Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “voltage estimation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

An analysis of parameters affecting ampacity in aircraft bipolar MVDC power cables via coupled electrical, thermal, and computational fluid dynamic modelling

Abstract The next generation of aircraft, including more electric aircraft and all‐electric aircraft (AEA), requires electric power systems with high power density and low system mass specifications. Increasing the voltage of the system to the range of a few kV, medium voltage (MV), is a reasonable approach to achieving high‐power‐density and low‐system‐mass EPSs for aircraft applications. Higher voltages, however, pose many challenges for aviation MV power cables such as arcs and arc tracking, partial discharges (PDs), and thermal management. In this regard, thermal management is more challenging since heat transfer by convection is greatly reduced at wide‐body aircraft's cruising altitudes due to the reduced air pressure. In this paper, a finite element method (FEM) model is developed in COMSOL Multiphysics for an aircraft bipolar MVDC (±5 kV) power cable. Using the model, the maximum permissible cable current at a low pressure of 18.8 kPa (at an altitude of 12.2 km from sea level, the usual cruising altitude for wide‐body aircraft) is calculated. Also, an analytical model is developed based on analytical and proven empirical correlations governing conductive, radiative, and convective heat transfers at the steady state to estimate the ampacity of the bipolar cable system at reduced pressure. It was shown that the proposed analytical model can be used for atmospheric pressure and systems with a larger number of poles, expanding its range of applications. The results of the FEM and analytical models correlate at wide ranges of parameters such as ambient temperature, duct size, distance between the positive and negative pole cables, and the overall diameter of the cables. The influence of horizontal and vertical arrangement of poles is included in the analytical model. The results of this study can be used to design bipolar MVDC power cable systems for the envisaged wide‐body AEA.

Azizi, Arian↗

Proton irradiation damage and annealing effects in ON Semiconductor J-series silicon photomultipliers

Silicon photomultipliers (SiPMs) have become popular light conversion devices in recent years due to their low bias voltage and sensitivity to wavelengths emitted from common scintillating materials. These properties make them particularly attractive for resource-constrained missions such as space-based detector applications. However, the space radiation environment is known to be particularly harsh on semiconductor devices, where high particle fluences can degrade performance over time. The radiation hardness of a particular SiPM, manufactured by ON Semiconductor (formally SensL), has yet to be studied with high energy protons, which are native to the space radiation environment. As such, to study these effects we have irradiated groups of two SiPMs to four different fluences of 800 MeV protons delivered by the accelerator at the Los Alamos Neutron Science Center. Fluences of 1.68 × 10 9 , 1.73 × 10 10 , 6.91 × 10 10 , and 1.73 × 10 11 protons cm –2 , and their corresponding estimated doses of 0.15, 1.55, 6.19, and 15.5 kRad, were chosen based on estimates of the potential exposure a SiPM might receive during an interplanetary space mission lasting 10 years. We report the effects these doses have on dark current and the self-annealing time.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Cyberattack Detection and Mitigation on Central Volt‐VAr Using Circuit Law and Machine Learning

ABSTRACT In a distribution grid, voltage is maintained within a nominal range through a Volt‐VAr function that controls capacitor banks, reactive power of distributed energy resources (DER), and on‐load tap changers (OLTC). Availability of communications helps with the implementation of central Volt‐VAr control; however, it also opens the system to cyberattacks, causing voltage disturbances. Previous work has shown the adverse impacts of false data injection (FDI) on the central Volt‐VAr control; however, very few works have studied methods to detect and mitigate FDI on Volt‐VAr control. This paper addresses gaps in the detection and mitigation of FDI on the measurement packets of a central Volt‐VAr control. This work uses a two‐stage algorithm for cyberattack detection since the accuracy of a single‐stage machine learning (ML)–based detection method decreases while dealing with unseen data. The first stage is based on the verification of measurements against circuit laws, and the second stage utilizes a tree search algorithm and an ML method to detect the falsified data. This paper compares long short‐term memory (LSTM) and bidirectional LSTM (BiLSTM) as the employed ML algorithms. Finally, the mitigation algorithm replaces the falsified data with the estimated output of the ML algorithm. The effectiveness of the proposed method is tested for several cases using the IEEE 13‐bus test system in PSCAD software.

Beikbabaei, Milad [Bradley Department of Electrica↗

Harmonic cancellation within AC low voltage distribution for a realistic office environment

An increase of non-linear loads, primarily from power electronics, has substantially increased current harmonics in commercial buildings, which contributes to decreased transformer efficiency / lifespan and poor power quality. This study uses recorded power consumption data from common miscellaneous electric loads (MELs) seen in offices, combined with detailed characterizations of example MELs, to simulate harmonic cancellation within building circuits. Typically, harmonic cancellation studies assume that AC converters operate across their rated power range. However, this study finds that common MELs operate below 40% of rated power the majority of the time when not quiescent; 89% of sampled devices never operated above 60% of rated power. Simulations using these more realistic power levels indicate current-harmonic cancellation (3rd to 13th harmonic) is significantly lower than that predicted when using full-range power assumptions, resulting in minor errors for low-order harmonics and larger errors for higher order harmonics. Furthermore, increased MELs load diversity increases harmonic cancellation, but insufficiently to eliminate errors. In contrast, blending lighting loads with MELs on the secondaries of distribution transformers improves harmonic cancellation to near those predicted by traditional methods. These results indicate that realistic power levels, as well as better characterization of harmonics from typical MELs, should be used to estimate harmonic cancellation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A technoeconomic analysis of poly- and single-crystalline NMCxyz from material synthesis to battery pack design

