Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “system calibration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Computational Optimization of 133m Xe Production via Neutron Irradiation in a TRIGA Reactor

Here, the Comprehensive Nuclear-Test-Ban Treaty bans all nuclear tests worldwide. As part of treaty compliance, the concentration of radioactive nuclides in the atmosphere is monitored to detect nuclear weapons tests. Radioactive noble gas fission products, specifically radioxenon, can vent into the atmosphere after a nuclear weapons test, even if the test is well contained underground or underwater. Radioxenon thus serves as a signal for nuclear weapons tests. All atmospheric monitoring systems require samples of radioxenon isotopes for detector calibration, quality control, and certification. Here, we present a novel, improved method for creating samples of 133m Xe via neutron irradiation of 132 Xe in the Washington State University TRIGA reactor. 132 Xe neutron absorption results in either 133 Xe or 133m Xe—thermal neutron absorption results in 133m Xe 12% of the time, while fast neutron absorption (above ~1 MeV) results in 133m Xe ~50% of the time. To optimize the production of 133m Xe via neutron absorption in 132 Xe in the thermal TRIGA reactor, spectral tuning using an irradiation chamber is required to maximize the fraction of fast neutrons being absorbed and minimize the number of thermal neutrons interacting with the 132 Xe. We used MCNP to tally 132 Xe absorptions with the isotopic tally function, flux tallies and neutron attenuation to estimate the number of neutrons reaching the 132 Xe through the irradiation chamber, and the adjoint importance function to improve the source strength estimate. Additionally, we performed a heat transfer analysis for safety considerations. It was determined that the use of a 96% enriched 10 B boron carbide chamber, placed next to the fuel elements in reactor position D8, increases the 133m Xe/ 133 Xe activity ratio from a baseline value of 0.3 to 1.0, a 233% increase. Additionally, it was determined that the alpha heating produced in the boron does not become an unmanageable problem in the Washington State University reactor.

37 - INORGANIC, ORGANIC, PHYSICAL AND ANALYTICAL C↗

The ATLAS Fast TracKer system

The ATLAS Fast TracKer (FTK) was designed to provide full tracking for the ATLAS high-level trigger by using pattern recognition based on Associative Memory (AM) chips and fitting in high-speed field programmable gate arrays. The tracks found by the FTK are based on inputs from all modules of the pixel and silicon microstrip trackers. The as-built FTK system and components are described, as is the online software used to control them while running in the ATLAS data acquisition system. Also described is the simulation of the FTK hardware and the optimization of the AM pattern banks. An optimization for long-lived particles with large impact parameter values is included. A test of the FTK system with the data playback facility that allowed the FTK to be commissioned during the shutdown between Run 2 and Run 3 of the LHC is reported. The resulting tracks from part of the FTK system covering a limited $\eta$-$\phi$ region of the detector are compared with the output from the FTK simulation. It is shown that FTK performance is in good agreement with the simulation.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Pressurized Gas Beam Monitor for Extremely High Intensities – Phase II

A novel pressurized gas-filled multi-RF-cavity beam profile monitor has been studied that is simple and robust in high-radiation environments. Charged particles passing through each RF-cavity in the monitor produce intensity-dependent ionized plasma, which changes the gas permittivity. Standard RF techniques to measure the change in quality factor (Q) and frequency (f) as a function of time are then used to determine the change in permittivity and corresponding beam intensity in each cavity in the profile monitor. The sensitivity to beam intensity is adjustable using gas pressure and RF gradient. The performance of the gas-filled beam profile monitor has been numerically simulated to evaluate the sensitivity of permittivity measurements and the effectiveness of calibration strategies. An entire multi-RF-cavity system has been designed and a demonstration test has been prepared.

