Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “signal Processing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Real-Time Data Display

RT-Display is a MATLAB-based data acquisition environment designed to use a variety of commercial off-the-shelf (COTS) hardware to digitize analog signals to a standard data format usable by other post-acquisition data analysis tools. This software presents the acquired data in real time using a variety of signal-processing algorithms. The acquired data is stored in a standard Operator Interactive Signal Processing Software (OISPS) data-formatted file. RT-Display is primarily configured to use the Agilent VXI (or equivalent) data acquisition boards used in such systems as MIDDAS (Multi-channel Integrated Dynamic Data Acquisition System). The software is generalized and deployable in almost any testing environment, without limitations or proprietary configuration for a specific test program or project. With the Agilent hardware configured and in place, users can start the program and, in one step, immediately begin digitizing multiple channels of data. Once the acquisition is completed, data is converted into a common binary format that also can be translated to specific formats used by external analysis software, such as OISPS and PC-Signal (product of AI Signal Research Inc.). RT-Display at the time of this reporting was certified on Agilent hardware capable of acquisition up to 196,608 samples per second. Data signals are presented to the user on-screen simultaneously for 16 channels. Each channel can be viewed individually, with a maximum capability of 160 signal channels (depending on hardware configuration). Current signal presentations include: time data, fast Fourier transforms (FFT), and power spectral density plots (PSD). Additional processing algorithms can be easily incorporated into this environment.

Pedings, Marc↗

Spectral imaging applications: Remote sensing, environmental monitoring, medicine, military operations, factory automation and manufacturing

This paper reviews the activities at OKSI related to imaging spectroscopy presenting current and future applications of the technology. The authors discuss the development of several systems including hardware, signal processing, data classification algorithms and benchmarking techniques to determine algorithm performance. Signal processing for each application is tailored by incorporating the phenomenology appropriate to the process, into the algorithms. Pixel signatures are classified using techniques such as principal component analyses, generalized eigenvalue analysis and novel very fast neural network methods. The major hyperspectral imaging systems developed at OKSI include the Intelligent Missile Seeker (IMS) demonstration project for real-time target/decoy discrimination, and the Thermal InfraRed Imaging Spectrometer (TIRIS) for detection and tracking of toxic plumes and gases. In addition, systems for applications in medical photodiagnosis, manufacturing technology, and for crop monitoring are also under development.

National Defense↗

Wireless Monitoring of the Height of Condensed Water in Steam Pipes

A wireless health monitoring system has been developed for determining the height of water condensation in the steam pipes and the data acquisition is done remotely using a wireless network system. The developed system is designed to operate in the harsh environment encountered at manholes and the pipe high temperature of over 200 °C. The test method is an ultrasonic pulse-echo and the hardware includes a pulser, receiver and wireless modem for communication. Data acquisition and signal processing software were developed to determine the water height using adaptive signal processing and data communication that can be controlled while the hardware is installed in a manhole. A statistical decision-making tool is being developed based on the field test data to determine the height of in the condensed water under high noise conditions and other environmental factors.

High Temperatures↗

Frequency domain laser velocimeter signal processor

A new scheme for processing signals from laser velocimeter systems is described. The technique utilizes the capabilities of advanced digital electronics to yield a signal processor capable of operating in the frequency domain maximizing the information obtainable from each signal burst. This allows a sophisticated approach to signal detection and processing, with a more accurate measurement of the chirp frequency resulting in an eight-fold increase in measurable signals over the present high-speed burst counter technology. Further, the required signal-to-noise ratio is reduced by a factor of 32, allowing measurements within boundary layers of wind tunnel models. Measurement accuracy is also increased up to a factor of five.

Meyers, James F.↗

Geophysical Monitoring Program Core Seismic Libraries

The Geophysical Monitoring Program Core Seismic Libraries contain a broad array of seismic and waveform analysis libraries useful for a wide range of seismic analysis processes. These include signal processing, travel time calculation, waveform correlation, array processing, geometry and geodesy, and plotting libraries.

