Imaging and sensing based on muon tomography
Techniques, apparatus and systems for detecting particles such as muons for imaging applications. Subtraction techniques are described to enhance the processing of the muon tomography data.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Techniques, apparatus and systems for detecting particles such as muons for imaging applications. Subtraction techniques are described to enhance the processing of the muon tomography data.
Purpose: High-quality radiation therapy using highly conformal dose distributions and image-guided techniques requires optimum machine delivery performance. In this work, a monitoring system for multileaf collimator (MLC) performance, integrating semiautomated MLC quality control (QC) tests and statistical process control tools, was developed. The MLC performance monitoring system was used for almost a year on two commercially available MLC models. Control charts were used to establish MLC performance and assess test frequency required to achieve a given level of performance. MLC-related interlocks and servicing events were recorded during the monitoring period and were investigated as indicators of MLC performance variations. Methods: The QC test developed as part of the MLC performance monitoring system uses 2D megavoltage images (acquired using an electronic portal imaging device) of 23 fields to determine the location of the leaves with respect to the radiation isocenter. The precision of the MLC performance monitoring QC test and the MLC itself was assessed by detecting the MLC leaf positions on 127 megavoltage images of a static field. After initial calibration, the MLC performance monitoring QC test was performed 3–4 times/week over a period of 10–11 months to monitor positional accuracy of individual leaves for two different MLC models. Analysis of test results was performed using individuals control charts per leaf with control limits computed based on the measurements as well as two sets of specifications of ±0.5 and ±1 mm. Out-of-specification and out-of-control leaves were automatically flagged by the monitoring system and reviewed monthly by physicists. MLC-related interlocks reported by the linear accelerator and servicing events were recorded to help identify potential causes of nonrandom MLC leaf positioning variations. Results: The precision of the MLC performance monitoring QC test and the MLC itself was within ±0.22 mm for most MLC leaves and the majority of the apparent leaf motion was attributed to beam spot displacements between irradiations. The MLC QC test was performed 193 and 162 times over the monitoring period for the studied units and recalibration had to be repeated up to three times on one of these units. For both units, rate of MLC interlocks was moderately associated with MLC servicing events. The strongest association with the MLC performance was observed between the MLC servicing events and the total number of out-of-control leaves. The average elapsed time for which the number of out-of-specification or out-of-control leaves was within a given performance threshold was computed and used to assess adequacy of MLC test frequency. Conclusions: A MLC performance monitoring system has been developed and implemented to acquire high-quality QC data at high frequency. This is enabled by the relatively short acquisition time for the images and automatic image analysis. The monitoring system was also used to record and track the rate of MLC-related interlocks and servicing events. MLC performances for two commercially available MLC models have been assessed and the results support monthly test frequency for widely accepted ±1 mm specifications. Higher QC test frequency is however required to maintain tighter specification and in-control behavior.
The objective of the Fourth Technical Meeting on Fusion Data Processing, Validation and Analysis was to provide a platform during which a set of topics relevant to fusion data processing, validation and analysis are discussed with the view of extrapolating needs to next step fusion devices such as ITER. The validation and analysis of experimental data obtained from diagnostics used to characterize fusion plasmas are crucial for a knowledge-based understanding of the physical processes governing the dynamics of these plasmas. This paper presents the recent progress and achievements in the domain of plasma diagnostics and synthetic diagnostics data analysis (including image processing, regression analysis, inverse problems, deep learning, machine learning, big data and physics-based models for control) reported at the meeting. The progress in these areas highlight trends observed in current major fusion confinement devices. A special focus is dedicated on data analysis requirements for ITER and DEMO with a particular attention paid to artificial intelligence for automatization and improving reliability of control processes.
Soft x-ray zone plate microscopy has proven to be a valuable imaging technique for nanoscale studies. It complements nano-analytic techniques such as electron and scanning probe microscopies. One of its key features is high spatial resolution. We developed an overlay nanofabrication process which allows zone plates of sub-20 nm zone widths to be fabricated. Zone plates of 15 nm outer zones were successfully realized using this process, and sub-15 nm resolution was achieved with these zone plates. We extend the overlay process to fabricating zone plates of 12 nm outer zones, which is expected to achieve 10 nm resolution. In addition, we have identified a pathway to realizing sub-10 nm resolution, high efficiency zone plates with tilted zones using the overlay process.
