mm to ∼1 mm a few years ago to sub-millimeter today. A recent commercial small animal SPECT system has achieved a resolution of ∼0.25 mm which surpasses that of a state-of-art PET system whose resolution is limited by the positron range. More recently, multimodality SA PET/MRI and SPECT/MRI systems have been developed in research laboratories. Also, multi-modality SA imaging systems that include other imaging modalities such as optical and ultrasound are being actively pursued. In this presentation, we will provide a review of the development, recent advances and future outlook of multi-modality molecular imaging of small animals. Learning Objectives: To learn about the two major multi-modality molecular imaging techniques of small animals. To learn about the spatial resolution achievable by the molecular imaging systems for small animal today. To learn about the new multi-modality imaging instrumentation and techniques that are being developed. Sang Hyun Cho; X-ray fluorescence (XRF) imaging, such as x-ray fluorescence computed tomography (XFCT), offers unique capabilities for accurate identification and quantification of metals within the imaging objects. As a result, it has emerged as a promising quantitative imaging modality in recent years, especially in conjunction with metal-based imaging probes. This talk will familiarize the audience with the basic principles of XRF/XFCT imaging. It will also cover the latest development of benchtop XFCT technology. Additionally, the use of metallic nanoparticles such as gold nanoparticles, in conjunction with benchtop XFCT, will be discussed within the context of preclinical multimodal multiplexed molecular imaging. Learning Objectives: To learn the basic principles of XRF/XFCT imaging To learn the latest advances in benchtop XFCT development for preclinical imaging Funding support received from NIH and DOD; Funding support received from GE Healthcare; Funding support received from Siemens AX; Patent royalties received from GE Healthcare; L. Wang, Funding Support: NIH; COI: Microphotoacoustics; S. Cho, Yes: ;NIH/NCI grant R01CA155446 DOD/PCRP grant W81XWH-12-1-0198.

60 APPLIED LIFE SCIENCES↗

WE-H-206-01: Photoacoustic Tomography: Multiscale Imaging From Organelles to Patients by Ultrasonically Beating the Optical Diffusion Limit

