Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “surrogate”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Jet fuel ignition delay times: Shock tube experiments over wide conditions and surrogate model predictions

Ignition delay times were measured for gas-phase jet fuel (Jet-A and JP-8) in air behind reflected shock waves in a heated high-pressure shock tube. Initial reflected shock conditions were as follows: temperatures of 715-1229 K, pressures of 17-51 atm, equivalence ratios of 0.5 and 1, and oxygen concentrations of 10 and 21% in synthetic air. Ignition delay times were measured using sidewall pressure and OH* emission at 306 nm. Longer ignition delay times at low temperatures (715-850 K) were accessed by utilizing driver-gas tailoring methods. Also presented is a review of previous ignition delay time measurements of kerosene-based fuels and recent work on surrogate fuel and kinetic mechanism development. To our knowledge, we report the first gas-phase shock tube ignition delay time data for JP-8, and our measurements for Jet-A are for a broader range of conditions than previously available. Our results have very low scatter and are in excellent agreement with the limited previous shock tube data for Jet-A. Although JP-8 and Jet-A have slightly different compositions, their ignition delay times are very similar. A simple 1/P dependence was found for ignition delay times from 874 to 1220 K for the pressure range studied for both fuels. Ignition delay time variations with equivalence ratio and oxygen concentration were also investigated. The new experimental results were compared with predictions of several kinetic mechanisms, using different jet fuel surrogate mixtures. (author)

02 PETROLEUM↗

Detailed chemical kinetic oxidation mechanism for a biodiesel surrogate

A detailed chemical kinetic mechanism has been developed and used to study the oxidation of methyl decanoate, a surrogate for biodiesel fuels. This model has been built by following the rules established by Curran and co-workers for the oxidation of n-heptane and it includes all the reactions known to be pertinent to both low and high temperatures. Computed results have been compared with methyl decanoate experiments in an engine and oxidation of rapeseed oil methyl esters in a jet-stirred reactor. An important feature of this mechanism is its ability to reproduce the early formation of carbon dioxide that is unique to biofuels and due to the presence of the ester group in the reactant. The model also predicts ignition delay times and OH profiles very close to observed values in shock tube experiments fueled by n-decane. These model capabilities indicate that large n-alkanes can be good surrogates for large methyl esters and biodiesel fuels to predict overall reactivity, but some kinetic details, including early CO{sub 2} production from biodiesel fuels, can be predicted only by a detailed kinetic mechanism for a true methyl ester fuel. The present methyl decanoate mechanism provides a realistic kinetic tool for simulation of biodiesel fuels. (author)

09 BIOMASS FUELS↗

Experimental and modeling studies of a biofuel surrogate compound: laminar burning velocities and jet-stirred reactor measurements of anisole

Lignocellulosic biomass is a promising alternative fuel source which can promote energy security, reduce greenhouse gas emissions, and minimize fuel consumption when paired with advanced combustion strategies. Pyrolysis is used to convert lignocellulosic biomass into a complex mixture of phenolic-rich species that can be used in a transportation fuel. Anisole (or methoxybenzene) can be used as a surrogate to represent these phenolic-rich species. Anisole also has attractive properties as a fuel component for use in advanced spark-ignition engines because of its high blending research octane number of 120. Presented in the current work are new measurements of laminar burning velocities, jet-stirred reactor (JSR) speciation of anisole/O 2 /N 2 mixtures, and the development and validation of a detailed chemical kinetic mechanism for anisole. Homogeneous, steady state, fixed gas temperature, perfectly stirred reactor CHEMKIN simulations were used to validate the mechanism against the current JSR measurements and published JSR experiments from CNRS-Nancy. Pyrolysis and oxidation simulations were based on the experimental reactant compositions and thermodynamic state conditions including P = 1 bar and T = 675–1275 K. The oxidation compositions studied in this work span fuel-lean (φ = 0.5), stoichiometric, and fuel rich (φ = 2.0) equivalence ratios. Laminar burning velocities were measured on a heat flux stabilized burner at an unburnt T = 358 K, P = 1 bar and simulated using the CHEMKIN premixed laminar flame speed module. Ignition delay times of anisole were then simulated at conditions relevant to advanced combustion strategies. Current laminar burning velocity measurements and predicted ignition delay times were compared to gasoline components (e.g., n-heptane, iso-octane, and toluene) and gasoline surrogates to highlight differences and similarities in behavior. Reaction path analysis and sensitivity analysis were used to explain the pathways relevant to the current studies. Under pyrolysis and oxidative conditions, unimolecular decomposition of anisole to phenoxy radicals and methyl radicals was found to be important due to the relatively low bond strength between the oxygen and methyl group, ~65 kcal/mol. Finally, reactions of these abundant phenoxy radicals with O 2 were found to be critical to accurately reproduce anisole's reactivity.

