Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “AXIONS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

PASSAT: particle accelerator helioScopes for Slim Axion-like-particle deTection

We propose a novel method to search for axion-like particles (ALPs) at particle accelerator experiments. ALPs produced at the target via the Primakoff effect subsequently enter a region with a magnetic field, where they are converted to photons that are then detected. Dubbed Particle Accelerator helioScopes for Slim Axion-like-particle deTection (PASSAT), our proposal uses the principle of the axion helioscope but replaces ALPs produced in the Sun with those produced in a target material. Since we rely on ALP-photon conversions , our proposal probes light (slim) ALPs that are otherwise inaccessible to laboratory-based experiments which rely on ALP decay, and complements astrophysical probes that are more model-dependent. As a first application, we reinterpret existing data from the NOMAD experiment in light of PASSAT, and constrain the parameter space for ALPs lighter than $$\sim 100~\mathrm{eV}$$ ~ 100 eV and ALP-photon coupling larger than $$\sim 10^{-4}~\mathrm{GeV}^{-1}$$ ~ 10 - 4 GeV - 1 . As benchmarks of feasible low-cost experiments improving over the NOMAD limits, we study the possibility of re-using the magnets of the CAST and the proposed BabyIAXO experiments and placing them at the proposed BDF facility at CERN, together with some new detectors. We find that these realizations of PASSAT allow for a direct probe of the parameter space for ALPs lighter than $$\sim 100~\mathrm{eV}$$ ~ 100 eV and ALP-photon coupling larger than $$\sim 4\times 10^{-6}~\mathrm{GeV}^{-1}$$ ~ 4 × 10 - 6 GeV - 1 , which are regions that have not been probed yet by experiments with laboratory-produced ALPs. In contrast to other proposals aiming at detecting single or two-photon only events in hadronic beam dump environments, that rely heavily on Monte Carlo simulations, the background in our proposal can be directly measured in-situ , its suppression optimized, and the irreducible background statistically subtracted. Sensitivity evaluations with other beams will be the subject of a future paper. The measurements suggested in this paper represent an additional physics case for the BDF at CERN beyond those already proposed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

SMART U(1)$$_X$$: standard model with axion, right handed neutrinos, two Higgs doublets and U(1)$$_X$$ gauge symmetry

Abstract To address five fundamental shortcomings of the Standard Model (SM) of particle physics and cosmology, we propose a phenomenologically viable framework based on a $$U(1)_X \times U(1)_{PQ}$$ U ( 1 ) X × U ( 1 ) PQ extension of the SM, that we call “SMART U(1) $$_X$$ X ”. The $$U(1)_X$$ U ( 1 ) X gauge symmetry is a well-known generalization of the $$U(1)_{B-L}$$ U ( 1 ) B - L symmetry and $$U(1)_{PQ}$$ U ( 1 ) PQ is the global Peccei–Quinn (PQ) symmetry. Three right handed neutrinos are added to cancel $$U(1)_X$$ U ( 1 ) X related anomalies, and they play a crucial role in understanding the observed neutrino oscillations and explaining the observed baryon asymmetry in the universe via leptogenesis. Implementation of PQ symmetry helps resolve the strong CP problem and also provides axion as a compelling dark matter (DM) candidate. The $$U(1)_X$$ U ( 1 ) X gauge symmetry enables us to implement the inflection-point inflation scenario with $$H_{inf} \lesssim 2 \times 10^{7}$$ H inf ≲ 2 × 10 7 GeV, where $$H_{inf}$$ H inf is the value of Hubble parameter during inflation. This is crucial to overcome a potential axion domain wall problem as well as the axion isocurvature problem. The SMART U(1) $$_X$$ X framework can be successfully implemented in the presence of SU (5) grand unification, as we briefly show.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Development of New Directions in Axion Dark Matter Searches

The bright objects we observe in the night sky make up less than 20% of the matter in the Universe. More than 80% of matter is invisible dark matter [1], which was postulated because the amount of visible matter in galaxy clusters could not account for the galaxies’ velocities [2]. Observations from cosmology and astrophysics that converge on the existence of dark matter include the cosmic microwave background power spectrum [3], cluster and galactic rotation curves [2], gravitational lensing [4,5] and large-scale structure formation [6]. The existence of dark matter is one of the biggest unsolved mysteries in physics, providing concrete evident for physics beyond the Standard Model (SM) of particle physics. Many particle candidates have been introduced, including weakly interacting massive particles (WIMPs) and ultralight bosons, such as the axion [7]. No candidates have been discovered, despite many searches, and the nature of dark matter is still unknown. The axion is a new fundamental spin-0 particle, which was originally motivated by explaining the strong charge-parity ( CP ) problem of quantum chromodynamics (QCD) [7], the theory of the strong nuclear force within nucleons. The CP -violating term in QCD within the SM is expected to generate a sizable neutron electric dipole moment (EDM), while the experimental upper bound is roughly one trillionth that size [8]. The strong CP problem is the non-observation of this neutron EDM. Discovery of axions would aid in understanding both the cosmological dark matter problem and the strong CP problem.

