At least 379 records · Page 21

Groundwater and river water elevations and temperature from 2017 to 2022 across Meander Z in the East River Watershed, Colorado

This dataset includes groundwater and river water elevations and temperature data collected in the East River watershed located in the Upper Colorado River Basin. The data were collected in order to investigate the coupling between hydrology and biogeochemical processes in the floodplain. Data was collected at ten groundwater locations in Meander Z (MZ), located just upstream of the confluence with Brush Creek and two river locations directly adjacent to Meander Z from 2017-2019. From 2019-2022, data was collected at five groundwater locations in Meander Z. Note that location names, not location identifiers (IDs), are used in the related publication Dewey et al. (2022). Both location IDs and names are included in data files. Files in this dataset include the main data files for each location zipped into a single folder (waterlevel_data.zip), an installation methods file describing sensor installation (InstallationMethods.csv), a file containing field metadata including GPS (Global Positioning System) coordinates and ground surface elevations (transducers_locations.csv). This dataset also includes a file-level metadata (flmd.csv) file that lists each file contained in the dataset with associated metadata and a data dictionary (dd.csv) file that contains column/row headers used throughout the files along with a definition, units, and data type. This dataset conforms to the ESS-DIVE hydrological reporting format. 2026-04-27 Update: The river water elevation data files (ER-MZR1.csv and ER-MZR2.csv) were corrected. The data for these two locations were inadvertently swapped in the original published data. This work was supported by the Watershed Function Science Focus Area at Lawrence Berkeley National Laboratory funded by the US Department of Energy, Office of Science, Biological and Environmental Research under Contract No. DE-AC02-05CH11231.

54 ENVIRONMENTAL SCIENCES↗

Coastal typologies and surface and subsurface characteristics of the Alaskan Beaufort Sea Coast

This dataset was generated to classify the Alaskan Beaufort Sea Coast (ABSC) into a set of distinct coastal typologies, to understand the surface and subsurface characteristics and variability of the ABSC, and to quantify relationships between these characteristics and historical rates of shoreline change. This geospatial dataset contains two csv files of points along the ABSC at a 50 m spacing, one for points sheltered by a barrier island and one for points exposed to the open ocean. Each point has a lat/lon location, and we have attributed to each point average values for elevation, historical long-term shoreline change rates, shoreline orientation, landcover, mean annual ground temperature, geomorphic unit, lithology, geology, ecological landscape unit, maximum thaw settlement potential, massive ice content, and segregated ice content. Each point is also assigned to one of 16 coastal typologies, determined by a hierarchical clustering algorithm on the elevation, shoreline change, orientation, and ground temperature data. There are 9 sheltered typologies and 7 exposed typologies, identified by an integer label in the last column of each csv file. The other two csv files contain the integer IDs and classes for the landcover and geomorphology datasets.

