Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “synchrotron imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Experimental study of energy-dependent angular broadening of MeV electron beams for high-resolution imaging in thick samples

In scanning transmission electron microscopy (STEM), spatial resolution is primarily influenced by the projected size of the electron probe within the specimen. In thin samples, a large semi-convergence angle enables a tightly focused beam and sub-nanometer resolution. However, in thick specimens, resolution is fundamentally limited by transverse beam broadening from multiple large-angle scattering events—for example, a probe with 10 mrad angular divergence can broaden by ∼100 nm over a 10 μm path. Since this broadening scales inversely with beam energy, MeV-STEM offers a promising route for high-resolution imaging in thick materials. To quantitatively assess this effect, we performed high-precision measurements at UCLA’s PEGASUS beamline, characterizing beam divergence and intensity profiles for 3–8 MeV electrons transmitted through a wedged-silicon sample of varying thickness. Our results reconcile discrepancies among analytical models and validate Monte Carlo simulations. Here, we find that increasing beam energy from 3.0 to 5.8 MeV reduces angular broadening by a factor of 2.6, with diminishing returns observed at 7.6 MeV. These findings provide a quantitative framework for optimizing MeV-STEM parameters in high-resolution imaging of thick biological and microelectronic specimens, and for guiding beam energy selection in other advanced imaging modes beyond STEM.

36 MATERIALS SCIENCE↗

Roles of Mn and Co in Ni-rich layered oxide cathodes synthesized utilizing a Taylor Vortex Reactor

It is reported that layered oxides, composed of nickel, manganese, and cobalt (NMC), are sought after as cathode materials which provide improved energy density, cycle life, and safety in commercial lithium ion batteries (LIBs). Increasing Ni contents higher than 80% can provide even higher practical discharge capacities >200 mAh/g and similar to ~4 V discharge potential vs Li/Li + , making them promising cathodes for next generation LIBs. However, rapid capacity fade during cycling and heat-related safety concerns are delaying their successful transition to industry. We report systematic performance optimization of LiNiO 2 , LiNi 0.9 Mn 0.1 O 2 , and LiNi 0.9 Co 0.1 O 2 high Ni layered oxide cathodes synthesized by utilizing a Taylor Vortex Reactor. Co-free LiNi 0.9 Mn 0.1 O 2 cathode showed 200 mAh/g highest discharge capacity at 0.1 C rate with 84% retention after 103 cycles at 0.3C rate while LiNi 0.9 Co 0.1 O 2 cathode showed higher initial but poor cycle life (225 mAh/g highest discharge capacity at 0.1C rate with only 56% capacity retention after 103 cycles at 0.3 C rate. Synchrotron based X-ray diffraction (SXRD), X-ray absorption spectroscopy (XAS) and focused ion beam (FIB) imaging of pristine and cycled cathodes after 103 cycles provided important information on degradation mechanism. The roles of Mn and Co on layered structure formation, charge balance, cationic mixing, and electrochemical performance were elucidated using the crystallographic information from XRD refinement and electronic state analysis from XAS providing valuable information to design future Ni-rich layered oxide cathodes.

25 ENERGY STORAGE↗

Constraints on magnetism and correlations in RuO 2 from lattice dynamics and Mössbauer spectroscopy

We provide experimental evidence for the absence of a magnetic moment in bulk RuO 2 , a candidate altermagnetic material, by using a combination of Mössbauer spectroscopy, nuclear forward scattering, inelastic X-ray and neutron scattering, and density functional theory calculations. Using complementary Mössbauer and nuclear forward scattering, we determine the Ru magnetic hyperfine splitting to be negligible. Inelastic X-ray and neutron scattering-derived lattice dynamics of RuO 2 are compared to density functional theory calculations of varying flavors. Comparisons among theory with experiments indicate that electronic correlations, rather than magnetic order, are key in describing the lattice dynamics.