79 ASTRONOMY AND ASTROPHYSICS↗

Quantum system engineering for a next-generation search for axion dark matter. Final report

This project pursued two major experimental goals related to the quantum engineering of the ensemble of nuclear spin qubits, as a potential sensing platform for axion-like dark matter: (1) control the fidelity of spin ensemble state preparation, (2) characterize the coherence time of the spin ensemble under different drive conditions. We have successfully achieved these goals. We have experimentally demonstrated control over the polarization of the 207 Pb nuclear spin ensemble, using light-induced transient paramagnetic centers. We have also performed NMR measurements on the 207 Pb spin ensemble in solid ferroelectric PMN-PT, demonstrating the T 2 coherence time of 16.7 ms. We have used this approach to set new experimental limits on the EDM and the gradient interactions of axion-like dark matter in the mass range 162 neV to 166 neV. In addition, having characterized the magnetic resonance properties of the 207 Pb spin ensemble in solid ferroelectric PMN-PT, we have formulated the technical requirements needed to reach the quantum sensitivity limits in a magnetic resonance-based search for axion-like dark matter.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Calculations for cosmic axion detection

Calculations are presented, using properly nomalized couplings and masses for Dine-Fischler-Srednicki axions, of power rates and signal temperatures for axion-photon conversion in microwave cavities. The importance of the galactic-halo axion line shape is emphasized. Spin-coupled detection as an alternative to magnetic-field-coupled detection is mentioned.

Krauss, L.↗

Laser-induced axion photoproduction

Axion photoproduction is suggested as a systematic technique for investigating the coupling of new elementary pseudoscalar or scalar particles in the megaelectronvolt mass range to leptons, photons, and hadronic matter. The experiments involve a configuration where a low-energy photon collides with a relativistic electron beam. Threshold production energies of 300 GeV can be accomplished with an optical laser, and those of 14.5-50 GeV can be achieved with wigglers directed onto an electron beam. With this scheme, at least 10 to the -7th of the electrons can be converted to axions, providing a 1-100 thousand/s relativistic beam of axions.

Brodsky, S. J.↗

Simulation of Axion-like Particles at DarkQuest

DarkQuest is a collaboration at Fermilab searching for beyond the StandardModel (SM) physics using a xed target beam dump experiment. This experiment featuresa proton beam colliding with a target and creating particles, possibly theoretical ones,from the interactions that occur. A popular theoretical particle is the axion, an elementaryparticle that explains the breakage of symmetry that occurs in our current model of physics,called the strong CP problem. An axion-like particle (ALP) is similar to an axion in itsresolution of the strong CP problem, but has mass, and so is detectable by experimentation.By simulating the production and decay of an ALP, we can estimate the region of parameterspace of ALP mass and SM coupling that DarkQuest could make a discovery.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

THERMAL/STRUCTURAL ANALYSIS OF THE AXION QUANTUM METROLOGY CAVITY AND ITS COMPONENTS

This research was centered around maximizing the capability to cool dielectric material within a containment unit, or Photonic Band Gap (PBG) cavity, designed for detecting axion dark matter and identifying the unit’s thermal properties. There are multiple types of PBG cavities, but the latest version that axion researchers wish to use has been theorized to contain possible issues related to its thermal properties. Thermal conductivity is an issue with the dielectric material because it is made from alumina which is highly insulative. This is important since the research is being done in a cryogenic environment and the thermal noise affects the quantum bit used for detecting the axion to photon conversion process. Therefore, any improvements to this unit should be justified and implemented but are not entirely limited to thermal contact related aspects of PBG cavities. A prospect of using sapphire in place of alumina also exists, but this is a more expensive, less tested, and more elusive material to justify the creation of a full dielectric structure out of sapphire. Thermal aspects of the cavity were analyzed using finite element method (FEM) and an experiment designed to test different thermal joint materials. FEM was used to check the contraction of the cavity during cooling, the contact quality between the dielectric material and cavity wall, theheat flow rate through the assembly, and helps visualize the cavity’s reaction to different design changes. A simple comparison between thermal conductivity curves justified the usage of sapphire over alumina from a thermal property point of view. Thus, the method of experimentation had an additional dielectric material, sapphire, to test with and compare to alumina. The thermal test identified which material is best to use for a thermal joint but also simultaneously found the conductance of the joint and dielectric material as well as an estimate for what the temperature is inside the larger scale cavity since a thermometer cannot be placed inside the PBG when it cools. Initially, the cavity simulation was tested for structural deformation properties and stress distribution since it is made of copper which contracts heavily in comparison to most other materials. The reduction in volume of the cavity was less than anticipated which gave more room for a possible usage of a modified thermal joint for additional contact area and higher conductivity.

