Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “system calibration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Studying MeV Scale Neutron Interactions in DUNE ND-LAr 2x2 Demonstrator

The Deep Underground Neutrino Experiment (DUNE) is a long-baseline neutrino oscillation experiment designed to make high-precision measurements of neutrino oscillation parameters and probe for new physics using a neutrino beam produced at Fermilab and measured at a near detector complex and a far detector located 1,300 km away at the Sanford Underground Research Facility. Precise neutrino energy reconstruction is essential for these measurements, with neutron production in neutrino–argon interactions representing a significant source of systematic uncertainty, as neutrons can carry away significant energy, making their detection and characterization crucial. DUNE’s near detector complex includes ND-LAr, a Liquid Argon Time Projection Chamber (LArTPC) detector designed to mirror the far detector technology and constrain neutrino–argon interaction systematics. The DUNE 2x2 Demonstrator, a pixelated LArTPC based on the ArgonCube design, serves as a prototype for ND-LAr. During 2x2 operations from October to November 2026, an Americium–Beryllium (AmBe) neutron source was deployed near the detector cryostat to obtain a high-statistics sample of neutron interactions. This poster presents progress in studying MeV-scale neutron interactions in this dataset by identifying de-excitation gammas from neutron capture on argon, providing a method for neutron identification and charge readout system calibration in future DUNE detectors.

Mao, Edgar [Syracuse U.] (ORCID:0009000600893306)↗

A calibration means for spectrum analyzers

Spectrum analyzer calibration system is rapid and provides an accurate family of adjustable markers at any point in the spectrum. Pulse width controls determine the number of markers. The unit operates with a repetition rate from 300 cps to 40 kc at a center frequency from 10 kc to 2 Mc.

Larson, M. S.↗

Precision LWIR calibration and test

Precision calibration system with adjustable temperature extended radiance source for long wavelength IR radiometer, discussing performance tests

Otte, A. A.↗

A description of the lunar ranging station at McDonald Observatory.

The equipment of this station which has been in operation since the deployment of the first corner reflector by the Apollo 11 astronauts. The McDonald 2.7-m telescope is used for both transmission and reception of pulsed ruby laser light during three 45-minute daily laser runs about three weeks in a month. The present laser pulse width, timing system, calibration procedures, and signal levels are designed to achieve ranging with an accuracy to 1 nanosecond. The data rates obtained since September, 1970, are consistent with the scientific commitments of the lunar ranging program. Most of the over 200 acquisitions obtained have an accuracy to better than plus or minus 30 cm. Details of the telescope matching optics, guiding and timing equipment, and calibration procedures are discussed. Representative lunar range data are included.

Silverberg, E. C.↗

Earth resources sensing technology - 24-channel multispectral sensor system development.

Description of the technology applied to a 24-channel multispectral scanner developed as a tool to investigate the portion of the electromagnetic spectrum between 0.34 and 13.0 microns. Energy reflected or emitted from the terrain and system calibration sources is collected by the scan mirror, reflected into the collecting optics, and brought to focus in a plane containing a square aperture. A dichroic optical element splits the energy which passes through the aperture into two wavelength bands in which wavelengths are greater than and less than 2.0 microns, respectively. These two wavelength bands are dispersed spectrally by two grating spectrometers. The energy from 24 distinct spectral intervals is transformed into electrical signals by 24 detector/preamplifier combinations. These signals then become the inputs to a video processor in an airborne electronics console.

Kessel, J. E.↗

The open-source neutral-mass spectrometer on Atmosphere Explorer-C, -D, and -E.

The open-source mass spectrometer will be used to obtain the number densities of the neutral atmospheric gases in the mass range 1 to 48 amu at the satellite location. The ion source has been designed to allow gas particles to enter the ionizing region with the minimum practicable number of prior collisions with surfaces. This design minimizes the loss of atomic oxygen and other reactive species due to reactions with the walls of the ion source. The principal features of the open-source spectrometer and the laboratory calibration system are discussed.

Nier, A. O.↗

Environmental design criteria

Wind velocities at 140-200 km altitude were observed by a Low-G Accelerometer Calibration System (LOGACS) flown on an Agena satellite during a geomagnetic storm. An interesting wind reversal observed by the satellite at auroral latitudes is satisfactorily explained by the neutral air motion caused by the E x B drift deduced from the ground-based geomagnetic data recorded at stations near the meridian of the satellite orbit.

Wu, S. T.↗

NASA Lyndon B. Johnson Space Center's Metrology Program

Since the establishment in 1962 of the NASA-JSC Metrology Program, the Reference Standards Laboratory has successfully accomplished its goal and objectives. An on-going laboratory surveillance program, established for insuring a continuing validation of the measurements required at the center, is shown to remain at the forefront of modern technology through its involvement in activities such as the NBS sponsored Measurement Assurance Programs and the utilization of an Automatic Calibration System.

Suraci, J. M.↗

An analysis of the upper atmospheric wind observed by LOGACS

Wind velocities at 140 to 200 km altitude were observed by a low-g accelerometer calibration system (LOGACS) flown on an Agena satellite during a geomagnetic storm. An interesting wind reversal observed by the satellite at auroral latitudes is satisfactorily explained by the neutral air motion caused by the E x B drift deduced from the ground-based geomagnetic data recorded at stations near the meridian of the satellite orbit.

Wu, S. T.↗

GEOS-3 phase B ground truth summary

Ground truth data collected during the experiment systems calibration and evaluation phase of the Geodynamics experimental Ocean Satellite (GEOS-3) experiment are summarized. Both National Weather Service analyses and aircraft sensor data are included. The data are structured to facilitate the use of the various data products in calibrating the GEOS-3 radar altimeter and in assessing the altimeter's sensitivity to geophysical phenomena. Brief statements are made concerning the quality and completeness of the included data.

Parsons, C. L.↗

Ground test of the D shaped vented thrust vectoring nozzle

Static ground tests of a large scale lift/cruise thrust vectoring nozzle were conducted to establish: (1) vectoring performance 'in' and 'out' of ground effect; (2) thrust spoilage capability; (3) compatibility of the nozzle with a turbotip fan; and (4) the nozzle structural temperature distribution. Vectoring performance of a short coupled, vented nozzle design on a large scale, (60%) basis was compared with small scale (4.5%) test nozzle results. The test nozzle was a "boilerplate" model of the MCAIR "D" vented nozzle configured for operation with the LF336/J85 turbotip lift fan system. Calibration of the LF336/J85 test fan with a simple convergent nozzle was performed with four different nozzle exit areas to establish reference thrust, nozzle pressure ratio, and nozzle corrected flow characteristics for comparison with the thrust vectoring nozzle data. Thrust vectoring tests with the 'D' vented nozzle were conducted over the range of vector angles between 0 and 117 deg for several different nozzle exit areas.

Esker, D. W.↗

Absolute radiometric measurements of the emission from a BRV source at 34 nm

The paper reports measurements of the time integrated spectral intensity near 34 nm of a BRV (Balloffet-Romand-Vodar) source of emission continuum. The transmittance profile of the combined filters is presented and the percent efficiency (electrons per photon) of the calibration system is given as a function of wavelength. It is noted that the BRV source provides an excellent emission continuum for XUV spectroscopy.

Kuehne, M.↗