Lihong V. Wang: Photoacoustic tomography (PAT), combining non-ionizing optical and ultrasonic waves via the photoacoustic effect, provides in vivo multiscale functional, metabolic, and molecular imaging. Broad applications include imaging of the breast, brain, skin, esophagus, colon, vascular system, and lymphatic system in humans or animals. Light offers rich contrast but does not penetrate biological tissue in straight paths as x-rays do. Consequently, high-resolution pure optical imaging (e.g., confocal microscopy, two-photon microscopy, and optical coherence tomography) is limited to penetration within the optical diffusion limit (∼1 mm in the skin). Ultrasonic imaging, on the contrary, provides fine spatial resolution but suffers from both poor contrast in early-stage tumors and strong speckle artifacts. In PAT, pulsed laser light penetrates tissue and generates a small but rapid temperature rise, which induces emission of ultrasonic waves due to thermoelastic expansion. The ultrasonic waves, orders of magnitude less scattering than optical waves, are then detected to form high-resolution images of optical absorption at depths up to 7 cm, conquering the optical diffusion limit. PAT is the only modality capable of imaging across the length scales of organelles, cells, tissues, and organs (up to whole-body small animals) with consistent contrast. This rapidly growing technology promises to enable multiscale biological research and accelerate translation from microscopic laboratory discoveries to macroscopic clinical practice. PAT may also hold the key to label-free early detection of cancer by in vivo quantification of hypermetabolism, the quintessential hallmark of malignancy. Learning Objectives: To understand the contrast mechanism of PAT To understand the multiscale applications of PAT Benjamin M. W. Tsui: Multi-modality molecular imaging instrumentation and techniques have been major developments in small animal imaging that has contributed significantly to biomedical research during the past decade. The initial development was an extension of clinical PET/CT and SPECT/CT from human to small animals and combine the unique functional information obtained from PET and SPECT with anatomical information provided by the CT in registered multi-modality images. The requirements to image a mouse whose size is an order of magnitude smaller than that of a human have spurred advances in new radiation detector technologies, novel imaging system designs and special image reconstruction and processing techniques. Examples are new detector materials and designs with high intrinsic resolution, multi-pinhole (MPH) collimator design for much improved resolution and detection efficiency compared to the conventional collimator designs in SPECT, 3D high-resolution and artifact-free MPH and sparse-view image reconstruction techniques, and iterative image reconstruction methods with system response modeling for resolution recovery and image noise reduction for much improved image quality. The spatial resolution of PET and SPECT has improved from ∼6–12 mm to ∼1 mm a few years ago to sub-millimeter today. A recent commercial small animal SPECT system has achieved a resolution of ∼0.25 mm which surpasses that of a state-of-art PET system whose resolution is limited by the positron range. More recently, multimodality SA PET/MRI and SPECT/MRI systems have been developed in research laboratories. Also, multi-modality SA imaging systems that include other imaging modalities such as optical and ultrasound are being actively pursued. In this presentation, we will provide a review of the development, recent advances and future outlook of multi-modality molecular imaging of small animals. Learning Objectives: To learn about the two major multi-modality molecular imaging techniques of small animals. To learn about the spatial resolution achievable by the molecular imaging systems for small animal today. To learn about the new multi-modality imaging instrumentation and techniques that are being developed. Sang Hyun Cho; X-ray fluorescence (XRF) imaging, such as x-ray fluorescence computed tomography (XFCT), offers unique capabilities for accurate identification and quantification of metals within the imaging objects. As a result, it has emerged as a promising quantitative imaging modality in recent years, especially in conjunction with metal-based imaging probes. This talk will familiarize the audience with the basic principles of XRF/XFCT imaging. It will also cover the latest development of benchtop XFCT technology. Additionally, the use of metallic nanoparticles such as gold nanoparticles, in conjunction with benchtop XFCT, will be discussed within the context of preclinical multimodal multiplexed molecular imaging. Learning Objectives: To learn the basic principles of XRF/XFCT imaging To learn the latest advances in benchtop XFCT development for preclinical imaging Funding support received from NIH and DOD; Funding support received from GE Healthcare; Funding support received from Siemens AX; Patent royalties received from GE Healthcare; L. Wang, Funding Support: NIH; COI: Microphotoacoustics; S. Cho, Yes: ;NIH/NCI grant R01CA155446 DOD/PCRP grant W81XWH-12-1-0198.

60 APPLIED LIFE SCIENCES↗

WE-H-206-02: Recent Advances in Multi-Modality Molecular Imaging of Small Animals

