Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “system validation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Design and Validation of Mechanical & Autonomous Systems in Harsh Environments [Poster]

The autonomous systems within the Mobile Hot Cell provide advanced capabilities over traditional hot cells, pushing the boundaries of these systems in harsh environments. The degraded state of some radiological devices and the variety of designs present a series of challenges that require innovative tooling and procedural solutions. By leveraging technical knowledge and experience from disposition experts at SwRi and other institutions, initial design concepts were produced using rapid prototyping techniques. These concepts were then validated and optimized in a non-hazardous test bed, resulting in iterative improvements at minimal cost.

07 - ISOTOPES AND RADIATION SOURCES↗

Strategies for Validation Testing of Ground Systems

In order to accomplish the full Vision for Space Exploration announced by former President George W. Bush in 2004, NASA will have to develop a new space transportation system and supporting infrastructure. The main portion of this supporting infrastructure will reside at the Kennedy Space Center (KSC) in Florida and will either be newly developed or a modification of existing vehicle processing and launch facilities, including Ground Support Equipment (GSE). This type of large-scale launch site development is unprecedented since the time of the Apollo Program. In order to accomplish this successfully within the limited budget and schedule constraints a combination of traditional and innovative strategies for Verification and Validation (V&V) have been developed. The core of these strategies consists of a building-block approach to V&V, starting with component V&V and ending with a comprehensive end-to-end validation test of the complete launch site, called a Ground Element Integration Test (GEIT). This paper will outline these strategies and provide the high level planning for meeting the challenges of implementing V&V on a large-scale development program. KEY WORDS: Systems, Elements, Subsystem, Integration Test, Ground Systems, Ground Support Equipment, Component, End Item, Test and Verification Requirements (TVR), Verification Requirements (VR)

Annis, Tammy↗

Global Techno-Economic Performance of Bifacial and Tracking Photovoltaic Systems

Although most of the current photovoltaic (PV) system installations use monofacial modules with fixed-tilt mounting structures, bifacial modules, trackers, and the combination of them are also getting more attention as potential candidates to further reduce the PV levelized cost of electricity (LCOE). This work is then the first to present a worldwide analysis on the yield potential and cost-effectiveness of PV farms composed of monofacial fixed-tilt and single/dual (1T/2T) tracker installations, as well as their bifacial counterparts. Our approach starts by estimating the irradiance reaching the front and rear surface of the modules for the different system designs (validated based on data from real PV systems and results from the literature) to estimate their energy production (row-row shading is neglected). Subsequently, the overall system cost during their 25-year lifetime is factored in, and LCOE is obtained. The results reveal that bifacial-1T installations increase energy yield by 35% and reach the lowest LCOE for the majority of the world (93.1% of the land area). Although dual axis trackers achieve the highest energy generation — especially for bifacial modules — their cost is still too high, and are therefore not as cost-effective. Sensitivity analyses based on the Monte Carlo and region sensitivity approach are performed to analyze the impact of input assumptions on the calculated LCOE. These reveal that our conclusions are robust in general but exact configuration to choose depends on specific site conditions. This investigation is not only of interest to the scientific community, but also can be used as a guide for PV installation companies and investors to determine the most suitable technology for a particular location.

14 SOLAR ENERGY↗

High-resolution leaf area index maps generated from unoccupied aerial system, Teller Mile 27, Seward Peninsula, Alaska

Leaf area index (LAI), a measure of the amount of one-side leaf area per ground unit, is an important indicator of plant carbon, energy, and water cycle. In the heterogeneous Arctic landscapes, it has been challenging to accurately measure LAI across species and space needed for Earth system model validation. Here, we use multispectral unoccupied aerial systems (UASs) to scale up and map leaf area index (LAI) , in a low-Arctic tundra landscape on the Seward Peninsula, Alaska. We linked previous published LAI measurements with high-resolution, UAS-collected multispectral data collected over the region of Next Generation Ecosystem Experiments in the Arctic (NGEE Arctic)’s Teller Mile Maker 27 site in 2022 to develop random forest (RF) machine learning models to predict and map LAI. 100 RF models were developed to account for uncertainties in ground LAI plot measurements and process scaling. This dataset includes a raster (*.tif) map of the mean LAI value of the 100 RF models, a raster (*.tif) map of the standard deviation of the RF-modeled LAI data, and a user guide (*.pdf).

54 ENVIRONMENTAL SCIENCES↗

Validation of Thermodynamic Vent System Performance using Thermal Desktop

Cryogenic fluid management (CFM) for in-space propulsion systems is crucial to enabling future space missions. A means to control the pressure inside a propellant tank is necessary to prevent the venting of liquid propellant in microgravity environments. A thermodynamic vent system (TVS) is one way to regulate the pressure and temperature of the fluid inside a tank. A previous study created a simplified model of a TVS in a two-phase cryogenic heat exchanger. The TVS expands the working fluid across a Joule-Thomson (J-T) device and routes the cooled fluid through the heat exchanger to remove heat from the surrounding fluid. The model was able to predict the TVS heat extraction performance and was validated against experimental data using the same hardware. This study expands the model of the TVS into Thermal Desktop (TD) and recreates the results from both the original model and the experimental data. This new TD model has the potential to be used to predict TVS heat extraction performance in cryogenic propellant tanks for future space missions.