Mössbauer spectroscopy↗

NuSTAR broad-band X-ray observation campaign of energetic pulsar wind nebulae in synergy with VERITAS, HAWC and Fermi gamma-ray telescopes

We report recent progress on the on-going NuSTAR observation campaign of 8 TeV-detected middle-aged pulsar wind nebulae (PWNe). This campaign constitutes a major part of our NuSTAR study of some of the most energetic TeV sources in our Galaxy detected by VERITAS and HAWC. NuSTAR is the first focusing X-ray telescope operating above 10 keV in space with sub-arcminute angular resolution. Broad-band X-ray imaging and spectroscopy data, obtained by NuSTAR, allow us to probe sub-PeV electron populations through detecting synchrotron X-ray radiation. Our targets include PeVatron candidates detected by HAWC, the Boomerang nebula, PWNe crushed by supernova remnant shocks (or relic PWNe) and G0.9‚0.1 in the Galactic Center. Combined with Fermi-LAT data and available TeV data, we aim to provide a complete, multi-wavelength view of a diverse class of middle-aged (~10–100 kyrs old) PWNe. Our NuSTAR analysis detected hard X-ray emission from the Eel and Boomerang PWNe and characterized their broad-band X-ray spectra most accurately. We plan to apply both time-evolution and multi-zone PWNe models to multi-wavelength spectral energy distribution (SED) data over the radio, X-ray, GeV and TeV bands. In this proceeding, we will review our observation campaign and discuss the preliminary results for some PWNe.

79 ASTRONOMY AND ASTROPHYSICS↗

Fast X-ray Nanotomography with Sub-10 nm Resolution as a Powerful Imaging Tool for Nanotechnology and Energy Storage Applications

In the last decade, transmission X-ray microscopes (TXMs) have come into operation in most of the synchrotrons worldwide. They have proven to be outstanding tools for non-invasive ex and in situ 3D characterization of materials at the nanoscale across varying range of scientific applications. However, their spatial resolution has not improved in many years, while newly developed functional materials and microdevices with enhanced performances exhibit nanostructures always finer. Here, optomechanical breakthroughs leading to fast 3D tomographic acquisitions (85 min) with sub-10 nm spatial resolution, narrowing the gap between X-ray and electron microscopy, are reported. These new achievements are first validated with 3D characterizations of nanolithography objects corresponding to ultrahigh-aspect-ratio hard X-ray zone plates. Then, this powerful technique is used to investigate the morphology and conformality of nanometer-thick film electrodes synthesized by atomic layer deposition and magnetron sputtering deposition methods on 3D silicon scaffolds for electrochemical energy storage applications.

36 MATERIALS SCIENCE↗

A new Devonian euthycarcinoid reveals the use of different respiratory strategies during the marine-to-terrestrial transition in the myriapod lineage

Myriapods were, together with arachnids, the earliest animals to occupy terrestrial ecosystems, by at least the Silurian. The origin of myriapods and their land colonization have long remained puzzling until euthycarcinoids, an extinct group of aquatic arthropods considered amphibious, were shown to be stem-group myriapods, extending the lineage to the Cambrian and evidencing a marine-to-terrestrial transition. Although possible respiratory structures comparable to the air-breathing tracheal system of myriapods are visible in several euthycarcinoids, little is known about the mechanism by which they respired. Here, we describe a new euthycarcinoid from Upper Devonian alluvio-lagoonal deposits of Belgium. Synchrotron-based elemental X-ray analyses were used to extract all available information from the only known specimen. Sulfur X-ray fluorescence (XRF) mapping and spectroscopy unveil sulfate evaporation stains, spread over the entire slab, suggestive of a very shallow-water to the terrestrial environment prior to burial consistent with an amphibious lifestyle. Trace metal XRF mapping reveals a pair of ventral spherical cavities or chambers on the second post-abdominal segment that do not compare to any known feature in aquatic arthropods, but might well play a part in air-breathing. Our data provide additional support for amphibious lifestyle in euthycarcinoids and show that different respiratory strategies were used during the marine-to-terrestrial transition in the myriapod lineage.

59 BASIC BIOLOGICAL SCIENCES↗

Referenceless, grating-based, single shot X-ray phase contrast imaging with optimized laser-driven K-α sources

With its ability to efficiently probe low-Z materials, X-ray phase imaging methods have recently raised high interest in multiple fields from biology and medical applications to high energy density (HED) physics. Initially developed with synchrotron light and X-ray tubes, we present a novel grating based Talbot X-ray deflectometer (TXD) diagnostic that was coupled with laser-generated K-α X-ray sources. The multi-terawatt laser (I > 1 × 10 14 W cm -2 ) was used as a testbed for diagnostic development. It was found that X-ray source chromaticity plays an important role in TXD. Indeed, the broadband spectrum of laser-generated X-ray sources may strongly impact image quality and thus diagnostic performance. We qualified X-ray emission from different laser-produced sources and determined laser, target, and deflectometer parameters that optimize TXD performance. We present the first results of referenceless grating-based X-ray imaging at high-power laser facilities and discuss the implications of this new development in HED research.