Lihong V. Wang: Photoacoustic tomography (PAT), combining non-ionizing optical and ultrasonic waves via the photoacoustic effect, provides in vivo multiscale functional, metabolic, and molecular imaging. Broad applications include imaging of the breast, brain, skin, esophagus, colon, vascular system, and lymphatic system in humans or animals. Light offers rich contrast but does not penetrate biological tissue in straight paths as x-rays do. Consequently, high-resolution pure optical imaging (e.g., confocal microscopy, two-photon microscopy, and optical coherence tomography) is limited to penetration within the optical diffusion limit (∼1 mm in the skin). Ultrasonic imaging, on the contrary, provides fine spatial resolution but suffers from both poor contrast in early-stage tumors and strong speckle artifacts. In PAT, pulsed laser light penetrates tissue and generates a small but rapid temperature rise, which induces emission of ultrasonic waves due to thermoelastic expansion. The ultrasonic waves, orders of magnitude less scattering than optical waves, are then detected to form high-resolution images of optical absorption at depths up to 7 cm, conquering the optical diffusion limit. PAT is the only modality capable of imaging across the length scales of organelles, cells, tissues, and organs (up to whole-body small animals) with consistent contrast. This rapidly growing technology promises to enable multiscale biological research and accelerate translation from microscopic laboratory discoveries to macroscopic clinical practice. PAT may also hold the key to label-free early detection of cancer by in vivo quantification of hypermetabolism, the quintessential hallmark of malignancy. Learning Objectives: To understand the contrast mechanism of PAT To understand the multiscale applications of PAT Benjamin M. W. Tsui: Multi-modality molecular imaging instrumentation and techniques have been major developments in small animal imaging that has contributed significantly to biomedical research during the past decade. The initial development was an extension of clinical PET/CT and SPECT/CT from human to small animals and combine the unique functional information obtained from PET and SPECT with anatomical information provided by the CT in registered multi-modality images. The requirements to image a mouse whose size is an order of magnitude smaller than that of a human have spurred advances in new radiation detector technologies, novel imaging system designs and special image reconstruction and processing techniques. Examples are new detector materials and designs with high intrinsic resolution, multi-pinhole (MPH) collimator design for much improved resolution and detection efficiency compared to the conventional collimator designs in SPECT, 3D high-resolution and artifact-free MPH and sparse-view image reconstruction techniques, and iterative image reconstruction methods with system response modeling for resolution recovery and image noise reduction for much improved image quality. The spatial resolution of PET and SPECT has improved from ∼6–12 mm to ∼1 mm a few years ago to sub-millimeter today. A recent commercial small animal SPECT system has achieved a resolution of ∼0.25 mm which surpasses that of a state-of-art PET system whose resolution is limited by the positron range. More recently, multimodality SA PET/MRI and SPECT/MRI systems have been developed in research laboratories. Also, multi-modality SA imaging systems that include other imaging modalities such as optical and ultrasound are being actively pursued. In this presentation, we will provide a review of the development, recent advances and future outlook of multi-modality molecular imaging of small animals. Learning Objectives: To learn about the two major multi-modality molecular imaging techniques of small animals. To learn about the spatial resolution achievable by the molecular imaging systems for small animal today. To learn about the new multi-modality imaging instrumentation and techniques that are being developed. Sang Hyun Cho; X-ray fluorescence (XRF) imaging, such as x-ray fluorescence computed tomography (XFCT), offers unique capabilities for accurate identification and quantification of metals within the imaging objects. As a result, it has emerged as a promising quantitative imaging modality in recent years, especially in conjunction with metal-based imaging probes. This talk will familiarize the audience with the basic principles of XRF/XFCT imaging. It will also cover the latest development of benchtop XFCT technology. Additionally, the use of metallic nanoparticles such as gold nanoparticles, in conjunction with benchtop XFCT, will be discussed within the context of preclinical multimodal multiplexed molecular imaging. Learning Objectives: To learn the basic principles of XRF/XFCT imaging To learn the latest advances in benchtop XFCT development for preclinical imaging Funding support received from NIH and DOD; Funding support received from GE Healthcare; Funding support received from Siemens AX; Patent royalties received from GE Healthcare; L. Wang, Funding Support: NIH; COI: Microphotoacoustics; S. Cho, Yes: ;NIH/NCI grant R01CA155446 DOD/PCRP grant W81XWH-12-1-0198.

60 APPLIED LIFE SCIENCES↗

WE-H-206-03: Promises and Challenges of Benchtop X-Ray Fluorescence CT (XFCT) for Quantitative in Vivo Imaging

