Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “APERTURE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

The Simons Observatory: Cryogenic half wave plate rotation mechanism for the small aperture telescopes

We present the requirements, design, and evaluation of the cryogenic continuously rotating half-wave plate (CHWP) for the Simons Observatory (SO). SO is a cosmic microwave background polarization experiment at Parque Astronómico de Atacama in northern Chile that covers a wide range of angular scales using both small (Ø0.42 m) and large (Ø6 m) aperture telescopes. In particular, the small aperture telescopes (SATs) focus on large angular scales for primordial B-mode polarization. To this end, the SATs employ a CHWP to modulate the polarization of the incident light at 8 Hz, suppressing atmospheric 1/f noise and mitigating systematic uncertainties that would otherwise arise due to the differential response of detectors sensitive to orthogonal polarizations. The CHWP consists of a 505 mm diameter achromatic sapphire HWP and a cryogenic rotation mechanism, both of which are cooled down to ~50 K to reduce detector thermal loading. Under normal operation, the HWP is suspended by a superconducting magnetic bearing and rotates with a constant 2 Hz frequency, controlled by an electromagnetic synchronous motor. We find that the number of superconductors and the number of magnets that make up the superconducting magnetic bearing are important design parameters, especially for the rotation mechanism’s vibration performance. The rotation angle is detected through an angular encoder with a noise level of 0.07 μrad √ $\overline{s}$. During a cooldown process, the rotor is held in place by a grip-and-release mechanism that serves as both an alignment device and a thermal path. In this paper, we provide an overview of the SO SAT CHWP: its requirements, hardware design, and laboratory performance.

47 OTHER INSTRUMENTATION↗

The Simons Observatory: forecasted constraints on primordial gravitational waves with the expanded array of Small Aperture Telescopes

We present updated forecasts for the scientific performance of the degree-scale (0.5 deg FWHM at 93 GHz), deep-field survey to be conducted by the Simons Observatory (SO). By 2027, the SO Small Aperture Telescope (SAT) complement will be doubled from three to six telescopes, including a doubling of the detector count in the 93 GHz and 145 GHz channels to 48,160 detectors. Combined with a planned extension of the survey duration to 2035, this expansion will significantly enhance SO's search for a B-mode signal in the polarisation of the cosmic microwave background, a potential signature of gravitational waves produced in the very early Universe. Assuming a 1/f noise model with knee multipole ℓ knee = 50 and a moderately complex model for Galactic foregrounds, we forecast a 1σ (or 68% confidence level) constraint on the tensor-to-scalar ratio r of σ r = 1.2 × 10 -3 , assuming no primordial B-modes are present. This forecast assumes that 70% of the B-mode lensing signal can ultimately be removed using high resolution observations from the SO Large Aperture Telescope (LAT) and overlapping large-scale structure surveys. For more optimistic assumptions regarding foregrounds and noise, and assuming the same level of delensing, this forecast constraint improves to σ r = 7 × 10 -4 . These forecasts represent a major improvement in SO's constraining power, being a factor of around 2.5 times better than what could be achieved with the originally planned campaign, which assumed the existing three SATs would conduct a five-year survey.

CMBR experiments↗

Greater aperture counteracts effects of reduced stomatal density on WUE: a case study on sugarcane and meta-analysis

Stomata regulate CO 2 and water vapor exchange between leaves and the atmosphere. Stomata are a target for engineering to improve crop intrinsic water use efficiency (iWUE). One example is by expressing genes that lower stomatal density (SD) and reduce stomatal conductance (g sw ). However, the quantitative relationship between reduced SD, g sw , and the mechanisms underlying it is poorly understood. We addressed this knowledge gap using low-SD sugarcane (Saccharum spp. hybrid) as a case study alongside a meta-analysis of data from 10 species. Transgenic expression of EPIDERMAL PATTERNING FACTOR 2 from Sorghum bicolor (SbEFP2) in sugarcane reduced SD by 26-38% but did not affect gsw compared to wildtype. Further, no changes occurred in stomatal complex size or proxies for photosynthetic capacity. Measurements of gas exchange at low CO 2 concentrations that promote complete stomatal opening to normalize aperture size between genotypes were combined with modeling of maximum gsw from anatomical data. These data suggest that increased stomatal aperture is the only possible explanation for maintaining gsw when SD is reduced. Meta-analysis across C 3 dicots, C 3 monocots, and C 4 monocots revealed engineered reductions in SD are strongly correlated with lower gsw (r 2 =0.60-0.98), but this response is damped relative to the change in anatomy.