54 ENVIRONMENTAL SCIENCES↗

Photovoltaic Inverter Reliability Assessment

As the price of PV modules drops, the price of power electronics become more important. Power electronics now constitute 8%-12% of the total lifetime PV cost. As of 2010, the inverter and associated power conditioning components accounted for $\$0.25$/W, well above the DOE benchmark of $\$0.12$/W by 2020. As efforts to reduce PV module costs yield diminishing returns, the importance of understanding and reducing inverter costs becomes an increasingly critical and cost-effective investment toward achieving the DOE SunShot goals. With this in view, this report showcases and describes an approach to help assess and predict the reliability of photovoltaic (PV) inverters. To predict the reliability, thermal cycling is considered as a prominent stressor in the inverter system. To evaluate the impacts of thermal cycling, a detailed linearized model of the PV inverter is developed along with controllers. This research also develops models and methods to compute the losses of the power electronics switches and other components in a PV inverter. The losses are then used to estimate the junction and heat sink temperature. The model is verified by developing an in-house inverter. Additionally, to assess the scalability of the research, the hardware inverter is placed inside a thermal chamber to verify the losses for different ambient temperatures. After the verification of the model, a reduced-order model of the inverter is implemented to translate the profile of ambient temperature and solar irradiance into the profile of junction temperatures of the switches. The estimated junction temperature data are used to identify inverter reliability indices and predict the useful lifetime of the inverter system. After developing the models to predict the useful lifetime of the system, the impact of reactive power on the overall reliability of the system will be studied. The first chapter involves the motivation behind the research on assessing the reliability of PV inverters. The inverter power stage and controller design of the power converter used in this research is also explained in detail in this chapter. The second chapter presents the various losses of the power converter system and the translation of power loss into temperature increase with thermal modeling. The results of the loss modeling and the thermal modeling are also explained in detail in this chapter. The third chapter involves implementing the reduced-order model to translate the mission profile of ambient temperature and solar irradiance into profile of the junction temperatures of the switches. The final chapter involves identifying reliability indices, which are of interest for this system to predict the remaining useful life of the system, and concludes with the impact of reactive power on the overall reliability of the inverter system.

14 SOLAR ENERGY↗

Data of High-Temperature Dynamic LCM Testing Setup

Data from high temperature dynamic sealing tests for various fracture widths, at various temperatures (degrees F), with 5 wt.% bentonite-based mud containing various material fiber contents, at 100 to 400 psi differential pressure. Data from pressure test and evaluation of the dynamic lost circulation materials (LCM) testing unit to reflect the condition of open and sealed fracture using fracture width of 1000 microns at 120 degrees F. Links to two papers based on the data - "Loss circulation prevention in geothermal drilling by shape memory polymer" which was published in Geothermics 89 (2021) 101943) as well as "Evaluating sealability of blended smart polymer and fiber additive for geothermal drilling with the effect of fracture opening size", published in the Journal of Petroleum Science and Engineering 206 (2021) 108998.

15 GEOTHERMAL ENERGY↗

Time-resolved temperature study in a high-power impulse magnetron sputtering discharge

The gas heating dynamics is studied in a high-power impulse magnetron sputtering discharge operating in Ar-N{sub 2} gas mixtures. The time-resolved rotational temperature analysis based on the spectral transition between the B{sup 2}{Sigma}{sub u}{sup +}-X{sup 2}{Sigma}{sub g}{sup +} energy levels in molecular nitrogen ion (N{sub 2}{sup +} First Negative Band) is undertaken for this purpose. The rotational temperature in the discharge is found to increase linearly during the plasma pulse being roughly independent on the nitrogen content in the examined range. Such a temperature increase is attributed to the bulk gas heating which is the result of collisions with the sputtered species. Two sputtered materials, Ti and W, are examined during the study. In the case of W sputtering, the gas heating is found to be more pronounced than in the Ti case, which is explained by more efficient energy exchange between the sputtered W atoms and the bulk gas atoms during the plasma on-time. The obtained temperature data are compared to the laser-induced fluorescence study of Ar metastable atoms performed recently in the same discharge in our group. The particularities related to gas thermalization as well as to validity of the utilized approach for characterization of the pulsed sputtering discharges are discussed.

74 ATOMIC AND MOLECULAR PHYSICS↗

Phenomenological scattering-rate model for the simulation of the current density and emission power in mid-infrared quantum cascade lasers

A phenomenological scattering-rate model introduced for terahertz quantum cascade lasers (QCLs) [Schrottke et al., Semicond. Sci. Technol. 25, 045025 (2010)] is extended to mid-infrared (MIR) QCLs by including the energy dependence of the intersubband scattering rates for energies higher than the longitudinal optical phonon energy. This energy dependence is obtained from a phenomenological fit of the intersubband scattering rates based on published lifetimes of a number of MIR QCLs. In our approach, the total intersubband scattering rate is written as the product of the exchange integral for the squared moduli of the envelope functions and a phenomenological factor that depends only on the transition energy. Using the model to calculate scattering rates and imposing periodical boundary conditions on the current density, we find a good agreement with low-temperature data for current-voltage, power-current, and energy-photon flux characteristics for a QCL emitting at 5.2 μm.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Peel-and-Stick Sensors Powered by Directed RF Energy