10 SYNTHETIC FUELS↗

Autoignition of trans -decalin, a diesel surrogate compound: Rapid compression machine experiments and chemical kinetic modeling

Decahydronaphthalene (decalin), with both cis and trans isomers, is a bicyclic alkane that is found in aviation fuels, diesel fuels, and alternative fuels from tar sands and oil shales. Between the two decalin isomers, trans-decalin has a lower cetane number, is energetically more stable, and has a lower boiling point. Moreover, trans-decalin has often been chosen as a surrogate component to represent two-ring naphthenes in transportation fuels. Recognizing the importance of understanding the chemical kinetics of trans-decalin in the development of surrogate models, an experimental and modeling study has been conducted. Experimentally, the autoignition characteristics of trans-decalin were investigated using a rapid compression machine (RCM) by using trans-decalin/O2/N2 mixtures at compressed pressures of PC=10–25 bar, low-to-intermediate compressed temperatures of TC=620–895 K, and varying equivalence ratios of Φ=0.5, 1.0, and 2.0. These new experimental data demonstrate the effects of pressure, fuel loading, and oxygen concentration on autoignition of trans-decalin. The current RCM data of trans-decalin at lower temperatures were also found to complement well with the literature shock tube data of decalin (mixture of cis+trans) at higher temperatures. Furthermore, a chemical kinetic model for the oxidation of trans-decalin has been developed with new reaction rates and pathways, including, for the first time, a fully-detailed representation of low-temperature chemical kinetics for transdecalin. This model shows good agreement with the overall ignition delay results of the current RCM experiments and the literature shock tube studies. Chemical kinetic analyses of the developed model were further conducted to help identify the fuel decomposition pathways and the reactions controlling the autoignition at varying conditions.

10 SYNTHETIC FUELS↗

PAH formation from jet stirred reactor pyrolysis of gasoline surrogates

Soot particles and their precursor polycyclic aromatic hydrocarbon (PAH) species, formed during combustion, are responsible for particulate emissions in gasoline direct injection (GDI) engines. To better understand the effects of fuel composition on formation of soot in GDI engines, the pyrolysis of several gasoline surrogates was studied in a jet-stirred reactor across a broad temperature range at atmospheric pressure and 1 s residence time. Fuel and intermediate species, including aromatics up to naphthalene, were measured using gas chromatography (GC). PAH concentrations from pyrolysis of surrogate fuels were compared to gain insight into the effects of fuel composition on PAH formation. In addition, synergistic effects were observed in pyrolysis experiments of binary blends. A detailed kinetic model, recently developed at Lawrence Livermore National Laboratory (LLNL), successfully captured the effects of blending and the concentration of major PAHs. Major reaction pathways are discussed, as well as the role of important intermediate species, such as acetylene, and resonantly stabilized radicals such as allyl, propargyl, cyclopentadienyl, and benzyl in the formation of PAH.