47 OTHER INSTRUMENTATION↗

Experimental demonstration of coupled multi-peak Bragg coherent diffraction imaging with genetic algorithms

Bragg coherent diffraction imaging has the potential to provide significant insight into the structure-properties relationship for crystalline materials by imaging, with nanoscale resolution, three-dimensional strain fields within individual grains and nanoparticles. The capability of present-day synchrotrons to locate and measure a multiplicity of Bragg reflections from a single grain makes it possible to recover the full strain tensor with nanometer resolution. Recent methods for coupling reconstructions from several peaks to determine the strain tensor have been developed and applied to synthetic data, but have not been applied to experimental data. Here, using a coupled genetic reconstruction algorithm, we reconstruct an experimental data set and demonstrate improvements in the ability to resolve vector-valued displacement fields internal to the particle as compared to what is achieved with a noncoupled approach. The coupled approach developed in this work was also validated on simulated data sets. In both simulated and experimental data, reconstructions from our coupled Bragg peak algorithm show improvements over the noncoupled independent reconstruction method of 5% in terms of accuracy and 53% in terms of consistency.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Characterizing electron-collecting CdTe for use in a 77 ns burst-rate imager

The Keck-PAD (pixel array detector) was developed at Cornell as a burst-rate imager capable of recording images from successive electron bunches (153 ns period) from the Advanced Photon Source (APS). Both Si and hole-collecting Schottky CdTe have been successfully bonded to this ASIC (application-specific integrated circuit) and used with this frame rate. The facility upgrades at the APS will lower the bunch period to 77 ns, which will require modifications to the Keck-PAD electronics to image properly at this reduced period. In addition, operation at high X-ray energies will require a different sensor material having a shorter charge collection time. For the target energy of 40 keV for this project, simulations have shown that electron-collecting CdTe should allow >90% charge collection within 35 ns. This collection time will be sufficient to sample the signal from one frame and prepare for the next. 750 µm-thick electron-collecting Schottky CdTe has been obtained from Acrorad and bonded to two different charge-integrating ASICs developed at Cornell, the Keck-PAD and the CU-APS-PAD. Carrier mobility has been investigated using the detector response to single X-ray bunches at the Cornell High Energy Synchrotron Source and to a pulsed optical laser. The tests indicate that the collection time will meet the requirements for 77 ns imaging.

36 MATERIALS SCIENCE↗

Understanding improved cycling and thermal stability of compositionally graded Ni-rich layered LiNi 0.6 Mn 0.2 Co 0.2 O 2 cathode materials

The concentration gradient is a strategic design, adjusting the distribution of Ni, typically with a higher Ni content in the core and a higher Mn content toward the surface. This design leverages the pivotal role of the Ni/Mn ratio, seeking to optimize cathode performance by balancing Ni's high capacity with Mn's stabilizing effects, particularly at the surface where degradation commonly occurs during cycling. Here, our study delves into the intricate structural and chemical transformations within concentration gradient cathode materials during electrochemical cycling. Utilizing advanced synchrotron X-ray techniques, including hard and soft X-ray absorption spectroscopy (hXAS, sXAS), and nanoscale X-ray imaging, we investigate buried changes in concentration gradient LiNi 0.6 Mn 0.2 Co 0.2 O 2 (CG NMC622). Contrary to conventional assumptions, our findings challenge the notion that cycling stability relies solely on Mn stability. Unraveling the roles of Ni and Mn, we uncover how their individual and collective contributions impact the cathode's overall performance. This investigation transcends established paradigms, shedding light on the crucial mechanisms governing the enhanced cycling stability of Nirich layered cathode materials.