PARC, a Xerox Company, is developing a low-cost system of peel-and-stick wireless sensors that will enable widespread building environment sensor deployment with the potential to deliver up to 30% energy savings. The system is embodied by a set of RF hubs that provide power to automatically located sensor nodes, and relay data wirelessly to the building management system (BMS). The sensor nodes are flexible electronic labels powered by rectified RF energy transmitted by an RF hub and can contain multiple printed and conventional sensors. The system design overcomes limitations in wireless sensors related to power delivery, lifetime, and cost by eliminating batteries and photovoltaic devices. Sensor localization is performed automatically by the inclusion of a programmable multidirectional antenna array in the RF hub. Comparison of signal strengths while the RF beam is swept allows for sensor localization, reducing installation effort and enabling automatic recommissioning of sensors that have been relocated, overcoming a significant challenge in building operations. PARC has already demonstrated wireless power and temperature data transmission up to a distance of 20m with less than one minute between measurements, using power levels well within the FCC regulation limits in the 902-928 MHz ISM band. The sensor’s RF energy harvesting antenna achieves high performance with dimensions below 5cm x 9cm

Lalau-Keraly, Christopher↗

PEEL-AND-STICK SENSORS POWERED BY DIRECTED RF ENERGY

PARC, a Xerox Company, is developing a low-cost system of peel-and-stick wireless sensors that will enable widespread building environment sensor deployment with the potential to deliver up to 30% energy savings. The system is embodied by a set of RF hubs that provide power to automatically located sensor nodes, and relay data wirelessly to the building management system (BMS). The sensor nodes are flexible electronic labels powered by rectified RF energy transmitted by an RF hub and can contain multiple printed and conventional sensors. The system design overcomes limitations in wireless sensors related to power delivery, lifetime, and cost by eliminating batteries and photovoltaic devices. Sensor localization is performed automatically by the inclusion of a programmable multidirectional antenna array in the RF hub. Comparison of signal strengths while the RF beam is swept allows for sensor localization, reducing installation effort and enabling automatic recommissioning of sensors that have been relocated, overcoming a significant challenge in building operations. PARC has already demonstrated wireless power and temperature data transmission up to a distance of 20m with less than one minute between measurements, using power levels well within the FCC regulation limits in the 902-928 MHz ISM band. The sensor’s RF energy harvesting antenna achieves high performance with dimensions below 5cm x 9cm.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

RF Energy Harvesting Peel-and-Stick Sensors

PARC, a Xerox Company, is developing a low-cost system of peel-and-stick wireless sensors that will enable widespread building environment sensor deployment with the potential to deliver up to 30% energy savings. The system is embodied by a set of RF hubs that provide power to the automatically located sensor nodes, and relays data wirelessly to the building management system (BMS). The sensor nodes are flexible electronic labels powered by rectified RF energy transmitted by a RF hub and can contain multiple printed and conventional sensors. The system design overcomes limitations in wireless sensors related to power delivery, lifetime, and cost by eliminating batteries and photovoltaic devices. The sensor localization is performed automatically by the inclusion of a programmable multidirectional antenna array in the RF hub. Comparison of signal strengths when the RF beam is swept allows for sensor localization, further reducing installation effort and enabling automatic recommissioning of sensors that have been relocated, overcoming a significant challenge in building operations. PARC has already demonstrated wireless power and temperature data transmission up to a distance of 20m with a duty cycle less than a minute between measurements, using power levels well within the FCC regulation limits in the 902-928 MHz ISM band. The sensor’s RF energy harvesting antenna dimensions was less than 5cmx9cm, demonstrating the possibility of small form factor for the sensor nodes.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Investigation of core transport changes in DIII-D discharges with off-axis T e profile peaks