36 MATERIALS SCIENCE↗

Characterization of Pancreatic Tumor Motion Using Cine MRI: Surrogates for Tumor Position Should Be Used With Caution

Purpose: Our current understanding of intrafraction pancreatic tumor motion due to respiration is limited. In this study, we characterized pancreatic tumor motion and evaluated the application of several radiotherapy motion management strategies. Methods and Materials: Seventeen patients with unresectable pancreatic cancer were enrolled in a prospective internal review board-approved study and imaged during shallow free-breathing using cine MRI on a 3T scanner. Tumor borders were agreed on by a radiation oncologist and an abdominal MRI radiologist. Tumor motion and correlation with the potential surrogates of the diaphragm and abdominal wall were assessed. These data were also used to evaluate planning target volume margin construction, respiratory gating, and four-dimensional treatment planning for pancreatic tumors. Results: Tumor borders moved much more than expected. To provide 99% geometric coverage, margins of 20 mm inferiorly, 10 mm anteriorly, 7 mm superiorly, and 4 mm posteriorly are required. Tumor position correlated poorly with diaphragm and abdominal wall position, with patient-level Pearson correlation coefficients of -0.18-0.43. Sensitivity and specificity of gating with these surrogates was also poor, at 53%-68%, with overall error of 35%-38%, suggesting that the tumor may be underdosed and normal tissues overdosed. Conclusions: Motion of pancreatic tumor borders is highly variable between patients and larger than expected. There is substantial deformation with breathing, and tumor border position does not correlate well with abdominal wall or diaphragmatic position. Current motion management strategies may not account fully for tumor motion and should be used with caution.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Image-Guided Radiotherapy for Breast Cancer Patients: Surgical Clips as Surrogate for Breast Excision Cavity

Purpose: To determine the use of surgical clips as a surrogate for localization of the excision cavity and to quantify the stability of the clips' positions during the course of external beam radiotherapy for breast cancer patients, using cone beam computed tomography (CBCT) scans. Methods and Materials: Twenty-one breast cancer patients with surgical clips placed in the breast excision cavity were treated in a supine position with 28 daily fractions. CBCT scans were regularly acquired for a setup correction protocol. Retrospectively, the CBCT scans were registered to the planning CT scans, using gray-value registration of the excision cavity region and chamfer matching of the clips. Subsequently, residual setup errors (systematic [{Sigma}] and random [{sigma}]) of the excision cavity were estimated relative to the clips' registration. Finally, the stability of the clips' positions were quantified as the movement of each separate clip according to the center of gravity of the excision cavity. Results: When clips were used for online setup corrections, the residual errors of the excision cavity were {Sigma}{sub left-right} = 1.2, {sigma}{sub left-right} = 1.0; {Sigma}{sub cranial-caudal} = 1.3, {sigma}{sub cranial-caudal} = 1.2; and {Sigma}{sub anterior-posterior} = 0.7, {sigma}{sub anterior-posterior} = 0.9 mm. Furthermore, the average distance (over all patients) between the clips and centers of gravity of the excision cavities was 18.8 mm (on the planning CT) and was reduced to 17.4 mm (measured on the last CBCT scan). Conclusion: Clips move in the direction of the center of gravity of the excision cavity, on average, 1.4 mm. The clips are good surrogates for locating the excision cavity and providing small residual errors.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Lipiodol: A Potential Direct Surrogate for Cone-Beam Computed Tomography Image Guidance in Radiotherapy of Liver Tumor

