Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “synchronized sampling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Nadir Measurements of Carbon Monoxide Distributions by the Tropospheric Emission Spectrometer Instrument Onboard the Aura Spacecraft: Overview of Analysis Approach and Examples of Initial Results

We provide an overview of the nadir measurements of carbon monoxide (CO) obtained thus far by the Tropospheric Emission Spectrometer (TES). The instrument is a high resolution array Fourier transform spectrometer designed to measure infrared spectral radiances from low Earth orbit. It is one of four instruments successfully launched onboard the Aura platform into a sun synchronous orbit at an altitude of 705 km on July 15, 2004 from Vandenberg Air Force Base, California. Nadir spectra are recorded at 0.06/cm spectral resolution with a nadir footprint of 5 x 8 km. We describe the TES retrieval approach for the analysis of the nadir measurements, report averaging kernels for typical tropical and polar ocean locations, characterize random and systematic errors for those locations, and describe instrument performance changes in the CO spectral region as a function of time. Sample maps of retrieved CO for the middle and upper troposphere from global surveys during December 2005 and April 2006 highlight the potential of the results for measurement and tracking of global pollution and determining air quality from space.

carbon monoxide↗

Ultra-Low Noise Laser and Optical Frequency Comb-Based Timing System for the Event Horizon Explorer (EHE) Mission

Very Long Baseline Interferometry (VLBI) requires a highly stable time reference and synchronization system to maintain coherence between observations recorded independently at multiple stations – for example, the array of ground-based radio telescopes that comprise the Event Horizon Telescope (EHT). Instability in the time reference or inaccuracy in the synchronization impacts phase conference and reduces the performance of the VLBI system. For space-based telescopes like the Event Horizon Explorer (EHE) mission, the precision timing system must meet the size, weight, and power (SWaP) constraints of the spacecraft platform and be capable of operating in the space environment. The EHE mission is a proposed extension to the EHT that can improve the angular and time resolution of observations by enabling longer interferometric baselines than are possible on the Earth and sampling a wide range of Fourier spatial frequencies throughout the orbital motion. In this effort, we demonstrate the performance of one option for the EHE mission: the use of a space-qualified, ultra-low noise laser developed as part of the Laser Interferometer Space Antenna (LISA) mission as the timing reference, and an optical frequency comb to transfer the stability of this laser to the microwave regime for instrumentation use. We describe the implementation of the microwave down-conversion, in which the LISA cavity-stabilized laser is locked to a self-referenced optical frequency comb to divide the optical frequency down to 100 MHz. The phase noise of the 100 MHz signal is measured and validated using a phase noise analyzer that is referenced to a separate laboratory ultra-stable laser system. We present the results of this experiment, which demonstrates that the performance of this system meets the EHE requirement: a relative frequency error of 1e-14 from 1 to 30 seconds.

Hannah Tomio↗

Tunable electron beam pulser for picoseconds stroboscopic microscopy in transmission electron microscopes

For two decades, time-resolved transmission electron microscopes (TEM) have relied on pulsed-laser photoemission to generate electron bunches to explore sub-microsecond to sub-picosecond dynamics. Despite the vast successes of photoemission time-resolved TEMs, laser-based systems are inherently complex, thus tend not to be turn-key. In this paper, we report on the successful retrofit of a commercial 200 keV TEM, without an external laser, capable of producing continuously tunable pulsed electron beams with repetition rates from 0.1 GHz up to 12 GHz and a tunable bunch length from tens of nanoseconds down to 10 ps. This innovation enables temporal access into previously inaccessible regimes: i.e., high repetition rate stroboscopic experiments. Combination of a pair of RF-driven traveling wave stripline elements, quadrupole magnets, and a variable beam aperture enables operation of the instrument in (1) continuous waveform (CW) mode as though the instrument was never modified (i.e. convention TEM operation mode, where the electrons from the emission cathode randomly arrive at the sample without resolvable time information), (2) stroboscopic (pump-probe) mode, and (3) pulsed beam mode for dose rate sensitive materials. In order to analyze the effect of a pulsed beam on image quality, we examined Au nanoparticles using bright field, high-resolution TEM imaging and selected area diffraction in both continuous and pulsed-beam mode. Furthermore, in comparison of conventional TEMs, the add-on beam pulser enables the observation of ultrafast dynamic behavior in materials that are reversible under synchronized excitation.