Barno, JustinG [Lawrence Livermore National Labora↗

Mesh-connected processor arrays for the transitive closure problem

The main purpose in this paper is to lay a theoretical foundation for the design of mesh-connected processor arrays for the transitive closure problem. Using a simple path-algebraic formulation of the problem and observing its similarity to certain well-known smoothing problems that occur in digital signal processing, it is shown how to draw upon existing techniques from the signal processing literature to derive regular iterative algorithms for determining the transitive closure of the graph. The regular iterative algorithms that are derived using these considerations, are then analyzed and synthesized on mesh-connected processor arrays. Among the vast number of mesh-connected processor arrays that can be designed using this unified approach, the systolic arrays reported in the literature for this problem are shown to be special cases.

Rao, S. K.↗

Shaft-Rotation Detector

Signal-processing subsystem generates signal indicative of rotation of shaft from output of accelerometer mounted on housing of bearing supporting shaft. Output of subsystem binary signal at frequency of rotation of shaft. Part of assembly of electronic equipment measuring vibrations in rotating machinery. Accelerometer mounted in such way sensitive to vibrations of shaft perpendicular to axis. Output of accelerometer includes noise and components of vibration at frequencies higher than rotational frequency of shaft.

Randall, Richard L.↗

Advanced telemetry systems for payloads. Technology needs, objectives and issues

The current trends in advanced payload telemetry are the new developments in advanced modulation/coding, the applications of intelligent techniques, data distribution processing, and advanced signal processing methodologies. Concerted efforts will be required to design ultra-reliable man-rated software to cope with these applications. The intelligence embedded and distributed throughout various segments of the telemetry system will need to be overridden by an operator in case of life-threatening situations, making it a real-time integration issue. Suitable MIL standards on physical interfaces and protocols will be adopted to suit the payload telemetry system. New technologies and techniques will be developed for fast retrieval of mass data. Currently, these technology issues are being addressed to provide more efficient, reliable, and reconfigurable systems. There is a need, however, to change the operation culture. The current role of NASA as a leader in developing all the new innovative hardware should be altered to save both time and money. We should use all the available hardware/software developed by the industry and use the existing standards rather than inventing our own.

Source record↗

A Low Cost Single Chip VDL Compatible Transceiver ASIC

Recent trends in commercial communications system components have focussed almost exclusively on cellular telephone technology. As many of the traditional sources of receiver components have discontinued non-cellular telephone products, the designers of avionics and other low volume radio applications find themselves increasingly unable to find highly integrated components. This is particularly true for low power, low cost applications which cannot afford the lavish current consumption of the software defined radio approach increasingly taken by certified device manufacturers. In this paper, we describe a low power transceiver chip targeting applications from low VHF to low UHF frequencies typical of avionics systems. The chip encompasses a selectable single or double conversion design for the receiver and a low power IF upconversion transmitter. All local oscillators are synthesized and integrated into the chip. An on-chip I-Q modulator and demodulator provide baseband modulation and demodulation capability allowing the use of low power, fixed point signal processing components for signal demodulation. The goal of this program is to demonstrate a low cost VDL mode-3 transceiver using this chip to receive text weather information sent using 4-slot TDMA with no support for voice. The data will be sent from an experimental ground station. This work is funded by NASA Glenn Research Center.

Becker, Robert↗

Communicating by Doppler: Detecting Spacecraft Dynamics During Critical Maneuvers

Communicating information from spacecraft in deep space utilizes sophisticated techniques of modulations onto a microwave signal carrier. Under most conditions, there is a high success rate of sending commands to the spacecraft and receiving science data acquired by on-board instruments along with health and status information. There are conditions, however, where the signal dynamics are too high and/or the received signal-to-noise ratio is below the receiver threshold. Under these conditions, often by design and sometimes as a result of planned or unplanned critical maneuvers, events (e.g., orbit insertion or descent and landing), safe mode, etc., it becomes highly critical but exceedingly challenging to receive information about the health and dynamical behavior of the spacecraft. The Deep Space Network, being a world-class instrument for Radio Science research, developed openloop receivers, called the Radio Science Receiver, designed to capture the raw incoming electromagnetic signals and associated noise for Radio Science experiments; post data capture digital signal processing extracts the signal carrier for scientific analysis. This receiver provides a high level of configuration flexibility and can be optimized for the various types of experiments. In addition to its scientific utility, it proved to be useful, and in some cases critical, for the support of missions during specific scenarios were the link budget is below the threshold of the tracking receiver to maintain lock or the frequency dynamics are faster than the limits of the tracking receiver. In these cases, the signal carrier is often detected only in the open-loop receiver to provide information on the specific behavior of the spacecraft from the carrier dynamics. This paper describes the utility of the system to support mission-critical events for the three cases of Cassini's Saturn orbit insertion, Huygens Titan landing, and Mars rovers landing.