A process model was developed for estimating the cost of manufacturing lithium nickel manganese cobalt oxide (LiNi x Mn y Co z O 2 , NMCxyz), the main cathode active material in lithium-ion batteries used for electric vehicles in the United States. The model was used to estimate the prices of NMC622, NMC811, and NMC955 with poly- and single-crystalline morphologies. The Battery Performance and Cost Model (BatPaC) was used to translate the NMC prices into battery pack prices. A decrease in cobalt content from NMC622 (20% Co) to NMC955 (5% Ni) decreases the material price by $\$$0.85/kg (−3%) due to a decrease in the cost of battery materials, which account for >60% of the total price. NMC622 only produce cheaper packs if the nickel sulfate cost is > 4 × its baseline, indicating higher nickel materials will lower pack cost under normal market conditions. Single-crystalline materials are $\$$2/kg (+8%) more expensive than their polycrystalline counterparts due to higher manufacturing costs from longer, hotter calcinations in less densely packed saggars. This increases the pack price by ∼$\$$3/kWh, assuming identical electrochemical properties. In conclusion, the single-crystalline materials could yield cheaper packs if cycled to higher upper cutoff voltages (i.e., 4.35 to 4.43 V for the single-crystalline material vs. 4.25 V for their polycrystalline counterparts).

Cost modeling↗

Quantifying Optical Loss of High-Voltage Degradation Modes in PV Modules Using Spectral Analysis [Slides]

The direct current bias for photovoltaic (PV) modules interconnected in series-strings may include both high voltage negative ("HV-") and positive ("HV+") polarity with respect to the electrical ground. Multiple degradation modes, resulting in quantifiable optical loss, were found to occur during HV-/HV+ sequential stress, including: corrosion of the external glass surface, encapsulant delamination (at its interfaces with the glass and the PV cell), internal haze formation (resulting from a chemical interaction between the glass and the encapsulant), corrosion and migration of the gridlines, and corrosion of the silicon nitride (SixNy) antireflective coating on the cell. The effects of these separate modes were examined using monolithic (e.g., glass or PV cell) and laminated-coupon (glass/encapsulant/glass or glass/encapsulant/cell/encapsulant/backsheet) specimens. Characterizations during and after unbiased accelerated testing at 85 degrees C/85% relative humidity included: spectrophotometry, optical microscopy, electron microscopy, and ellipsometry. For some module components (i.e., the glass and the SixNy coating), the optical performance was determined through iterative analysis of empirical measurements. Concentrating on just their spectral effect, a novel model was then developed to estimate the transfer of light to the PV cell and the return of light from the PV module with simultaneous degradation mechanisms, which was compared to a mini-module previously subjected to HV-/HV+ stress. The model suggests one-third of the current loss observed for the mini-module can be attributed to the optical degradation of the packaging materials. The dominant degradation modes include encapsulant delamination and corrosion of the SixNy coating. Recommendations are given so that the optical model may be improved relative to accelerated testing and validated relative to field aging.

14 SOLAR ENERGY↗

An automated and portable method for selecting an optimal GPU frequency

Power consumption poses a significant challenge in current and emerging graphics processing unit (GPU) enabled high-performance computing systems. In modern GPUs, dynamic voltage frequency scaling (DVFS) appears to be a reliable control to regulate power consumption and performance. However, the DVFS design space is large - hence, brute-force approaches are infeasible to select the optimal frequency. Furthermore, no single frequency can be universally optimal for applications with varying computational intensities. Thus, the application's complexity and the availability of a wide range of frequency settings are a challenge in selecting the optimal frequency configuration for a given GPU workload. To that end, this paper proposes a systematic approach that consists of three steps. The feature characterization study identifies the fine-grain GPU utilization metrics that influence the power consumption and execution time of a given workload. To understand the performance, power, and energy consumption behaviors of a workload across GPU's DVFS design space, we derived analytical power and performance models using the identified fine-grain features. Here, it is shown that the same set of GPU utilization metrics can estimate both the power consumption and execution time while being agnostic of changes to frequency and input sizes. Applying a power control with the single objective of reducing power may cause performance degradation, leading to more energy consumption. A multi-objective approach is proposed to select the optimal GPU DVFS configuration for a workload that reduces power consumption with negligible degradation in performance. The evaluation was conducted using SPEC ACCEL benchmarks and three real applications - NAMD LAMMPS, and LSTM on NVIDIA GV100, GA100, and AMD MI210 GPUs. On average, real applications showed 29.6% energy savings with a performance loss of 5.2% on GA100 and 22.6% energy savings with a performance loss of 4.7% on GV100. Moreover, the proposed models are portable to real applications, GPU architectures, and vendors, and require metric collection at only the default frequency rather than all supported DVFS configurations. Additionally, we conducted a comparison between our models and the GPU assembly instructions (PTX)-based static models. The results revealed a significant reduction in the average error rates, with a decrease from 19.7% to 3.1% for power models and from 29.4% to 5.2% for performance models.