Purpose: To describe the feasibility of lymphangiography and the visibility of the lymphatic system using post-lymphangiographic multidetector CT (MDCT) for preclinical lymphatic interventions in a rabbit model. Materials and Methods: Lymphangiography via the popliteal lymph node or vessel after surgical exposure was performed, using six healthy female Japanese White rabbits. Lipiodol was manually injected for lymphangiography. Post-lymphangiographic MDCT examinations were performed in all rabbits. The dataset images were subjected to image processing analysis utilizing the three-dimensional maximum intensity projection technique. Three reviewers evaluated the degree of depiction of the lymphatic system using a four-point visual score (1, poor; 2, fair; 3, good; 4, excellent). The distance between the body surface and cisterna chyli was measured on post-lymphangiographic MDCT axial image. Results: Lymphangiography was successfully performed in all rabbits. The popliteal lymph node was detectable in 90%. The visualization of lymphatic system via the popliteal node was achieved in 89%. Mean visual scores of > 3.0 were realized by the right femoral lymphatic vessel, left femoral lymphatic vessel, left iliac lymphatic vessel, left lumbar lymphatic trunks and cisterna chyli, whereas mean visual scores of < 3.0 were yielded by the right iliac lymphatic vessel, right lumbar lymphatic trunks and thoracic duct. The distance between the body surface and cisterna chyli on post-lymphangiographic MDCT axial images was 4.33 ± 0.14 cm. Conclusion: Lymphangiography is feasible, and the visibility of the lymphatic system on post-lymphangiographic MDCT in a rabbit model provides enough information for interventional radiologists to perform preclinical lymphatic interventions.
Tomographic imaging of time-evolving samples is a challenging yet important task for various research fields. At the nanoscale, current approaches face limitations of measurement speed or resolution due to lengthy acquisitions. We developed a dynamic nanotomography technique based on sparse dynamic imaging and 4D tomography modeling. We demonstrated the technique, using ptychographic x-ray computed tomography as its imaging modality, on resolving the in situ hydration process of polymer electrolyte fuel cell (PEFC) catalyst. The technique provides a 40-time increase in temporal resolution compared to conventional approaches, yielding 28 nm half-period spatial and 12 min temporal resolution. The results allow a quantitative characterization of the water intake process inside PEFC catalysts with nanoscale resolution, which is crucial for understanding their electrochemical mechanisms and optimizing their performance. Our technique enables high-speed operando nanotomography studies and paves the way for wider application of dynamic tomography at the nanoscale.
Characterisation results are presented for ohmic contacts to passivated crystalline silicon, formed using the point-contacting by localised dielectric breakdown technique. Self aligned contact is made between the metal and heavily doped surface regions through an intrinsic a-Si:H passivation layer. Local doping is provided by a laser using a standard technique identical to that for selective emitter formation. Our results for gate metals of Au, Al, and Ti show that the technique does not rely on reactivity between the dielectric and the metal, excluding metal induced crystallisation from the contacting process. Diffusion of the gate metal into the dielectric is observed in transmission electron microscope images suggesting high temperatures are present locally during the breakdown process. The technique is equally applicable to contacting of n and p-type silicon, making it a potential alternative for ohmic contacting to silicon to passivated rear surfaces.
Friction consolidation (FC) is a solid phase processing approach where discrete material forms such as powders, chips, nuggets, etc. are densified via shear deformation. The precursors are placed in a billet container and brought in contact with a rotating tool that applying the desirable amount of normal force. Under the combined action of the rotation and normal pressure, the discrete precursor is consolidated through porosity reduction and shear deformation. FC is increasingly being studied as an attractive approach to manufacturing fully dense parts from powder forms owing to its ability to mix, alloy and consolidate difficult-to-process precursors in minimal number of process steps. Material consolidation and deformation in shear consolidation processes have been studied extensively previously for different material combinations previously. However, despite the extensive research in this area, understanding of the mechanistic processes in pore consolidation, deformation-induced mixing and material solubility during FC is still evolving. Material development using solid phase processing approaches such as FC is often performed based on research experience/education, which can be biased. Conventional analysis and simulation tools in this area tend to be successful only when material thermodynamic pathways and microstructural evolution sequences resulting from processing are clearly defined or known. They are not as effective for emerging advanced manufacturing technologies where material evolution pathways are not well established. The ability to predict optimal process parameters based on material chemistry and bulk properties is essential to accelerate materials design and processing, as are an understanding of the relevant structure-processing-property relationships. These structure-processing-property-performance relationships are at the core of materials science research. Microstructure characterization provides the link to these four core areas, often through visualizing material microstructure using imaging techniques. However, linking microstructure image data (i.e., micrographs) to variables of interest (e.g., processing parameters, material chemistry) in a reproducible, generalizable, and quantitative manner is a significant challenge. Typically, quantitatively linking image data to processing history relies on significant domain knowledge and manual or subject matter expert (SME)-heuristic based image analysis. Such an approach to image analysis has the potential to be biased, inefficient, and difficult to replicate.