43 PARTICLE ACCELERATORS↗

A Case Study on Condenser Water Supply Temperature Optimization with a District Cooling Plant

District cooling (DC) continues to proliferate due to increasing global cooling demands and economies of scale benefits; however, most district-scale modeling has focused on heating, and to the best of our knowledge, researchers have yet to model cooling plants featuring waterside economizers in DC settings. With the popular Modelica Buildings library expanding its capabilities to district scale, this study is one of the first to demonstrate how the open-source models can be used for detailed energy and control analysis of a DC plant. For a real-world case study, we developed and calibrated high-fidelity models for a DC system central plant at a college campus in Colorado, USA, and we optimized the condenser water supply temperature (CWST) setpoint for a DC plant across multiple time horizons using the Optimization library in Dymola. Results indicate that annual CWST optimization saves 4.7% annual plant energy, with less than 1% of additional energy savings gained through daily optimization. This confirms previous studies' findings that high frequency CWST optimizations are not necessary for the studied system.

chiller plant↗

Development of an in situ dual-channel thermal desorption gas chromatography instrument for consistent quantification of volatile, intermediate-volatility and semivolatile organic compounds

Abstract. Aerosols are a source of great uncertainty in radiative forcing predictions and have poorly understood health impacts. Most aerosol mass is formed in the atmosphere from reactive gas-phase organic precursors, forming secondary organic aerosol (SOA). Semivolatile organic compounds (SVOCs) (effective saturation concentration, C*, of 10−1–103 µg m−3) comprise a large fraction of organic aerosol, while intermediate-volatility organic compounds (IVOCs) (C* of 103–106 µg m−3) and volatile organic compounds (VOCs) (C* ≥ 106 µg m−3) are gas-phase precursors to SOA and ozone. The Comprehensive Thermal Desorption Aerosol Gas Chromatograph (cTAG) is the first single instrument simultaneously quantitative for a broad range of compound-specific VOCs, IVOCs and SVOCs. cTAG is a two-channel instrument which measures concentrations of C5–C16 alkane-equivalent-volatility VOCs and IVOCs on one channel and C14–C32 SVOCs on the other coupled to a single high-resolution time-of-flight mass spectrometer, achieving consistent quantification across 15 orders of magnitude of vapor pressure. cTAG obtains concentrations hourly and gas–particle partitioning for SVOCs every other hour, enabling observation of the evolution of these species through oxidation and partitioning into the particle phase. Online derivatization for the SVOC channel enables detection of more polar and oxidized species. In this work we present design details and data evaluating key parameters of instrument performance such as I/VOC collector design optimization, linearity and reproducibility of calibration curves obtained using a custom liquid evaporation system for I/VOCs and the effect of an ozone removal filter on instrument performance. Example timelines of precursors with secondary products are shown, and analysis of a subset of compounds detectable by cTAG demonstrates some of the analytical possibilities with this instrument.

54 ENVIRONMENTAL SCIENCES↗

Design and evaluation of a low-cost sensor node for near-background methane measurement

Abstract. We developed a low-cost methane sensing node incorporating two metal oxide (MOx) sensors (Figaro Engineering TGS2611-E00 and TGS2600), humidity and temperature sensing, data storage, and telemetry. We deployed the prototype sensor alongside a reference methane analyzer at two sites: one outdoors and one indoors. We collected data at each site for several months across a range of environmental conditions (particularly temperature and humidity) and methane levels. We explored calibration models to investigate the performance of our system and its suitability for methane background monitoring and enhancement detection, first selecting a linear regression to fit a sensor baseline response and then fitting methane response by the sensor deviation from baseline. We achieved moderate accuracy in a 2 to 10 ppm methane range compared to data from the reference analyzer (RMSE < 0.6 ppm), but we found that the sensor response varied over time, possibly as a result of changes in non-targeted gas concentrations. We suggest that this cross sensitivity may be responsible for mixed results in previous studies. We discuss the implications of our results for the use of these and similar inexpensive MOx sensors for methane monitoring in the 2 to 10 ppm range.