Lihong V. Wang: Photoacoustic tomography (PAT), combining non-ionizing optical and ultrasonic waves via the photoacoustic effect, provides in vivo multiscale functional, metabolic, and molecular imaging. Broad applications include imaging of the breast, brain, skin, esophagus, colon, vascular system, and lymphatic system in humans or animals. Light offers rich contrast but does not penetrate biological tissue in straight paths as x-rays do. Consequently, high-resolution pure optical imaging (e.g., confocal microscopy, two-photon microscopy, and optical coherence tomography) is limited to penetration within the optical diffusion limit (∼1 mm in the skin). Ultrasonic imaging, on the contrary, provides fine spatial resolution but suffers from both poor contrast in early-stage tumors and strong speckle artifacts. In PAT, pulsed laser light penetrates tissue and generates a small but rapid temperature rise, which induces emission of ultrasonic waves due to thermoelastic expansion. The ultrasonic waves, orders of magnitude less scattering than optical waves, are then detected to form high-resolution images of optical absorption at depths up to 7 cm, conquering the optical diffusion limit. PAT is the only modality capable of imaging across the length scales of organelles, cells, tissues, and organs (up to whole-body small animals) with consistent contrast. This rapidly growing technology promises to enable multiscale biological research and accelerate translation from microscopic laboratory discoveries to macroscopic clinical practice. PAT may also hold the key to label-free early detection of cancer by in vivo quantification of hypermetabolism, the quintessential hallmark of malignancy. Learning Objectives: To understand the contrast mechanism of PAT To understand the multiscale applications of PAT Benjamin M. W. Tsui: Multi-modality molecular imaging instrumentation and techniques have been major developments in small animal imaging that has contributed significantly to biomedical research during the past decade. The initial development was an extension of clinical PET/CT and SPECT/CT from human to small animals and combine the unique functional information obtained from PET and SPECT with anatomical information provided by the CT in registered multi-modality images. The requirements to image a mouse whose size is an order of magnitude smaller than that of a human have spurred advances in new radiation detector technologies, novel imaging system designs and special image reconstruction and processing techniques. Examples are new detector materials and designs with high intrinsic resolution, multi-pinhole (MPH) collimator design for much improved resolution and detection efficiency compared to the conventional collimator designs in SPECT, 3D high-resolution and artifact-free MPH and sparse-view image reconstruction techniques, and iterative image reconstruction methods with system response modeling for resolution recovery and image noise reduction for much improved image quality. The spatial resolution of PET and SPECT has improved from ∼6–12 mm to ∼1 mm a few years ago to sub-millimeter today. A recent commercial small animal SPECT system has achieved a resolution of ∼0.25 mm which surpasses that of a state-of-art PET system whose resolution is limited by the positron range. More recently, multimodality SA PET/MRI and SPECT/MRI systems have been developed in research laboratories. Also, multi-modality SA imaging systems that include other imaging modalities such as optical and ultrasound are being actively pursued. In this presentation, we will provide a review of the development, recent advances and future outlook of multi-modality molecular imaging of small animals. Learning Objectives: To learn about the two major multi-modality molecular imaging techniques of small animals. To learn about the spatial resolution achievable by the molecular imaging systems for small animal today. To learn about the new multi-modality imaging instrumentation and techniques that are being developed. Sang Hyun Cho; X-ray fluorescence (XRF) imaging, such as x-ray fluorescence computed tomography (XFCT), offers unique capabilities for accurate identification and quantification of metals within the imaging objects. As a result, it has emerged as a promising quantitative imaging modality in recent years, especially in conjunction with metal-based imaging probes. This talk will familiarize the audience with the basic principles of XRF/XFCT imaging. It will also cover the latest development of benchtop XFCT technology. Additionally, the use of metallic nanoparticles such as gold nanoparticles, in conjunction with benchtop XFCT, will be discussed within the context of preclinical multimodal multiplexed molecular imaging. Learning Objectives: To learn the basic principles of XRF/XFCT imaging To learn the latest advances in benchtop XFCT development for preclinical imaging Funding support received from NIH and DOD; Funding support received from GE Healthcare; Funding support received from Siemens AX; Patent royalties received from GE Healthcare; L. Wang, Funding Support: NIH; COI: Microphotoacoustics; S. Cho, Yes: ;NIH/NCI grant R01CA155446 DOD/PCRP grant W81XWH-12-1-0198.