We describe an algorithm for identifying point-source transients and moving objects on reference-subtracted optical images containing artifacts of processing and instrumentation. The algorithm makes use of the supervised machine learning technique known as Random Forest. We present results from its use in the Dark Energy Survey Supernova program (DES-SN), where it was trained using a sample of 898,963 signal and background events generated by the transient detection pipeline. After reprocessing the data collected during the first DES-SN observing season (2013 September through 2014 February) using the algorithm, the number of transient candidates eligible for human scanning decreased by a factor of 13.4, while only 1.0% of the artificial Type Ia supernovae (SNe) injected into search images to monitor survey efficiency were lost, most of which were very faint events. Here we characterize the algorithm’s performance in detail, and we discuss how it can inform pipeline design decisions for future time-domain imaging surveys, such as the Large Synoptic Survey Telescope and the Zwicky Transient Facility. An implementation of the algorithm and the training data used in this paper are available at at http://portal.nersc.gov/project/dessn/autoscan.
We have combined two seafloor mapping techniques to efficiently map benthic habitat conditions. Multibeam echosounder (MBES) surveys provide detailed bathymetry and backscatter mosaics. Sediment profile and plan view imaging (SPI/PV) rapidly provides dense ground truth data on seabed physical and biological features. A key innovation of this project has been the development of a computer-assisted image processing system that standardizes the SPI data generation process. A unique combination of machine- and deep-learning techniques for grain-size classification, sediment–water interface delineation, and object detection (e.g., infauna and feeding voids) is described. An automated SPI image analysis system provides a standardized and cost-effective approach for image processing. Combining MBES with SPI/PV camera technology provides a first tier approach to rapidly documenting seabed physical and biological conditions in high resolution at MHK sites. When coupled with computer automated data extraction from the imagery, this approach provides a standardized and cost-effective method to establish and monitor benthic habitat conditions over time.
The eXtreme Deep Field (XDF) combines data from 10 years of observations with the Hubble Space Telescope Advanced Camera for Surveys (ACS) and the Wide-Field Camera 3 Infra-Red (WFC3/IR) into the deepest image of the sky ever in the optical/near-IR. Since the initial observations of the Hubble Ultra-Deep Field (HUDF) in 2003, numerous surveys and programs, including supernovae follow-up, HUDF09, CANDELS, and HUDF12, have contributed additional imaging data across this region. However, these images have never been combined and made available as one complete ultra-deep image dataset. We combine them now with the XDF program. Our new and improved processing techniques provide higher quality reductions of the total dataset. All WFC3/IR and optical ACS data sets have been fully combined and accurately matched, resulting in the deepest imaging ever taken at these wavelengths, ranging from 29.1 to 30.3 AB mag (5σ in a 0.''35 diameter aperture) in 9 filters. The combined image therefore reaches to 31.2 AB mag 5σ (32.9 at 1σ) for a flat f {sub ν} source. The gains in the optical for the four filters done in the original ACS HUDF correspond to a typical improvement of 0.15 mag, with gains of 0.25 mag in the deepest areas. Such gains are equivalent to adding ∼130 to ∼240 orbits of ACS data to the HUDF. Improved processing alone results in a typical gain of ∼0.1 mag. Our 5σ (optical+near-IR) SExtractor catalogs reveal about 14,140 sources in the full field and about 7121 galaxies in the deepest part of the XDF.