36 MATERIALS SCIENCE↗

Seeking Augmented Information Content Concerning Diurnal Precipitation Achieved by Combining TRMM-PR and CloudSat-CPR Radar Data Sets

The CloudSat satellite's Cloud Profiling Radar (CPR) is a highly sensitive 94 GHz (W-band) nadir viewing radar system flown in retrograde sun synchronous orbit useful for determining the vertical structure of cloud hydrometeors down to sensitivity of approx. -30 dBZ reflectivity factor. Given this sensitivity, it is possible to unambiguously measure precipitation rates in clouds over a spectrum extending from approx. 0.08 - 3.0 mm hr (sup -1) down to altitudes of 0.5 km with approx.0.25 km vertical binning. This enables an effective means to measure a great deal of the drizzle and light rain spectrum. However, because of its near-polar sunsynchronous orbit, CloudSat cannot sample the diurnal cycle of precipitation, nor with its nadir-only CPR view can it obtain a high duty cycle in sampling precipitation at fixed local times over fixed positions. On the other hand, the TRMM satellite, which is flown in a non-sunsynchronous 35-degree inclined orbit carrying the 13.8 GHz KU-band Precipitation Radar (PR) scanning through nadir over an approx. 225 km swath, can sample both the diurnal cycle and with a much improved duty cycle relative to CloudSat. Moreover, the PR and CPR have the same 0.25 km vertical binning capability. The PR's greatest shortcoming is its approx. +17 dBZ sensitivity, which eliminates the possibility of measuring rain rates below -0.3-0.5 mm hr(sup -1), which can involve rainfall accumulations of up to 50% of the total over some regions. This begs the question of whether by combining CPR and PR data sets, whether it is possible to obtain an augmented measurement of the diurnal precipitation cycle. By collecting complimentary datasets during CloudSat and TRMM satellite orbit crossings within a delta t = 45-min proximity window, it is possible to demonstrate that whenever TRMM detects a precipitation signal, the correlations along the vertical axis between the reflectivities acquired from the CPR and PR are in inverse proportion to the magnitude of the delta t proximity window. By taking advantage of these underlying correlations, it is possible to develop a functional which can be used to broaden the reflectivity spectrum, concomitantly the rain rate spectrum, of the PR measurements based on the inherently broader reflectivity spectrum of the CPR at the lower reflectivity end of the spectrum, concomitantly at lighter rain rates. With the functional in place, it is then possible to produce synthetic CloudSat precipitation imagery over the PR track and thus over the diurnal time period. These augmented data are then used to study the spectral-vertical diurnal properties of precipitation over oceanic regions observed by TRMM.

Smith, Eric A.↗

High-Speed, Multi-Channel Serial ADC LVDS Interface for Xilinx Virtex-5 FPGA

Analog-to-digital converters (ADCs) are used in scientific and communications instruments on all spacecraft. As data rates get higher, and as the transition is made from parallel ADC designs to high-speed, serial, low-voltage differential signaling (LVDS) designs, the need will arise to interface these in field programmable gate arrays (FPGAs). As Xilinx has released the radiation-hardened version of the Virtex-5, this will likely be used in future missions. High-speed serial ADCs send data at very high rates. A de-serializer instantiated in the fabric of the FPGA could not keep up with these high data rates. The Virtex-5 contains primitives designed specifically for high-speed, source-synchronous de-serialization, but as supported by Xilinx, can only support bitwidths of 10. Supporting bit-widths of 12 or more requires the use of the primitives in an undocumented configuration, a non-trivial task. A new SystemVerilog design was written that is simpler and uses fewer hardware resources than the reference design described in Xilinx Application Note XAPP866. It has been shown to work in a Xilinx XC5VSX24OT connected to a MAXIM MAX1438 12-bit ADC using a 50-MHz sample clock. The design can be replicated in the FPGA for multiple ADCs (four instantiations were used for a total of 28 channels).