Furuta, Daniel↗

Hydrogen Internal Combustion Engine - Franco Ocampo

This intern poster is personal research on a Hydrogen Internal Combustion Engine. The poster oversees the core problems with the idea of a HICE. The main problem addressed is abnormal combustion which can be a safety hazard firstly, but also mitigate the performance of the engine severely. Solutions include direct fuel injection, alternative cooling systems, and closer attention to valve timing and calibration in relation to fuel delivery.

08 - HYDROGEN↗

Inverter Model Validation and Calibration Using Phasor Measurement Unit Data

As the penetration of inverter-based renewable energy resources increases in the power grid, especially at the distribution and microgrid levels, the need to accurately represent them in planning studies increases as well. However, due to the lack of well-established standard procedures, and vendor reluctance towards the detailed sharing of proprietary models, automated dynamic model validation and parameter calibration tools for inverter based resources (IBRs) remain scarce. This work presents a model validation and parameter calibration platform for representing IBRs with generic phasor-domain models. Phasor measurements of power system events are used for continuous validation using the data playback method, and model parameters are re-calibrated if a significant mismatch between measurements and model response is observed. Unique features of the proposed platform include- (a) an iterative Bayesian optimization approach towards parameter calibration to address a possible mismatch between the structures of generic models implemented in simulation softwares and actual commercial inverters, (b) error metrics designed to account for a possible mismatch between the time resolution of simulation and measurements, and (c) analysis of the measurement-simulation mismatch to provide guidance to engineering personnel regarding model shortcomings. The performance of the platform has been illustrated using both simulated data and field measurements to validate/calibrate inverter models in GridLAB-D.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Implementing a Laser Stabilization System for Trapping Ca+ Ions: an Internship Reflection

At Lawrence Livermore National Laboratory, I contributed to a project developing 3D printed micro ion traps for quantum computing. I designed, implemented, and assessed a laser stabilization system that locked lasers to the frequencies required for calibrating our High Finesse WS8-10 wavelength meter and for laser cooling and trapping of Ca+ ions. I also programmed a Python interface for hardware communication, data collection, and statistical analysis. Additionally, I optimized and aligned laser beam paths, and I implemented a closed digital feedback loop using Proportional, Integral, and Derivative (PID) control parameters. I analyzed both the long-term and short-term behavior of our locked lasers and adjusted PID parameters to enhance performance. Furthermore, I used COMSOL to simulate the capacitance of a linear Paul trap design and predict our trap’s performance. The procedures I developed for the interface, analysis, and simulations will continue to support the ion trapping experiment after my appointment. I strengthened my skills in data analysis, Python coding, and optical alignment for laser systems. My confidence as a researcher grew, particularly in communicating my research. This experience taught me the importance of careful planning and consideration in research and solidified my desire to continue exploring novel quantum technology as an undergraduate

42 ENGINEERING↗

AutoFocus: AI-driven alignment of nanofocusing X-ray mirror systems

We describe the application of an AI-driven system to autonomously align complex x-ray-focusing mirror systems, including mirrors systems with variable focus spot sizes. The system has been developed and studied on a digital twin of nanofocusing X-ray beamlines, built using advanced optical simulation tools calibrated with wavefront sensing data collected at the beamline. We experimentally demonstrated that the system is reliably capable of positioning a focused beam on the sample, both by simulating the variation of a beamline with random perturbations due to typical changes in the light source and optical elements over time, and by conducting similar tests on an actual focusing mirror system.

47 OTHER INSTRUMENTATION↗

Initial Calibration of Large Timing Arrays for the LHC

In preparation for HL-LHC operation a number of new detector systems are being constructed with timing precision on physics objects of <50 picoseconds. These time stamps will reduce the level of pileup induced backgrounds in this LHC phase where the number of interactions per crossing will reach of order 100-200. In the case of CMS, three new systems have initially to be corrected for the usual amplitude walk resulting from the effect of variations in signal size on leading edge timing. In these systems the resulting timing spread (ie walk) ranges from one to four nanoseconds. In the following note we advocate approaching this initial calibration for walk as a calculable correction given early calibration during commissioning -- rather than depending on special collider data to perform the calibration. We derive a simple analytic expression for the walk correction and confirm its effectiveness with lab data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Upgrade of the Lyman-alpha diagnostic system on DIII-D for main chamber edge neutral studies

