Reaching For New Physics With MeV-scale Reconstruction In The MicroBooNE LArTPC Neutrino Detector

Large neutrino liquid argon time projection chamber (LArTPC) experiments can broaden their physics reach by reconstructing MeV-Scale energy depositions, or blips, in their data. We demonstrate new calorimetric and particle discrimination capabilities at the MeV scale using reconstructed blips in MicroBooNE LArTPC data at Fermilab. A concentration of low-energy ($<$3 MeV) blips is observed around fiberglass mechanical support struts along the TPC edges, with spectral features consistent with the Compton edge of the 2.614 MeV $^{208}$Tl decay $\gamma$ ray. With these features we perform the electron energy scale calibration to few-percent precision and yield the specific activity of $^{208}$Tl in the struts, $(11.7 \pm 0.2 \text{(stat)} \pm 2.8 \text{(syst)})$ Bq/kg. Using cosmogenic blips above 3 MeV, we demonstrate the ability of large LArTPCs to discriminate low-energy proton and electron depositions. An enriched low-energy proton sample selected with this technique is smaller in data than in dedicated CORSIKA simulations, pointing to possible mismodeling in CORSIKA incident cosmic fluxes or Geant4 particle transport. These methods are applied to MicroBooNE's inclusive single-photon search, which reported a 2.2$\sigma$ excess below 600 MeV in shower energy for events with no reconstructed protons. By identifying and classifying blips near single-photon events selected by the WireCell reconstruction framework, a more comprehensive labeling of nearby hadronic activity is established: blips upstream of the shower axis indicate previously unidentified final-state protons, while elevated blip counts at wide angles signal final-state neutrons. Taken together with MiniBooNE's long-standing low-energy excess (LEE) and MicroBooNE electron-like and sterile neutrino searches disfavored as possible explanations of the MiniBooNE anomaly, this analysis motivates an expanded exploration of the single-photon channel in Fermilab's short-baseline LArTPC program. This thesis documents the current status of this enhanced analysis, which will form a key part of MicroBooNE's final low-energy-excess results.

Andrade Aldana, Diego Armando [IIT, Chicago (main)↗

The DUNE Near Detector

DUNE is a next-generation experiment aiming to provide precision measurements of neutrino oscillation parameters. It will detect neutrinos produced in the Long-Baseline Neutrino Facility beamline at Fermilab, using a Near Detector situated near the beam target where the neutrinos originate and a Far Detector located 1300 km away in South Dakota. A comparison of the spectra of neutrinos measured at the Far and the Near Detector will allow for the extraction of oscillation probabilities from which the oscillation parameters can be inferred. The specific role of the Near Detector is to serve as the experiment’s control: it will establish the no oscillation null hypothesis, measure and monitor the beam, constrain systematic uncertainties, and provide essential measurements of the neutrino interactions to improve models. The Near Detector complex will include three primary detector components: a liquid argon time projection chamber, a high-pressure gas time projection chamber and an on-axis beam monitor. The three detectors will serve important individual and overlapping functions, with two of them being also able to move transverse to the beam’s axis via the DUNE-PRISM program. The overall mission of the Near Detector, as well as the three sub-detectors’ unique capabilities and physics programs will be discussed in these proceedings.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The design, implementation, and performance of the LZ calibration systems

LUX-ZEPLIN (LZ) is a tonne-scale experiment searching for direct dark matter interactions and other rare events. It is located at the Sanford Underground Research Facility (SURF) in Lead, South Dakota, USA. The core of the LZ detector is a dual-phase xenon time projection chamber (TPC), designed with the primary goal of detecting Weakly Interacting Massive Particles (WIMPs) via their induced low energy nuclear recoils. Surrounding the TPC, two veto detectors immersed in an ultra-pure water tank enable reducing background events to enhance the discovery potential. Intricate calibration systems are purposely designed to precisely understand the responses of these three detector volumes to various types of particle interactions and to demonstrate LZ's ability to discriminate between signals and backgrounds. In this paper, we present a comprehensive discussion of the key features, requirements, and performance of the LZ calibration systems, which play a crucial role in enabling LZ's WIMP-search and its broad science program. The thorough description of these calibration systems, with an emphasis on their novel aspects, is valuable for future calibration efforts in direct dark matter and other rare-event search experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Timing resolution and rate capability of Photonis miniPlanacon XPM85212/A1-S MCP-PMT