Taylor, Gregory H.↗

Effective sampling-driven performance tools for GPU-accelerated supercomputers, In: SC '13 Proceedings of the International Conference on High Performance Computing, Networking, Storage and Analysis

Performance analysis of GPU-accelerated systems requires a system-wide view that considers both CPU and GPU components. In this paper, we describe how to extend system-wide, sampling-based performance analysis methods to GPU-accelerated systems. Since current GPUs do not support sampling, our implementation required careful coordination of instrumentation-based performance data collection on GPUs with sampling-based methods employed on CPUs. In addition, we also introduce a novel technique for analyzing systemic idleness in CPU/GPU systems. We demonstrate the effectiveness of our techniques with application case studies on Titan and Keeneland. Some of the highlights of our case studies are: 1) we improved performance for LULESH 1.0 by 30%, 2) we identified a hardware performance problem on Keeneland, 3) we identified a scaling problem in LAMMPS derived from CUDA initialization, and 4) we identified a performance problem that is caused by GPU synchronization operations that suffer delays due to blocking system calls.

Computer Science↗

Engineering experimental program on the effects of near-space radiation on lithium doped solar cells

The results of an experimental evaluation of the real-time degradation characteristics of lithium-diffused silicon solar cells are reported. A strontium-90 radioisotope was used for simulation of a typical earth-orbital electron environment. The experiment was performed in an ion pump vacuum chamber with samples maintained at -50, +20, +50, and +80 C. Samples were illuminated during the 6-month exposure run with solar cell 1-5 characteristics measured periodically in situ. This 6-month exposure corresponded to a 1 MeV equivalent fluence of approximately 10 to the 14th power electrons/sq cm. Several types of lithium cells were irradiatied and compared directly with conventional N/P cells. The best lithium cells compared favorably with N/P cells, particularly at the higher test temperatures. With a slight improvement of initial performance characteristics, lithium cells appear feasible for 5 to 10 year missions at synchronous altitude. Based on the reported results and those of other irradiation experiments, lithium cells would appear to be superior to N/P cells in proton-dominated earth-orbital environments. Another important conclusion of the effort was that illuminated/loaded cells degrade more rapidly than do dark/unloaded cells. The irradiation experiment provided data of high quality with a high degree of confidence because of the experimental and statistical analysis techniques utilized.

Source record↗

U–Pb Geochronology and Stable Isotope Geochemistry of Terrestrial Carbonates, Lower Cretaceous Cedar Mountain Formation, Utah: Implications for Synchronicity of Terrestrial and Marine Carbon Isotope Excursions

The terrestrial Lower Cretaceous Cedar Mountain Formation, Utah, is a critical archive of paleoclimate, tectonics, and vertebrate ecology and evolution. Early Cretaceous carbon cycle perturbations associated with ocean anoxia have been interpreted from this succession, as expressed in stable carbon isotopes. However, refining the timing of the observed stable isotope excursions remains a key challenge in understanding how marine anoxia affects the Earth system, and is ultimately recorded in the terrestrial realm. The geochronology and geochemistry of a terrestrial carbonate near the base of this succession, which potentially records the Ap7 global carbon isotope excursion, is studied here. Petrographic and geochemical analyses are used to test plausible mechanisms for U incorporation into the calcite lattice in this sample. Using these methods, the hypothesis that the incorporation of U was at or close to the timing of carbonate precipitation is evaluated. U–Pb geochronology of calcite indicates a plausible Early Cretaceous age. However, comparison of the new U–Pb ages of calcite with detrital zircon maximum depositional ages immediately beneath the studied sample indicates a disparity in the apparent sedimentation rates if both types of geochronologic information are interpreted as reflecting the timing of sediment deposition. The totality of data supports an early, and high-temperature, diagenetic timing of U incorporation, with potential for minor leaching of U in subsequent fluid–rock interaction. The most likely mechanism for U transport and immobilization in these samples is hydrothermal fluid–rock interaction. Therefore, the radiometric ages, and corresponding stable isotope composition of U-bearing carbonate domains in this sample, indicate early subsurface fluid–rock interactions and not a record of atmosphere–soil geochemical reactions.