59 BASIC BIOLOGICAL SCIENCES↗

Stable Photoemission from the Wehnelt Aperture Surface in 4D Ultrafast Electron Microscopy

Here we show that photoemission with high long-term stability that is immediate and robust can be generated from the surface of the Wehnelt aperture in a TEG-based UEM. Further, we show that the resulting photobeam quality can be at least as good as that from LaB 6 , whether under photo or thermionic operation. We hypothesize that the energy distribution and the temporal properties of the beam are improved relative to LaB 6 owing to the closer match of photon energy to aperture work function.

36 MATERIALS SCIENCE↗

Polarization-dependent atomic dipole traps behind a circular aperture for neutral-atom quantum computing

The neutral-atom quantum computing community has successfully implemented almost all necessary steps for constructing a neutral-atom quantum computer. We present computational results of a study aimed at solving the remaining problem of creating a quantum memory with individually addressable sites for quantum computing. The basis of this quantum memory is the diffraction pattern formed by laser light incident on a circular aperture. Very close to the aperture, the diffraction pattern has localized bright and dark spots that can serve as red-detuned or blue-detuned atomic dipole traps. These traps are suitable for quantum computing even for moderate laser powers. In particular, for moderate laser intensities ({approx}100 W/cm{sup 2}) and comparatively small detunings ({approx}1000-10 000 linewidths), trap depths of {approx}1 mK and trap frequencies of several to tens of kilohertz are achieved. Our results indicate that these dipole traps can be moved by tilting the incident laser beams without significantly changing the trap properties. We also explored the polarization dependence of these dipole traps. We developed a code that calculates the trapping potential energy for any magnetic substate of any hyperfine ground state of any alkali-metal atom for any laser detuning much smaller than the fine-structure splitting for any given electric field distribution. We describe details of our calculations and include a summary of different notations and conventions for the reduced matrix element and how to convert it to SI units. We applied this code to these traps and found a method for bringing two traps together and apart controllably without expelling the atoms from the trap and without significant tunneling probability between the traps. This approach can be scaled up to a two-dimensional array of many pinholes, forming a quantum memory with single-site addressability, in which pairs of atoms can be brought together and apart for two-qubit gates for quantum computing.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Transmission of Megawatt Relativistic Electron Beams through Millimeter Apertures

High power, relativistic electron beams from energy recovery linacs have great potential to realize new experimental paradigms for pioneering research in fundamental and applied research. A major design consideration for these new generation of experimental capabilities is the understanding of the halo associated with these bright, intense beams. In this Letter, we report on measurements performed using the 100 MeV, 430 kWatt CW electron beam from the energy recovery linac at the Jeff erson Laboratory's Free Electron Laser facility as it traversed a set of small apertures in a 127 mm long aluminum block. Thermal measurements of the block together with neutron measurements near the beam-target interaction point yielded a consistent understanding of the beam losses. These were determined to be 3 ppm through a 2 mm diameter aperture and were maintained during a 7 hour continuous run.

43 PARTICLE ACCELERATORS↗

Large aperture vibrating wire monitor with two mechanically coupled wires for beam halo measurements

Development of a new type of vibrating wire monitor (VWM), which has two mechanically coupled wires (vibrating and target), is presented. The new monitor has a much larger aperture size than the previous model of the VWM, and thus allows us to measure transverse beam halos more effectively. A prototype of such a large aperture VWM with a target wire length of 60 mm was designed, manufactured, and bench-tested. Initial beam measurements have been performed at the Fermilab High Intensity Neutrino Source facility, and key results are presented.