97 MATHEMATICS AND COMPUTING↗

Quantifying optical loss of high-voltage degradation modes in photovoltaic modules using spectral analysis

The direct current bias for photovoltaic (PV) modules interconnected in series-strings may include both high voltage negative (“HV-”) and positive (“HV+”) polarity with respect to the electrical ground. Multiple degradation modes, resulting in quantifiable optical loss, were found to occur during HV-/HV+ sequential stress, including corrosion of the external glass surface, encapsulant delamination (at its interfaces with the glass and the PV cell), internal haze formation (resulting from a chemical interaction between the glass and the encapsulant), corrosion and migration of the gridlines, and corrosion of the silicon nitride (Si x N y ) antireflective coating on the cell. The effects of these separate modes were examined using monolithic (e.g., glass or PV cell) and laminated-coupon (glass/encapsulant/glass or glass/encapsulant/cell/encapsulant/backsheet) specimens. Characterizations during and after unbiased accelerated testing at 85°C/85% relative humidity included spectrophotometry, optical microscopy, electron microscopy, and ellipsometry. For some module components (i.e., the glass and the Si x N y coating), the optical performance was determined through iterative analysis of empirical measurements. Concentrating on just their spectral effect, a novel model was then developed to estimate the transfer of light to the PV cell and the return of light from the PV module with simultaneous degradation mechanisms, which was compared with a mini-module previously subjected to HV-/HV+ stress. Here the model suggests that one third of the current loss observed for the mini-module can be attributed to the optical degradation of the packaging materials. The dominant degradation modes include encapsulant delamination and corrosion of the Si x N y coating. Recommendations are given so that the optical model may be improved relative to accelerated testing and validated relative to field aging.

14 SOLAR ENERGY↗

Preconceptual Designs of Coupled Power Delivery between a 4-Loop PWR and 100-500 MWe HTSE Plants

This study develops a preconceptual design for the integration between a large-scale high-temperature electrolysis facility and a NPP. Two hydrogen facility sizes are considered: 100 MWnom and 500 MWnom. Both steam supply designs use cold reheat steam extraction as a heat source. A reboiler inside the protected area of the power plant transfers steam heat to the demineralized water supply for the hydrogen plant. After the heat transfer, the extracted steam condenses and returns to the condenser while the process steam routes out of the protected area to the electrolyzers. Electrical power is tapped off from the high voltage side of the GSU transformer, where it is then transported via a 345-kV transmission line to the hydrogen facility. Circuit breakers and disconnects are located at both ends of the transmission line. Step down transformers and miscellaneous switchgear/buses are located at the end of the transmission line inside the HTEF boundary. Control capabilities for the steam interfacing equipment and electrical dispatch are accessible from the Main Control Room, and protective relays for the transmission line are located inside the Relay Room. Computer modeling was performed for the thermal and electrical designs. PEPSE analysis provided the steady-state parameters for thermal extraction from the turbine cycle. These parameters were used to inform transients and size equipment in combination with Applied Flow Technology (AFT) Arrow and AFT Fathom modeling for steam and water piping, respectively. Electrical transients were analyzed using PSCAD. An ETAP model was used to evaluate power flow and short circuit, which enabled the sizing of transformers and protective equipment. A cost estimate was developed for both integration designs when considering plant separation distances of 250 m and 500 m. From these estimates, the modifications for thermal and electrical interfacing of a first-of-a-kind nuclear-integrated hydrogen facility are anticipated to cost between $60–250/kWnom., where the subscript “nom” refers to the nominal size of the hydrogen plant. On a thermal power basis, the thermal power has a cost of approximately $8/MWth for a 500 MWnom high temperature electrolysis plant located 500 m distant from the NPP. That value decreases to approximately $7.5/MWth for a 250 m separation distance between the hydrogen plant and the NPP. This value is lower than previous estimates of the cost of heat extracted from NPPs primarily because in this work the steam is extracted from cold reheat instead of the main steam line, which reduces the cost of the dispatched steam by approximately $3.5/MWth. Nuclear steam extraction can provide a profit avenue for many plants and is not restricted to hydrogen production. Ammonia production, oil refining, and paper production, among other industrial processes all require thermal energy, which can be provided by NPPs. Future work should look further at the details of thermal extraction for a variety of use cases. This can include increased levels of extraction and multiple simultaneous users. Additionally, site-specific studies should be performed to develop industry experience and improve cost accuracy.