In this paper we report on a set of experiments that focus on measuring the timing performance of the Photonis miniPlanacon XPM85212/A1-S microchannel plate photomultiplier tubes along with the detector response at high event rates. The detector has a single photoelectron timing resolution of 30 ps at low rates ( 10 kHz ). We show that both the gain and the timing start to deteriorate around 1 MHz with 20 photoelectrons per channel at 1 0 4 target gain, giving the current per unit of area limits of 1.38 μ A / cm 2 and 2.38 μ A / cm 2 for the two tested devices. Photo-multiplier tubes with lower micro-channel plate resistivity exhibit a better rate capability due to the faster replenishment of the charge inside the microchannels. As we demonstrate, another method to improve the rate capability is to operate the photon detector tubes at a lower gain by reducing the supply voltage and compensating for the loss of amplitude by an additional amplification stage at the expense of the achieved timing resolution. The tube active area over which the beam is spread also plays a role since the same amount of light yields a better rate capability when spread over a larger area. The tubes exposed to high event rates showed an uncharacteristically slow recovery back to its initial gain with 80 % of the initial gain recovered only after several tens of minutes.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Temperature-dependent characterization of large-area superconducting microwire array with single-photon sensitivity in the near-infrared

Superconducting nanowire single photon detectors (SNSPDs) are a leading detector technology for time-resolved single-photon counting from the ultraviolet to the near-infrared regime. The recent advancement in single-photon sensitivity in micrometer-scale superconducting wires opens up promising opportunities to develop large area SNSPDs with applications in low background dark matter detection experiments. Here, we present the first detailed temperature-dependent study of a 4-channel 1×1 mm 2 WSi superconducting microwire single photon detector (SMSPD) array, including the internal detection efficiency, dark count rate, and importantly the coincident dark counts across pixels. The detector shows saturated internal detection efficiency for photon wavelengths ranging from 635 nm to 1650 nm, time jitter of about 160 ps for 1060 nm photons, and a low dark count rate of about 10 -2 Hz. Additionally, the coincidences of dark count rate across pixels are studied for the first time in detail, where we observed an excess of correlated dark counts, which has important implications for low background dark matter experiments. The results presented is the first step towards characterizing and developing SMSPD array systems and associated background for low background dark matter detection experiments.

47 OTHER INSTRUMENTATION↗

Studies of the trigger performance of the ICARUS T600 detector at Fermilab

In recent years, experimental neutrino anomalies were reported: if confirmed, they could hint at the existence of additional sterile neutrino states participating in the mixing phenomenon. The future Short-Baseline Neutrino (SBN) project at Fermilab will pursue sterile neutrino searches, by exploiting three Liquid Argon (LAr) Time Projection Chamber (TPC) detectors located on-axis along the Booster Neutrino Beam (BNB). Aside from SBND and MicroBooNE, ICARUS will be the far detector and will also be interested by the NuMI beam (off-axis). The trigger system is a key component of the detector: it is based on the coincidence of prompt signals from scintillation light in the LAr-TPC (recorded by a system of PhotoMultiplier Tubes, PMTs) with the proton spill extraction of the beam. The present system exploits a majority-based logic and may be complemented by a trigger system based on adder boards, that add the analog signals of the PMTs in groups of 15. Triggering on the sum may help in identifying events closer to the TPC walls, in which there is plenty of light collected by few PMTs and for which the majority condition may not be satisfied. Many tests were carried out to characterize the adder boards, both on the hardware and software sides.

43 PARTICLE ACCELERATORS↗

Exploring AI/ML-based Real-time Anomaly Detection in DUNE for Supernova Burst Neutrinos

The Deep Underground Neutrino Experiment (DUNE) is currently under construction with far detectors consisting of 4 liquid argon time projection chamber (LArTPC) modules at SURF (South Dakota Underground Research Facility) and a near detector complex with neutrino beam production at Fermilab to unambiguously determine neutrino mass ordering, to discover and precisely measure Charge-Parity (CP) violation phase in leptonic sector, to search for Beyond Stand Model (BSM) physics, and to study solar and supernova burst neutrinos. Anomalies in this project are classified in three categories: new physics signals, supernova burst neutrinos, and detector malfunction. We report here on promising early studies toward an Artificial Intelligence/Machine Learning-based real-time anomaly detection system, using a prototype autoencoder model currently under development. Additionally, the current status of an improved model and its performance will be presented. The model will be evaluated not only for its sensitivity to supernova neutrinos, but also to BSM physics signals and detector malfunctions. We will also consider how such a real-time algorithm might be used in DUNE.