43 PARTICLE ACCELERATORS↗

Magnetic and Mechanical Design of a 15-T Large Aperture Dipole Magnet for Cable Testing

© 2019 IEEE. A large aperture Nb 3 Sn dipole is proposed to replace the magnet assembly of EDIPO, which was irreversibly damaged in 2016. The goal is to generate a background field of 15 T at 4.2 K in a clear aperture of approximately 100×150 mm 2 and over a uniform length of 1000 mm in order to test superconducting cables for both fusion and high-energy physics applications. The magnet features a block-type coil design wound with wide Rutherford cable (two alternative coil cross sections are considered) and supported by a mechanical structure based on keys-and-bladders technology. In the end regions, the coils tilt up (flare) through a hard-way bend of the cables to provide room for the test well, following a layout already adopted in the LBNL HD2 and CERN-CEA FRESCA2 magnets. The two considered coil design alternatives aim at minimizing the mechanical stress in the coil windings. One coil pack design makes the use of two double pancake coils per pole, whereas the other alternative features three double pancakes per pole. Both design options are presented focusing on the results of numerical computations carried out with finite-element models to investigate peak stresses in the coils during room-temperature pre-loading, cool down, and powering.

Sarasola, Xabier (ORCID:0000000324306939)↗

Development and Test of a Large-aperture Nb3Sn Cos-theta Dipole Coil with Stress Management

The design concept of the Electron Ion Collider (EIC), which is under construction at BNL, considers adding a 2nd Interaction Region (IR) and detector to the machine after completion of the present EIC project. Recent progress with development and fabrication of large-aperture high-field magnets based on the Nb3Sn technology for the HL-LHC makes this technology interesting for the 2nd EIC IR. This paper summarizes the results of feasibility studies of large-aperture high-field Nb3Sn dipoles and quadrupoles for the 2nd EIC IR.

43 PARTICLE ACCELERATORS↗

Quench Performance of a Large-Aperture Nb 3 Sn Cos-Theta Coil With Stress Management in Dipole Mirror Configurations

A 123-mm-aperture Nb 3 Sn cos-theta (CT) dipole coil with stress management (SM) has been developed at Fermilab to demonstrate and test the SM concept, including coil design, fabrication technology, and performance. The first SMCT1 coil has been fabricated and assembled together with a 60-mm-aperture Nb 3 Sn coil inside a dipole mirror structure and tested separately and in series with the inner coil. This article summarizes the design, parameters, and quench performance of the SMCT1 coil in a dipole mirror configuration.

43 PARTICLE ACCELERATORS↗

Design of B2PF: A Large Aperture Nb-Ti Dipole Magnet for the Electron-Ion Collider

Here, we present the initial design of the matching dipole B2PF, a large aperture cosine-theta magnet for the Electron-Ion Collider (EIC). First we share an optimized 2D magnet cross-section based on a double-layer design with Nb-Ti Rutherford cable. This cross-section is optimized to meet the required field quality in the 120 mm coil aperture both at the nominal operating current and considering iron saturation effects during the ramp. Next, we share a first design of the 3D coil ends optimized for windability, field quality, and minimizing the conductor peak field. Based on the resulting peak field, we evaluate the short-sample margin of the design for an operating target of 6.3 T dipole field at 1.9 K. Finally, we share an initial mechanical design study which utilizes a key-and-bladder support structure capable of adjusting magnet preload.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Design and Construction of a Prototype B1pF Large Aperture Rutherford Cable Superconducting Magnet for the EIC Interaction Region

Brookhaven National Laboratory (BNL) was chosen to host the international Electron-Ion Collider (EIC), which will collide high energy and highly polarized hadron and electron beams with a center of mass energy up to 140 GeV. The Interaction Region (IR) requires several large aperture, relatively high field superconducting dipole and quadrupole magnets, some of which are very closely spaced. B1pF is a large aperture (300 mm coil ID), medium field (4.2 T), 3 meter long superconducting dipole magnet. Its size is larger than the largest superconducting magnet in the RHIC accelerator (180 mm DX dipole, 4.2 T, 3.7 m long). As such, B1pF was chosen as the representative magnet to be prototyped to demonstrate the technological choice, design and construction details. Here, this paper describes the analyses and considerations which informed both the magnet and magnet tooling designs. This paper will summarize the construction results so far, in particular the plan for novel coil winding tooling and the test coil winding & curing program that was carried out prior to coil and magnet construction.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Double Aperture HTS Dipole Magnet Model for the Persistent Current Operation