60 APPLIED LIFE SCIENCES↗

Development of a Direct Neutral Density Diagnostic for Fusion Edge Plasmas

As magnetically confined plasmas progress towards ignition and long pulse experiments, measurement and control of the neutral density in the plasma edge has become a critical issue for stability, formation of transport barriers, and fueling. Recent experiments by our research group have demonstrated that is possible to use two-photon absorption laser induced fluorescence (TA-LIF) to directly measure the density of neutral hydrogen in helicon sources and in the HIT-SI3 spheromak. While those experiments validated key elements of a diagnostic system that would enable similar measurements in tokamak plasmas, they did not fully address the issue of performance optimization in the presence of intense background light at the fluorescence wavelength and they also identified a number of other issues that must be resolved before successful TALIF neutral density measurements in a tokamak are likely to be achieved. Additional specific concerns raised during design reviews with the leadership of the DIII-D tokamak facility included: the minimum detection threshold for this TALIF diagnostic (currently ~ 5 x 10 15 m -3 ) and the rate at which neutral density measurements could be obtained. Improving the system performance to reduce the minimum detection threshold and demonstrating a faster rate of density determination are required to advance this diagnostic to the level where it could be considered for implementation on a major tokamak facility in the USA. The key issues that will be addressed through additional technological development are: validation of a new, chromatic aberration-free, xenon calibration scheme; increasing the output power of the laser; and suppression of background emission at the fluorescence wavelength through optimization of the collection optics and gating of the photomultiplier detector with a goal of obtaining a minimum detection threshold of 5 x 10 14 m -3 . Another key technological development, so far only tested in helicon source experiments, is the validation of Doppler-free TALIF as a means of obtaining higher speed, calibrated, neutral density measurements in tokamak-like conditions at the full cadence of the pulsed TALIF laser. In this work, we propose to complete these technological advancements through installation and testing of our prototype TALIF system on the proto-MPEX experiment at Oak Ridge National Laboratory (ORNL). The proto-MPEX facility will provide plasma conditions similar to the edge plasma of a major tokamak experiment but with pulse lengths and pulse repetition rates ideally suited for extensive development of a TALIF neutral density diagnostic. Measurement of the absolute neutral density in the edge of a magnetically confined plasma is necessary for plasma density control; calculation of charge-exchange power losses; control of plasma-wall interactions; determination of the braking of plasma flow; determination of the fuel mixture in deuterium-tritium plasma; and understanding the dynamics of the divertor region in the plasma edge. In terms of potential impact on the worldwide fusion program, we note that in burning plasma experiments, such as ITER, a 100 mJ/pulse Doppler-free TALIF diagnostic should be capable of directly measuring the deuterium/tritium (D/T) isotope ratio in the outer 0.5 to 1.0 m of the plasma radius. The D/T ratio is a critically important parameter for the control and optimization of burning plasmas. Therefore, development of the diagnostic system proposed here is also relevant to long-term US participation in diagnostic development for large tokamaks.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Pathways to Improved Representation in Advanced NucleAr science (PIRANA)

This document presents the final technical report for Pathways to Improved Representation in Advanced NucleAr Science (PIRANA), supported by the U.S. Department of Energy Office of Science (Office of Nuclear Physics) under Award No. DE-SC0024677 through the Reaching a New Energy Sciences Workforce (RENEW) initiative. The project launched in Fall 2023 at Skyline College in San Bruno, California, a federally recognized Minority Serving Institution (MSI) and the only community college participating in the nEXO collaboration. Through this partnership, Skyline College established an accessible and rigorous research environment for its students. Over the course of the project, 10 student trainees made meaningful contributions to nEXO detector R&D and to activities aimed at expanding student engagement in advanced nuclear science. An additional 24 students completed the Summer Introduction to Research and Experimentation in Nuclear physics (SIREN), a three-week program developed from the training materials created for the nEXO trainees. All participating students engaged in opportunities to present their work locally and at national conferences, take part in public outreach, and contribute to a range of academic activities across campus. Collectively, these efforts extended the impact of the project throughout the wider Skyline College community.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

QPSK loop lock detection in the advanced receiver

The Advanced Receiver (ARX 2) currently being developed uses a Costas crossover loop to acquire and track the phase of an incoming quadrature phase-shift-keyed (QPSK) signal. The performance is described for the QPSK lock detector to be implemented, taking into account the phase jitter in the tracking loop. Simulations are used to verify the results of the analysis.