08 HYDROGEN↗

Integration of fixed-frequency and FM-CW (frequency-modulated continuous-wave) reflectometers for coincident turbulence measurements on LTX- β (Lithium Tokamak eXperiment- β )

The fixed-frequency and frequency-modulated continuous-wave (FM-CW) reflectometers on LTX-β (Lithium Tokamak eXperiment-β) have been configured to use the same transmission lines and antenna arrays for coincident views of the core and edge plasma. The fixed-frequency channels (13.1–20.5 and 20–40 GHz, tunable between discharges) provide time-resolved measurements of density fluctuations, while the FM-CW channels (13.1–20.2 and 19.5–33.5 GHz) measure the density profile and fluctuations, with high spatial resolution and a sampling rate determined by the frequency sweep interval (5 μs). Data from both reflectometers are synchronously acquired to simultaneously leverage the wide bandwidth and high spatial resolution of the respective systems. Experiments showed that mutual crosstalk interference is momentary and does not diminish the capability of either system. Spectral analysis indicated broad power spectra (several hundreds of kHz) and suggests that the signals from the FM-CW system are consistent with under-sampled fixed-frequency signals. Radial correlations were explored using data from the two reflectometers, as well as from the FM-CW system alone. The core channels showed high levels of agreement between these two comparisons, suggesting that the data from the reflectometers are interchangeable for statistical estimates. For the edge channels, comparisons using data from the FM-CW reflectometer alone showed significant decorrelation due to time lag caused by the finite frequency up-sweep duration. Alternatively, this effect is eliminated when cross-correlating data from the different reflectometers. Finally, these results highlight the advantages of operating the fixed-frequency and FM-CW reflectometers in this manner, where the combined system can overcome the limitations of each separate system.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Search for lightly ionizing particles in superCDMS and simulation of neutron backgrounds

The Super Cryogenic Dark Matter Search (SuperCDMS) is a direct-detection dark matter search experiment that primarily aims to search for Weakly Interacting Massive Particles (WIMPs) using state-of-the-art solid-state detection technology. During its operation at the Soudan underground laboratory, germanium detectors were operated with high bias voltage mode known as the CDMS low ionization threshold experiment (CDMSlite) to achieve below-keV thresholds. CDMSlite, for being able to measure small energy depositions in detectors, also provides sensitivity to Lightly Ionizing Particles (LIPs) with very small fractional charges. This thesis will discuss an analysis to search LIPs with the data acquired in CDMSlite mode. An important component for LIPs search is the expected energy-deposition distributions for LIPs falling on the CDMSlite detector. In this thesis, a simulation framework to calculate the energy-deposition distributions is developed. This thesis presents first direct-detection limits on the intensity of cosmogenic LIPs with electric charges smaller than e/(3 × 105) as well as the strongest limits for charges ≤ e/160, with a minimum intensity of 1.36 × 10-7 cm-2s-1sr-1 at charge e/160.In any rare-event search experiment, understanding background is crucial. Neutrons capable of mimicking dark matter signals are a major background for any dark matter search experiment. A simulationmore » study to estimate the neutron background for an India based dark matter search experiment at Jaduguda Underground Science Laboratory (JUSL) is performed. The experiment at JUSL will be the first phase of a proposed Dark matter search at India-based Neutrino Observatory (DINO). It will be a direct detection experiment with primary aims to search for WIMPs as dark matter candidates. In this thesis, we discuss the methodology of estimating neutron flux at JUSL and report the results. The total neutron flux reaching the laboratory above 1 MeV energy threshold is found to be 5.76(±0.69) × 10-6 cm-2s-1. The impact of neutron background on the sensitivity of the experiment to detect dark matter at JUSL is also discussed. The thesis is organized as follows. Chapter 1 provides a brief introduction to the Lightly Ionizing Particle (LIPs). The analysis to search LIPs in SuperCDMS is briefly outlined in the chapter. This chapter also discusses the importance of neutron background estimates in a dark matter search experiment, more specifically, in the context of a proposed India-based dark matter search experiment at Jaduguda Underground Science Laboratory. In Chapter 2, the SuperCDMS experiment is introduced. In Chapter 3, the framework developed to perform simulations for Lightly Ionizing Particles is presented. In Chapter 4, the LIPs search analysis with the CDMSlite data and the results are discussed. In Chapter 5, the simulation of neutron background and the feasibility of dark-matter search at JUSL is discussed. Finally, conclusions from all the results discussed in this thesis are presented in Chapter 6.« less

Banik, Samir↗

Search for Lightly Ionizing Particles in SuperCDMS and simulation of neutron backgrounds