Purpose: To investigate the feasibility of using lipiodol as a direct surrogate for target localization using cone-beam CT (CBCT) image guidance in radiotherapy (RT) of patients with unresectable liver tumors after transarterial chemoembolization. Methods and Materials: Forty-six patients with an unresectable solitary liver tumor were enrolled for RT using active breathing control (ABC) and CBCT image guidance after transarterial chemoembolization. Each patient had pre- and posttreatment CBCT in the first 10 fractions of treatment. Lipiodol retention was evaluated using daily CBCT scans, and volume of lipiodol retention in the liver was calculated and compared between planning CT and post-RT CT. Influence of lipiodol on dosimetry was evaluated by measuring doses using an ion chamber with and without the presence of lipiodol. Margin analysis was performed on the basis of both inter- and intrafractional target localization errors. Results: Twenty-eight patients successfully completed the study. The shape and size of lipiodol retention did not vary substantially during the course of treatment. The mean Dice similarity coefficient for the lipiodol volume in pretreatment CT and that in posttreatment CT was 0.836 (range, 0.817-0.885). The maximum change (ratio of the lipiodol volume in pretreatment CT to that in posttreatment CT) was 1.045. The mean dose changes with the presence of <10 mL lipiodol were -1.44% and 0.13% for 6 MV and 15 MV, respectively. With ABC and online CBCT image guidance, clinical target volume-planning target volume margins were determined to be 2.5 mm in the mediolateral direction, 2.9 mm in the anteroposterior direction, and 4.0 mm in the craniocaudal direction. Conclusions: Lipiodol could be used as a direct surrogate for CBCT image guidance to improve the localization accuracy for RT of liver tumors. Combination of ABC and CBCT image guidance with lipiodol can potentially reduce the clinical target volume-planning target volume margin.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Tumor Tracking Method Based on a Deformable 4D CT Breathing Motion Model Driven by an External Surface Surrogate

Purpose: To develop a tumor tracking method based on a surrogate-driven motion model, which provides noninvasive dynamic localization of extracranial targets for the compensation of respiration-induced intrafraction motion in high-precision radiation therapy. Methods and Materials: The proposed approach is based on a patient-specific breathing motion model, derived a priori from 4-dimensional planning computed tomography (CT) images. Model parameters (respiratory baseline, amplitude, and phase) are retrieved and updated at each treatment fraction according to in-room radiography acquisition and optical surface imaging. The baseline parameter is adapted to the interfraction variations obtained from the daily cone beam (CB) CT scan. The respiratory amplitude and phase are extracted from an external breathing surrogate, estimated from the displacement of the patient thoracoabdominal surface, acquired with a noninvasive surface imaging device. The developed method was tested on a database of 7 lung cancer patients, including the synchronized information on internal and external respiratory motion during a CBCT scan. Results: About 30 seconds of simultaneous acquisition of CBCT and optical surface images were analyzed for each patient. The tumor trajectories identified in CBCT projections were used as reference and compared with the target trajectories estimated from surface displacement with the a priori motion model. The resulting absolute differences between the reference and estimated tumor motion along the 2 image dimensions ranged between 0.7 and 2.4 mm; the measured phase shifts did not exceed 7% of the breathing cycle length. Conclusions: We investigated a tumor tracking method that integrates breathing motion information provided by the 4-dimensional planning CT with surface imaging at the time of treatment, representing an alternative approach to point-based external–internal correlation models. Although an in-room radiograph-based assessment of the reliability of the motion model is envisaged, the developed technique does not involve the estimation and continuous update of correlation parameters, thus requiring a less intense use of invasive imaging.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Limited Role for Biliary Stent as Surrogate Fiducial Marker in Pancreatic Cancer: Stent and Intratumoral Fiducials Compared

Purpose: Because of low soft-tissue contrast of cone beam computed tomography (CBCT), fiducial markers are often used for radiation therapy patient setup verification. For pancreatic cancer patients, biliary stents have been suggested as surrogate fiducials. Using intratumoral fiducials as standard for tumor position, this study aims to quantify the suitability of biliary stents for measuring interfractional and respiratory-induced position variations of pancreatic tumors. Methods and Materials: Eleven pancreatic cancer patients with intratumoral fiducials and a biliary stent were included in this study. Daily CBCT scans (243 in total) were registered with a reference CT scan, based on bony anatomy, on fiducial markers, and on the biliary stent, respectively. We analyzed the differences in tumor position (ie, markers center-of-mass position) among these 3 registrations. In addition, we measured for 9 patients the magnitude of respiratory-induced motion (MM) of the markers and of the stent on 4-dimensional CT (4DCT) and determined the difference between these 2 magnitudes (ΔMM). Results: The stent indicated tumor position better than bony anatomy in 67% of fractions; the absolute difference between the markers and stent registration was >5 mm in 46% of fractions and >10 mm in 20% of fractions. Large PTV margins (superior-inferior direction, >19 mm) would be needed to account for this interfractional position variability. On 4DCT, we found in superior-inferior direction a mean ΔMM of 0.5 mm (range, –2.6 to 4.2 mm). Conclusions: For respiratory-induced motion, the mean ΔMM is small, but for individual patients the absolute difference can be >4 mm. For interfractional position variations, a stent is, on average, a better surrogate fiducial than bony anatomy, but large PTV margins would still be required. Therefore, intratumoral fiducials are recommended for online setup verification for all pancreatic patients scheduled for radiation therapy, including patients with a biliary stent.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A method for stochastic constrained optimization using derivative-free surrogate pattern search and collocation