36 MATERIALS SCIENCE↗

High repetition rate laser produced soft x-ray source for ultrafast x-ray absorption near edge structure measurements

Recent progress in high intensity ultrafast laser systems provides the opportunity to produce laser plasma x-ray sources exhibiting broad spectrum and high average x-ray flux that are well adapted to x-ray absorption measurements. In this paper, the development of a laser based x-ray absorption near edge structure (XANES) beamline exhibiting high repetition rate by using the Advanced Laser Light Source (ALLS) facility 100 Hz laser system (100 mJ, 35 fs at 800 nm) is presented. This system is based on a broadband tantalum solid target soft x-ray source and a grazing incidence grating spectrometer in the 1-5 nm wavelength range. To demonstrate the high potential of this laser based XANES technique in condensed matter physics, material science, or biology, measurements realized with several samples are presented: VO{sub 2} vanadium L edge, Si{sub 3}N{sub 4} nitrogen K edge, and BPDA/PPD polyimide carbon K edge. The characteristics of this laser based beamline are discussed in terms of brightness, signal to noise ratio, and compared to conventional synchrotron broadband x-ray sources which allow achieving similar measurements. Apart from the very compact size and the relative low cost, the main advantages of such a laser based soft x-ray source are the picosecond pulse duration and the perfect synchronization between this x-ray probe and a laser pulse excitation which open the way to the realization of time resolved x-ray absorption measurements with picosecond range time resolution to study the dynamics of ultrafast processes and phase transition.

36 MATERIALS SCIENCE↗

Clinically relevant concentrations of di (2-ethylhexyl) phthalate (DEHP) uncouple cardiac syncytium

Di(2-ethylhexyl) phthalate (DEHP) is a widely used plasticizer found in a variety of polyvinyl chloride (PVC) medical products. The results of studies in experimental animals suggest that DEHP leached from flexible PVC tubing may cause health problems in some patient populations. While the cancerogenic and reproductive effects of DEHP are well recognized, little is known about the potential adverse impact of phthalates on the heart. This study examined the effects of clinically relevant concentrations of DEHP on neonatal rat cardiomyocytes. It was found that application of DEHP to a confluent, synchronously beating cardiac cell network, leads to a marked, concentration-dependent decrease in conduction velocity and asynchronous cell beating. The mechanism behind these changes was a loss of gap junctional connexin-43, documented using Western blot analysis, dye-transfer assay and immunofluorescence. In addition to its effect on electrical coupling, DEHP treatment also affected the mechanical movement of myocyte layers. The latter was linked to the decreased stiffness of the underlying fibroblasts, as the amount of triton-insoluble vimentin was significantly decreased in DEHP-treated samples. The data indicate that DEHP, in clinically relevant concentrations, can impair the electrical and mechanical behavior of a cardiac cell network. Applicability of these findings to human patients remains to be established.

60 APPLIED LIFE SCIENCES↗

Economic consequences of improved temperature forecasts: An experiment with the Florida citrus growers (control group results)

A demonstration experiment is being planned to show that frost and freeze prediction improvements are possible utilizing timely Synchronous Meteorological Satellite temperature measurements and that this information can affect Florida citrus grower operations and decisions. An economic experiment was carried out which will monitor citrus growers' decisions, actions, costs and losses, and meteorological forecasts and actual weather events and will establish the economic benefits of improved temperature forecasts. A summary is given of the economic experiment, the results obtained to date, and the work which still remains to be done. Specifically, the experiment design is described in detail as are the developed data collection methodology and procedures, sampling plan, data reduction techniques, cost and loss models, establishment of frost severity measures, data obtained from citrus growers, National Weather Service, and Federal Crop Insurance Corp., resulting protection costs and crop losses for the control group sample, extrapolation of results of control group to the Florida citrus industry and the method for normalization of these results to a normal or average frost season so that results may be compared with anticipated similar results from test group measurements.

