Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “system voltage”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Detailed Modeling and Response of Demand Response Enabled Appliances

Proper modeling of end use loads is very important in order to predict their behavior, and how they interact with the power system, including voltage and temperature dependencies, power system and load control functions, and the complex interactions that occur between devices in such an interconnected system. This paper develops multi-state time variant residential appliance models with demand response enabled capabilities in the GridLAB-DTM simulation environment. These models represent not only the baseline instantaneous power demand and energy consumption, but the control systems developed by GE Appliances to enable response to demand response signals and the change in behavior of the appliance in response to the signal. These DR enabled appliances are simulated to estimate their capability to reduce peak demand and energy consumption.

demand response↗

Integration of Ultrawide Bandgap Photoconducting Semiconductor Switches into High-Voltage, High-Current Pulser Systems

In this feasibility study we will evaluate the viability of integrating ultrawide bandgap (UWBG) photoconducting semiconductor switches (PCSS) in high-voltage pulser systems capable of driving low-impedance dynamic loads critical for next-generation accelerator and RF-source applications. The project consisted of developing modelling tools that would inform design of UWBG PCSS packages that could be mounted onto conventional circuit boards. Specifically, we are interested in evaluating the following through simulation software: (1) resistance to electrical breakdown (2) proximity effects due to high-frequency skin effect (3) transient behavior from switching (4) effective transmission of RF signals (5) thermal dynamics of the switch under operation (6) sensitivity to inhomogeneities in optical excitation of the material (7) cross-talk effects from parallel switching structures, and (8) susceptibility of system to damaged components. The project resulted in the development of a special-purpose circuit code that implements photoconductivity physics. This code was used to evaluate objectives 1-6 above, identifying a critical requirement associated with the need for fine control of dopant concentrations in the UWBG material to reach an optimal solution for voltage standoff and laser light responsivity requirements. In addition, we identified that the temperature dependence of the electrical conductivity of this material was typically not well-measured and developed a platform for measuring both the “dark” and “illuminated” conductivity on real physical switches in the lab to better inform our models.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Coordination of Networked Microgrids for Supporting Voltages of Bulk Power Systems

Active distribution system resources have the potential to support the bulk power system (BPS) during abnormal conditions, increasing reliability and resilience of power systems and end-use customers. This paper investigates for the first time the BPS voltage support provided by networked microgrids at the feeder level. A peer-to-peer (P2P) communication control framework is introduced to enable the coordination of multiple microgrids in a mixed ownership environment. This allows the microgrids to run a consensus algorithm (CA) to distributedly determine their own reactive power injections. Thus, the reactive power injection contribution is realized in a fair manner by having the same ratio of reactive power injection to the reactive power headroom for all microgrids. The CA implementation and performance within the P2P network framework are demonstrated on the IEEE 39-bus testcase system with 10 microgrids part of the distribution feeder assumed to be connected to one of the BPS buses.

Vu, Thanh Long↗

Performance of a High-Fidelity 4kW-Class Engineering Model PPU and Integration with HiVHAc System

The High Voltage Hall Accelerator (HiVHAc) propulsion system consists of a thruster, power processing unit (PPU), and propellant feed system. An engineering model PPU was developed by Colorado Power Electronics, Inc. funded by NASA's Small Business Innovative Research Program. This PPU uses an innovative 3-phase resonant converter to deliver 4 kW of discharge power over a wide range of input and output voltage conditions. The PPU includes a digital control interface unit that automatically controls the PPU and a xenon flow control module (XFCM). It interfaces with a control computer to receive highlevel commands and relay telemetry through a MIL-STD-1553B interface. The EM PPU was thoroughly tested at GRC for functionality and performance at temperature limits and demonstrated total efficiencies a high as 95 percent. Integrated testing of the unit was performed with the HiVHAc thruster and the XFCM to demonstrate closed-loop control of discharge current with anode flow. Initiation of the main discharge and power throttling were also successfully demonstrated and discharge oscillations were characterized.

Power Processing Unit↗

Performance of a High-Fidelity 4kW-Class Engineering Model PPU and Integration with HiVHAc System

The High Voltage Hall Accelerator (HiVHAc) propulsion system consists of a thruster,power processing unit (PPU), and propellant feed system. An engineering model PPU was developed by Colorado Power Electronics, Inc. funded by NASA's Small Business Innovative Research Program. This PPU uses an innovative 3-phase resonant converter to deliver 4 kW of discharge power over a wide range of input and output voltage conditions.The PPU includes a digital control interface unit that automatically controls the PPU and a xenon flow control module (XFCM). It interfaces with a control computer to receive high level commands and relay telemetry through a MIL-STD-1553B interface. The EM PPU was thoroughly tested at GRC for functionality and performance at temperature extremes and demonstrated total efficiencies a high as 95 percent. It was integrated with the HiVHAc thruster and the XFCM to demonstrate closed-loop control of discharge current with anode flow. Initiation of the main discharge and power throttling were also successfully demonstrated and discharge oscillations were characterized.