Recent advances in coupling novel optimization methods to large-scale computing problems have opened the door to tackling a diverse set of physically realistic engineering design problems. A large computational overhead is associated with computing the cost function for most practical problems involving complex physical phenomena. Such problems are also plagued with uncertainties in a diverse set of parameters. We present a novel stochastic derivative-free optimization approach for tackling such problems. Our method extends the previously developed surrogate management framework (SMF) to allow for uncertainties in both simulation parameters and design variables. The stochastic collocation scheme is employed for stochastic variables whereas Kriging based surrogate functions are employed for the cost function. This approach is tested on four numerical optimization problems and is shown to have significant improvement in efficiency over traditional Monte-Carlo schemes. Problems with multiple probabilistic constraints are also discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Low-rank separated representation surrogates of high-dimensional stochastic functions: Application in Bayesian inference

This study introduces a non-intrusive approach in the context of low-rank separated representation to construct a surrogate of high-dimensional stochastic functions, e.g., PDEs/ODEs, in order to decrease the computational cost of Markov Chain Monte Carlo simulations in Bayesian inference. The surrogate model is constructed via a regularized alternative least-square regression with Tikhonov regularization using a roughening matrix computing the gradient of the solution, in conjunction with a perturbation-based error indicator to detect optimal model complexities. The model approximates a vector of a continuous solution at discrete values of a physical variable. The required number of random realizations to achieve a successful approximation linearly depends on the function dimensionality. The computational cost of the model construction is quadratic in the number of random inputs, which potentially tackles the curse of dimensionality in high-dimensional stochastic functions. Furthermore, this vector-valued separated representation-based model, in comparison to the available scalar-valued case, leads to a significant reduction in the cost of approximation by an order of magnitude equal to the vector size. The performance of the method is studied through its application to three numerical examples including a 41-dimensional elliptic PDE and a 21-dimensional cavity flow.

97 MATHEMATICS AND COMPUTING↗

A new surrogate modeling technique combining Kriging and polynomial chaos expansions – Application to uncertainty analysis in computational dosimetry

In numerical dosimetry, the recent advances in high performance computing led to a strong reduction of the required computational time to assess the specific absorption rate (SAR) characterizing the human exposure to electromagnetic waves. However, this procedure remains time-consuming and a single simulation can request several hours. As a consequence, the influence of uncertain input parameters on the SAR cannot be analyzed using crude Monte Carlo simulation. The solution presented here to perform such an analysis is surrogate modeling. This paper proposes a novel approach to build such a surrogate model from a design of experiments. Considering a sparse representation of the polynomial chaos expansions using least-angle regression as a selection algorithm to retain the most influential polynomials, this paper proposes to use the selected polynomials as regression functions for the universal Kriging model. The leave-one-out cross validation is used to select the optimal number of polynomials in the deterministic part of the Kriging model. The proposed approach, called LARS-Kriging-PC modeling, is applied to three benchmark examples and then to a full-scale metamodeling problem involving the exposure of a numerical fetus model to a femtocell device. The performances of the LARS-Kriging-PC are compared to an ordinary Kriging model and to a classical sparse polynomial chaos expansion. The LARS-Kriging-PC appears to have better performances than the two other approaches. A significant accuracy improvement is observed compared to the ordinary Kriging or to the sparse polynomial chaos depending on the studied case. This approach seems to be an optimal solution between the two other classical approaches. A global sensitivity analysis is finally performed on the LARS-Kriging-PC model of the fetus exposure problem.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Adaptive surrogate modeling by ANOVA and sparse polynomial dimensional decomposition for global sensitivity analysis in fluid simulation