25 ENERGY STORAGE↗

Bragg Coherent Diffraction Imaging for In Situ Studies in Electrocatalysis

Electrocatalysis is at the heart of a broad range of physicochemical applications that play an important role in the present and future of a sustainable economy. Among the myriad of different electrocatalysts used in this field, nanomaterials are of ubiquitous importance. An increased surface area/volume ratio compared to bulk makes nanoscale catalysts the preferred choice to perform electrocatalytic reactions. Bragg coherent diffraction imaging (BCDI) was introduced in 2006 and since has been applied to obtain 3D images of crystalline nanomaterials. BCDI provides information about the displacement field, which is directly related to strain. Lattice strain in the catalysts impacts their electronic configuration and, consequently, their binding energy with reaction intermediates. Even though there have been significant improvements since its birth, the fact that the experiments can only be performed at synchrotron facilities and its relatively low resolution to date (~10 nm spatial resolution) have prevented the popularization of this technique. Herein, we will briefly describe the fundamentals of the technique, including the electrocatalysis relevant information that we can extract from it. Subsequently, we review some of the computational experiments that complement the BCDI data for enhanced information extraction and improved understanding of the underlying nanoscale electrocatalytic processes. We next highlight success stories of BCDI applied to different electrochemical systems and in heterogeneous catalysis to show how the technique can contribute to future studies in electrocatalysis. Finally, we outline current challenges in spatiotemporal resolution limits of BCDI and provide our perspectives on recent developments in synchrotron facilities as well as the role of machine learning and artificial intelligence in addressing them.

bragg coherent diffraction imaging↗

Structural investigation of the temperature-stable relaxor dielectric Ba 0.8 Ca 0.2 TiO 3 -Bi(Mg 0.5 Ti 0.5 )O 3

Aberration corrected scanning transmission electron microscopy (STEM) and electron diffraction have been used to disclose local structure and nano-chemistry in a Ca modified BaTiO 3 -Bi(Mg 0.5 Ti 0.5 )O 3 relax or dielectric ceramic which exhibits high and near-invariant relative permittivity over a wide temperature range. High resolution, synchrotron X-ray diffraction indicated a globally cubic structure ($Pm$$\overline{3}$$m$), but direct atomic-scale imaging by STEM revealed local tetragonal distortions. Nanopolar clusters were identified from B-site atomic displacement vectors measured relative to oxygen ion positions along < 100 > and < 110 > zone axes of integrated differential phase contrast (iDPC) STEM images, highlighting cluster sizes of 2–5 nm. Chemical analysis by STEM-energy dispersive X-ray spectroscopy and full pattern refinements of X-ray powder diffraction data each implied high levels of Bi vacancies within the matrix. The possibility that these A-site vacancies modulate the nanopolar structure and promote flattening of the permittivity-temperature response in this class of dielectric is discussed.

36 MATERIALS SCIENCE↗

Sub-diffractional cavity modes of terahertz hyperbolic phonon polaritons in tin oxide

Abstract Hyperbolic phonon polaritons have recently attracted considerable attention in nanophotonics mostly due to their intrinsic strong electromagnetic field confinement, ultraslow polariton group velocities, and long lifetimes. Here we introduce tin oxide (SnO 2 ) nanobelts as a photonic platform for the transport of surface and volume phonon polaritons in the mid- to far-infrared frequency range. This report brings a comprehensive description of the polaritonic properties of SnO 2 as a nanometer-sized dielectric and also as an engineered material in the form of a waveguide. By combining accelerator-based IR-THz sources (synchrotron and free-electron laser) with s-SNOM, we employed nanoscale far-infrared hyper-spectral-imaging to uncover a Fabry–Perot cavity mechanism in SnO 2 nanobelts via direct detection of phonon-polariton standing waves. Our experimental findings are accurately supported by notable convergence between theory and numerical simulations. Thus, the SnO 2 is confirmed as a natural hyperbolic material with unique photonic properties essential for future applications involving subdiffractional light traffic and detection in the far-infrared range.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Direct observation of C 3 S particle dissolution using fast nano X-ray computed tomography