Source record↗

What we Hope to Learn about Global Mineral Dust Aerosols from EOS Multi-Angle Imaging SpectroRadiometer (MISR)

On global scales, just a few broad atmospheric aerosol compositional groups are commonly observed. Of these, "mineral dust" is the only group which both contains non-spherical particles, and typically has size distributions with enough large particles for particle shape to affect its visible-light-scattering properties. The MISR instrument is scheduled for launch into a 10:30 AM sun-synchronous, polar orbit aboard the EOS Terra satellite in 1999. MISR will measure the upwelling visible radiance from Earth in 4 spectral bands centered at 446, 558, 672, and 866 nm, at each of 9 emission angles spread out in the forward and aft directions along the flight path at +/-70.5 deg, +/-60.0 deg, +/-45.6 deg, +/-26.1deg, and nadir. Over a period of 7 minutes, as the spacecraft flies along, a 360 km wide swath of Earth will successively be viewed by each of the cameras, allowing MISR to sample a very large range of scattering angles; in mid latitudes, the instrument will observe scattering angles between about 60 deg and 160 deg. Global coverage will be acquired about once in 9 days at the equator; the nominal mission lifetime is 6 years. The distinction in single scattering phase function between natural distributions of spherical and randomly oriented, non-spherical particles, with a broad range of aspect ratios, shows up strongly for scattering angles ranging from about 90 deg to near 180 deg. For non-spherical particle distributions, single scattering phase functions tend to be much flatter in this region than for spherical particles. Since MISR samples the relevant range of scattering angles very well, we expect to be able to make critical distinctions between natural distributions of spherical and randomly oriented, non-spherical particles with MISR data. We anticipate that the new multiangle, multispectral data from MISR will also contain other information about particle properties, a major step beyond current spacecraft remote sensing retrievals, which obtain aerosol optical depth based on entirely assumed particle microphysical properties. According to simulations over cloud-free, calm ocean, for pure particles with natural ranges of optical depth, particle size, and indices of refraction, MISR should retrieve column optical depth for all but the darkest particles, to an uncertainty of at most 0.05 or 20%, whichever is larger, even if the particle properties are poorly known. For one common particle type, soot, constraints on the optical depth over dark ocean are very poor. The simulated measurements also should allow us to separate two to four compositional groups based on indices of refraction, and to identify three to four distinct size groups between 0.1 and 2.0 microns characteristic radius at most latitudes. The technique is most sensitive to particle microphysical properties in the "accumulation mode" sizes. where particle scattering undergoes the transition from Rayleigh to large-particle regimes for the MISR wavelengths. Based on these results, we expect to distinguish air masses containing different aerosol types, routinely and globally, with multiangle remote sensing data. Such data complements in situ and field data, which can provide details about aerosol size and composition locally that are needed to assess the radiative effects of aerosols quantitatively. Both field data and correlations in space and time with likely source and sink regions will also be helpful in developing a global picture of mineral dust aerosol budgets. Further work on the expected sensitivity of MISR to natural mixtures of pure particles, including climatologically likely mineral dust components, is currently underway.