The Polynomial Dimensional Decomposition (PDD) is employed in this work for the global sensitivity analysis and uncertainty quantification (UQ) of stochastic systems subject to a moderate to large number of input random variables. Due to the intimate connection between the PDD and the Analysis of Variance (ANOVA) approaches, PDD is able to provide a simpler and more direct evaluation of the Sobol' sensitivity indices, when compared to the Polynomial Chaos expansion (PC). Unfortunately, the number of PDD terms grows exponentially with respect to the size of the input random vector, which makes the computational cost of standard methods unaffordable for real engineering applications. In order to address the problem of the curse of dimensionality, this work proposes essentially variance-based adaptive strategies aiming to build a cheap meta-model (i.e. surrogate model) by employing the sparse PDD approach with its coefficients computed by regression. Three levels of adaptivity are carried out in this paper: 1) the truncated dimensionality for ANOVA component functions, 2) the active dimension technique especially for second- and higher-order parameter interactions, and 3) the stepwise regression approach designed to retain only the most influential polynomials in the PDD expansion. During this adaptive procedure featuring stepwise regressions, the surrogate model representation keeps containing few terms, so that the cost to resolve repeatedly the linear systems of the least-squares regression problem is negligible. The size of the finally obtained sparse PDD representation is much smaller than the one of the full expansion, since only significant terms are eventually retained. Consequently, a much smaller number of calls to the deterministic model is required to compute the final PDD coefficients.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Surrogate approximation of the Grad–Shafranov free boundary problem via stochastic collocation on sparse grids

In magnetic confinement fusion devices, the equilibrium configuration of a plasma is determined by the balance between the hydrostatic pressure in the fluid and the magnetic forces generated by an array of external coils and the plasma itself. The location of the plasma is not known a priori and must be obtained as the solution to a free boundary problem. The partial differential equation that determines the behavior of the combined magnetic field depends on a set of physical parameters (location of the coils, intensity of the electric currents going through them, magnetic permeability, etc.) that are subject to uncertainty and variability. The confinement region is in turn a function of these stochastic parameters as well. In this work, we consider variations on the current intensities running through the external coils as the dominant source of uncertainty. This leads to a parameter space of dimension equal to the number of coils in the reactor. With the aid of a surrogate function built on a sparse grid in parameter space, a Monte Carlo strategy is used to explore the effect that stochasticity in the parameters has on important features of the plasma boundary such as the location of the x-point, the strike points, and shaping attributes such as triangularity and elongation. Furthermore, the use of the surrogate function reduces the time required for the Monte Carlo simulations by factors that range between 7 and over 30.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

On the influence of over-parameterization in manifold based surrogates and deep neural operators

