Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Carbon balance in bioregenerative life support systems: some effects of system closure, waste management, and crop harvest index

In Advanced Life Support (ALS) systems with bioregenerative components, plant photosynthesis would be used to produce O2 and food, while removing CO2. Much of the plant biomass would be inedible and hence must be considered in waste management. This waste could be oxidized (e.g., incinerated or aerobically digested) to resupply CO2 to the plants, but this would not be needed unless the system were highly closed with regard to food. For example, in a partially closed system where some of the food is grown and some is imported, CO2 from oxidized waste when combined with crew and microbial respiration could exceed the CO2 removal capability of the plants. Moreover, it would consume some O2 produced from photosynthesis that could have been used by the crew. For partially closed systems it would be more appropriate to store or find other uses for the inedible biomass and excess carbon, such as generating soils or growing woody plants (e.g., dwarf fruit trees). Regardless of system closure, high harvest crops (i.e., crops with a high edible to total biomass ratio) would increase food production per unit area and O2 yields for systems where waste biomass is oxidized to recycle CO2. Such interlinking effects between the plants and waste treatment strategies point out the importance of oxidizing only that amount of waste needed to optimize system performance. Published by Elsevier Science Ltd on behalf of COSPAR.

NASA Discipline Life Support Systems↗

Optimal Strategies for Hybrid Battery‐Storage Systems Design

As stationary hybrid energy‐storage systems (HESS) for power systems applications have recently drawn interest due to their enhanced performance and decreasing cost, developing systematic approaches for HESS design while considering controls is gaining traction. Herein, a method is presented to optimally design hybrid battery storage by proposing a mathematical modeling framework, formulated as a mixed integer linear programming model. The optimization is capable of handling multiple subsystems of batteries, considering their economic and technological performance. Decisions involve sizing of the batteries, optimal temporal and strategic dispatch to end uses, and energy sources for charging each battery. The applicability of the model is tested on four case studies for three battery chemistries representing distinct objectives: high‐power, high‐energy, and second life. Compared to traditionally designed battery storage with a homogeneous battery, optimally designed hybrid systems can save 12%–26% of system costs, depending on the nature of the dispatch profile. Findings point to design preference toward the second life battery supplemented with some high‐power or high‐energy battery capacity, or both. With the utilized electricity price structure, customers can experience approximately 10%–35% reduction in their bills.

Koleva, Mariya↗

System design and analysis of thermal power dispatch systems for boiling water reactors

Nuclear power plants are crucial to meeting net zero emission goals and achieving energy sustainability. Integrating these plants with clean energy technologies such as high-temperature steam electrolysis (HTSE) may improve the efficiency and economic competitiveness of these plants. Here, the current study investigates the design and operation of a thermal power dispatch (TPD) system for coupling boiling water reactors (BWRs) to HTSE plants. The TPD system extracts a portion of the steam from the reactor’s main steam line and transfers its thermal energy to an HTSE plant through a power transport loop. A TPD system for 5 % steam extraction has been designed and the system performance during steady and transient operations has been analyzed. The TPD system dispatched a total of 197 MW thermal energy to the HTSE plant under nominal design conditions. Saturated steam at 7.17 MPa from the BWR plant was condensed and subcooled to a temperature of 168 °C, while a mass flow rate of 91.1 kg/s of superheated steam was dispatched to the HTSE plant. Furthermore, the system performance during transient operation showed a continuous transition from the initial hot standby mode to the nominal power dispatch level. The transient simulation results emphasized the importance of investigating component level performance for the TPD system design. The current results will guide future works on the development of integrated energy systems for hydrogen production or process heat applications.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Coupling fast fluid dynamics and multizone airflow models in Modelica Buildings library to simulate the dynamics of HVAC systems

