Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ultrasonic”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

An ultrasonic method for studying elastic moduli as a function of temperature

Ultrasonic method is used to determine the elastic moduli of materials used in components of high-temperature nuclear reactors. An ultrasonic, pulse-echo technique determines the velocity of sound waves propogating in a heated region of rod-shaped specimens. From these velocities, the elastic moduli are calculated.

Peterson, R. G.↗

Ultrasonic metal etching for metallographic analysis

Ultrasonic etching delineates microstructural features not discernible in specimens prepared for metallographic analysis by standard chemical etching procedures. Cavitation bubbles in ultrasonically excited water produce preferential damage /etching/ of metallurgical phases or grain boundaries, depending on hardness of metal specimens.

Young, S. G.↗

Spark ultrasonic transducer

Nondestructive testing by spark transducer induces ultrasonic pulses in materials without physical contact. High power pulse generator connected to step up transformer produces sparking between two tungsten rods and ultrasonic energy pulses in test samples placed between rods.

Hoop, J. M.↗

Ultrasonic signal enhancement by resonator techniques

Ultrasonic resonators increase experimental sensitivity to acoustic dispersion and changes in attenuation. Experimental sensitivity enhancement line shapes are presented which were obtained by modulating the acoustic properties of a CdS resonator with a light beam. Small changes in light level are made to produce almost pure absorptive or dispersive changes in the resonator signal. This effect is due to the coupling of the ultrasonic wave to the CdS conductivity which is proportional to incident light intensity. The resonator conductivity is adjusted in this manner to obtain both dispersive and absorptive sensitivity enhancement line shapes. The data presented verify previous thoretical calculations based on a propagating wave model.

Heyman, J. S.↗

Ultrasonic scanning system for in-place inspection of brazed tube joints

A miniaturized ultrasonic scanning system for nondestructive in-place, non-immersion testing of brazed joints in stainless-steel tubing is described. The system is capable of scanning brazed tube joints, with limited clearance access, in 1/4 through 5/8 inch union, tee, elbow and cross configurations. The system has the capability to detect defective conditions now associated with material density changes in addition to those which are depended upon density variations. The system includes a miniaturized scanning head assembly that fits around a tube joint and rotates the transducer around and down the joint in a continuous spiral motion. The C-scan recorder is similar in principle to conventional models except that it was specially designed to track the continuous spiral scan of the tube joint. The scanner and recorder can be operated with most commercially available ultrasonic flaw detectors.

Haynes, J. L.↗

Application of ultrasonic signature analysis for fatigue detection in complex structures

Ultrasonic signature analysis shows promise of being a singularly well-suited method for detecting fatigue in structures as complex as aircraft. The method employs instrumentation centered about a Fourier analyzer system, which features analog-to-digital conversion, digital data processing, and digital display of cross-correlation functions and cross-spectra. These features are essential to the analysis of ultrasonic signatures according to the procedure described here. In order to establish the feasibility of the method, the initial experiments were confined to simple plates with simulated and fatigue-induced defects respectively. In the first test the signature proved sensitive to the size of a small hole drilled into the plate. In the second test, performed on a series of fatigue-loaded plates, the signature proved capable of indicating both the initial appearance and subsequent growth of a fatigue crack. In view of these encouraging results it is concluded that the method has reached a sufficiently advanced stage of development to warrant application to small-scale structures or even actual aircraft.

Zuckerwar, A. J.↗

Portable apparatus with CRT display for nondestructive testing of concrete by the ultrasonic pulse method

The development of methods for the nondestructive study of concrete structures is discussed. The nondestructive test procedure is based on the method of ultrasonic pulse transmission through the material. The measurements indicate that the elastic properties of concrete or other heterogeneous materials are a function of the rate of ultrasonic propagation. Diagrams of the test equipment are provided. Mathematical models are included to support the theoretical aspects.