Kahn, Ralph↗

Lightning Instrumentation System

A new comprehensive lightning instrumentation system has been designed for the Mobile Launcher 1 (ML-1) at the Kennedy Space Center, Florida. This new instrumentation system includes the synchronized recording of three B-dot, 3-axis measurement stations, one D-dot sensor and eighteen vehicle measurement channels. Each vehicle measurement channel is comprised of two currents and one voltage measurements. The instrumentation system is composed of centralized transient recorders and digitizers, connected to the transient recorders via fiber optic cables. The transient recorders are triggered by the B-dot or D-dot sensors. When the Space Launch System (SLS) vehicle is present at the ML-1, the transient recorders record data on a dual sampling rate mode, continuous slow 5 kilo-samples per second (per channel) and event driven fast 100 mega-samples per second (per channel). Without the presence of the vehicle at the ML-1, the instrumentation system operates only as an event driven fast 100 mega-samples per second (per channel). In the absence of the vehicle, the only measurements recorded are the B-dot and D-dot stations. Additionally, a portable Lightning Monitoring System (LMS) is temporarily installed inside the Orion Crew Capsule module monitoring one portable B-dot, 3-axis measurement station, and 2 Crew Capsule BUS voltages. The portable LMS has a transient recorder independent of the ML-1 transient recorders, that is triggered by the portable B-dot sensor or transients on the vehicle BUS voltages. This portable instrumentation is removed while performing close out operations before the vehicle launch. For the ML-1 lightning instrumentation system, new custom B-dot and D-dot sensors were designed and prototypes were tested at the International Center for Lightning Research and Testing (ICLRT) at Camp Blanding, Florida. The Ground Special Power (GSP) vehicle measurement channels monitoring on the ML-1 is done via 1) Commercial off-the-shelf (COTS) current shunts and 2) custom Voltage Dividers. The new ML-1 lightning instrumentation system was designed, fabricated, deployed, and tested prior to the summer of 2019, in preparation for the first NASA's SLS mission to be launched from the Launch Complex 39B (LC-39B). The ML-1 lightning instrumentation was designed to complement the LC-39B lightning instrumentation system providing electromagnetic measurements closer to the vehicle, at different heights and inside the Crew capsule module.

Angel G Mata↗

Equatorial Annual Oscillation with QBO-driven 5-year Modulation in NCEP Data

An analysis is presented of the zonal wind and temperature variations supplied by the National Center for Environmental Prediction (NCEP), which have been assimilated in the Reanalysis and the Climate Prediction Center (CCP) data sets. The derived zonal-mean variations are employed. Stimulated by modeling studies, the data are separated into the hemispherically symmetric and anti-symmetric components, and spectral analysis is applied to study the annual 12-month oscillation and Quasi-biennial Oscillation (QBO). For data samples that cover as much as 40 years, the results reveal a pronounced 5-year modulation of the symmetric AO in the lower stratosphere, which is confined to equatorial latitudes. This modulation is also inferred for the temperature variations but extends to high latitudes, qualitatively consistent with published model results. A comparison between different data samples indicates that the signature of the 5-year oscillation is larger when the QBO of 30 months is more pronounced. Thus there is circumstantial evidence that this periodicity of the QBO is involved in generating the oscillation. The spectral analysis shows that there is a weak anti-symmetric 5-year oscillation in the zonal winds, which could interact with the large antisymmetric A0 to produce the modulation of the symmetric AO as was shown in earlier modeling studies. According to these studies, the 30-month QBO tends to be synchronized by the equatorial Semi-annual Oscillation (SAO), and this would explain why the inferred 5-year modulation is observed to persist and is phase locked over several cycles.