43 PARTICLE ACCELERATORS↗

Maximizing quantum enhancement in axion dark matter experiments

We provide a comprehensive comparison of linear amplifiers and microwave photon counters in axion dark matter experiments. The study is done assuming a range of realistic operating conditions and detector parameters, over the frequency range between 1 and 30 GHz. As expected, photon counters are found to be advantageous under low background, at high frequencies (𝜈 >5 GHz), if they can be implemented with robust wide-frequency tuning or a very low dark count rate. Additional noteworthy observations emerging from this study include: (1) an expanded applicability of off-resonance photon background reduction, including the single-quadrature state squeezing, for scan rate enhancements; (2) a much broader appeal for operating the haloscope resonators in the overcoupling regime, up to 𝛽 ∼10; (3) the need for a detailed investigation into the cryogenic and electromagnetic conditions inside haloscope cavities to lower the photon temperature for future experiments; (4) the necessity to develop a distributed network of coupling ports in high-volume axion haloscopes to utilize these potential gains in the scan rate.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Beehive haloscope for high-mass axion dark matter

We propose a new haloscope geometry that can arbitrarily increase the resonator volume for a given target axion mass. This geometry consists of closely packed, overlapping coaxial cavities operating as a single resonator. While the resonant frequency is still determined by the dimensions of the individual “cells,” the strong interactions between the cells encourage the entire “beehive” to oscillate in phase, a phenomenon expected of tightly coupled harmonic oscillators. This synchronization behavior allows the construction of a singly connected large volume resonator at high frequency by simply increasing the number of the cells. Using direct numerical simulations, we verify the existence of a global eigenmode that has a high (40%) form factor in a 169-element beehive resonator. The resonant frequency of the eigenmode is tunable by moving the center rods laterally in unison. The form factor is very tolerant to dimensional deviations and misalignment as a result of mode hybridization due to strong coupling. The beehive haloscope inherits many appealing properties from the conventional coaxial cavity: a high quality factor, compatibility with a solenoid magnet, and ease of fabrication, tuning, and coupling. We argue that this geometry is an excellent candidate for high-mass axion searches covering the post-inflationary parameter space (>5 GHz).

47 OTHER INSTRUMENTATION↗

Exploration of Wire Array Metamaterials for the Plasma Axion Haloscope

A plasma haloscope has recently been proposed as a feasible approach to extend the search for dark matter axions above 10 GHz (≈40 μeV), whereby the microwave cavity in a conventional axion haloscope is supplanted by a wire array metamaterial. Since the plasma frequency of a metamaterial is determined by its unit cell, and is thus a bulk property, a metamaterial resonator of any frequency can be made arbitrarily large, in contrast to a microwave cavity which incurs a steep penalty in volume with increasing frequency. To assess the actual potential of this concept as a practical dark matter haloscope, the basic properties of wire array metamaterials have been investigated through an extensive series of S 21 measurements in the 10 GHz range. This report presents some new systematics of wire array metamaterials themselves including the approach to full plasmonic behavior, the applicability of the semianalytic theory of Belov, and estimates of the loss term which bode favorably for the plasmonic haloscope application. This present work constitutes the first precision test of the semianalytic theory of Belov et al., for which the predicted plasma frequency agrees with the experimental value at the 0.1% level.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Energy conservation and axion back-reaction in a magnetic field

Axion clumps in an external magnetic field can emit electromagnetic radiation which causes them to decay. In the presence of a plasma, such radiation can become resonant if the clump frequency matches the plasma frequency. Typically, the decay or back-reaction of the clump is ignored in the literature when analyzing such radiation. In this paper we present a self consistent, semi-analytic approach which captures axion backreaction using energy conservation. We find that inclusion of back-reaction changes the clump frequency over time enabling clumps with a range of different initial frequencies to become resonant at some point in their time evolution.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Zero modes of massive fermions delocalize from axion strings

