Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “volume visualization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Assessment of Uncertainties in Treatment Planning for Scanned Ion Beam Therapy of Moving Tumors

Purpose: To provide methods for quantification of uncertainties in 4-dimensional (4D) treatment during treatment planning. Methods and Materials: Uncertainty information was generated by multiple 4D treatment simulations with varying parameters. Sampled data were analyzed using uncertainty visualization methods that have been added to common treatment plan evaluation methods (eg, dose-volume histogram and dose distribution analysis). To illustrate the potential of the introduced methods, uncertainty analysis was completed for a single lung cancer case using 3 motion mitigation techniques: gating, slice-by-slice rescanning, and breath-controlled rescanning. Results: By repeating 4D dose calculations with varying parameters, we were able to show local uncertainties in dose distributions and to evaluate the stability of treatment setups. The new methods were found suitable for uncertainty evaluation in 4D treatment planning of moving tumors. Calculation time of the uncertainty base data was time consuming but contrivable overnight. Conclusions: Uncertainty analysis and visualization for 4D treatment planning provide an important tool in the decision process for an optimal treatment approach.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Gamma Knife Radiosurgery for Choroidal Hemangioma

Purpose: Patients with choroidal hemangioma (CH), a benign ocular hamartoma, frequently presents with visual disturbance as a result of exudative retinal detachment (RD), which originates in subretinal fluid accumulation. We report our experience using the Leksell Gamma Knife in the management of symptomatic CH. Methods and Materials: Seven patients with symptomatic CH (circumscribed form in 3 patients and diffuse form in 4) were treated with the Leksell Gamma Knife at our institution during a 7-year period. All patients presented with exudative RD involving the macula that resulted in severe visual deterioration. The prescription dose to the target margin was 10 Gy in all cases. The mean tumor volume receiving the prescription dose was 536 mm{sup 3} (range, 151-1,057). The clinical data were analyzed in a retrospective fashion after a mean follow-up of 34.4 months (range, 9-76). Results: The resolution of exudative RD was achieved within 6 months, and the visual acuity of the affected eye had improved at the latest follow-up examination (p = .018) in all patients. No recurrence of exudative RD occurred. Thinning of the CHs was observed in most patients; however, symptomatic radiation toxicity had not developed in any of the patients. Conclusion: Symptomatic CHs can be safely and effectively managed with Gamma Knife radiosurgery using a marginal dose of 10 Gy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Rapid Airplane Parametric Input Design (RAPID)

RAPID is a methodology and software system to define a class of airplane configurations and directly evaluate surface grids, volume grids, and grid sensitivity on and about the configurations. A distinguishing characteristic which separates RAPID from other airplane surface modellers is that the output grids and grid sensitivity are directly applicable in CFD analysis. A small set of design parameters and grid control parameters govern the process which is incorporated into interactive software for 'real time' visual analysis and into batch software for the application of optimization technology. The computed surface grids and volume grids are suitable for a wide range of Computational Fluid Dynamics (CFD) simulation. The general airplane configuration has wing, fuselage, horizontal tail, and vertical tail components. The double-delta wing and tail components are manifested by solving a fourth order partial differential equation (PDE) subject to Dirichlet and Neumann boundary conditions. The design parameters are incorporated into the boundary conditions and therefore govern the shapes of the surfaces. The PDE solution yields a smooth transition between boundaries. Surface grids suitable for CFD calculation are created by establishing an H-type topology about the configuration and incorporating grid spacing functions in the PDE equation for the lifting components and the fuselage definition equations. User specified grid parameters govern the location and degree of grid concentration. A two-block volume grid about a configuration is calculated using the Control Point Form (CPF) technique. The interactive software, which runs on Silicon Graphics IRIS workstations, allows design parameters to be continuously varied and the resulting surface grid to be observed in real time. The batch software computes both the surface and volume grids and also computes the sensitivity of the output grid with respect to the input design parameters by applying the precompiler tool ADIFOR to the grid generation program. The output of ADIFOR is a new source code containing the old code plus expressions for derivatives of specified dependent variables (grid coordinates) with respect to specified independent variables (design parameters). The RAPID methodology and software provide a means of rapidly defining numerical prototypes, grids, and grid sensitivity of a class of airplane configurations. This technology and software is highly useful for CFD research for preliminary design and optimization processes.