radio science↗

Remote Measurement of Atmospheric Temperatures By Raman Lidar

The Raman shifted return of a lidar, or optical radar, system has been utilized to make atmospheric temperature measurements. These measurements were made along a horizontal path at temperatures between -20 C and +30 C and at ranges of about 100 meters. The temperature data were acquired by recording the intensity ratio of two portions of the Raman spectrum which were simultaneously sampled from a preset range. The lidar unit employed in this testing consisted of a 4 joule-10ppm laser operating at 694.3 nm, a 10-inch Schmidt-Cassegrain telescope, and a system of time-gated detection and signal processing electronics. The detection system processed three return signal wavelength intervals - two intervals along the rotational Raman scattered spectrum and one interval centered at the Rayleigh-Mie scattered wavelength. The wavelength intervals were resolved by using a pellicle beam splitter and three optical interference filters. Raman return samples were taken from one discrete range segment during each test shot and the signal intensities were displayed in digital format. The Rayleigh-Mie techniques. The test site utilized to evaluate this measurement technique encompassed a total path length of 200 meters. Major components of the test site included a trailer-van housing the lidar unit, a controlled environment test zone, and a beam terminator. The control zone which was located about 100 meters from the trailer was 12 meters in length, 2.4 meters in diameter, and was equipped with hinged doors at each end. The temperature of the air inside the zone could be either raised or lowered with respect to ambient air through the use of infrared heaters or a liquid-nitrogen cooling system. Conditions inside the zone were continuously monitored with a thermocouple rake assembly. The test path length was terminated by a 1.2 meter square array of energy absorbing cones and a flat black screen. Tests were initially conducted at strictly ambient conditions utilizing the normal outside air temperatures as a test parameter. These tests provided a calibration of the Raman intensity ratio as a function of' temperature for the particular optical-filter arrangement used in this system while also providing a test of' the theoretical prediction formulated in the design of the system. Later tests utilized zone temperatures above and below ambient to provide temperature gradient data. These tests indicate that ten shots, or one minute of' data acquisition, from a 100 meter range can provide absolute temperature measurements with an accuracy of + 30 C and a range resolution of about 5 meters. Because this measurement accuracy compares well with that predicted for this particular unit, it is suggested that a field-application system could be built with signif'icant improvements in both absolute accuracy and range.

Salzman, Jack A.↗

An overview of data acquisition, signal coding and data analysis techniques for MST radars

An overview is given of the data acquisition, signal processing, and data analysis techniques that are currently in use with high power MST/ST (mesosphere stratosphere troposphere/stratosphere troposphere) radars. This review supplements the works of Rastogi (1983) and Farley (1984) presented at previous MAP workshops. A general description is given of data acquisition and signal processing operations and they are characterized on the basis of their disparate time scales. Then signal coding, a brief description of frequently used codes, and their limitations are discussed, and finally, several aspects of statistical data processing such as signal statistics, power spectrum and autocovariance analysis, outlier removal techniques are discussed.

Rastogi, P. K.↗

Electrical alternans during rest and exercise as predictors of vulnerability to ventricular arrhythmias

This investigation was performed to evaluate the feasibility of detecting repolarization alternans with the heart rate elevated with a bicycle exercise protocol. Sensitive spectral signal-processing techniques are able to detect beat-to-beat alternation of the amplitude of the T wave, which is not visible on standard electrocardiogram. Previous animal and human investigations using atrial or ventricular pacing have demonstrated that T-wave alternans is a marker of vulnerability to ventricular arrhythmias. Using a spectral analysis technique incorporating noise reduction signal-processing software, we evaluated electrical alternans at rest and with the heart rate elevated during a bicycle exercise protocol. In this study we defined optimal criteria for electrical alternans to separate patients from those without inducible arrhythmias. Alternans and signal-averaged electrocardiographic results were compared with the results of vulnerability to ventricular arrhythmias as defined by induction of sustained ventricular tachycardia or fibrillation at electrophysiologic evaluation. In 27 patients alternans recorded at rest and with exercise had a sensitivity of 89%, specificity of 75%, and overall clinical accuracy of 80% (p <0.003). In this patient population the signal-averaged electrocardiogram was not a significant predictor of arrhythmia vulnerability. This is the first study to report that repolarization alternans can be detected with heart rate elevated with a bicycle exercise protocol. Alternans measured using this technique is an accurate predictor of arrhythmia inducibility.