The LLAMA (Lyman Alpha Measurement Apparatus) pinhole camera diagnostic had previously been deployed on DIII-D to measure radial profiles of the Lyman-α (Ly-α) deuterium neutral line brightness across the plasma boundary in the lower chamber to infer neutral deuterium density and ionization rate profiles. This system has recently been upgraded with a new diagnostic head, named ALPACA, that also encloses two pinhole cameras and duplicates the LLAMA views in the upper chamber. Similar to LLAMA, ALPACA provides two times 20 lines of sight, viewing the plasma edge on the inboard and outboard sides with a radial resolution of ~2.5 cm (FWHM) and an effective time resolution of ~1 ms that allows for the investigation of inter-ELM dynamics. The extended Ly-α system provides better coverage to study neutrals in experiments with various plasma shapes utilizing both the upper and lower divertors. Furthermore, post-campaign calibration of the LLAMA diagnostic has successfully been demonstrated for the first time. This was facilitated by various upgrades to the calibration set-up and detailed measurements of the emissivity distribution of the Ly-α calibration source using a pinhole collimator. It was found that the sensitivity of the inboard LLAMA pinhole camera was reduced by a factor of 2.0 ± 0.2 over the course of six months of plasma operation in 2021. In conclusion, the upgraded Ly-α system, equipped with improved absolute calibration, will provide key input for neutral fueling and pedestal particle transport studies and for 2D edge transport code validation on the DIII-D tokamak.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Calibration and Uncertainty Estimation Using the Ensemble Kalman Filter with a Large Subsurface Flow and Transport Model - 20321

At routinely monitored groundwater contamination sites, periodically measured environmental conditions such as groundwater levels and contaminant concentrations are used to inform and confirm a conceptual site model (CSM) and guide the development and calibration of a numerical groundwater flow and transport model. The calibration of groundwater flow and transport models after each measurement (sampling) event can illuminate deficiencies in a CSM, identify areas where additional monitoring is warranted, and predict the behavior of the system to guide decision making. However, manual and automated (e.g. PEST) model calibration tools can be time-consuming and computationally expensive to implement after each sampling event. Perhaps as a result, such calibration tools generally utilize all available monitoring data simultaneously rather than sequentially assimilating monitoring data one sampling event at a time as the results from sampling become available. A more real-time data assimilation approach may reduce parameter uncertainty, quantify the value of additional monitoring data, and produce a usable model more quickly and with less effort. To mitigate the potential time-consuming aspects of manual and widely applied automated calibration techniques, a data assimilation algorithm called the ensemble Kalman filter (EnKF) was evaluated as a relatively efficient method of model calibration and uncertainty assessment via the sequential integration of monitoring data into a model. The EnKF was able to successfully and efficiently assimilate monitoring and modeling data to calibrate a complex flow and transport model at a real-world site with significant subsurface heterogeneity, uncertainty, and 12 years of monitoring data (over 4,000 individual measurements of groundwater levels and over 2,500 measurements of contaminant concentrations). Starting with an uncalibrated model data from annual sampling events were sequentially assimilated, and the resultant predication errors and estimated parameter uncertainties were tracked. After all monitoring data were assimilated, both flow and transport residuals at the end of the EnKF process were comparable to those produced via a concurrent PEST calibration effort but required fewer model simulations. Both uncertainty and prediction errors decreased over time. In a real-time application, the adequacy of the model could be assessed after each sampling event. The benefits of such a real-time approach to utilizing monitoring data include reduced costs (in the form of model updates or site characterization efforts), early flagging of possible errors in the CSM, and a reduced risk of overfitting and corresponding increased confidence in model predictions. This tool may be particularly useful compared to other calibration techniques (e.g. manual, PEST) when model runtimes are long, calibration parameters are many, or parameter uncertainty is large. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Plutonium-238 Loadout Calorimeter Return To Service