Smith, Robert E.↗

Integrated Vehicle and Trajectory Design of Small Spacecraft with Electric Propulsion for Earth and Interplanetary Missions

This paper investigates the feasibility of Earth-transfer and interplanetary mission architectures for miniaturized spacecraft using emerging small solar electric propulsion technologies. Emerging small SEP thrusters offer significant advantages relative to existing technologies and will enable U-class systems to perform trajectory maneuvers with significant Delta V requirements. The approach in this paper is unique because it integrates trajectory design with vehicle sizing and accounts for the system and operational constraints of small U-class missions. The modeling framework includes integrated propulsion, orbit, energy, and external environment dynamics and systems-level power, energy, mass, and volume constraints. The trajectory simulation environment models orbit boosts in Earth orbit and flyby and capture trajectories to interplanetary destinations. A family of small spacecraft mission architectures are studied, including altitude and inclination transfers in Earth orbit and trajectories that escape Earth orbit and travel to interplanetary destinations such as Mercury, Venus, and Mars. Results are presented visually to show the trade-offs between competing performance objectives such as maximizing available mass and volume for payloads and minimizing transfer time. The results demonstrate the feasibility of using small spacecraft to perform significant Earth and interplanetary orbit transfers in less than one year with reasonable U-class mass, power, volume, and mission durations.

Spangelo, Sara↗

Visualization of Jet Impingement and Ignition in a Piston-Cylinder Chamber

The transportation sector accounts for almost a third of the United States energy consumption. We are developing predictive simulations of the complex in-cylinder processes of internal combustion engines to improve performance and decrease pollutant emissions. Using volume rendering, we provide a first look at the jet impingement and ignition inside a piston-cylinder chamber. Through the visualization, we were able to construct a complete 3D picture of the jet impingement on the piston-bowl walls leading to the formation of pockets of auto-ignition of fuel-air mixture. These auto-ignition pockets subsequently lead to flame stabilization releasing the chemical energy for conversion to useful work. A detailed physical picture of flame stabilization as provided by the visualization techniques presented in this study help in the design next-generation internal combustion engines.

91 SC - Advanced Scientific Computing Reseach (ASC↗

Quantitative investigation of sooting dynamics in droplet combustion using an automated image analysis algorithm

This paper reports an image analysis approach using a newly-developed open-source program to extract quantitative measurements of soot volume fraction (SVF) from digital video images of burning n-heptane droplets. The automated program developed in this work can analyze images of fixed and untethered droplets to quantify sooting dynamics. The images analyzed in the program were taken from experiments carried out in the Multi-user Droplet Combustion Apparatus (MDCA) onboard the International Space Station (ISS). In these experiments, video imaging of burning droplets was obtained using backlighting by a laser diode with a wavelength of 653 nm. Here, the light was collimated before it passed through the droplet and soot-containing region, after which the light was then attenuated and projected onto the camera’s sensors. This technique facilitates the measurements of SVF based on the principles of the full field light extinction method (FFLEM). The measurements provide quantitative data that reveal the sooting dynamics of liquid fuels during droplet combustion processes. The analyses of a soot-attenuating image (ISS n-heptane, untethered droplet) at an instant during the burning show that the SVF distribution has a peak at the soot shell location. It then decreases due to soot oxidation when the location is further away from the burning droplet. Regarding temporal effects on the maximum SVF (SVF max ), results show that SVF max first increases after the burning is initiated until a peak value is reached, after which SVF max decreases. The SVF max values identified in this study for n-heptane are quantitatively consistent with previously reported values for fiber-supported droplets and are reached relatively early in the burning history. n-Heptane images are also analyzed to show the effects of initial droplet sizes on the maximum soot volume fraction. Results show that SVF max decreases with increasing initial droplet size, which is consistent with visual observations of less soot formed and dimmer flame brightness as Do increases.

42 ENGINEERING↗

Perceived change in orientation from optic flow in the central visual field

The effects of internal depth within a simulation display on perceived changes in orientation have been studied. Subjects monocularly viewed displays simulating observer motion within a volume of randomly positioned points through a window which limited the field of view to 15 deg. Changes in perceived spatial orientation were measured by changes in posture. The extent of internal depth within the display, the presence or absence of visual information specifying change in orientation, and the frequency of motion supplied by the display were examined. It was found that increased sway occurred at frequencies equal to or below 0.375 Hz when motion at these frequencies was displayed. The extent of internal depth had no effect on the perception of changing orientation.