Multizone models are widely used in building airflow and energy performance simulations due to their fast computing speed. However, multizone models assume that the air in a room is well mixed, consequently limiting their application. In specific rooms where this assumption fails, the use of computational fluid dynamics (CFD) models may be an alternative option. Previous research has mainly focused on coupling CFD models and multizone models to study airflow in large spaces. While significant, most of these analyses did not consider the coupled simulation of the building airflow with the building’s Heating, Ventilation, and Air-Conditioning (HVAC) systems. This paper tries to fill the gap by integrating the models for HVAC systems with coupled multizone and CFD simulations for airflows, using the Modelica simulation platform. To improve the computational efficiency, we incorporated a simplified CFD model named fast fluid dynamics (FFD). We first introduce the data synchronization strategy and implementation in Modelica. Then, we verify the implementation using two case studies involving an isothermal and a non-isothermal flow by comparing model simulations to experiment data. Afterward, we study another three cases that are deemed more realistic. Furthermore, this is done by attaching a variable air volume (VAV) terminal box and a VAV system to previous flows to assess the capability of the models in studying the dynamic control of HVAC systems. Finally, we discuss further research needs on the coupled simulation using the models.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Data-Driven Distributed Algorithms for Estimating Eigenvalues and Eigenvectors of Interconnected Dynamical Systems

Here, the paper presents data-driven algorithms to estimate in a distributed manner the eigenvalues, right and left eigenvectors of an unknown linear (or linearized) interconnected dynamic system. In particular, the proposed algorithms do not require the identification of the system model in advance before performing the estimation. As a first step, we consider interconnected dynamical system with distinct eigenvalues. The proposed strategy first estimates the eigenvalues using the well-known Prony method. The right and left eigenvectors are then estimated by solving distributively a set of linear equations. One important feature of the proposed algorithms is that the topology of communication network used to perform the distributed estimation can be chosen arbitrarily, given that it is connected, and is also independent of the structure or sparsity of the system (state) matrix. The proposed distributed algorithms are demonstrated via a numerical example.

97 MATHEMATICS AND COMPUTING↗

Solubility of U(VI) in chloride solutions. III. The stable oxides/hydroxides in MgCl 2 systems: Pitzer activity model for the system UO 2 2+ –Na + –K + –Mg 2+ –H + –OH – –Cl – –H 2 O(l)

Here we have developed new chemical, thermodynamic and activity models for the system UO 2 2+ –Na + –K + –Mg 2+ –H + –OH – –Cl – –H 2 O(l) within the Pitzer approach. The new thermodynamic model is based on previously reported data treated within the SIT approach for NaCl and KCl systems, as well as on new experimental data determined in this work for the MgCl 2 system. The solubility of uranium(VI) was studied in 0.01–5.15 mol·kg w –1 MgCl 2 solutions at pH m = 4.1–9.7 (with pH m = –log [H + ]). Experiments were performed under Ar atmosphere at T = (22 ± 2) °C. In all investigated systems, the solubility of U(VI) is controlled by metaschoepite, UO 3 ·2H 2 O(cr). In contrast to previously investigated NaCl and KCl systems, no ternary Mg–U(VI)–OH(s) solid phases formed in alkaline MgCl 2 solutions within the timeframe of this study (≤ 200 days). A very significant increase in the solubility (up to 3 log 10 -units) is observed in acidic to near-neutral pH m conditions when increasing MgCl 2 concentration from 0.01 to 5.15 mol·kg w –1 , which reflects the strong ion interaction processes taking place in concentrated MgCl 2 brines. The solubility of UO 3 ·2H 2 O(cr) in the investigated NaCl, KCl and MgCl 2 solutions is well described with the solubility and hydrolysis constants recommended by Altmaier et al., (2017) and NEA–TDB, and a Pitzer activity model derived in the present work. The latter model considers experimental data reported in the present study and available in the literature for NaCl, KCl and MgCl 2 systems (solubility, potentiometric and spectroscopic data), in combination with well-stablished estimation methods and correlations with SIT coefficients. Finally, chemical, thermodynamic and Pitzer activity models provided in this work for the system UO 2 2+ –Na + –K + –Mg 2+ –H + –OH – –Cl – –H 2 O(l) accurately describe all evaluated datasets, and represent an adequate tool for the calculation of U(VI) solubility and aqueous speciation in a variety of geochemical conditions including concentrated brine systems of relevance in salt-based repositories for nuclear waste disposal.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Distribution system versus bulk power system: identifying the source of electric service interruptions in the US