Tricalcium silicate (C 3 S) occupies 50 % to 70 % of ordinary portland cement (OPC) by mass and it is an important component affecting the hydration of OPC [1], [2], [3], [4], [5], [6], [7]. Generally, the hydration of C 3 S is described by two processes: the dissolution of C 3 S particles and the precipitation of hydration products. While it is understood that the dissolution rates of C 3 S vary with time, more precise measurements are needed to understand this process. Many mechanisms have been proposed to explain the time-evolving dissolution rates of C 3 S [2]. The metastable barrier hypothesis suggests that a thin metastable layer of hydrates forms around the C 3 S particle surface and prohibits the access of grains to the aqueous solution [8], [9], [10], [11], [12]. The slow dissolution step hypothesis suggests that the increased ion concentration from the initial reaction delays the C 3 S dissolution [2], [13], [14], [15], [16], [17]. More recent publications suggest that C 3 S may react differently depending on the existence of crystallographic defects [18], [19], [20]. Etch pits are thought to open on the particle surface during the initial reaction and this contributes to the C 3 S dissolution [21], [22]. As hydrates precipitate and cover these highly reactive surfaces, hydration slows down and the induction period starts [18], [23], [24], [25], [26]. Many experiments have been conducted to test the aforementioned mechanisms. Some hydration studies utilize bulk measurements, such as isothermal calorimetry [27], [28], [29], pore solution analysis [30], quasi-elastic neutron scattering [31], and nuclear magnetic resonance spectroscopy [32], [33]. One limitation of these measurements is that they do not provide direct and detailed information on the individual C 3 S particles. Some other studies utilize imaging techniques, such as scanning electron microscopy (SEM) [34], [35], [36] and transmission electron microscopy (TEM) [37]. However, SEM/TEM cannot track the evolution of individual particles throughout hydration [34], [35], [38], [39], [40] and they do not give insights into the microstructure of materials before hydration [34], [35], [39]. This makes it challenging to draw strong conclusions from only SEM or TEM observations. Synchrotron X-ray tomography techniques have been used more broadly in recent years to study cement hydration. They are not only non-destructive but also able to image a sample in full 3D with resolutions that can reach from micron to nanoscale. Nano computed tomography (nCT) is one technique that has been applied to study cement hydration at the nanoscale [26], [41]. A typical nCT can reach a pixel size from 15 to 65 nm, providing enough detail for observing features <1 μm. However, nCT often takes >0.5 h to finish one scan. This makes the application of this technique on continuous scans for in-situ observations challenging. Fast X-ray computerized tomography (fCT) is another technique that has shown success in studying the time-evolving cement microstructures [20], [42], [43], [44], [45], [46], [47], [48], [49]. Due to the high flux of the X-ray beam from the synchrotron ring, fCT allows a scan to be captured within 1 min at a pixel size of 1 μm. This allows a paste sample to be continuously scanned during the hydration process. However, the micron-sized resolutions limit does not provide detailed insights for particles <5 μm [20], [49]. Fortunately, the combination of nCT and fCT has allowed the development of fast nano X-ray computed tomography (fnCT). fnCT can capture a 3D data set in <2 min at a pixel size of 50 nm. This makes this procedure an exciting method to evaluate hydrating pastes. fnCT collects multiple X-ray radiographs at various rotation angles and generates a 3D model of the scanned sample, which is also referred to as a 3D tomography [50], [51]. In one tomography, the X-ray absorptions of different components (e.g., C 3 S and hydrates) differ as functions of density and chemistry [52], [53]. These X-ray absorption contrasts can be used to extract detailed information about the 3D microstructure [26], [54], [55]. In this paper, fnCT is used to collect time-lapse tomographs of hydrating C 3 S paste from 18 min after mixing to 7 h of hydration. The bulk measurements of anhydrous C 3 S, as well as the microstructural changes of individual C 3 S particles, are directly observed, quantified, and discussed. The dissolution behavior of C 3 S particles at various size scales is systematically analyzed and compared. This work aims to find the relationship between the size of C 3 S particle sizes and their dissolution rates. This provides significant insights into the early-age hydration of C 3 S on length and time scales not previously possible. Because of the magnitude of the data and the substantial amount of observations, this work will solely focus on the change in the anhydrous particles. Changes in the hydration products will be reported in future work.