The Super Cryogenic Dark Matter Search (SuperCDMS) is a direct-detection dark matter search experiment that primarily aims to search for Weakly Interacting Massive Particles (WIMPs) using state-of-the-art solid-state detection technology. During its operation at the Soudan underground laboratory, germanium detectors were operated with high bias voltage mode known as the CDMS low ionization threshold experiment (CDMSlite) to achieve below-keV thresholds. CDMSlite, for being able to measure small energy depositions in detectors, also provides sensitivity to Lightly Ionizing Particles (LIPs) with very small fractional charges. This thesis will discuss an analysis to search LIPs with the data acquired in CDMSlite mode. An important component for LIPs search is the expected energy-deposition distributions for LIPs falling on the CDMSlite detector. In this thesis, a simulation framework to calculate the energy-deposition distributions is developed. This thesis presents first direct-detection limits on the intensity of cosmogenic LIPs with electric charges smaller than e /(3 × 10 5 ) as well as the strongest limits for charges ≤ e /160, with a minimum intensity of 1.36 × 10 -7 cm -2 s -1 sr -1 at charge e /160.In any rare-event search experiment, understanding background is crucial. Neutrons capable of mimicking dark matter signals are a major background for any dark matter search experiment. A simulation study to estimate the neutron background for an India based dark matter search experiment at Jaduguda Underground Science Laboratory (JUSL) is performed. The experiment at JUSL will be the first phase of a proposed Dark matter search at India-based Neutrino Observatory (DINO). It will be a direct detection experiment with primary aims to search for WIMPs as dark matter candidates. In this thesis, we discuss the methodology of estimating neutron flux at JUSL and report the results. The total neutron flux reaching the laboratory above 1 MeV energy threshold is found to be 5.76(±0.69) × 10 -6 cm -2 s -1 . The impact of neutron background on the sensitivity of the experiment to detect dark matter at JUSL is also discussed. The thesis is organized as follows. Chapter 1 provides a brief introduction to the Lightly Ionizing Particle (LIPs). The analysis to search LIPs in SuperCDMS is briefly outlined in the chapter. This chapter also discusses the importance of neutron background estimates in a dark matter search experiment, more specifically, in the context of a proposed India-based dark matter search experiment at Jaduguda Underground Science Laboratory. In Chapter 2, the SuperCDMS experiment is introduced. In Chapter 3, the framework developed to perform simulations for Lightly Ionizing Particles is presented. In Chapter 4, the LIPs search analysis with the CDMSlite data and the results are discussed. In Chapter 5, the simulation of neutron background and the feasibility of dark-matter search at JUSL is discussed. Finally, conclusions from all the results discussed in this thesis are presented in Chapter 6.

Banik, Samir↗

Quantifying Properties for a Mechanistic, Predictive Understanding of Aqueous Impact on Aging of Medium and Low Voltage AC and DC Cabling in Nuclear Power Plants