The calorimeter in the transfer area in Building 7920 at the US Department of Energy’s Oak Ridge National Laboratory is used to measure the amount of 238 Pu in the Plutonium Heat Source Oxide. The calorimetry measurement is taken after the oxide is packaged in an ORISC (Oak Ridge Inner Shipping Capsule)/FSO (Fuel Storage Outer) assembly before loading into the Containment Vessel and shipping container. The equipment is used in three specific configurations: zero measurement (nothing in the sample cup), FSO measurement (actual measurement of 238 Pu), and reference calibration measurement (using the reference FSO as a known heat source). System checks were performed in July 2023 in preparation for scheduled material loadout. During these checks, personnel discovered that the reference FSO had experienced an electrical short in the heater cable and was no longer functional. The calorimeter was in the reference calibration measurement configuration at this time. Facility management was notified when the damage was discovered. The data from the Yokogawa recorder were pulled and analyzed for a span of time between September 2022 and July 2023. An unusual spike was found in the sample cup temperature data that started on October 19, 2022, and ended on October 20, 2022. The sample cup reached a temperature of 191.1°C. The maximum allowable temperature for the calorimeter thermopile to reach is 220°C based on the manufacturer statement provided in Appendix B of this report [1]. The calorimeter thermopile and the sample cup thermocouple are physically close to each other; therefore, the data suggest that the calorimeter itself never saw a temperature in excess of 191.1°C. Physical damage present on the cable, tape, and insulation suggests that the temperature reached a higher value in some locations within the sample cup than the data shows. Because of this discrepancy, testing of the calorimeter was required to confirm that the calorimeter is functioning the same as it was before the electrical short. The intent of this report is to assess the functionality of the calorimeter and determine if it is acceptable to use for 238 Pu loadout material measurement. Testing showed that the calorimeter is functionally equivalent to the initial calibration that was performed in the summer of 2021, and thus, the calorimeter was cleared to be used for its intended purposes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fast Sideband Control of a Multimode Cavity Memory with Weak Dispersive Coupling to a Transmon

Mitigating ancilla-mediated error channels is a critical challenge in controlling high-quality superconducting cavities using circuit quantum electrodynamics (cQED). We address this by weakening the dispersive coupling while demonstrating fast, high-fidelity multimode control through transmon-mediated sideband interactions. We implement transmon-cavity SWAP gates with speeds up to 30 times larger than the bare dispersive coupling. Combined with transmon rotations, this enables universal state preparation in a single mode, though achieving unitary gates and extending control to multiple modes remains a challenge. In this work, we overcome this limitation by introducing two control strategies: (i) a shelving technique that stores populations in sideband-transparent states, and (ii) a method that exploits the dispersive shift to implement photon-number-selective transmon-cavity SWAP gates. We use these protocols to prepare Fock and binomial code states across any of the ten modes of a multimode cavity with millisecond coherence times—serving as a multimode quantum memory. We demonstrate unitaries that encode and decode an arbitrary qubit state from the transmon into corresponding vacuum and Fock state superpositions, as well as entangled NOON states of cavity mode pairs—a scheme extendable to arbitrary multimode Fock encodings in the cavity modes. Furthermore, we implement a new binomial encoding gate that converts arbitrary transmon superpositions into binomial code states in any cavity mode at a rate exceeding the dispersive shifts in our system, achieving an average post-selected state fidelity of 96.3% in a 4 μ⁢s gate time. By using precalibrated transmon and sideband pulses, our work demonstrates multimode control with significantly reduced calibration overhead, enabling efficient unitary operations using sideband interactions in multimode cQED systems.