Mileant, A.↗

The Quickest, Lowest-cost Lunar Resource Assessment Program: Integrated High-tech Earth-based Astronomy

Science and technology applications for the Moon have not fully kept pace with technical advancements in sensor development and analytical information extraction capabilities. Appropriate unanswered questions for the Moon abound, but until recently there has been little motivation to link sophisticated technical capabilities with specific measurement and analysis projects. Over the last decade enormous technical progress has been made in the development of (1) CCD photometric array detectors; (2) visible to near-infrared imaging spectrometers; (3)infrared spectroscopy; (4) high-resolution dual-polarization radar imaging at 3.5, 12, and 70 cm; and equally important (5) data analysis and information extraction techniques using compact powerful computers. Parts of each of these have been tested separately, but there has been no programmatic effort to develop and optimize instruments to meet lunar science and resource assessment needs (e.g., specific wavelength range, resolution, etc.) nor to coordinate activities so that the symbiotic relation between different kinds of data can be fully realized. No single type of remotely acquired data completely characterizes the lunar environment, but there has been little opportunity for integration of diverse advanced sensor data for the Moon. Two examples of technology concepts for lunar measurements are given. Using VIS/near-IR spectroscopy, the mineral composition of surface material can be derived from visible and near-infrared radiation reflected from the surface. The surface and subsurface scattering properties of the Moon can be analyzed using radar backscattering imaging.

Pieters, Carle M.↗

Quantifying the uncertainty of synchrotron-based lattice strain measurements

Crystallographic lattice strains - measured using diffraction techniques - are the same magnitude as typical macroscopic elastic strains. From a research perspective, the main interest is in measuring changes in lattice strains induced during in-situ loading: either from one macroscopic stress level to another or from one cycle to the next. The hope is to link these measurements to deformation-induced changes in the internal structure of crystals, possibly related to inelastic deformation and damage. These measurements are relatively new - little experimental intuition exists and it is difficult to discern whether observed differences are due to actual micromechanical evolution or to random experimental fluctuations. If the measurements are linked to material evolution on the size scale of the individual crystal, they have the potential to change the ideas about grain scale deformation partitioning processes and can be used to validate crystal-based simulation frameworks. Therefore, understanding the uncertainty associated with the lattice strain experiments is a crucial step in their continued development. If the measured lattice strains are of the same order as the random fluctuations that are part of the measurement process, documenting the strains can create more confusion than understanding. Often lattice strain error is quoted as {+-}1 x 10{sup -4}. This simple value fails to account for the range of factors that contribute to the experimental uncertainty - which, if not properly accounted for, may lead to a false confidence in the measurements. The focus of this paper is the development of a lattice strain uncertainty expression that delineates the contributing factors into terms that vary independently: (i) the contribution from the instrument and (ii) the contribution from the material under investigation. These aspects of uncertainty are described, and it is then possible to employ a calibrant powder method (diffraction from an unstrained material with high-precision lattice constants) to quantify the instrument portion of the lattice strain uncertainty. In these experiments, the instrument contribution to the uncertainty has been found to be a function of the Bragg angle and the intensity of the diffracted peaks. To develop a model for the instrument portion of the lattice strain uncertainty two datasets obtained using a MAR345 online image plate at the Cornell High Energy Synchrotron Source and a GE 41RT amorphous silicon detector at the Advanced Photon Source have been examined.

43 PARTICLE ACCELERATORS↗

Experimental Validation of MCNP Models for PINS Shadow Shield Mockups

MCNP has been regarded as an indispensable tool in development of radiation detection systems, and it is cost effective, thanks to advances in computing power, to simulate various conceptual designs without even fabricating them. Development of various PINS systems have also benefited from MCNP modeling and simulation. MCNP models of PINS systems have been frequently used to understand detector responses and to fill the gap in experimental data. Recently, a backpack version PINS system was announced to be developed. When the neutron generator and the HPGe detector are built by external vendors, the shadow shield is the component to be designed to maximize the performance while meeting the sponsor’s requirements. In order to utilize MCNP modeling and simulation to find the best specification of the shadow shield, a campaign of PINS lab measurements with a few shadow shield mockups has been conducted to validate MCNP simulation results. This study is intended to validate MCNP simulations and models in preparation of another more extensive simulation study. Validation of neutron flux is also discussed later in this report even though neutron counts were not measured experimentally.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