Clinical Trial↗

Input-output characterization of an ultrasonic testing system by digital signal analysis

Ultrasonic test system input-output characteristics were investigated by directly coupling the transmitting and receiving transducers face to face without a test specimen. Some of the fundamentals of digital signal processing were summarized. Input and output signals were digitized by using a digital oscilloscope, and the digitized data were processed in a microcomputer by using digital signal-processing techniques. The continuous-time test system was modeled as a discrete-time, linear, shift-invariant system. In estimating the unit-sample response and frequency response of the discrete-time system, it was necessary to use digital filtering to remove low-amplitude noise, which interfered with deconvolution calculations. A digital bandpass filter constructed with the assistance of a Blackman window and a rectangular time window were used. Approximations of the impulse response and the frequency response of the continuous-time test system were obtained by linearly interpolating the defining points of the unit-sample response and the frequency response of the discrete-time system. The test system behaved as a linear-phase bandpass filter in the frequency range 0.6 to 2.3 MHz. These frequencies were selected in accordance with the criterion that they were 6 dB below the maximum peak of the amplitude of the frequency response. The output of the system to various inputs was predicted and the results were compared with the corresponding measurements on the system.

Williams, J. H., Jr.↗

A multipurpose digital modulator

The theoretical basis and hardware implementation of a versatile device which uses digital signal-processing methods to achieve signal modulation are reported. The carrier-modulation process is formulated as a simple quadrature equation; a generalized description of the signal constellation to be processed is derived; the pulse-shaping scheme is explained; and the system architecture is described in detail and illustrated with diagrams. Experimental results obtained with a breadboard transmitter based on this modulation technique are presented in extensive graphs. The power spectra and eye diagrams generated for different QPSK, 8PSK, and MSK modulation schemes are shown to be in good agreement with theoretical predictions. It is suggested that this modulator could be readily implemented in VLSI and mass produced.

Davarian, Faramaz↗

Radiation sensitive area detection device and method

A radiation sensitive area detection device for use in conjunction with an X ray, ultraviolet or other radiation source is provided which comprises a phosphor containing film which releases a stored diffraction pattern image in response to incoming light or other electromagnetic wave. A light source such as a helium-neon laser, an optical fiber capable of directing light from the laser source onto the phosphor film and also capable of channelling the fluoresced light from the phosphor film to an integrating sphere which directs the light to a signal processing means including a light receiving means such as a photomultiplier tube. The signal processing means allows translation of the fluoresced light in order to detect the original pattern caused by the diffraction of the radiation by the original sample. The optical fiber is retained directly in front of the phosphor screen by a thin metal holder which moves up and down across the phosphor screen and which features a replaceable pinhole which allows easy adjustment of the resolution of the light projected onto the phosphor film. The device produces near real time images with high spatial resolution and without the distortion that accompanies prior art devices employing photomultiplier tubes. A method is also provided for carrying out radiation area detection using the device of the invention.

Carter, Daniel C.↗

Source-Time Dominant Modeling of the Doppler Shift for the Auralization of Moving Sources

When developing an auralization for acoustic scenarios involving moving sources and receivers, one key feature is the ability to simulate the Doppler shift, i.e., the changing frequency content from the receiver’s perspective. As the time-varying delay between a source and receiver is what accounts for the Doppler shift, an approximation of this delay is required to successfully render the changes in frequency content at the receiver. Depending on the signal-processing strategy chosen to accomplish this task, there is, how-ever, a potential to introduce audible artifacts due to frequency folding (aliasing), frequency replication (imaging), and broadband noise. In this paper we dis-cuss the manifestation of such artifacts and propose a method to eliminate them, which can be integrated into the digital signal processing chain of larger auralization schemes. The method is built upon a source-time dominant approach and uses a combination of oversampling, interpolation, and time-varying filtering to predict and eliminate frequency regions at the receiver that are vulnerable to aliasing and imaging. We demonstrate the strengths and weaknesses of the method using a circularly moving source with a fixed receiver.

Auralization↗