To address the gap in knowledge in understanding degradation in relevant service conditions, this project aimed to develop a mechanistic, predictive model of medium and low voltage cable failure based on the primary environmental degradation parameters of aqueous immersion time, temperature, and the oxidation extent. To do so, we took a two-fold approach toward evaluating degradation as related to the aqueous condition. First, we evaluated the chemical, mechanical, and electrical properties of polymers that comprise the cabling insulation under varied aqueous conditions at different temperatures. Secondly, we evaluated the performance of insulation materials under similar accelerated aging conditions in addition to the dielectric breakdown of the cabling under submersion conditions. Thermal oxidation and immersion of LDPE thin films were done using a Parr vessel and the extent of oxidation was monitored using the carbonyl index from ATR-FTIR spectrum, a ratio quantifying the carbonyl functionality produced on the LDPE film surface. Increasing the temperature, oxidation time, and oxygen pressure increased the water-vapor permeability and the carbonyl content. Thermogravimetric analysis of the films confirmed that there is indeed an initial weight loss of the smaller molecular weight molecules and volatiles. At higher temperatures, there is a secondary mass loss. Up to 70°C, the mass loss curves were similar until 80°C, when the aged films decreased at a much greater rate with respect to increasing temperature. This was seen in the 10, 50, 90% weight loss temperatures. The mechanical properties of sheet PP and HDPE as well as injection molded LDPE, HDPE, HDPP dog bones were plotted with respect to the time spent in the Parr vessel during thermal oxidation. For the sheet PP and HDPE, the UTS and the modulus of elasticity decreased while the elongation increased. The injection-molded LDPE, HDPE, and HDPP dog bones experienced a similar trend where the changes in the properties were within experimental uncertainty. This analysis of LDPE in dry and immersive oxygen-rich environments is an important baseline for future experiments looking at other degradation mechanisms. A predictive aging model for low-density polyethylene insulative cable housings was developed. This model revealed a combination of physical and chemical processes which lead to an increase in permeability and a decrease in strength of the insulator. In creating this predictive model, a gap of knowledge in the literature was revealed in two areas: understanding how the crystallinity of a polymer changes with time and visualizing the predicted pores formed through the insulator which leads to failure. Developing and using an adapted ATR-FTIR method, crystallinity was monitored and compared to bulk crystallinity found via DSC. Inhomogeneity in crystallinity changes were observed but the FTIR method but was found to be less reliable. Pore visualization was found utilizing electrical impedance spectroscopy saturated aged polyethylene films with synthesized citrate-capped gold nanoparticles, and chloroauric acid precursor. results indicate a decreasing impedance of the polyethylene films caused by the transport of ions through the film. SEM imaging was then performed for elemental analysis of the films and counter electrodes for the presence of ions. Chloride and gold ions were detected; however, no nanoparticles were found. This gives an estimated pore size of at least 0.3 nm through the aged film. Cyclic submergence of polyethylene and polypropylene in aqueous solutions of copper sulfate and Harrison’s solution were examined. It was discovered that aging in these mixed conditions and at 90°C did cause a small, yet significant increase to tensile strength for both unaged polyethylene and polypropylene. The PE and PP in cycled and submerged conditions did not have tensile strengths significantly different from dry-aged after 16 weeks. For both solutions, it was determined that capacitance increases with both water tree depth and cable temperature and is relatively independent of changing water tree AR. As for resistance, there is no apparent change between depth percentages of 10 and 80 for both solutions. This is because the water tree has not yet entered the conductor and thus there is no shorting current flowing through the tree yet. Between 80 and 100% water tree depth, it is observed that for both solutions there is a rapid decrease in resistance because the tree is now impacting the conductor shield and allowing shorting current to flow through it. The relationship between resistance and temperature was found to be inversed. As temperature increases, resistance decreases for both water tree solutions with distilled water having the most apparent difference across the range of temperatures simulated. With regards to water tree AR, resistance was found to be relatively independent at depth percentages of 10, 50, and 70, but there was some relationship at 100% depth for both solutions. At this depth, as water tree AR increased, resistance was found to also increase. Through the examination of voltage and electric field distribution plots, it was confirmed for EPR cables that increasing water tree depth leads to increasing distortion. The increase in shorting current at 100% depth for aqueous copper sulfate compared to distilled water was also visualized. Lastly, the relationship between shorting current and temperature for narrow water trees was visualized and validated using the distribution plots. This study has led to a better understanding of the effect of cable temperature, water tree solution, and geometry of the tree region on cable degradation. Furthermore, this study has documented simulation results of water tree degradation in EPR MV cables, which had been previously lacking in information. Future work in this area will add frequency into the mix and examine what effect it has on the rate of cable degradation as a result of water treeing. To compliment the work being carried by UMD on different polymer chemistries, harvested medium voltage (MV) cables were selected for accelerated aging study at ORNL. These medium voltage cables are representative of the vintages and materials that are currently in use at existing nuclear power plants (NPPs). These cables were immersed in water at 90°C and energized for a period of two years at elevated voltage. Partial discharge was measured during this period of time to track potential degradation. Unfortunately, due to the absence of failure, the extent of integration between the UMD techniques and the harvested MV insulation was limited. However, based on the findings and from the UMD research in the previous sections on polyethylene and polypropylene, follow-on characterization for harvested MV cable insulation should focus on sample preparation to take advantage of the UMD techniques to better understand mechanistic degradation in MV cable insulations. This would include: 1.) Utilization of solutions and impedance measurement insulation to track permeability in harvested and accelerated aging insulation samples, 2.) Adaptation of gold nanoparticle synthesis for electrical impedance spectroscopy with supporting SEM characterization to study pore formation in harvested and accelerated aged insulation samples, & 3.) ATR-FTIR crystallinity with multiple temperature dependent harvested MV cable insulation under different air and submerged accelerated aging. In addition, low voltage dielectric spectroscopy and high voltage dissipation factor, tan δ, could be implemented as a condition monitoring tool for harvested MV cable insulation in submerged environments.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Stochastic Microgrid Scheduling With Chance‐Constrained Resilience Consideration

Traditionally, it is assumed that microgrids transition seamlessly from grid‐connected operation to islanded mode in the event of sudden main grid outages. In reality, the islanding process, especially unintentional islanding, is rarely seamless. Instead, it is subject to voltage and frequency fluctuations caused by the instantaneous disconnection of the point of common coupling (PCC) switch, variations in loads and renewable generation output and even the protection tripping of distributed energy resources (DERs). To mitigate these fluctuations and facilitate a smooth islanding process, we propose a stochastic microgrid scheduling model that incorporates chance‐constrained resilience measures. Specifically, the resilience measure is defined as the probability of successful islanding (PSI), that is, the probability that a microgrid can mitigate the generation‐demand imbalance caused by the disconnection of the PCC switch, variations in load and renewable generation and DER tripping. This measure is modelled using chance constraints. Unlike existing reliability and resilience indices, which typically neglect the possibility of microgrid/DER failure under extreme events and assume their survival while primarily focussing on reducing impact duration or magnitude, the proposed PSI‐based framework explicitly addresses microgrid and DER survival during the islanding transition. The formulated nonlinear chance constraints are approximated using a multiinterval approach and equivalently represented as a mixed‐integer linear programming (MILP) formulation. Case study results validate the proposed method, showing that the PSI estimation error is reduced to less than 8%, compared to approximately 28% with existing methods. Various sensitivity analyses on the DER tripping rate and PSI settings were performed to validate the robustness of the proposed method. In particular, the necessity of accounting for DER tripping in the PSI calculation was demonstrated.

chance constrained optimization↗

Etching of Si 3 N 4 induced by electron beam plasma from hollow cathode plasma in a downstream reactive environment