Recent years have seen the emergence of CT image reconstruction techniques that exploit physical models of the imaging system, photon statistics, and even the patient to achieve improved 3D image quality and/or reduction of radiation dose. With numerous advantages in comparison to conventional 3D filtered backprojection, such techniques bring a variety of challenges as well, including: a demanding computational load associated with sophisticated forward models and iterative optimization methods; nonlinearity and nonstationarity in image quality characteristics; a complex dependency on multiple free parameters; and the need to understand how best to incorporate prior information (including patient-specific prior images) within the reconstruction process. The advantages, however, are even greater – for example: improved image quality; reduced dose; robustness to noise and artifacts; task-specific reconstruction protocols; suitability to novel CT imaging platforms and noncircular orbits; and incorporation of known characteristics of the imager and patient that are conventionally discarded. This symposium features experts in 3D image reconstruction, image quality assessment, and the translation of such methods to emerging clinical applications. Dr. Chen will address novel methods for the incorporation of prior information in 3D and 4D CT reconstruction techniques. Dr. Pan will show recent advances in optimization-based reconstruction that enable potential reduction of dose and sampling requirements. Dr. Stayman will describe a “task-based imaging” approach that leverages models of the imaging system and patient in combination with a specification of the imaging task to optimize both the acquisition and reconstruction process. Dr. Samei will describe the development of methods for image quality assessment in such nonlinear reconstruction techniques and the use of these methods to characterize and optimize image quality and dose in a spectrum of clinical applications. Learning Objectives: Learn the general methodologies associated with model-based 3D image reconstruction. Learn the potential advantages in image quality and dose associated with model-based image reconstruction. Learn the challenges associated with computational load and image quality assessment for such reconstruction methods. Learn how imaging task can be incorporated as a means to drive optimal image acquisition and reconstruction techniques. Learn how model-based reconstruction methods can incorporate prior information to improve image quality, ease sampling requirements, and reduce dose.
Tissues are composed of diverse cell subpopulations each with distinct metabolic characteristics that influence overall behavior. Unfortunately, traditional histopathology imaging techniques are ‘blind’ to the spatially ordered metabolic dynamics within tissue. While mass spectrometry imaging enables spatial mapping of molecular composition, resulting images are only a static snapshot in time of molecules involved in highly dynamic processes; kinetic information of flux through metabolic pathways is lacking. To address this limitation, we developed kinetic mass spectrometry imaging (kMSI), a novel technique integrating soft desorption/ionization mass spectrometry with clinically accepted in vivo metabolic labeling of tissue with deuterium to generate images of kinetic information of biological processes. Applied to a tumor, kMSI revealed heterogeneous spatial distributions of newly synthesized versus pre-existing lipids, with altered lipid synthesis patterns distinguishing region-specific intratumor subpopulations. Images also enabled identification and correlation of metabolic activity of specific lipids found in tumor regions of varying grade.
Electrical impedance tomography (EIT) is one of the process tomography techniques to provide an on-line non-invasive imaging for multiphase flow measurement. With EIT measurements, the images of impedance real part, impedance imaginary part, phase angle, and magnitude can be obtained. However, most of the applications of EIT in the process industries rely on the conductivity difference between two phases in fluids to obtain the concentration profiles. It is not common to use the imaginary part or phase angle due to the dominant change in conductivity or complication in the use of other impedance information. In a solid-liquid two phases system involving nano- or submicro-particles, characterisation of particles (e.g. particle size and concentration) have to rely on the measurement of impedance phase angle or imaginary part. Particles in a solution usually have an electrical double layer associated with their surfaces and can form an induced electrical dipole moment due to the polarization of the electrical double layer under the influence of an alternating electric field. Similar to EIT, electrical impedance spectroscopy (EIS) measurement can record the electrical impedance data, including impedance real part, imaginary part and phase angle (θ), which are caused by the polarization of the electrical double layer. These impedance data are related to the particle characteristics e.g. particle size, particle and ionic concentrations in the aqueous medium, therefore EIS method provides a capability for characterising the particles in suspensions. Electrical impedance tomography based on EIS measurement or namely, electrical impedance tomography spectroscopy (EITS) could image the spatial distribution of particle characteristics. In this paper, a new method, including test set-up and data analysis, for characterisation of particles in suspensions are developed through the experimental approach. The experimental results on tomographic imaging of colloidal particles based on EIS measurement using a sensor of 8 electrodes are reported. Results have demonstrated the potential as well as revealed the challenge in the use of EIS and EITS for characterisation of particle in suspension.