This study reports on the results from efforts by the Institute of Electric and Electronics Engineers (IEEE) Distribution Reliability Working Group (DRWG) and the U.S. Energy Information Administration (EIA) to improve the usefulness of reliability metrics by developing and then applying consistent, yet distinct measures of the continuity of supply based on the portion of the electric power system from which power interruptions originate: the lower voltage distribution system versus the high‐voltage bulk power system. The modified metrics better support reliability planning in the US because they separately measure the effectiveness of actions to improve reliability made by the two distinct groups of firms (and their regulators or oversight bodies) that are responsible for planning and operating each portion of the US electric power system. The authors then present for the first time quantitative information on the reliability of each portion of the US electric power system. When reliability is measured using the system average interruption duration index and the system average interruption frequency index, they find that the distribution system accounts for at least 94 and 92%, respectively, of all interruptions. They also find that these relationships have been stable over the recent past.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Conservation Voltage Reduction (CVR) via Two-Timescale Control in Unbalanced Power Distribution Systems

Voltage control devices are employed in power distribution systems to reduce the power consumption by operating the system closer to the lower acceptable voltage limits; this technique is called conservation voltage reduction (CVR). The different modes of operation for system’s legacy devices (with binary control) and new devices (e.g. smart inverters with continuous control) coupled with variable photovoltaic (PV) generation results in voltage fluctuations which makes it challenging to achieve CVR objective. This paper presents a two-timescale control of feeder’s voltage control devices to achieve CVR that includes (1)a centralized controller operating in a slower time-scale to coordinate voltage control devices across the feeder and (2) local controllers operating in a faster timescale to mitigate voltage fluctuations due to PV variability. The centralized controller utilizes a three-phase optimal power flow model to obtain the decision variables for both legacy devices and smart inverters. The local controllers operate smart inverters to minimize voltage fluctuations and restore nodal voltages to their reference values by adjusting the reactive power support. The proposed approach is validated using the IEEE-123 bus (medium-size) and R3-12.47-2 (large-size) feeders. It is demonstrated that the proposed approach is effective in achieving the CVR objective for unbalanced distribution systems.

optimal control, distributed generation, fluctuati↗

How large are nonadiabatic effects in atomic and diatomic systems?

With recent developments in simulating nonadiabatic systems to high accuracy, it has become possible to determine how much energy is attributed to nuclear quantum effects beyond zero-point energy. Here, we calculate the non-relativistic ground-state energies of atomic and molecular systems without the Born-Oppenheimer approximation. For this purpose, we utilize the fixed-node diffusion Monte Carlo method, in which the nodes depend on both the electronic and ionic positions. Our report shows the ground-state energies for all systems studied, ionization energies for the first-row atoms and atomization energies for the first-row hydrides. We find the ionization energies of the atoms to be nearly independent of the Born-Oppenheimer approximation, within the accuracy of our results. The atomization energies of molecular systems, however, show small effects of the nonadiabatic coupling between electrons and nuclei.

74 ATOMIC AND MOLECULAR PHYSICS↗

Design and implementation of a portable diagnostic system for Thomson scattering and optical emission spectroscopy measurements

A diagnostic system, which has a design goal of high-portability, has been designed at Oak Ridge National Laboratory (ORNL). This project aims at providing measurements of key plasma parameters (ne, Te, ni, Ti) for fusion-relevant devices, utilizing Thomson scattering (TS) and optical emission spectroscopy (OES). The innovative design employs mostly commercial off-the-shelf instrumentation and a traveling team of researchers to conduct measurements at various magnetic-confinement plasma devices. The TS diagnostic uses a Quantel Q-smart 1500 Nd:YAG laser with a 2ω harmonic generator to produce up to 850 mJ of 532 nm laser pulses at 10 Hz. Collection optics placed at the detection port consists of an 11 × 3 optical fiber bundle, where the TS diagnostic uses an 11 × 1 subset array of the fibers, the OES diagnostic uses another 11 fibers, and the remaining fibers are available to the host institution. The detection system is comprised of two separate IsoPlane-320 spectrometers with triple-grating turrets of various line spacing and two PI-MAX 4 intensified CCD detectors, used simultaneously to measure a broad range of ion, impurity, and electron parameters. The self-contained diagnostic package also includes a data processing and storage system. The design and initial implementation of the TS-OES diagnostic system are described. The experiments from the proof-of-principle operation of the portable package on a high density (∼2.5 × 1022 m−3) and low-temperature (∼5 eV) electrothermal arc source at ORNL are also discussed.