Mayr, H. G.↗

Metal Hydride Compression

Conventional hydrogen compressors often contribute over half of the cost of hydrogen stations, have poor reliability, and have insufficient flow rates for a mature FCEV market. Fatigue associated with their moving parts including cracking of diaphragms and failure of seal leads to failure in conventional compressors, which is exacerbated by the repeated starts and stops expected at fueling stations. Furthermore, the conventional lubrication of these compressors with oil is generally unacceptable at fueling stations due to potential fuel contamination. Metal hydride (MH) technology offers a very good alternative to both conventional (mechanical) and newly developed (electrochemical, ionic liquid pistons) methods of hydrogen compression. Advantages of MH compression include simplicity in design and operation, absence of moving parts, compactness, safety and reliability, and the possibility to utilize waste industrial heat to power the compressor. Beyond conventional H2 supplies of pipelines or tanker trucks, another attractive scenario is the on-site generating, pressuring and delivering pure H 2 at pressure (≥ 875 bar) for refueling vehicles at electrolysis, wind, or solar generating production facilities in distributed locations that are too remote or widely distributed for cost effective bulk transport. MH hydrogen compression utilizes a reversible heat-driven interaction of a hydride-forming metal alloy with hydrogen gas to form the MH phase and is a promising process for hydrogen energy applications [1,2]. To deliver hydrogen continuously, each stage of the compressor must consist of multiple MH beds with synchronized hydrogenation & dehydrogenation cycles. Multistage pressurization allows achievement of greater compression ratios using reduced temperature swings compared to single stage compressors. The objectives of this project are to investigate and demonstrate on a laboratory scale a two-stage MH hydrogen (H 2 ) gas compressor with a feed pressure of >50 bar and a delivery pressure ≥ 875 bar of high purity H 2 gas using the scheme shown in Figure 1. Progress to date includes the selection of two candidate metal hydrides for each compressor stage, supplier engagement and synthesis of small samples, and the beginning of in-depth characterization of their thermodynamics, kinetics, and hydrogen capacities for optimal performance with respect to energy requirements and efficiency. Additionally, bed design trade studies are underway and will be finalized in FY18. Subsequently, the prototype two-stage compressor will be fabricated, assembled and experimentally evaluated in FY19.

08 HYDROGEN↗

A sampling procedure to guide the collection of narrow-band, high-resolution spatially and spectrally representative reflectance data

A multistage sampling procedure using image processing, geographical information systems, and analytical photogrammetry is presented which can be used to guide the collection of representative, high-resolution spectra and discrete reflectance targets for future satellite sensors. The procedure is general and can be adapted to characterize areas as small as minor watersheds and as large as multistate regions. Beginning with a user-determined study area, successive reductions in size and spectral variation are performed using image analysis techniques on data from the Multispectral Scanner, orbital and simulated Thematic Mapper, low altitude photography synchronized with the simulator, and associated digital data. An integrated image-based geographical information system supports processing requirements.

Brand, R. R.↗

Influence of Temperature on Sr{sub 0.35}La{sub 0.40}Ca{sub .25}Fe{sub 11.6}Co{sub 0.4}O{sub 19} Hexagonal Ferrites Against Structural, Morphological and Magnetic Properties Prepared by Conventional Ceramic Reaction Methodology

Conventional Ceramic Reaction Methodology has been utilized for the preparation of M-type hexagonal ferrites of Sr{sub 0.35}La{sub 0.40}Ca{sub 0.25}Fe{sub 11.6}Co{sub 0.4}O{sub 19} magnets. X-ray diffraction has been performed for phase determination of the magnetic powders. At calcination temperatures ranging from 1220 to 1330 {sup ∘}C, the synchronize compost of the magnetic powders comprised of M-type hexagonal ferrites together with a small amount of impurity phase such as α-Fe{sub 2}O{sub 3} were co-existed. At calcination temperature above 1270 {sup ∘}C, single-phase M-type hexaferrites can be obtained. The particles seemed to be in a hexagonal plate-like mould which spread-out homogeneously were examined by field emission scanning electron microscopy. The magnetic edibility of the magnetic powders was intended by permanent magnetic measurement test equipment vibrating sample magnetometer. Magnetic properties, such as specific saturation magnetization, coercivity and remanence were temperature-dependent. However, with the increase of sintering temperature, i.e. above 1270 {sup ∘}C, saturation magnetization was increased while the coercivity showed reversed order.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Phase error statistics of a phase-locked loop synchronized direct detection optical PPM communication system

Receiver timing synchronization of an optical Pulse-Position Modulation (PPM) communication system can be achieved using a phased-locked loop (PLL), provided the photodetector output is suitably processed. The magnitude of the PLL phase error is a good indicator of the timing error at the receiver decoder. The statistics of the phase error are investigated while varying several key system parameters such as PPM order, signal and background strengths, and PPL bandwidth. A practical optical communication system utilizing a laser diode transmitter and an avalanche photodiode in the receiver is described, and the sampled phase error data are presented. A linear regression analysis is applied to the data to obtain estimates of the relational constants involving the phase error variance and incident signal power.

Natarajan, Suresh↗