Massless chiral excitations can arise from the interactions between a fermion and an axion string, propagating along the string and allowing it to superconduct. The properties of these excitations, or zero modes, dictate how the string interacts with light and can thus have important phenomenological consequences. In this paper, we add a nowhere-vanishing Dirac mass for the fermion in the usual model of axion electrodynamics. We find that the zero modes exhibit an interesting phase structure in which they delocalize from the string’s core as the mass increases, up until a critical value past which they disappear. We study this structure from an analytic perspective, with explicit numerical solutions, and via anomaly inflow arguments. Finally, we derive the two-dimensional effective theory of the zero mode and its interactions with the four-dimensional gauge field and show how this effective theory breaks down as the zero modes delocalize.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Transient phenomena in the axion assisted Schwinger effect

Particle production induced by a time-dependent background is well understood as the projection of the time-evolved initial state onto a set of final states. While the asymptotic initial and final states are well defined in the usual way, the definition of particles and antiparticles at intermediate times in the presence of external fields is ambiguous. These external fields moreover induce divergences which require regularization. In this paper we clarify some subtleties in the computation of transient effects in physical quantities for fermions in a homogeneous axion background, including Schwinger production in background electromagnetic fields. The presence of the axion requires particular care as well as knowledge of the UV theory when regulating the theory and computing the vacuum contribution to the fermion energy.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Design and operational experience of a microwave cavity axion detector for the 20 – 100 μ eV range

We describe a dark matter axion detector designed, constructed, and operated both as an innovation platform for new cavity and amplifier technologies and as a data pathfinder in the 5-25 GHz range (~20-100 eV). The platform is small but flexible to facilitate the development of new microwave cavity and amplifier concepts in an operational environment. The experiment has recently completed its first data production; it is the first microwave cavity axion search to deploy a Josephson parametric amplifier and a dilution refrigerator to achieve near-quantum limited performance.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Supersymmetry and dark matter post LHC8: Why we may expect both axion and WIMP detection

In the post-LHC8 era, it is perceived that what is left of SUSY model parameter space is highly finetuned in the EW sector (EWFT). We discuss how conventional measures overestimate EWFT in SUSY theory. Radiatively-driven natural SUSY (RNS) models maintain the SUSY GUT paradigm with low EWFT at 10% level, but are characterized by light higgsinos ~100–300 GeV and a thermal underabundance of WIMP dark matter. Implementing the SUSY DFSZ solution to the strong CP problem explains the small μ parameter but indicates dark matter should be comprised mainly of axions with a small admixture of higgsino-like WIMPs. While RNS might escape LHC14 searches, we would expect ultimately direct detection of both WIMPs and axions. An e⁺e⁻ collider with √(s)~500–600 GeV should provide a thorough search for the predicted light higgsinos.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Cavity design for high-frequency axion dark matter detectors

In this paper, in an effort to extend the usefulness of microwave cavity detectors to higher axion masses, above ~8 μeV (~2 GHz), a numerical trade study of cavities was conducted to investigate the merit of using variable periodic post arrays and regulating vane designs for higher-frequency searches. The results show that both designs could be used to develop resonant cavities for high-mass axion searches. Finally, multiple configurations of both methods obtained the scanning sensitivity equivalent to approximately 4 coherently coupled cavities with a single tuning rod.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Search for 14.4 keV solar axions from M1 transition of {sup 57}Fe with CUORE crystals

We report the results of a search for axions from the 14.4 keV M1 transition from {sup 57}Fe in the core of the sun using the axio-electric effect in TeO{sub 2} bolometers. The detectors are 5 × 5 × 5 cm{sup 3} crystals operated at about 10 mK in a facility used to test bolometers for the CUORE experiment at the Laboratori Nazionali del Gran Sasso in Italy. An analysis of 43.65 kg⋅d of data was made using a newly developed low energy trigger which was optimized to reduce the energy threshold of the detector. An upper limit of 0.58 c⋅kg{sup −1}⋅d{sup −1} is established at 95% C.L., which translates into lower bounds f{sub A} ≥ 3.12 × 10{sup 5} GeV 95% C.L. (DFSZ model) and f{sub A} ≥ 2.41 × 10{sup 4} GeV 95% C.L. (KSVZ model) on the Peccei-Quinn symmetry-breaking scale, for a value of S = 0.5 of the flavor-singlet axial vector matrix element. These bounds can be expressed in terms of axion masses as m{sub A} ≤ 19.2 eV and m{sub A} ≤ 250 eV at 95% C.L. in the DFSZ and KSVZ models respectively. Bounds are given also for the interval 0.35 ≤ S ≤ 0.55.

79 ASTRONOMY AND ASTROPHYSICS↗