Kafle, N. (ORCID:000000028144787X)↗

A Novel Resilience-Oriented Cellular Grid Formation Approach for Distribution Systems with Behind-the-Meter Distributed Energy Resources

This paper presents a resilience-oriented cellular grid formation approach to achieve scalable and reconfigurable community microgrid operations for distribution systems with behind-the-meter distributed energy resources. A set of interconnected solar photovoltaics, energy storage systems, and load is termed as a cell, implying a subset of the grid that can operate independently using its own resources. Cells are identified such that each cell inherently has sufficient energy resources to black start and can provide a certain level of backup power for its load under the loss of utility power supply. The proposed cell formation approach builds on a unique self-organizing map-based method (SomRes) to quantify a system's resilience. Using SomRes and a non-dominated sorting-based genetic algorithm (NSGA-II), a fast and efficient cell formation algorithm is developed to identify cells in a distribution system that are resilient against extreme events. The efficacy of the proposed approach is demonstrated on a numerical model of a real distribution feeder in Colorado, United States.

distributed energy resource↗

IRIS: A Portable Runtime System Exploiting Multiple Heterogeneous Programming Systems

Across embedded, mobile, enterprise, and HPC systems, computer architectures are becoming more heterogeneous and complex. This complexity is causing a crisis in programming systems and performance portability. Several programming systems are working to address these challenges, but the increasing architectural diversity is forcing software stacks and applications to specialize for each architecture. As we show, all of these approaches critically depend on their runtime system for discovery, execution, scheduling, and data orchestration. To address this challenge, we believe that a more agile and proactive runtime system is essential to increase performance portability and improve user productivity. In this regard, we have designed and implemented IRIS: a portable runtime system exploiting multiple heterogeneous programming systems. IRIS can discover available resources, manage multiple diverse programming systems (e.g., CUDA, Hexagon, HIP, Level Zero, OpenCL, OpenMP) simultaneously in the same execution, respect data dependencies, orchestrate data movement proactively, and provide for user-configurable scheduling. Our evaluation on three architectures, ranging from Qualcomm Snapdragon to a Summit supercomputer node, shows that IRIS improves portability across a wide range of diverse heterogeneous architectures with negligible overhead.

Kim, Jungwon↗

Preemptive resource management for dynamically arriving tasks in an oversubscribed heterogeneous computing system

We design resource management heuristics that assign serial tasks to the nodes of a heterogeneous high performance computing (HPC) system. The value of completing these tasks is modeled using monotonically decreasing utility functions that represent the time-varying importance of the task. The value of completing a task is equal to its utility function at the time of its completion. The overall performance of this system is measured using the total utility earned by all tasks during some interval of time. To maximize the performance of such a system where the preemption of tasks is possible, we have designed, analyzed, and compared a set of resource allocation heuristic techniques. We combine two utility-aware heuristics with three different preemption techniques to create six preemption-capable heuristics. We also consider the two utility-aware heuristics without preemption. We use simulation studies to evaluate this set of eight heuristics and compare them with an FCFS heuristic, which is often used in real systems, and random assignments. In general, our set of eight heuristics is able to significantly outperform the comparison heuristics, and the preemption-capable heuristics are able to significantly increase the utility earned compared to the heuristics that do not use preemption. We analyze the performance tradeoffs among the different preemption-capable heuristics under a variety of oversubscribed workload environments.

97 MATHEMATICS AND COMPUTING↗

Examining System-Wide Impacts of Solar PV Control Systems with a Power Hardware-in-the-Loop Platform

High penetration levels of distributed solar PV power generation can lead to adverse power quality impacts such as excessive voltage rise, voltage flicker, and reactive power values that result in unacceptable voltage levels. Advanced inverter control schemes have been proposed that have the potential to mitigate many power quality concerns. However, closed-loop control may lead to unintended behavior in deployed systems as complex interactions can occur between numerous operating devices. In order to enable the study of the performance of advanced control schemes in a detailed distribution system environment, a Hardware-in-the-Loop (HIL) platform has been developed. In the HIL system, GridLAB-D, a distribution system simulation tool, runs in real-time mode at the Pacific Northwest National Laboratory (PNNL) and supplies power system parameters at a point of common coupling to hardware located at the National Renewable Energy Laboratory (NREL). Hardware inverters interact with grid and PV simulators emulating an operational distribution system and power output from the inverters is measured and sent to PNNL to update the real-time distribution system simulation. The platform is described and initial test cases are presented. The platform is used to study the system-wide impacts and the interactions of controls applied to inverters that are integrated into a simulation of the IEEE 8500-node test feeder, with inverters in either constant power factor control or active volt/VAR control. We demonstrate that this HIL platform is well-suited to the study of advanced inverter controls and their impacts on the power quality of a distribution feeder. Additionally, the results from HIL are used to validate GridLAB-D simulations of advanced inverter controls.