Cryogenic Fluid Management↗

Evidence flow graph methods for validation and verification of expert systems

The results of an investigation into the use of evidence flow graph techniques for performing validation and verification of expert systems are given. A translator to convert horn-clause rule bases into evidence flow graphs, a simulation program, and methods of analysis were developed. These tools were then applied to a simple rule base which contained errors. It was found that the method was capable of identifying a variety of problems, for example that the order of presentation of input data or small changes in critical parameters could affect the output from a set of rules.

Becker, Lee A.↗

Validating Requirements for Fault Tolerant Systems Using Model Checking

Model checking is shown to be an effective tool in validating the behavior of a fault tolerant embedded spacecraft controller. The case study presented here shows that by judiciously abstracting away extraneous complexity, the state space of the model could be exhaustively searched allowing critical functional requirements to be validated down to the design level. Abstracting away detail not germane to the problem of interest leaves by definition a partial specification behind. The success of this procedure shows that it is feasible to effectively validate a partial specification with this technique. Three anomalies were found in the system one of which is an error in the detailed requirements, and the other two are missing/ambiguous requirements. Because the method allows validation of partial specifications, it also is an effective methodology towards maintaining fidelity between a co-evolving specification and an implementation.

Schneider, Francis↗

Validation Methods Research for Fault-Tolerant Avionics and Control Systems: Working Group Meeting, 2

The validation process comprises the activities required to insure the agreement of system realization with system specification. A preliminary validation methodology for fault tolerant systems documented. A general framework for a validation methodology is presented along with a set of specific tasks intended for the validation of two specimen system, SIFT and FTMP. Two major areas of research are identified. First, are those activities required to support the ongoing development of the validation process itself, and second, are those activities required to support the design, development, and understanding of fault tolerant systems.

Gault, J. W.↗

System design from mission definition to flight validation

Considerations related to the engineering systems design process and an approach taken to introduce undergraduate students to that process are presented. The paper includes details on a particular capstone design course. This course is a team oriented aircraft design project which requires the students to participate in many phases of the system design process, from mission definition to validation of their design through flight testing. To accomplish this in a single course requires special types of flight vehicles. Relatively small-scale, remotely piloted vehicles have provided the class of aircraft considered in this course.

Batill, S. M.↗

Open‐source photovoltaic model pipeline validation against well‐characterized system data

Abstract All freely available plane‐of‐array (POA) transposition models and photovoltaic (PV) temperature and performance models in pvlib‐python and pvpltools‐python were examined against multiyear field data from Albuquerque, New Mexico. The data include different PV systems composed of crystalline silicon modules that vary in cell type, module construction, and materials. These systems have been characterized via IEC 61853‐1 and 61853‐2 testing, and the input data for each model were sourced from these system‐specific test results, rather than considering any generic input data (e.g., manufacturer's specification [spec] sheets or generic Panneau Solaire [PAN] files). Six POA transposition models, 7 temperature models, and 12 performance models are included in this comparative analysis. These freely available models were proven effective across many different types of technologies. The POA transposition models exhibited average normalized mean bias errors (NMBEs) within ±3%. Most PV temperature models underestimated temperature exhibiting mean and median residuals ranging from −6.5°C to 2.7°C; all temperature models saw a reduction in root mean square error when using transient assumptions over steady state. The performance models demonstrated similar behavior with a first and third interquartile NMBEs within ±4.2% and an overall average NMBE within ±2.3%. Although differences among models were observed at different times of the day/year, this study shows that the availability of system‐specific input data is more important than model selection. For example, using spec sheet or generic PAN file data with a complex PV performance model does not guarantee a better accuracy than a simpler PV performance model that uses system‐specific data.

14 SOLAR ENERGY↗

Development and Validation of Home Comfort System for Total Performance Deficiency/Fault Detection and Optimal Comfort Control

In this project, we developed and tested a learning-based home thermal model that facilitates the operation of a model predictive control (MPC)-based optimization agent and an automated fault detection and diagnosis (AFDD) agent. The home thermal model was constructed using a two-node resistor-capacitor model. Moreover, two accompanying parameter identification methods were introduced, least-squares and optimization. Based on the home thermal model, the MPC-based optimization agent was developed to optimize residential HVAC operation. Using two FDD methods, the AFDD agent was constructed to detect and diagnose two prevalent residential AC faults, airflow reduction and refrigerant undercharge. The home thermal model, along with the MPC-based optimization agent and AFDD agent, were tested at the Norman Test House, Miami Test House, Pacific Northwest National Laboratory (PNNL) Test House A, and PNNL Test House B. Finally, they were also field tested in nine demonstration homes with real occupants.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