Quantitative phase contrast microscopy reveals thickness or height information of a biological or technical micro-object under investigation. The information obtained from this process provides a means to study their dynamics. Digital holographic (DH) microscopy is one of the most used, state of the art single-shot quantitative techniques for three dimensional imaging of living cells. Conventional off axis DH microscopy directly provides phase contrast images of the objects. However, this process requires two separate beams and their ratio adjustment for high contrast interference fringes. Also the use of two separate beams may make the system more vulnerable to vibrations. Single beam techniques can overcome these hurdles while remaining compact as well. Here, we describe the development of a single beam DH microscope providing whole field imaging of micro-objects. A hologram of the magnified object projected on to a diffuser co-located with a pinhole is recorded with the use of a commercially available diode laser and an arrayed sensor. A Fourier transform of the recorded hologram directly yields the complex amplitude at the image plane. The method proposed was investigated using various phase objects. It was also used to image the dynamics of human red blood cells in which sub-micrometer level thickness variation were measurable.
Using operando Bragg coherent x-ray diffraction imaging, we visualised three-dimensionally a single twinned-gold nanocrystal during the CO oxidation reaction. We describe the defect dynamics process occurring under operating conditions and indicate the correlation between the nucleation of highly strained regions at the surface of the nanocrystal and its catalytic activity. Understanding the twinning deformation mechanism sheds light on the creation of active sites, and could well contribute to the understanding of the catalytic behaviour of other catalysts. Furthermore, with the start-up of 4th generation synchrotron sources, we anticipate that coherent hard x-ray diffraction imaging techniques will play a major role in imaging in situ chemical processes.
Laser-induced electron diffraction is an evolving tabletop method that aims to image ultrafast structural changes in gas-phase polyatomic molecules with sub-Ångstro¨m spatial and femtosecond temporal resolutions. Here we demonstrate the retrieval of multiple bond lengths from a polyatomic molecule by simultaneously measuring the C–C and C–H bond lengths in aligned acetylene. Our approach takes the method beyond the hitherto achieved imaging of simple diatomic molecules and is based on the combination of a 160 kHz mid-infrared few-cycle laser source with full three-dimensional electron–ion coincidence detection. Our technique provides an accessible and robust route towards imaging ultrafast processes in complex gas-phase molecules with atto- to femto-second temporal resolution.
Purpose: The objective of this study is to propose an alternative QA technique that analyzes imaging quality(IQ) in CBCT-QA processing. Methods: A catphan phantom was used to take CT imaging data set that were imported into a treatment planning system - Eclipse. The image quality was analyzed in terms of in-slice geometry resolution, Hounsfield numbers(HU) accuracy, mean-slice thickness, edge-to-center uniformity, low contrast resolution, and high contrast spatial resolution in Eclipse workstation. The CBCT-QA was also analyzed by OBI-workstation and a commercial software. Comparison was made to evaluation feasibility in a TPS environment. Results: The analysis of IQ was conducted in Eclipse v10.0 TPS. In-slice geometric resolution was measured between 2-rods in section CTP404 and repeated for all 4 rods with the difference between expected and measured values less than +/−0.1 cm. For HU, the difference between expected and measured values in HU was found much less than +/−40. Mean slice thickness measured by a distance on the wire proportional to scanner increment multiplying by a factor of 0.42. After repeating measurements to 4 wires, the average difference between expected and measured values was less +/−0.124 mm in slice thickness. HU uniformity was measured in section CTP486 with the tolerance less than +/−40 HU. Low contrast resolution in section CTP515 and high contrast resolution in section CTP528 were found to be 7 disks in diameter of 4 mm and 6 lp/cm, respectively. Eclipse TPS results indicated a good agreement to those obtained in OBI workstation and ImagePro software for major parameters. Conclusion: An analysis of IQ was proposed as an alternative CBCT QA processing. Based upon measured data assessment, proposed method was accurate and consistent to IQ evaluation and TG142 guideline. The approach was to utilize TPS resource, which can be valuable to re-planning, verification, and delivery in adaptive therapy.