Electric Propulsion↗

Power system effects and mitigation recommendations for DER cyberattacks

Extensive deployment of interoperable distributed energy resources (DER) is increasing the power system cyber security attack surface. National and jurisdictional interconnection standards require DER to include a range of autonomous and commanded grid‐support functions, which can drastically influence power quality, voltage, and bulk system frequency. Here, the authors investigate the impact to the cyber‐physical power system in scenarios where communications and operations of DER are controlled by an adversary. The findings show that each grid‐support function exposes the power system to distinct types and magnitudes of risk. The physical impact from cyber actions was analysed in cases of DER providing distribution system voltage regulation and transmission system support. Finally, recommendations are presented for minimising the risk using engineered parameter limits and segmenting the control network to minimise common‐mode vulnerabilities.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Electric field reversals resulting from voltage waveform tailoring in Ar/O 2 capacitively coupled plasmas sustained in asymmetric systems

The etching of nanometer scale high-aspect-ratio (HAR) features into dielectric materials in low pressure radio frequency excited plasmas is often accompanied by charge accumulation inside the features which can slow etching rates and produce distortions such as twisting. The intra feature charging is at least partially produced by differences in electron and ion energy and angular distributions (EADs). Positive ions, accelerated to high energies having narrow angular spreads by the sheath electric field, can penetrate deeply into HAR features. Electrons typically arrive at the wafer with nearly thermal and isotropic distributions and do not penetrate deeply into HAR features. These disparities lead to differential charging of the inside of the feature, which can lead to reductions in etch rate and feature distortion due to ion deflection. With in-creasing aspect ratio of features, charging challenges are expected to continue for the foreseeable future. In this work, the use of tailored voltage waveforms in geometrically asymmetric capacitively coupled plasmas sustained in Ar/O 2 at 40 mTorr was computationally investigated with the goal of shaping the EAD of electrons incident onto the substrate to address differential charging. The tailored waveform consisted of a sinusoidal wave and its higher harmonics with a fundamental frequency of 1 MHz. Further, we found that electric field reversals in the sheath and presheath can occur during the anodic portion of the cycle. The electric field reversal increases the energy and decreases the angular spread of electrons incident onto the substrate. The magnitude of the electric field reversal can be controlled by the phase angle of the even harmonics and the gas composition. Due to its electronegative nature, increasing mole fractions of O 2 impedes electron transport to the surface which further increases the electric field reversal.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A Novel Approach for Voltage Control in Electrical Power Distribution Systems

This paper proposes a novel approach for voltage control in 3-phase unbalanced distribution systems. The approach is based on the change of the magnetizing reactances of the voltage regulators in the system. We used an augmented Lagrangian-based optimization model to determine the optimal settings on a modified IEEE 123 Bus Test System with large PV penetration. Simulations were performed on a minute-based resolution either by controlling regulators or by controlling the magnetizing reactances of the regulators only. The simulation results presented and their comparison show that the control of the magnetizing reactances of the regulators may improve the voltage profile, and may be an addition or alternative to both traditional voltage control devices, such as capacitors, tap changers, and newer devices such as smart inverters.

Ceylan, Oguzhan↗

Suppressed oxygen extraction and degradation of LiNixMnyCozO2 cathodes at high charge cut-off voltages

The capacity degradation mechanism in lithium nickel-manganese-cobalt oxide (NMC) cathodes (LiNi1/3Mn1/3Co1/3O2 (NMC333) and LiNi0.4Mn0.4Co0.2O2 (NMC442)) during high-voltage (cut-off of 4.8 V) operation has been investigated. In contrast to NMC442, NMC333 exhibits rapid structural changes including severe micro-crack formation and phase transformation from a layered to a disordered rock-salt structure, as well as interfacial degradation during high-voltage cycling, leading to a rapid increase of the electrode resistance and fast capacity decline. The fundamental reason behind the poor structural and interfacial stability of NMC333 was found to be correlated to its high Co content and the significant overlap between the Co3+/4+ t(2g) and O2- 2p bands, resulting in oxygen removal and consequent structural changes at high voltages. In addition, oxidation of the electrolyte solvents by the extracted oxygen species generates acidic species, which then attack the electrode surface and form highly resistive LiF. These findings highlight that both the structural and interfacial stability should be taken into account when tailoring cathode materials for high voltage battery systems

Environmental Molecular Sciences Laboratory↗

Method for improved voltage determination for pulsed power systems utilizing a magnetically insulated transmission line