Constructing accurate and generalizable approximators (surrogate models) for complex physico-chemical processes exhibiting highly non-smooth dynamics is challenging. The main question is what type of surrogate models we should construct and should these models be under-parameterized or over-parameterized. In this work, we propose new developments and perform comparisons for two promising approaches: manifold-based polynomial chaos expansion (m-PCE) and the deep neural operator (DeepONet), and we examine the effect of over-parameterization on generalization. While m-PCE enables the construction of a mapping by first identifying low-dimensional embeddings of the input functions, parameters, and quantities of interest (QoIs), a neural operator learns the nonlinear mapping via the use of deep neural networks. Here, we demonstrate the performance of these methods in terms of generalization accuracy by solving the 2D time-dependent Brusselator reaction-diffusion system with uncertainty sources, modeling an autocatalytic chemical reaction between two species. We first propose an extension of the m-PCE by constructing a mapping between latent spaces formed by two separate embeddings of the input functions and the output QoIs. To further enhance the accuracy of the DeepONet, we introduce weight self-adaptivity in the loss function. We demonstrate that the performance of m-PCE and DeepONet is comparable for cases of relatively smooth input-output mappings. However, when highly non-smooth dynamics is considered, DeepONet shows higher approximation accuracy. We also find that for m-PCE, modest over-parameterization leads to better generalization, both within and outside of distribution, whereas aggressive over-parameterization leads to over-fitting. In contrast, an even highly over-parameterized DeepONet leads to better generalization for both smooth and non-smooth dynamics. Furthermore, we compare the performance of the above models with another recently proposed operator learning model, the Fourier Neural Operator, and show that its over-parameterization also leads to better generalization. Taken together, our studies show that m-PCE can provide very good accuracy at very low training cost, whereas a highly over-parameterized DeepONet can provide better accuracy and robustness to noise but at higher training cost. In both methods, the inference cost is negligible.

97 MATHEMATICS AND COMPUTING↗

Characterizing surrogates to develop an additive manufacturing process for U 3 Si 2 nuclear fuel

U 3 Si 2 is considered as an accident-tolerant nuclear fuel candidate due to its promising high uranium density along with its improved thermal properties. The current U 3 Si 2 powder metallurgical fabrication process encompasses numerous process steps with extensive fabrication times. Thus, an additive manufacturing process to fabricate U 3 Si 2 is currently under development to ultimately produce U 3 Si 2 fuel at a lower cost, in a timely and commercially-reliable manner. The current research work seeks to characterize U 3 Si 2 surrogate materials fabricated by a laser synthesis. The characterization results provided novel microstructural data that aided in the early development stages of an additive manufacturing process. For this study, cerium, zirconium, and hafnium, were selected as surrogates based on their thermodynamic properties and crystal structure. As a result, the laser-synthesized samples were characterized by means of scanning electron microscopy (SEM), energy-dispersive X-ray spectroscopy (EDS) along with X-ray diffraction (XRD), where the different phases of formation, morphology, and microstructural features have been analyzed. Laser synthesis showed suitability for alloying Zr-Si and Hf-Si to ultimately form silicide compounds (Zr 3 Si 2 and Hf 3 Si 2 ).

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Characterization of high thermal conductivity fuel surrogates before and after ion irradiation

High thermal conductivity nuclear fuels offer important potential advantages over traditional oxide-based fuels such as higher burnup, reduction in fission gas release, and better overall safety of the system. One proposed approach to high thermal conductivity fuels utilizes high thermal conductivity nonfissile additives with UO 2 fuel to lower the fuel operating temperature and thereby take advantage of the highly favorable radiation resistance of UO 2 at lower operating temperatures. However, differential swelling in the matrix and high conductivity additive phases during high dose irradiation could lead to internal cracking and poor performance. In the current study, ceria (CeO 2 ) and zirconia (ZrO 2 ) surrogate matrices were used to model UO2 behavior. Additives of 10 vol. % Al 2 O 3 or SiC in the form of short fibers or platelets were used for the high conductivity second phase. The nuclear fuel surrogates were sintered to achieve densities greater than 93% of the ideal values. Scanning electron microscopy (SEM) imaging and X-ray diffraction confirmed the uniform distribution of the second phase and that no intermetallic second phase was formed during sintering. The thermal conductivity of the sintered samples was measured from 50 °C to 900 °C and confirmed the desirable increase compared to pure CeO 2 /ZrO 2 pellets. Samples were irradiated with 20 MeV Ni 6+ ions at midrange doses ranging from 1 to 15 displacements per atom (dpa) and temperatures from 300 °C to 700 °C. Post irradiation characterization revealed a good stability of the samples at low to medium doses with matrix lattice parameter swelling of < 0.14 % but showed a significant microstructural deterioration and decrease of the mechanical properties at 15 dpa.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