14 SOLAR ENERGY↗

DC-Connected Solar Plus Storage Modeling and Analysis for Behind-the-Meter Systems in the System Advisor Model

A detailed model for PV plus DC-connected batteries was developed. This model was compared to an existing ACconnected battery model in the System Advisor Model (SAM) tool using a hypothetical Honolulu residence with a PV plus storage system. The stand-alone PV system was shown to provide the most value; however due to the increased difficulty of PV systems being approved for grid interconnection in Hawaii, it is valuable to install an AC or DC connected battery to enable full PV self-consumption under a less restrictive interconnection option. In that case both battery systems enabled full PV selfconsumption at the residence, requiring no power to be exported to the grid. The DC-connected battery system captured energy from the PV array which would have also been clipped due to inverter limitations. For a PV system with DC/AC ratio of 1.23, the battery configurations produced net-present values within 1% of each other, but when the DC/AC ratio increased to 1.85, the DC-connected system increased the net-present value by 13%.

14 SOLAR ENERGY↗

Can I/O Variability Be Reduced on QoS-Less HPC Storage Systems?

For a production high-performance computing (HPC) system, where storage devices are shared between multiple applications and managed in a best effort manner, I/O contention is often a major problem. In this paper, we propose a balanced messaging-based re-routing in conjunction with throttling at the middleware level. This work tackles two key challenges that have not been fully resolved in the past: whether I/O variability can be reduced on a QoS-less HPC storage system, and how to design a runtime scheduling system that can scale up to a large amount of cores. The proposed scheme uses a two-level messaging system to re-route I/O requests to a less congested storage location so that write performance is improved, while limiting the impact on read by throttling re-routing. An analytical model is derived to guide the setup of optimal throttling factor. We thoroughly analyze the virtual messaging layer overhead and explore whether the in-transit buffering is effective in managing I/O variability. Contrary to the intuition, in-transit buffer cannot completely solve the problem. It can reduce the absolute variability but not the relative variability. The proposed scheme is verified against a synthetic benchmark as well as being used by production applications.

Huang, Dan↗

MO-F-CAMPUS-J-04: Radiation Heat Load On the MR System of the Elekta Atlantic System

Purpose: The Elekta Atlantic system combines a digital linear accelerator system with a 1.5T Philips MRI machine.This study aimed to assess the energy deposited within the cryostat system when the radiation beam passes through the cryostat. The cryocooler on the magnet has a cooling capacity which is about 1 Watt in excess of the cryogenic heat leak into the magnet’s cold mass. A pressure-controlled heater inside the magnet balances the excess refrigeration power such that the helium pressure in the tank is kept slightly above ambient air pressure. If radiation power is deposited in the cold mass then this heater will need less power to maintain pressure equilibrium and if the radiation heat load exceeds the excess cryocooler capacity the pressure will rise. Methods: An in-house CAD based Monte Carlo code based on Penelope was used to model the entire MR-Linac system to quantify the heat load on the magnet’s cold mass. These results were then compared to experimental results obtained from an Elekta Atlantic system installed in UMC-Utrecht. Results: For a field size of 25 cm x 22 cm and a dose rate of 107 mu.min-1, the energy deposited by the radiation beam led to a reduction in heater power from 1.16 to 0.73 W. Simulations predicted a reduction to 0.69 W which is in good agreement. For the worst case field size (largest) and maximum dose rate the cryostat cooler capacity was exceeded. This resulted in a pressure rise within the system but was such that continuous irradiation for over 12 hours would be required before the magnet would start blowing off helium. Conclusion: The study concluded that the Atlantic system does not have to be duty cycle restricted, even for the worst case non-clinical scenario and that there are no adverse effects on the MR system. Stephen Towe and David Roberts Both work for Elekta; Ezra Van Lanen works for Philips Healthcare; Johan Overweg works for Philips Innovative Technologies.

60 APPLIED LIFE SCIENCES↗