Huang, Jordan [Rutgers Univ., Piscataway, NJ (Unit↗

PROTOCALC, a W -band Polarized Calibrator for Cosmic Microwave Background Telescopes: Application to Simons Observatory and CLASS

Current- and next-generation cosmic microwave background (CMB) experiments will measure polarization anisotropies with unprecedented sensitivities. The need for high precision in these measurements underscores the importance of gaining a comprehensive understanding of instrument properties, with a particular emphasis on the study of the beam properties, and especially their polarization characteristics and the measurement of the polarization angle. In this context, a major challenge lies in the scarcity of millimeter polarized astrophysical sources with sufficient brightness and calibration knowledge to meet the stringent accuracy requirements of future CMB missions. This led to the development of a drone-borne calibration source designed for the frequency band centered on approximately 90 GHz, matching a commonly used channel in ground-based CMB measurements. The Prototype Calibrator for Cosmology, PROTOCALC, has undergone thorough in-lab testing, and its properties have been subsequently modeled through simulation software integrated into the standard Simons Observatory analysis pipeline. Moreover, the PROTOCALC system has been tested in the field, having been deployed twice on calibration campaigns with CMB telescopes in the Atacama Desert. The data collected constrain the roll angle of the source with a statistical accuracy of 0$^°_•$045.

79 ASTRONOMY AND ASTROPHYSICS↗

Long-term calibration and validation of stability of the Auger Engineering Radio Array using the diffuse Galactic radio emission

The Auger Engineering Radio Array (AERA) measures radio emission from high-energy extensive air showers. Consisting of 153 autonomous radio-detector stations spread over 17 km^2, it detects radio waves in the frequency range of 30 to 80 MHz. Accurate characterization of the detector response is crucial for proper interpretation of the collected data. Previously, this was achieved through laboratory measurements of the analog chain and simulations and measurements of the antenna's directional response. In this paper, we perform an absolute calibration using the continuously monitored sidereal modulation of the diffuse Galactic radio emission. Calibration is done by comparing the average frequency spectra recorded by the stations with predictions from seven different models of the full radio sky, accounting for the system response, which includes the antenna, filters, and amplifiers. The analysis of the calibration constants over a period of seven years shows no relevant and no significant ageing effect in the AERA antennas. This result confirms the long-term stability of the detector stations and demonstrates the possibility for a radio detector to effectively monitor ageing effects of other detectors operating over extended periods.

Antennas↗

Real-Time GPU-Accelerated OFDR With an Integrated Auxiliary Interferometer

A GPU-accelerated optical frequency domain reflectometry (OFDR) system with an improved integrated auxiliary interferometer is proposed. Unlike conventional approaches that require separate auxiliary interferometers and multiple detection channels, the proposed OFDR system embeds this functionality directly into the signal via an intentional beat component. This enables self-calibration of laser nonlinearity while maintaining a cost-effective hardware configuration. Building on this simplified configuration, the system leverages GPU acceleration with an NVIDIA RTX 4070 Ti to achieve real-time performance, delivering high-throughput signal processing for continuous OFDR interrogation. The signal processing pipeline comprises signal capture, resampling for nonlinearity compensation, and frequency shift computation, all optimized for parallel execution. Hardware benchmarking demonstrates substantial acceleration over CPU implementations, achieving up to a 45× speedup for resampling and frequency shift computations and enabling processing latencies below 30 ms. Thermal response validation is conducted under two complementary scenarios: localized heating using a water bath and cryogenic-temperature conditions using liquid nitrogen. Under localized heating, the system achieves an accuracy of 0.249 °C with a thermal sensitivity of 5.971 GHz/°C, while cryogenic-temperature validation demonstrates a frequency shift response with a sensitivity of 2.383 GHz/°C and an accuracy of 2.04 °C. The high acceleration of the proposed GPU-accelerated OFDR system and its accuracy are achieved by exploiting CUDA-based stride indexing, enabling efficient parallel segmentation and processing of large datasets without additional memory copies. The benchmarking results confirm the robustness, accuracy, and deployability of the proposed OFDR system across a wide temperature range, establishing it as a practical platform for real-time distributed fiber sensing in structurally dynamic environments.

Harb, Salah [Lawrence Berkeley National Laboratory↗