de Jonge, Anselm [Kirchhoff Inst. Phys.] (ORCID:00↗

Calibration of the DUNE Far Detector Using Cosmic-ray Muon Events

The Deep Underground Neutrino Experiment (DUNE) aims to set new limits on parameters associated with neutrino oscillations, neutrino astrophysics, and beyond the Standard Model (SM) searches such as nucleon decay. DUNE will quantify the magnitude of CP violation in the lepton sector, and determine the neutrino mass ordering. These benefit highly from the large target mass and excellent imaging, tracking, and particle identification capabilities of Liquid Argon Time Projection Chambers (LArTPCs). Detector calibration is essential to make precise physics measurements. For instance, accurate energy reconstruction is necessary for measuring many of the aforementioned quantities with the precision required for discovering new physics and fully exploiting the capabilities of the detector. Cosmic muons are a freely available natural source of calorimetric data and can be used for calibrating various detector parameters. This thesis provides an analysis of simulated cosmic-ray muon events generated with the Muon Simulation Underground (MUSUN) generator in the DUNE horizontal drift (HD) far detector (FD). The study focuses on analysing the energy and angular distribution of various classes of muon events, as well as characterising the different particles produced by cosmic muon interactions. The analysis of π0 → 2γ events within the cosmic-ray muon sample is presented in this thesis with a detailed study of reconstructing electromagnetic showers. The π0 mass is reconstructed within the DUNE FD, yielding a value of (136 ± 7) MeV/c2. Additionally, the thesis introduces methods for dE/dx calibration using simulated and reconstructed muon tracks. A calibration constant Ccal = (5.469 ± 0.003) × 10−3 ADC × tick/e is obtained through a model-dependent calibration process, where 1 tick corresponds to 500 ns of sampling time of an ADC. Furthermore, a calibration technique is presented, demonstrating precise translation from dQ/dx to dE/dx. This calibration method is applied to stopping muons, charged pions, and protons in the DUNE FD, addressing the measurement of energy loss in the detector volume. These are important calibrations of the DUNE FD and will contribute to achieving the exciting physics goals of the experiment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Light Yield Calibration in MicroBooNE

The MicroBooNE detector is a Liquid Argon Time Projection Chamber (LArTPC) located along the Booster Neutrino Beam (BNB) at Fermilab. Its primary physics goal is to contribute to addressing the elusive short-baseline MiniBooNE low energy excess. MicroBooNE records and utilises both the ionisation charge and scintillation light produced inside the TPC to select and reconstruct neutrino interactions. The scintillation light collected using a plane of PhotoMultiplier Tubes (PMTs) is also used for accurate event timing and cosmic muon rejection with the latter being an important background for detectors, such as MicroBooNE, located on the surface. A good understanding of light modeling and its related systematic uncertainties is crucial to evaluate their impact on physics analyses. The experience acquired from MicroBooNE regarding how the stability of the scintillation light behaves and evolves during the 5 years of the primary physics run will be discussed as well as the calibration method used. This experience will help with understanding the physics of scintillation light in LArTPCs for the future long-running Short-Baseline Neutrino (SBN) and Deep Underground Neutrino Experiment (DUNE) programs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

First results on ProtoDUNE-SP liquid argon time projection chamber performance from a beam test at the CERN Neutrino Platform

The ProtoDUNE-SP detector is a single-phase liquid argon time projection chamber with an active volume of 7.2× 6.1× 7.0 m3. It is installed at the CERN Neutrino Platform in a specially-constructed beam that delivers charged pions, kaons, protons, muons and electrons with momenta in the range 0.3 GeV/c to 7 GeV/c. Beam line instrumentation provides accurate momentum measurements and particle identification. The ProtoDUNE-SP detector is a prototype for the first far detector module of the Deep Underground Neutrino Experiment, and it incorporates full-size components as designed for that module. This paper describes the beam line, the time projection chamber, the photon detectors, the cosmic-ray tagger, the signal processing and particle reconstruction. It presents the first results on ProtoDUNE-SP's performance, including noise and gain measurements, dE/dx calibration for muons, protons, pions and electrons, drift electron lifetime measurements, and photon detector noise, signal sensitivity and time resolution measurements. The measured values meet or exceed the specifications for the DUNE far detector, in several cases by large margins. ProtoDUNE-SP's successful operation starting in 2018 and its production of large samples of high-quality data demonstrate the effectiveness of the single-phase far detector design.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Accessing new physics with an undoped, cryogenic CsI CEvNS detector for COHERENT at the SNS