Dyre, Brian P.↗

Comparison of FDG-PET/CT and CT for Delineation of Lumpectomy Cavity for Partial Breast Irradiation

Purpose: The success of partial breast irradiation critically depends on proper target localization. We examined the use of fluorodeoxyglucose-positron emission tomography (FDG-PET)/computed tomography (CT) for improved lumpectomy cavity (LC) delineation and treatment planning. Methods and Materials: Twelve breast cancer patients underwent FDG-PET/CT on a GE Discovery scanner with a median time from surgery to PET/CT of 49 days. The LC was contoured on the CT scan by a radiation oncologist and, together with a nuclear medicine physician, on the PET/CT scan. The volumes were calculated and compared in each patient. Treatment planning target volumes (PTVs) were calculated by expanding the margin 2 cm beyond the LC, maintaining a 5-mm margin from the skin and chest wall, and the treatment plans were evaluated. In addition, a study with a patient-like phantom was conducted to evaluate the effect that the window/level settings might have on contouring. Results: The margin of the LC was well visualized on all FDG-PET images. The phantom results indicated that the difference between the known volume and the FDG-PET-delineated volume was <10%, regardless of the window/level settings. The PET/CT volumes were larger than the CT volumes in all cases (median volume ratio, 1.68; range, 1.24-2.45; p = 0.004). The PET/CT-based PTVs were also larger than the CT-based PTV (median volume ratio, 1.16; range, 1.08-1.64; p = 0.006). In 9 of 12 patients, a CT-based treatment plan did not provide adequate coverage of the PET/CT-based PTV (99% of the PTV received <95% of the prescribed dose), resulting in substantial cold spots in some plans. In these cases, treatment plans were generated which were specifically designed to cover the larger PET/CT-based PTV. Although these plans showed an increased dose to the normal tissues, the increases were modest: the non-target breast volume receiving {>=}50 Gy, lung volume receiving {>=}30 Gy, and heart volume receiving {>=}5 Gy increased by 5.7%, 0.8%, and 0.2%, respectively. The normal tissue dose-volume objectives were still met with these plans. Conclusion: The results of our study have shown that FDG-PET/CT can be used to define the LC volume. The increased FDG uptake was likely a result of postoperative inflammation in the LC. The targets defined using PET/CT were significantly larger than those defined with CT alone. Our results have shown that treatment plans can be generated to cover these larger PET/CT target volumes with only a modest increase in irradiated tissue volume compared with CT-determined PTVs.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Development of a multicomponent force and moment balance for water tunnel applications, volume 1

The principal objective of this research effort was to develop a multicomponent strain gauge balance to measure forces and moments on models tested in flow visualization water tunnels. An internal balance was designed that allows measuring normal and side forces, and pitching, yawing and rolling moments (no axial force). The five-components to applied loads, low interactions between the sections and no hysteresis. Static experiments (which are discussed in this Volume) were conducted in the Eidetics water tunnel with delta wings and a model of the F/A-18. Experiments with the F/A-18 model included a thorough baseline study and investigations of the effect of control surface deflections and of several Forebody Vortex Control (FVC) techniques. Results were compared to wind tunnel data and, in general, the agreement is very satisfactory. The results of the static tests provide confidence that loads can be measured accurately in the water tunnel with a relatively simple multicomponent internal balance. Dynamic experiments were also performed using the balance, and the results are discussed in detail in Volume 2 of this report.

Suarez, Carlos J.↗

Visual interface for space and terrestrial analysis

The management of large geophysical and celestial data bases is now, more than ever, the most critical path to timely data analysis. With today's large volume data sets from multiple satellite missions, analysts face the task of defining useful data bases from which data and metadata (information about data) can be extracted readily in a meaningful way. Visualization, following an object-oriented design, is a fundamental method of organizing and handling data. Humans, by nature, easily accept pictorial representations of data. Therefore graphically oriented user interfaces are appealing, as long as they remain simple to produce and use. The Visual Interface for Space and Terrestrial Analysis (VISTA) system, currently under development at the Naval Research Laboratory's Backgrounds Data Center (BDC), has been designed with these goals in mind. Its graphical user interface (GUI) allows the user to perform queries, visualization, and analysis of atmospheric and celestial backgrounds data.