Abstract DIII-D discharges that transition to H-mode solely with off-axis electron cyclotron heating (ECH) often exhibit strong off-axis peaking of electron temperature profiles at the heating location. Electron heat transport properties near these off-axis temperature peaks have been studied using modulated ECH. The Fourier analyzed electron temperature data have been used to infer electron thermal diffusivity. Comparisons with numerical solutions of the time-dependent electron thermal equation find that the data are consistent with a narrow region with electron diffusivity χ e an order of magnitude lower than the average value across the plasma, suggesting an electron internal transport barrier (ITB) near the ECH heating location. Detailed profile analysis and equilibrium reconstructions suggest that the formation of these ITBs are correlated with off-axis values of the safety factor q being near 1. Furthermore, the ECH driven H-mode discharges demonstrate more rapid electron heating rate near the ECH deposition location than L-mode discharges with higher auxiliary ECH heating power. Additional modeling attributes this difference to the modification of electron heat transport in the core at the L-H transition, which also sustains the off-axis electron temperature peaks.

Physics↗

STEADY COUNTERFLOW HE II HEAT TRANSFER THROUGH POROUS MEDIA

We present steady state counterflow measurements performed on porous samples saturated in He II. The experiment is composed of a vacuum insulated open channel whose top extremity is closed to a Minco registered heater. The temperature and pressure differences across the plug are measured by two germanium TTR-G Microsensors registered thermometers and a Validyne DP10-20 differential pressure sensor. Applied heat fluxes range up to 0.5 kW/m{sup 2} of sample cross section. Measurements were performed at temperatures ranging from 1.7 to 2.1 K on highly anisotropic samples provided by Composite Technology Development Inc.: circular pellets (3.08 mm thick and 28.58 mm in diameter) of 20 compressed layers of pre-impregnated woven magnet insulation. In the laminar regime, the permeability is estimated from the pressure drop measurements for comparison with room temperature data. In the turbulent regime, the model based on tortuosity developed previously fails to describe the heat transfer behavior of He II in this type of porous medium.

42 ENGINEERING↗

Scaling Individual Tree Transpiration With Thermal Cameras Reveals Interspecies Differences to Drought Vulnerability

Abstract Understanding tree transpiration variability is vital for assessing ecosystem water‐use efficiency and forest health amid climate change, yet most landscape‐level measurements do not differentiate individual trees. Using canopy temperature data from thermal cameras, we estimated the transpiration rates of individual trees at Harvard Forest and Niwot Ridge. PT‐JPL model was used to derive latent heat flux from thermal images at the canopy‐level, showing strong agreement with tower measurements ( R 2 = 0.70–0.96 at Niwot, 0.59–0.78 at Harvard at half‐hourly to monthly scales) and daily RMSE of 33.5 W/m 2 (Niwot) and 52.8 W/m 2 (Harvard). Tree‐level analysis revealed species‐specific responses to drought, with lodgepole pine exhibiting greater tolerance than Engelmann spruce at Niwot and red oak showing heightened resistance than red maple at Harvard. These findings show how ecophysiological differences between species result in varying responses to drought and demonstrate that these responses can be characterized by deriving transpiration from crown temperature measurements.

Javadian, Mostafa↗

Data from: “Bald Cypress (Taxodium distichum) Knees Are Methane Sources Controlled by Geomorphology, Climate, and Hydrologic Extremes”