An etching system based on the interaction of electrons extracted from a direct current (DC) hollow-cathode (HC) Ar plasma and injected towards a Si3N4 covered silicon substrate located in the downstream reactive environment created by an additional remote CF 4 /O 2 plasma source was developed and evaluated. By controlling the properties of the injected beam electrons, this approach allows to deliver energy to a surface functionalized by exposure to reactive species, and initiate surface etching. The energy of the primary beam electrons is controlled by the acceleration voltage relative to the HC discharge. Ar atoms flow from the high-pressure HC discharge into the low pressure downstream reactive environment in the process chamber. For an acceleration voltage greater than the ionization potential of Ar and/or process gas species, the energetic primary beam electrons produce a secondary plasma in the process chamber, and can also cause additional dissociation. We have characterized the properties of the secondary plasma and also surface etching of Si 3 N 4 as a function of process parameters, including acceleration voltage (0-80 V), discharge current of the HC discharge (1-2 A), pressure (3.5-20 mTorr), source to substrate distance (1.5 to 5 cm), and feed gas composition (20% and 80% O2 in CF 4 /O 2 ). The electron energy probability function (EEPF) measured with a Langmuir probe about 2.5 cm below the extraction ring suggests several major groups of electrons for this situation, including high energy primary beam electrons with an energy that varies as the acceleration voltage is changed and low energy electrons produced by beam electron-induced ionization of the Ar gas in the process chamber. When a remote CF 4 /O 2 plasma is additionally coupled to the process chamber, Si 3 N 4 surfaces can be functionalized, and by varying the energy of the beam electrons, Si 3 N 4 etching can be induced by electron-neutral synergy effect with plasma-surface interaction. For conditions without beam electron injection, the remote plasma etching rate (ER) of Si 3 N 4 depends strongly on the O 2 concentration in the CF 4 /O 2 processing gas mixture and can be suppressed for O 2 -rich process conditions by the formation of a SiONF passivation layer on the Si 3 N 4 surface. The combination of the HC electron beam source with the remote plasma source (HCEB-RP) makes it possible to induce Si 3 N 4 etching for O 2 -rich remote plasma conditions where remote plasma by itself produces negligible Si 3 N 4 etching. The electron enhanced etching of Si 3 N 4 depends strongly on O 2 /CF 4 mixing ratio reflecting changing arrival rates of O and F species at the surface. Optical emission spectroscopy was used to estimate the ratio of gas phase F and O densities and found to be controlled by the gas mixing ratio and independent of HC EB operating conditions. At this time the detailed sequence of events operative in the etching mechanism is unclear. While the increase of the electron energy is ultimately responsible for initiating surface etching, at present we cannot rule out a role of ions from the simultaneously produced secondary plasma in plasma surface interaction mechanisms.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Semi-Supervised, Non-Intrusive Disaggregation of Nodal Load Profiles With Significant Behind-the-Meter Solar Generation

It is of imperative interests for regional transmission organizations (RTOs) to effectively extract actual load profiles at transmission nodes with significant behind-the-meter solar generation, which remains a gap in the existing technology paradigm. This paper proposes an explicit yet efficient linear estimator to disaggregate actual load profiles at transmission buses with significant behind-the-meter (BTM) solar generations. The proposed estimator is based on disaggregating (i.e., extracting) at locations close to transmission buses under consideration. Further, to overcome the lack of “ground truth” and validate the performance of the proposed algorithms, we first propose semi-supervised mechanisms with parameter tuning as well as unsupervised clustering and leverage the unique characteristics of zero-crossing points in BTM solar peaking behaviors, which we refer to as “Zone-to-Node (Z2N)” methods. Next, we further propose a bi-level Node-to-Node (N2N) framework that improves the overall disaggregation performances compared to Z2N. Numerical results are presented using real-world data at PJM Interconnection.

14 SOLAR ENERGY↗

Operation at Reduced Atmospheric Pressure and Concept of Reliability Redundancy for Optimized Design of Insulation Systems

Electrified transportation is calling for insulation design criteria that is adequate to provide elevated levels of power density, power dynamics and reliability. Increasing voltage levels are expected to cause accelerated intrinsic and extrinsic aging effects which will not be easily predictable at the design stage due to a lack of suitable modeling. Designing reliable insulation systems would require finding solutions able to control accelerated aging due to an unpredictable increase of intrinsic stresses and the onset of extrinsic stresses as partial discharges. This paper proposes the concept of reliability redundancy for the insulation design of aerospace electrical asset components, which is also validated at lower-than-standard atmospheric pressure. The principle is that extrinsic-aging-free design might be achieved upon determining the aging stress or abnormal service stresses distribution and being sure that aging will not generate conditions that can incept extrinsic aging (partial discharges) during operation life. However, such information is never, in practice, fully available to insulation system designers. Hence, especially in critical applications such as electrified aircraft, aerospace, and combat ships a further level of reliability should be added to a partial-discharge-free design, which can consist of the use of corona-resistant materials and/or of life models able to consider the accelerated aging effect of partial discharges (or any other type of extrinsic-accelerated aging factor). Innovative life modeling considering both extrinsic and intrinsic aging stresses, insulating material testing to estimate model parameters, and a metric for quantifying the extent of corona (or partial discharge) resistance can lead to establishing feasibility and limit conditions for optimized or fully reliability-redundant design. It is shown in the paper that if an extrinsic-aging-free design is not feasible, and it is therefore replaced by a redundant design, a further level of reliability redundancy can be provided by effective condition monitoring plans.