Because the voltage is difficult to measure in a magnetically insulated transmission line (MITL), measurement of the currents flowing in the cathode and anode are often used with MITL theory to estimate the voltage in a given experiment. However, that estimate contains a space charge correction term whose magnitude depends on what is referred to as the g factor that describes the distribution of charge and current in the electron flow layer in the MITL. Typically, g is on the order of unity but the accuracy of the voltage estimate depends on its actual value. While the space charge correction term is small when the MITL flow is strongly insulated, it is particularly important near self-limited MITL flow. System parameters that affect the distribution of electron flow are studied here at self-limited flow in order to illustrate this matter and develop a methodology to improve the voltage determination.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Coordinated Use of Smart Inverters with Legacy Voltage Regulating Devices in Distribution Systems with High Distributed PV Penetration — Increase CVR Energy Savings

This paper studies the coordinated use of smart inverters with legacy voltage regulating devices to help increase the energy savings from conservation voltage reduction (CVR) in distribution systems with high photovoltaic penetration. Two voltage optimization algorithms are developed to evaluate the CVR benefit by considering two types of smart inverter functions: aggregated reactive power control and autonomous volt/VAR control. In each algorithm, smart inverters are coordinately controlled with the operation of legacy voltage regulating devices including load tap changers and capacitor banks. Both algorithms are tested on representative utility distribution system models. In conclusion, simulation results demonstrate that the proposed algorithms can achieve around 1.8-3.6% energy savings when only using legacy voltage regulating devices and an additional 0.3-0.9% when adding smart inverters.

14 SOLAR ENERGY↗

Deep Reinforcement Learning Enabled Physical-Model-Free Two-Timescale Voltage Control Method for Active Distribution Systems

Active distribution networks are being challenged by frequent and rapid voltage violations due to renewable energy integration. Conventional model-based voltage control methods rely on accurate parameters of the distribution networks, which are difficult to achieve in practice. This paper proposes a novel physical-model-free two-timescale voltage control framework for active distribution systems. To achieve fast control of PV inverters, the whole network is first partitioned into several subnetworks using voltage-reactive power sensitivity. Then, the scheduling of PV inverters in the multiple sub-networks is formulated as Markov games and solved by a multi-agent soft actor-critic (MASAC) algorithm, where each subnetwork is modeled as an intelligent agent. All agents are trained in a centralized manner to learn a coordinated strategy while being executed based on only local information for fast response. For the slower time-scale control, OLTCs and switched capacitors are coordinated by a single agent-based SAC algorithm using the global information with considering control behaviors of the inverters. Particularly, the two-level agents are trained concurrently with information exchange according to the reward signal calculated from the data-driven surrogate model. Comparative tests with different benchmark methods on IEEE 33-and 123-bus systems and 342-node low voltage distribution system demonstrate that the proposed method can effectively mitigate the fast voltage violations and achieve systematical coordination of different voltage regulation assets without the knowledge of accurate system model.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Investigation and Feasibility Assessment of TOPAZ-2 Derivations for Space Power Applications

The ability to provide continuous power at significant levels is of utmost importance for many space missions, from simple satellite operations to manned Mars missions. One of the main problems faced in delivering solar or chemical space power in the tens of kW range, is the increasingly massive nature of the power source and the costs associated with its launch, operation and maintenance. A national program had been initiated to study the feasibility of using certain advanced technologies in developing an efficient lightweight space power source. The starting point for these studies has been the Russian TOPAZ-2 space reactor system, with the ultimate goal to aid in the development of a TOPAZ-2 derivative which will be ready for flight by the year 2000. The main objective of this project has been to perform feasibility assessment and trade studies which would allow the development of an advanced space nuclear power system based on the in-core thermionic fuel element technology currently used in the Russian TOPAZ-2 reactor. Two of the important considerations in developing the concept are: (1) compliance of the current TOPAZ-2 and of any advanced designs with U.S. nuclear safety expectations, and (2) compliance of the design with the seven years lifetime requirement. The project was composed of two major phases. The initial phase of the project has concentrated on understanding the TOPAZ-2 thermionic reactor in sufficient detail to allow several follow-on tasks. The primary interest during this first phase has been given on identifying the potential of the TOPAZ-2 design for further improvements. The second phase of the project has focused on the feasibility of a TOPAZ-2 system capable of delivering 30-50 kWe. Towards the elimination of single-point failures in the load voltage regulation system an active voltage regulator has been designed to be used in conjunction with the available shunt load voltage regulator. The possible use of a dual-loop, model-based adaptive control system for load-following in the TOPAZ-2 has also been investigated. The objective of this fault-tolerant, autonomous control system is to deliver the demanded electric power at the desired voltage level, by appropriately manipulating the neutron power through the control drums. As a result, sufficient thermal power is produced to meet the required demand in the presence of dynamically changing system operating conditions and potential sensor failures. The designed controller is proposed for use in combination with the currently available shunt regulators, or as a back-up controller when other means of power system control, including some of the sensors, fail.

Parlos, Alexander G.↗