We consider the potential for a 10 kg undoped cryogenic CsI detector operating at the Spallation Neutron Source to measure coherent elastic neutrino-nucleus scattering and its sensitivity to discover new physics beyond the standard model (BSM). Through a combination of increased event rate, lower threshold, and good timing resolution, such a detector would significantly improve on past measurements. We considered tests of several BSM scenarios such as neutrino nonstandard interactions and accelerator-produced dark matter. This detector’s performance was also studied for relevant questions in nuclear physics and neutrino astronomy, namely the weak charge distribution of Cs and I nuclei and detection of neutrinos from a core-collapse supernova. Published by the American Physical Society 2024

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Capability for time-resolved diffraction for material phase in extreme conditions (Q2 FY24 Report)

After a series of development experiments, a new x-ray diffraction diagnostic called FIDDLE (Flexible Imaging Diffraction Diagnostic for Laser Experiments) has been designed, built, and fielded on four shots at NIF. Here we document the initial performance of FIDDLE fielded as the detector in the time-resolved x-ray diffraction experimental platform. Early challenges with EMP have been documented using offline testing in the Target Diagnostics Factory to identify EMP leaks. These techniques were used to guide the application of shielding to weak spots where EM radiation was able to penetrate inside the diagnostic. Application of shielding was found to be effective at reducing EMP leaks, enabling detection of x-ray diffraction on three temporally separated frames during a high pressure (~1Mbar) experiment where lead (Pb) was observed to undergo a phase transition from HCP to BCC.

36 MATERIALS SCIENCE↗

Antihelium-3 sensitivity for the GRAMS experiment

The Gamma-Ray and AntiMatter Survey (GRAMS) is a next-generation balloon/satellite mission utilizing a Liquid Argon Time Projection Chamber (LArTPC) detector to measure both MeV gamma rays and antinuclei produced by dark matter annihilation or decay. The GRAMS can identify antihelium-3 events based on the measurements of X-rays and charged pions from the decay of the exotic atoms, Time of Flight (TOF), energy deposition, and stopping range. This paper shows the antihelium-3 sensitivity estimation using a GEANT4 Monte Carlo simulation. For the proposed long-duration balloon (LDB) flight program (35 days x 3 flights) and future satellite mission (2-year observation/10-year observation), the sensitivities become 1.47 × 10 −7 [m 2 s sr GeV/n] −1 and 1.55 × 10 −9 [m 2 s sr GeV/n] −1 /3.10 x 10 -10 [m 2 s sr GeV/n] −1 , respectively. The results indicate that GRAMS can extensively investigate various dark matter models through the antihelium-3 measurements.

Antihelium-3↗

Calibration and Performance of the ICARUS Detector at Fermilab

ICARUS is the largest Liquid Argon Time Projection Chamber (LArTPC) in operation and serves as the Far Detector of the Short Baseline Neutrino (SBN) program at Fermilab. Precise detector calibration is essential for reliable energy reconstruction and for maximizing the physics reach of the experiment. In this talk, I will describe the energy and timing calibration procedures developed at ICARUS. Thanks to the abundant flux of cosmic ray muons at the surface, the TPC response to ionization charge has been equalized across the detector, removing non-uniformities and in-transparency effects. A novel data-driven procedure has been used to tune the simulation of ionization signals and electronics noise yielding close agreement between Monte Carlo and data with minimal residual bias in reconstructed charge. In addition, the light detection system has been calibrated to sub-nanosecond timing resolution. This precision enables efficient cosmic background rejection and accurate synchronization of neutrino interactions with the time structure of both the Booster Neutrino Beam (BNB) and Neutrinos at the Main Injector (NuMI) beam. Together, these efforts demonstrate the robust performance of the detector and provide critical experience for future large LArTPCs, such as DUNE.