Particle accelerators use many different types of magnets. There is an interest in replacing rather low-field conventional resistive magnets with high-temperature superconducting (HTS) magnets. The main goal is to reduce operational expenses, which is critical during the continuously increasing cost of electricity. At Fermilab, several HTS accelerator magnets were built and successfully tested. The paper described a variant of the double-aperture dipole magnet that could be suitable for future Lepton Colliders. A single short-circuited HTS coil of 3.8 kA generates a homogeneous magnetic field of 57 mT in both magnet gaps of 84 mm. The short model magnet was designed, built, and successfully tested at liquid nitrogen temperature. This magnet works in a persistent current mode, which provides additional cost savings when used in particle storage rings operated at a stable magnetic field. The results of design, fabrication, and tests are presented and discussed. The magnet demonstrated a high magnetic field stability in both apertures, efficiency of correction coils, and primary powering circuit.

Kashikhin, Vladimir [Fermilab] (ORCID:000000017249↗

High-efficiency, large-aperture fifth-harmonic: Generation of 211-nm pulses in ammonium dihydrogen phosphate crystals for fusion diagnostics

High-energy ultraviolet (UV) sources are required to probe hot dense plasmas from fusion experiments by using Thomson scattering resulting from the lower self-generated background from the plasma in the 180 to 230-nm spectral region. Although recently we demonstrated efficient, joule-class fifth harmonic conversion of 1053-nm pulses using a cesium lithium borate (CLBO) crystal, larger crystals are necessary for increased UV energy. This paper presents an alternative approach for fifth-harmonic generation of a large-aperture neodymium laser using ammonium dihydrogen phosphate (ADP). An Nd:YLF laser was optimized to produce square pulses with a flattop, square beam profile (1053 nm, 1 to 2.8 ns, 12 x 12 mm, ≤1.5 J, ≤5 Hz). Noncritical phase matching in ADP suitable for sum–frequency mixing the fourth harmonic with residual fundamental light was achieved by cooling the crystal (65 x 65 x 10 mm) in a two-chamber cryostat to 200 K. The crystal chamber used helium (1 atm) as the thermally conductive medium between the crystal and the crystal chamber, which in turn was surrounded by a high-vacuum chamber that contained a liquid nitrogen reservoir to cool the crystal chamber. Temperature variation of 0.4 K across the crystal aperture was obtained using two 50-W heaters with active feedback. The total conversion efficiency from the fundamental to the fifth harmonic, including surface losses and absorption, was 26%.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

SU-E-T-282: Remove Field-Size Limitation Using the Combination of Collimator Rotation and Jaw Tracking with MLC Aperture

Purpose: this study is to investigate the use of variable-collimators and/or collimator-rotation to overcome the field-size limitation on TrueBeamSTX. Methods: The maximum static field-size is 22- × 40-cm for TrueBeamSTX and 40- × 40-cm for Trilogy. Maximum displacement between adjacent leaf ends at a single carriage position is 15-cm for TBSTX and 14-cm for Trilogy. Our current practice for IMRT treatment at Trilogy is as follows, if MLC leaves travel more than 13.5 cm in the MLC traveling direction, the treatment fields will be split at isocenter to two groups of IMRT fields to cover the large tumors. However, TrueBeamSTX is not limited in this way because the jaws can track each segments of the MLC aperture. Radiation treatment plans for ten patients (different tumor sites) treated at Trilogy with one dimension of the field is greater than 22 cm and the other dimension is less than or equal to 22 cm. All the plans will be converted with jaws tracking each segment's MLC aperture. If necessary, the collimator rotation will also be applied for the planning. Comparison of the converted plans with the original clinical plans will be evaluated and based on the following criterion: (1) tumor coverage; (2) dose sparing to the critical structures; and (3) treatment time. Results: The tumor coverage is compatible between two plans. The dose of critical structures was evaluated in the cumulative DVH for spinal cord, parotids, and brainstem at V20 and V5. In all patients, the maximum reduction in V20 was never more than 5% and was typically less than 1%. In V5, the maximum reduction was 10% and 3% respectively. The significant difference can be found in using the variable collimator to shorten the treatment time. Conclusion: We conclude that we will use the variable-collimator for all IMRT cases on TrueBeamSTX and as a potential backup machine for Trilogy.