Montanari, Gian Carlo↗

Zero-Valent Iron Permeable Reactive Barrier to Remediate Volatile Organic Compounds in Groundwater - 20209

The US DOE-SRS, the US EPA, and the South Carolina Department of Health and Environmental Control determined it was appropriate to perform a non-time critical removal action at the P-Area Groundwater Operable Unit at the SRS to reduce the mass and downgradient transport of trichloroethylene in the P-Area groundwater plume. Contaminated groundwater discharges to a nearby stream, Steel Creek, within the SRS boundaries, resulting in trichloroethylene concentrations above the maximum contaminant level. Impact to surface water is limited in areal extent and supported by recently collected characterization data. The P-Area Groundwater Operable Unit encompasses the groundwater beneath an industrial area within SRS, P Area, where the P-Reactor once operated. The boundaries of the P-Area Groundwater Operable Unit extend northwest to Steel Creek, northeast toward PAR Pond, and southeast to Meyers Branch. Groundwater in the Upper Three Runs Aquifer of the P-Area Groundwater Operable Unit has been impacted by reactor and facility operations between 1954 and 1991, including tritium and volatile organic compounds. The P-Area surface units contributing to groundwater contamination were remediated as part of the P-Area Operable Unit in 2011. The P-Reactor closure is one of the first of its kind in the DOE Complex and is one of only a few full-sized production reactors in the US to undergo completion of final closure activities. The nature and extent of groundwater contamination was determined using a variety of investigative approaches such as groundwater monitoring wells, direct-push technology, and surface water samples. Groundwater contamination associated with trichloroethylene is primarily exhibited in a narrow plume that extends from the source area at P-Reactor and west to Steel Creek. Maximum contaminant level exceedances in groundwater occur over an area of ∼6.9 hectares for trichloroethylene with concentrations as high as 7.7 milligrams per liter. To the west of the P-Area facility area, the trichloroethylene groundwater plume is controlled by a buried geologic feature, assumed to be an old stream bed, that further narrows the groundwater plume in what has been designated as the 'neck area.' This narrowing of the groundwater plume provides an ideal location for a treatment barrier. The non-time critical removal action alternative chosen is to install a zero-valent iron permeable reactive barrier within the neck area of the trichloroethylene groundwater plume, perpendicular to groundwater flow direction. This technology will provide a treatment barrier that will reduce trichloroethylene groundwater concentrations by 90% and has an anticipated useful life of at least 25 years. A pre-design investigation was performed in the neck area to confirm site lithology, hydrogeology, geochemistry, and extent of trichloroethylene contamination prior to a final design. A treatability study, conducted as part of the pre-design investigation, indicated that the subsurface and groundwater in the PArea Groundwater Operable Unit is compatible with the zero-valent iron and will not lead to excessive buildup from mineralization/precipitation or biofouling. Probabilistic modeling was conducted using field and laboratory data to determine the expected performance of the zero-valent iron permeable reactive barrier. The model simulations indicated that a 3.81-centimeter thick barrier would provide greater than 90% reduction of trichloroethylene groundwater concentration. The final design of the zero-valent iron permeable reactive barrier is a barrier that will extend 80.5 linear meters in a 'zigzag' orientation to best transect the trichloroethylene plume and account for varying groundwater flow. The barrier will be installed from 13.7 meters below ground surface to 41.1 meters below ground surface for 65.8 linear meters and from 13.7 meters below ground surface to 36.6 meters below ground surface for 14.6 linear meters, the base of which is 'keyed' into a low permeability zone. The barrier is designed to a thickness of 10.2 centimeters, which was determined to reduce the trichloroethylene groundwater concentrations by greater than 90% with a safety factor of 2.67. A total of approximately 689 metric tons of zero-valent iron will be injected through 22 injection wells spaced 3.66 meters apart, using guar to suspend the zero-valent iron. Zero-valent iron permeable reactive barrier construction will be monitored through 23 installed resistivity receivers offset 7.32 meters from the zerovalent iron permeable reactive barrier. The zero-valent iron will be energized with a low-voltage 100 Hertz signal during injection and will be monitored using the resistivity receivers to ensure complete coalescence of the zero-valent iron permeable reactive barrier. The zero-valent iron was sized to have a hydraulic conductivity greater than the natural subsurface, thus promoting groundwater flow through the barrier. As contaminated groundwater contacts the zero-valent iron, volatile organic compounds, including trichloroethylene, are immediately degraded to harmless compounds such as ethylene. The performance of the zero-valent iron permeable reactive barrier will be monitored using three upgradient monitoring well clusters, six downgradient monitoring well clusters, and four in-wall monitoring wells. The in-wall monitoring wells will indicate immediate reduction of trichloroethylene mass in the groundwater and allow analyses of the zero-valent iron permeable reactive barrier health. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