Vicenzi, Matteo [Brookhaven]↗

Readout optimization of multi-amplifier sensing charge-coupled devices for single-quantum measurement

The non-destructive readout capability of the Skipper Charge Coupled Device (CCD) has been demonstrated to reduce the noise limitation of conventional silicon devices to levels that allow single-photon or single-electron counting. The noise reduction is achieved by taking multiple measurements of the charge in each pixel. These multiple measurements come at the cost of extra readout time, which has been a limitation for the broader adoption of this technology in particle physics, quantum imaging, and astronomy applications. This work presents recent results of a novel sensor architecture that uses multiple non-destructive floating-gate amplifiers in series to achieve sub-electron readout noise in a thick, fully-depleted silicon detector to overcome the readout time overhead of the Skipper-CCD. This sensor is called the Multiple-Amplifier Sensing Charge-Coupled Device (MAS-CCD) can perform multiple independent charge measurements with each amplifier, and the measurements from multiple amplifiers can be combined to further reduce the readout noise. We will show results obtained for sensors with 8 and 16 amplifiers per readout stage in new readout operations modes to optimize its readout speed. The noise reduction capability of the new techniques will be demonstrated in terms of its ability to reduce the noise by combining the information from the different amplifiers, and to resolve signals in the order of a single photon per pixel. The first readout operation explored here avoids the extra readout time needed in the MAS-CCD to read a line of the sensor associated with the extra extent of the serial register. The second technique explore the capability of the MAS-CCD device to perform a region of interest readout increasing the number of multiple samples per amplifier in a targeted region of the active area of the device.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Robustness of the smartpixels classifier for different simulated sensor geometries and non-ideal detector conditions

Pixel tracking detectors at upcoming collider experiments will see unprecedented charged-particle densities. Real-time data reduction on the detector will enable higher granularity and faster readout, possibly enabling the use of the pixel detector in high-rate online event selection, such as the ATLAS or CMS first-level trigger systems. This data reduction can be accomplished with a neural network (NN) in the readout chip bonded with the sensor that recognizes and rejects tracks with low transverse momentum (p T ) based on the geometrical shape of the charge deposition (“cluster”). To design viable detectors for deployment, the dependence of the NN as a function of the sensor geometry, external magnetic field, irradiation, and noise must be understood. In this paper, we present first studies of the efficiency and data reduction for planar pixel sensors exploring these parameters. For the CMS HL-LHC sensor geometry, we obtain a signal efficiency of (91.9 ± 0.7)% and a data reduction of (29.7 ± 1.0)%. A smaller sensor pitch in the bending direction improves the p T discrimination, but a larger pitch can be partially compensated with detector thickness. Any accumulated radiation damage also changes the cluster shape, reducing the signal efficiency compared to the baseline by approximately 30–60% in absolute terms, but nearly all of the performance can be recovered through retraining of the network and updating the weights. Finally, the impact of noise was investigated, and retraining the network on noise-injected datasets was found to maintain performance within 6% of the baseline network trained and evaluated on noiseless data. •ASIC-compatible track-momentum classifier is robust in realistic detector conditions.•About 90% signal efficiency and 30% data reduction per layer for CMS HL-LHC geometry.•Single-layer signal efficiency increases for smaller pixel pitch or thicker sensors.•Performance with noise or after radiation damage mostly recovered by retraining.

Shekar, Danush [Illinois U., Chicago] (ORCID:00000↗

The Short-Baseline Near Detector at Fermilab: Input to the European Strategy for Particle Physics 2026 Update

SBND is a 112 ton liquid argon time projection chamber (LArTPC) neutrino detector located 110 meters from the Booster Neutrino Beam (BNB) target at Fermilab. Its main goals include searches for eV-scale sterile neutrinos as part of the Short-Baseline Neutrino (SBN) program, other searches for physics beyond the Standard Model, and precision studies of neutrino-argon interactions. In addition, SBND is providing a platform for LArTPC neutrino detector technology development and is an excellent training ground for the international group of scientists and engineers working towards the upcoming flagship Deep Underground Neutrino Experiment (DUNE). SBND began operation in July 2024, and started collecting stable neutrino beam data in December 2024 with an unprecedented rate of ~7,000 neutrino events per day. During its currently approved operation plans (2024-2027), SBND is expected to accumulate nearly 10 million neutrino interactions. The near detector dataset will be instrumental in testing the sterile neutrino hypothesis with unprecedented sensitivity in SBN and in probing signals of beyond the Standard Model physics. It will also be used to significantly advance our understanding of the physics of neutrino-argon interactions ahead of DUNE. After the planned accelerator restart at Fermilab (2029+), opportunities are being explored to operate SBND in antineutrino mode in order to address the scarcity of antineutrino-argon scattering data, or in a dedicated beam-dump mode to significantly enhance sensitivity to searches for new physics. SBND is an international effort, with approximately 40% of institutions from Europe, contributing to detector construction, commissioning, software development, and data analysis. Continued European involvement and leadership are essential during SBND's operations and analysis phase for both the success of SBND, SBN and its role leading up to DUNE.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