Dombrowski, Edmund G.↗

Viewing is understanding: Graphite microstructure effects on infiltrated molten salt distribution revealed by 3D neutron tomography

Molten salt infiltration in the pore network of nuclear graphite may cause unwanted changes to graphite's local structure and mechanical and thermal properties. A detailed and comprehensive understanding of molten salt intrusion (distribution across sample cross section and penetration depth) is needed to assess its effects. Here, in this work, we report on an improved methodology for the use of neutron imaging (computed tomography) to evaluate salt penetration and distribution of a wide range of graphite grades with diverse microstructures. Neutron tomography data were acquired on the same graphite sample before and after salt intrusion; the 3D reconstructed volumes were digitally co-registered and subtracted. The difference in neutron attenuation coefficient represents direct visualization of FLiNaK (LiF–NaF–KF) salt distribution in the salt-impregnated graphite samples. This improved methodology was applied to investigate the effect of exposure times (12 h and 336 h) and of graphite microstructure when exposed to FLiNaK at 750 °C and 3 bar (gauge) pressure, starting from flowing argon at near atmospheric pressure. The results show that medium-grained and fine-grained graphites evolve to equilibrium at significantly different rates: fast salt uptake in medium-grained graphites produces salt deposits throughout the volume of graphite specimens, whereas salt infiltration in fine-grained graphites is much slower and limited to exposed surfaces.

FLiNaK infiltration↗

Segmentation of tomography datasets using 3D convolutional neural networks

Dendritic microstructures are ubiquitous in nature and are the primary solidification morphologies in metallic materials. Techniques such as X-ray computed tomography (XCT) have provided new insights into dendritic phase transformation phenomena. However, manual identification of dendritic morphologies in microscopy data can be both labor intensive and potentially ambiguous. The analysis of 3D datasets is particularly challenging due to their large sizes (terabytes) and the presence of artifacts scattered within the imaged volumes. Here, in this study, we trained 3D convolutional neural networks (CNNs) to segment 3D datasets. Three CNN architectures were investigated, including a new version of FCDenseNet which we extended to 3D. We show that using hyperparameter optimization (HPO) and fine-tuning techniques, both 2D and 3D CNN architectures outperform the previous state of the art. The 3D U-Net architecture trained in this study produced the best segmentations according to quantitative metrics (intersection-over-union of 95.56% and a boundary displacement error of 0.58 pixels), while 3D FCDense produced the smoothest boundaries and best segmentations according to visual inspection. The trained 3D CNNs are able to segment entire 852 × 852 × 250 voxel 3D volumes in only ~60 s, thus hastening the progress towards a deeper understanding of phase transformation phenomena such as dendritic solidification.

36 MATERIALS SCIENCE↗

Myocardial Imaging with CMR Parametric Mapping: Clinical Applications

Purpose of Review: Cardiovascular magnetic resonance (CMR) parametric mapping techniques enable the direct visualization and quantification of changes in myocardial T1, T2, T2* relaxation times and extracellular volume fraction. Recent updates on clinical applications of CMR parametric mapping techniques are reviewed in this article. Recent Findings: CMR parametric mapping techniques are useful in the evaluation of multiple conditions, including iron overload, amyloid infiltration, glycosphingolipid accumulation, myocardial edema, and fibrosis. An advantage of parametric mapping over conventional tissue characterization sequences is that these techniques are quantitative, allowing for standardization of measurements and assessment of longitudinal changes over time. Parametric mapping techniques are useful in clinical practice, including aiding in establishing a diagnosis, monitoring disease progression, evaluating response to therapy, and informing prognosis. Summary: This article provides a summary of the existing evidence for the clinical application of cardiac parametric mapping techniques.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Modeling of three-dimensional surfaces using high-level canonical piecewise-linear functions in cylindrical coordinates

In this paper, the potential application of the high-level canonical piecewise-linear model in the field of three-dimensional visualization is proposed. This idea emerges from the premise that a three-dimensional surface can be modeled by a continuous two-dimensional function. In this regard, the main contribution consists in providing a methodology for the construction of such function. For this purpose, the well-known algorithm used in the high-level canonical piecewise-linear model has been modified to achieve functions with greater graphing capability. One of the most notorious changes made with respect to the traditional methodology is the use of a new scheme of function domain partition. Contrary to the simplicial partitioning, in our proposal, an equally distributed angular partitioning is considered. With this, the resulting approximate function is expressed in cylindrical coordinates which overcome the typical limitation of graphs in Cartesian coordinates of only representing single-valued surfaces. Another remarkable change can be found in the range of evaluation of the function. Instead of using an open interval, in our approach, a closed interval from 0 to 2π is adopted. To support this proposal, illustrative case studies are reported. Numerical simulations demonstrate the effectiveness of this type of representation model not only in visual perception of three-dimensional surfaces, but also in more complex tasks like volume estimation.