This dataset is associated with the manuscript “Bald Cypress (Taxodium distichum) Knees Are Methane Sources Controlled by Geomorphology, Climate, and Hydrologic Extremes”. Bald cypress “knees” (aboveground woody roots) have been shown to contribute to wetland methane (CH4) efflux, with large variation within and between studies. To explain this variation, we investigated spatial (i.e., across knee surface, within sites, between sites) and temporal dynamics of CH4 fluxes from knees. Methane fluxes were collected from September 2022 to August 2024 at three locations in western Kentucky, USA, within the Mississippi Alluvial Valley: a main channel (semi-permanently flooded), side channel (seasonally flooded), and reservoir edge (artificially flooded). Knee CH4 fluxes (“Ross_et_al_Knee_Flux_Data.csv”) were measured from multiple heights on knees (20, 40, and 60 cm) of various sizes (knee straight height ranged from 24 to 93 cm) using a LiCOR LI-7810 CH4/CO2/H2O Trace Gas Analyzer. The dataset also includes environmental variables collected with each knee measurement, including water level adjusted for knee-to-knee elevational differences, subsurface and air temperature, and humidity. Soil CH4 fluxes (“Ross_et_al_Soil_Flux_Data.csv”) were also collected adjacent to knees (starting in April 2023) when water levels didn’t overtop soil collars, using a LiCOR Smart Chamber and calculated in SoilFluxPro software. The soil flux dataset includes associated variables collected by the Smart Chamber. Three separate files (“*_Water_Level.csv”) are included for water level and subsurface temperature data collected at each site using HOBO U20L barometric pressure loggers. Each file type (knee flux, soil flux, water level) has an associated data dictionary (“*_dd.csv”). For specifics on methodology used and calculations, see the associated manuscript. The R script includes code used for figures and analyses reported in the manuscript.

54 ENVIRONMENTAL SCIENCES↗

P-ρ-T measurements of H{sub 2}O up to 260 GPa under laser-driven shock loading

Pressure, density, and temperature data for H{sub 2}O were obtained up to 260 GPa by using laser-driven shock compression technique. The shock compression technique combined with the diamond anvil cell was used to assess the equation of state models for the P-ρ-T conditions for both the principal Hugoniot and the off-Hugoniot states. The contrast between the models allowed for a clear assessment of the equation of state models. Our P-ρ-T data totally agree with those of the model based on quantum molecular dynamics calculations. These facts indicate that this model is adopted as the standard for modeling interior structures of Neptune, Uranus, and exoplanets in the liquid phase in the multi-Mbar range.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Trends in extreme temperature over Nigeria from percentile‐based threshold indices

ABSTRACT This study analyses spatial and temporal trends in extreme temperature indices over Nigeria. The percentile indices were calculated from newly homogenized daily minimum and maximum temperature data for the period 1971–2012 for 21 stations in Nigeria. Indices describing the characteristics of hot extremes and cold extremes are calculated with the RClimDex software. The annual and seasonal trends in these indices are obtained using the ordinary least square fit and the statistical significance tested using the R‐based modified Mann–Kendall test. We examine characteristics of these indices for the entire country and separately for the three geographical zones in Nigeria: Guinea, Savanna, and Sahel. The spatial and temporal patterns of trends in the indices indicate that Nigeria has experienced statistically significant increase in the frequency of hot extreme and decrease in cold extreme events. Although majority of the stations have significant trends in warm days and warm nights, the annual trend is greatest in warm nights. In addition, the rate of warming in minimum temperature (‘warm nights’) is stronger in June, July, August ( JJA ) and September, October, November ( SON ) compare with December, January, February ( DJF ) and March, April, May ( MAM ). As for the trends in cold days and cold nights, the trends in cold nights are larger than for cold days at both the annual and seasonal scales. The regional analysis indicates that trends in warm nights and cold nights are most pronounced in Guinea and Sahel regions.