42 ENGINEERING↗

Self-calibration strategies for reducing systematic slope measurement errors of autocollimators in deflectometric profilometry

Deflectometric profilometers are used to precisely measure the form of beam shaping optics of synchrotrons and X-ray free-electron lasers. They often utilize autocollimators which measure slope by evaluating the displacement of a reticle image on a detector. Based on our privileged access to the raw image data of an autocollimator, novel strategies to reduce the systematic measurement errors by using a set of overlapping images of the reticle obtained at different positions on the detector are discussed. It is demonstrated that imaging properties such as, for example, geometrical distortions and vignetting, can be extracted from this redundant set of images without recourse to external calibration facilities. This approach is based on the fact that the properties of the reticle itself do not change – all changes in the reticle image are due to the imaging process. Firstly, by combining interpolation and correlation, it is possible to determine the shift of a reticle image relative to a reference image with minimal error propagation. Secondly, the intensity of the reticle image is analysed as a function of its position on the CCD and a vignetting correction is calculated. Thirdly, the size of the reticle image is analysed as a function of its position and an imaging distortion correction is derived. It is demonstrated that, for different measurement ranges and aperture diameters of the autocollimator, reductions in the systematic errors of up to a factor of four to five can be achieved without recourse to external measurements.

47 OTHER INSTRUMENTATION↗

Quantum correlation imaging via X-ray parametric down-conversion

Quantum imaging leverages correlations between pairs of photons and has the potential to obtain image information beyond what classical sources provide. Extending this approach to the X-ray regime has been limited by low photon-pair generation rates and the lack of suitable detectors. Here, we demonstrate X-ray coincidence imaging using spontaneous parametric down-conversion (SPDC) and a pixelated area detector with time- and energy-resolved capabilities. This configuration enables simultaneous detection of correlated X-ray photon pairs and coincidence-based imaging of test objects, including a biological specimen. The increased coincidence rate and spatially resolved detection establish a basis for future quantum-enhanced and low-dose X-ray imaging.

Goodrich, Justin C. [Brookhaven National Laborator↗

Small-wedge synchrotron and serial XFEL datasets for Cysteinyl leukotriene GPCRs

Structural studies of challenging targets such as G protein-coupled receptors (GPCRs) have accelerated during the last several years due to the development of new approaches, including small-wedge and serial crystallography. Here, we describe the deposition of seven datasets consisting of X-ray diffraction images acquired from lipidic cubic phase (LCP) grown microcrystals of two human GPCRs, Cysteinyl leukotriene receptors 1 and 2 (CysLT 1 R and CysLT 2 R), in complex with various antagonists. Five datasets were collected using small-wedge synchrotron crystallography (SWSX) at the European Synchrotron Radiation Facility with multiple crystals under cryo-conditions. Two datasets were collected using X-ray free electron laser (XFEL) serial femtosecond crystallography (SFX) at the Linac Coherent Light Source, with microcrystals delivered at room temperature into the beam within LCP matrix by a viscous media microextrusion injector. All seven datasets have been deposited in the open-access databases Zenodo and CXIDB. Here, we describe sample preparation and annotate crystallization conditions for each partial and full datasets. We also document full processing pipelines and provide wrapper scripts for SWSX and SFX data processing. A Correction to this paper has been published: https://doi.org/10.1038/s41597-020-00759-w

97 MATHEMATICS AND COMPUTING↗

Hybrid height and slope figuring method for grazing-incidence reflective optics

Grazing-incidence reflective optics are commonly used in synchrotron radiation and free-electron laser facilities to transport and focus the emitted X-ray beams. To preserve the imaging capability at the diffraction limit, the fabrication of these optics requires precise control of both the residual height and slope errors. However, all the surface figuring methods are height based, lacking the explicit control of surface slopes. Although our preliminary work demonstrated a one-dimensional (1D) slope-based figuring model, its 2D extension is not straightforward. In this study, a novel 2D slope-based figuring method is proposed, which employs an alternating objective optimization on the slopes in the x - and y -directions directly. An analytical simulation revealed that the slope-based method achieved smaller residual slope errors than the height-based method, while the height-based method achieved smaller residual height errors than the slope-based method. Therefore, a hybrid height and slope figuring method was proposed to further enable explicit control of both the height and slopes according to the final mirror specifications. An experiment to finish an elliptical-cylindrical mirror using the hybrid method with ion beam figuring was then performed. Both the residual height and slope errors converged below the specified threshold values, which verified the feasibility and effectiveness of the proposed ideas.

36 MATERIALS SCIENCE↗