60 APPLIED LIFE SCIENCES↗

SU-C-201-03: Coded Aperture Gamma-Ray Imaging Using Pixelated Semiconductor Detectors

Purpose: Improved localization of gamma-ray emissions from radiotracers is essential to the progress of nuclear medicine. Polaris is a portable, room-temperature operated gamma-ray imaging spectrometer composed of two 3×3 arrays of thick CdZnTe (CZT) detectors, which detect gammas between 30keV and 3MeV with energy resolution of <1% FWHM at 662keV. Compton imaging is used to map out source distributions in 4-pi space; however, is only effective above 300keV where Compton scatter is dominant. This work extends imaging to photoelectric energies (<300keV) using coded aperture imaging (CAI), which is essential for localization of Tc-99m (140keV). Methods: CAI, similar to the pinhole camera, relies on an attenuating mask, with open/closed elements, placed between the source and position-sensitive detectors. Partial attenuation of the source results in a “shadow” or count distribution that closely matches a portion of the mask pattern. Ideally, each source direction corresponds to a unique count distribution. Using backprojection reconstruction, the source direction is determined within the field of view. The knowledge of 3D position of interaction results in improved image quality. Results: Using a single array of detectors, a coded aperture mask, and multiple Co-57 (122keV) point sources, image reconstruction is performed in real-time, on an event-by-event basis, resulting in images with an angular resolution of ∼6 degrees. Although material nonuniformities contribute to image degradation, the superposition of images from individual detectors results in improved SNR. CAI was integrated with Compton imaging for a seamless transition between energy regimes. Conclusion: For the first time, CAI has been applied to thick, 3D position sensitive CZT detectors. Real-time, combined CAI and Compton imaging is performed using two 3×3 detector arrays, resulting in a source distribution in space. This system has been commercialized by H3D, Inc. and is being acquired for various applications worldwide, including proton therapy imaging R&D.

60 APPLIED LIFE SCIENCES↗

SU-F-I-53: Coded Aperture Coherent Scatter Spectral Imaging of the Breast: A Monte Carlo Evaluation of Absorbed Dose

Purpose: Coherent scatter based imaging has shown improved contrast and molecular specificity over conventional digital mammography however the biological risks have not been quantified due to a lack of accurate information on absorbed dose. This study intends to characterize the dose distribution and average glandular dose from coded aperture coherent scatter spectral imaging of the breast. The dose deposited in the breast from this new diagnostic imaging modality has not yet been quantitatively evaluated. Here, various digitized anthropomorphic phantoms are tested in a Monte Carlo simulation to evaluate the absorbed dose distribution and average glandular dose using clinically feasible scan protocols. Methods: Geant4 Monte Carlo radiation transport simulation software is used to replicate the coded aperture coherent scatter spectral imaging system. Energy sensitive, photon counting detectors are used to characterize the x-ray beam spectra for various imaging protocols. This input spectra is cross-validated with the results from XSPECT, a commercially available application that yields x-ray tube specific spectra for the operating parameters employed. XSPECT is also used to determine the appropriate number of photons emitted per mAs of tube current at a given kVp tube potential. With the implementation of the XCAT digital anthropomorphic breast phantom library, a variety of breast sizes with differing anatomical structure are evaluated. Simulations were performed with and without compression of the breast for dose comparison. Results: Through the Monte Carlo evaluation of a diverse population of breast types imaged under real-world scan conditions, a clinically relevant average glandular dose for this new imaging modality is extrapolated. Conclusion: With access to the physical coherent scatter imaging system used in the simulation, the results of this Monte Carlo study may be used to directly influence the future development of the modality to keep breast dose to a minimum while still maintaining clinically viable image quality.

60 APPLIED LIFE SCIENCES↗

Characterization of a multi-kW, large-aperture gas-cooled Faraday rotator

We characterize a large-aperture gas-cooled Faraday rotator (FR) designed to mitigate stress-induced depolarization in high-energy, high-power laser systems. The rotator, based on ceramic TGG, was tested using a 150 mW probe beam at 1047 nm and a pump beam at 1070 nm. Compensating for the birefringence induced by the surrogate depolarization plate at 3.3 kW of effective pump power, the rotator reduces the spatially in-homogeneous depolarized light containing linear, circular, and elliptical polarization states to nearly linear with approximately 0.8% (or −21 dB) of residual depolarized energy. The FR demonstrated effective depolarization compensation across its 58×58 mm 2 aperture.

47 OTHER INSTRUMENTATION↗