Abatan, Abayomi A.↗

Optimal Spectral Resolution for Infrared Studies of Solids and Liquids

Due to a legacy originating in the limited capability of early computers, the spectroscopic resolution used in Fourier transform infrared spectroscopy and other systems has largely been implemented using only powers of two for more than 50 years. In this study, we investigate debunking the spectroscopic lore of, e.g., using only 2, 4, 8, or 16 cm −1 resolution and determine the optimal resolution in terms of both (i) a desired signal-to-noise ratio and (ii) efficient use of acquisition time. The study is facilitated by the availability of solids and liquids reference spectral data recorded at 2.0 cm −1 resolution and is based on an examination in the 4000–400 cm −1 range of 61 liquids and 70 solids spectra, with a total analysis of 4237 peaks, each of which was also examined for being singlet/multiplet in nature. Of the 1765 liquid bands examined, only 27 had widths <5 cm −1 . Of the 2472 solid bands examined, only 39 peaks have widths <5 cm −1 . For both the liquid and solid bands, a skewed distribution of peak widths was observed: For liquids, the mean peak width was 24.7 cm −1 but the median peak width was 13.7 cm −1 , and, similarly, for solids, the mean peak width was 22.2 cm −1 but the median peak width was 11.2 cm −1 . While recognizing other studies may differ in scope and limiting the analysis to only room temperature data, we have found that a resolution to resolve 95% of all bands is 5.7 cm −1 for liquids and 5.3 cm −1 for solids; such a resolution would capture the native linewidth (not accounting for instrumental broadening) for 95% of all the solids and liquid bands, respectively. After decades of measuring liquids and solids at 4, 8, or 16 cm −1 resolution, we suggest that, when accounting only for intrinsic linewidths, an optimized resolution of 6.0 cm −1 will capture 91% of all condensed-phase bands, i.e., broadening of only 9% of the narrowest of bands, but yielding a large gain in signal-to-noise with minimal loss of specificity.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Cubic boron nitride as a primary calibrant for a high temperature pressure scale

We present results establishing a new high pressure scale at high temperature based on the thermal equation of state and elastic properties of cubic boron nitride (cBN). This scale is derived from simultaneous measurements of density and sound velocities at high pressure and temperature independent of any previous pressure scale. The present results obtained at room temperature to 27 GPa suggest the validity of the current ruby scale (within {+-}4% at 100 GPa). At high temperature, data obtained at 16 GPa to 723 K are in fair agreement with the thermal equation of state of cBN reported in our previous work. We have also shown that cBN can serve as a convenient pressure gauge in X-ray and optical studies using the laser heated diamond anvil cell.

36 MATERIALS SCIENCE↗

Riverscape heterogeneity in estimated Chinook Salmon emergence phenology and implications for size and growth

Abstract Many salmonid‐bearing rivers exhibit thermal and hydrologic heterogeneity at multiple spatial and temporal scales, but how this translates into spatiotemporal patterns of fry emergence is poorly understood. Understanding this variability is important because emergence timing determines the biophysical conditions fish first experience (e.g., temperature, flow, and food supply), thereby influencing growth opportunities and survival during this critical life stage. We predicted spring Chinook Salmon ( Oncorhynchus tshawytscha ) emergence phenology across four northeastern Oregon subbasins over 5–9 years using empirical spawning and temperature data. We then related interannual emergence timing estimates to juvenile salmon size and growth rates at consistent sampling locations. There were clear longitudinal patterns of predicted emergence timing in each subbasin: The shape of these patterns was consistent among years, but not among subbasins. In two subbasins, emergence occurred progressively later with distance upstream, whereas in the other two subbasins emergence was earliest at upstream sites. Within each year, median emergence dates among sites within each subbasin ranged between 44 and 58 days. This spatial variation was comparable to interannual variation, with median emergence dates for a given location in each subbasin ranging between 47 and 74 days among years. Contrary to our expectations, juvenile salmon were not larger in years with earlier emergence, owing to slower estimated spring and summer growth rates compared to years with later emergence. Despite large interannual variation in estimated emergence dates, these results suggest that other factors (e.g., stream flow, temperature, and density‐dependence) were more important than growth duration in determining juvenile salmon growth rates and size among years. We demonstrated considerable spatial and interannual variation in emergence phenology within these subbasins. Understanding how this variation translates to spatiotemporal patterns of juvenile salmon habitat use, growth, and survival has important implications for guiding restoration efforts and understanding how climate change may impact these populations.

Kaylor, Matthew J.↗