Manta, G.↗

Contributions to the study of ultrasonic machining

Problems in the industrial application of ultrasounds are discussed. Starting from the industrial characteristics of ultrasonic working, especially of hard and fragile materials that are difficult to work by means of conventional methods, the characteristics of the feed system, the circulation system of the abrasive suspension, and the ultra-acoustic unit of machines for ultrasonic working are described. Experiments on the behavior of different types of ultra-acoustic unit design and on the optimal operating conditions connected with the manner of execution, fixation, and excitation conditions are analyzed.

Savii, G.↗

Metalworking with ultrasonic energy

The application of ultrasonic radiation for metal working of steel is discussed. It is stated that the productivity of the ultrasonic working is affected by the hardness of the material to be worked, the oscillation amplitude, the abrasive temperature, and the grain size. The factors that contribute to an increase in the dislocation speed are analyzed. Experimental data are provided to substantiate the theoretical parameters.

Sonea, I.↗

Ultrasonic examination of welded joints of great thickness in mechanical equipment under pressure

The requirements involved in choosing ultrasonic devices, the factors that affect testing, and recommended calibration methods are discussed. The ultrasonic testing method is the only method that up to now permits detection of defects in welded joints of great thickness. The results are conditioned by the performances of the devices employed as well as by the degree of instruction of the personnel.

Emil, N.↗

Ultrasonic Doppler measurement of renal artery blood flow

Implantable pulsed Doppler ultrasonic flowmeter development has resulted in designs for application to the aortas of dogs and humans, and to human renal and coronary arteries. A figure of merit was derived for each design, indicating the degree of its precision. An H-array design for transcutaneous observation of blood flow was developed and tested in vitro. Two other simplified designs for the same purpose obviate the need to determine vessel orientation. One of these will be developed in the next time period. Techniques for intraoperative use and for implantation have had mixed success. While satisfactory on large vessels, higher ultrasonic frequencies and alteration of transducer design are required for satisfactory operation of pulsed Doppler flowmeters with small vessels.

Source record↗

Computer automation of ultrasonic testing

Report describes a prototype computer-automated ultrasonic system developed for the inspection of weldments. This system can be operated in three modes: manual, automatic, and computer-controlled. In the computer-controlled mode, the system will automatically acquire, process, analyze, store, and display ultrasonic inspection data in real-time. Flaw size (in cross-section), location (depth), and type (porosity-like or crack-like) can be automatically discerned and displayed. The results and pertinent parameters are recorded.

Yee, B. G. W.↗

A transmission oscillator ultrasonic spectrometer

A continuous wave ultrasonic instrument capable of measuring very small changes in acoustic attenuation and phase velocity is described. This transmission oscillator ultrasonic spectrometer (TOUS) exhibits high sensitivity because it oscillates marginally. In spite of this high sensitivity, the TOUS system is relatively simple, compact, and inexpensive. These features suggest that the TOUS is suitable not only for precise laboratory measurements of the physical properties of materials, but also for field applications in nondestructive testing.

Conradi, M. S.↗

The feasibility of ranking material fracture toughness by ultrasonic attenuation measurements

A preliminary study was conducted to assess the feasibility of ultrasonically ranking material fracture toughness. Specimens of two grades of maraging steel for which fracture toughness values were measured were subjected to ultrasonic probing. The slope of the attenuation coefficient versus frequency curve was empirically correlated with the plane strain fracture toughness value for each grade of steel.

Vary, A.↗

Monitoring crack extension in fracture toughness tests by ultrasonics

An ultrasonic method was used to observe the onset of crack extension and to monitor continued crack growth in fracture toughness specimens during three point bend tests. A 20 MHz transducer was used with commercially available equipment to detect average crack extension less than 0.09 mm. The material tested was a 300-grade maraging steel in the annealed condition. A crack extension resistance curve was developed to demonstrate the usefulness of the ultrasonic method for minimizing the number of tests required to generate such curves.

Klima, S. J.↗

The feasibility of ranking material fracture toughness by ultrasonic attenuation measurements

A preliminary study was conducted to assess the feasibility of ultrasonically ranking material fracture toughness. Specimens of two grades of maraging steel for which fracture toughness values were measured were subjected to ultrasonic probing. The slope of the attenuation coefficient vs frequency curve was empirically correlated with the plane strain fracture toughness value for each grade of steel.

Vary, A.↗