97 MATHEMATICS AND COMPUTING↗

Synergistic foam stabilization and transport improvement in simulated fractures with polyelectrolyte complex nanoparticles: Microscale observation using laser etched glass micromodels

Inaccessibility to direct pore scale observation in hydrocarbon recovery of tight shale formations poses a great challenge to water-energy nexus initiatives and necessitates the use of high throughput technologies to emulate environmentally friendly processes. Herein, we employ a precise glass micromodel fabrication and visualization method to isolate the supercritical CO 2 bubbles surrounded by CO 2 -water lamella prepared in saline produced water stabilized with molecular complexation of zwitterionic surfactants (ZS) and polyelectrolyte complex nanoparticles (PECNP). The Selective Laser Enhanced Etching (SLE) technique was selected for micromodel simulation of high-pressure flow. Two representative designs, (1) fracture/micro-crack network 28 and (2) fracture/matrix were etched on fused silica glass with a laser printing machine and scCO 2 foam was injected to study the foamability, propagation, stability, and fluid loss properties. The highly monodispersed and uniformly distributed array of scCO 2 bubbles were detected in flow of scCO 2 foam in highly saline brine containing ionic complexes of positively charged PECNPs and ZS, whereas foam flow with the lamella containing ZS in fractures offered a noticeably large and polydisperse array of scCO 2 bubbles. scCO 2 bubble motion and deformation were traced, and local description of foam flow was visually examined. The confined array of scCO 2 bubbles stabilized by ZS in microcracks was affected by bubble growth and coalescence, whereas the super-populated array of monodispersed scC O2 bubbles with lamella containing complexes of PECNP and ZS were able to fill the channels with stable configurations within the timeframe of comparative stability measurements. The ability of complex fluid to prevent the formation damage was evaluated through fluid loss visualization in micromodels. Probing scCO 2 foam transport in homogenous porous media revealed smaller volume leak-off for scCO 2 foam containing PECNP-ZS ionic complexes.

04 OIL SHALES AND TAR SANDS↗

7-Tesla Susceptibility-Weighted Imaging to Assess the Effects of Radiotherapy on Normal-Appearing Brain in Patients With Glioma

Purpose: To evaluate the intermediate- and long-term imaging manifestations of radiotherapy on normal-appearing brain tissue in patients with treated gliomas using 7T susceptibility-weighted imaging (SWI). Methods and Materials: SWI was performed on 25 patients with stable gliomas on a 7 Tesla magnet. Microbleeds were identified as discrete foci of susceptibility that did not correspond to vessels. The number of microbleeds was counted within and outside of the T2-hyperintense lesion. For 3 patients, radiation dosimetry maps were reconstructed and fused with the 7T SWI data. Results: Multiple foci of susceptibility consistent with microhemorrhages were observed in patients 2 years after chemoradiation. These lesions were not present in patients who were not irradiated. The prevalence of microhemorrhages increased with the time since completion of radiotherapy, and these lesions often extended outside the boundaries of the initial high-dose volume and into the contralateral hemisphere. Conclusions: High-field SWI has potential for visualizing the appearance of microbleeds associated with long-term effects of radiotherapy on brain tissue. The ability to visualize these lesions in normal-appearing brain tissue may be important in further understanding the utility of this treatment in patients with longer survival.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Validation of x-ray microfocus computed tomography as an imaging tool for porous structures

X-ray microfocus computed tomography (micro-CT) is recently put forward to qualitatively and quantitatively characterize the internal structure of porous materials. However, it is known that artifacts such as the partial volume effect are inherently present in micro-CT images, thus resulting in a visualization error with respect to reality. This study proposes a validation protocol that in the future can be used to quantify this error for porous structures in general by matching micro-CT tomograms to microscopic sections. One of the innovations of the protocol is the opportunity to reconstruct an interpolated micro-CT image under the same angle as the physical cutting angle of the microscopic sections. Also, a novel thresholding method is developed based on matching micro-CT and microscopic images. In this study, titanium porous structures are assessed as proof of principle. It is concluded for these structures that micro-CT visualizes 89% of the total amount of voxels (solid and pore) correctly. However, 8% represents an overestimation of the real structure and 3% are real structural features not visualized by micro-CT. When exclusively focusing on the solid fraction in both the micro-CT and microscopic images, only an overestimation of about 5% is found.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

LANDSAT-D data format control book. Volume 5: (Payload)

The LANDSAT-D flight segment payload is the thematic mapper and the multispectral scanner. Narrative and visual descriptions of the LANDSAT-D payload data handling hardware and data flow paths from the sensing instruments through to the GSFC LANDSAT-D data management system are provided. Key subsystems are examined.

Andrew, H.↗