Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “sample acquisition”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Oceanographic biooptical profiling system

A new oceanographic instrument to measure underwater optical, biological, and physical properties has been designed, built, and used extensively at sea. The new instrument system is a significant advance that permits optimum sampling strategies using ship, aircraft, and satellite optical sensors for ocean research. The design criteria for the biooptical profiling system included the rapid acquisition of data to accommodate shipboard synoptic sampling; the measurement of the necessary parameters for providing appropriate contemporaneous surface data for remote sensors; the compatibility of the data acquisition system with conventional conductivity temperature depth-type cables and winches on the oceanographic fleet; the capability of real-time display of data along with rapid preliminary data reduction at sea. The primary instrument package in this profiling system is a new microprocessor controlled multiwavelength spectroradiometer. A description of the instrument and examples of data are presented.

Smith, R. C.↗

Curating Nasa's Future Extraterrestrial Sample Collections: the Role of Advanced Curation

The Astromaterials Acquisition and Curation Office at NASA Johnson Space Center (JSC) (henceforth referred to herein as NASA Curation Office) is responsible for curating all of NASA's extraterrestrial samples. Under the governing document, NASA Policy Directive (NPD) 7100.10F "Curation of Extraterrestrial Materials," JSC is charged with "The curation of all extraterrestrial material under NASA control, including future NASA missions." The Directive goes on to define Curation as including "...documentation, preservation, preparation, and distribution of samples for re-search, education, and public outreach." Here we describe some of the ongoing efforts to ensure that the future activities of the NASA Curation Office are working towards a state of maximum proficiency.

McCubbin, Francis M.↗

H I 21 centimeter observations and I-band CCD surface photometry of spiral galaxies behind the Virgo Cluster and toward its antipode

Sample selection, radio and optical data acquisition and reduction, and observation results are presented for spiral galaxies behind the Virgo Cluster and toward its antipode. I-band CCD photometry was obtained for all the bright galaxies and part of the sample of faint galaxies in the two local volumes was studied. The statistical properties of the galaxy samples are discussed.

Lu, N. Y.↗

Model-based frequency response characterization of a digital-image analysis system for epifluorescence microscopy

Consideration is given to a model-based method for estimating the spatial frequency response of a digital-imaging system (e.g., a CCD camera) that is modeled as a linear, shift-invariant image acquisition subsystem that is cascaded with a linear, shift-variant sampling subsystem. The method characterizes the 2D frequency response of the image acquisition subsystem to beyond the Nyquist frequency by accounting explicitly for insufficient sampling and the sample-scene phase. Results for simulated systems and a real CCD-based epifluorescence microscopy system are presented to demonstrate the accuracy of the method.

Hazra, Rajeeb↗

ATS-6 - Preliminary results from the 13/18-GHz COMSAT Propagation Experiment

The 13/18-GHz COMSAT Propagation Experiment (CPE) is reviewed, the data acquisition and processing are discussed, and samples of preliminary results are presented. The need for measurements of both hydrometeor-induced attenuation statistics and diversity effectiveness is brought out. The facilitation of the experiment - CPE dual frequency and diversity site location, the CPE ground transmit terminals, the CPE transponder on Applications Technology Satellite-6 (ATS-6), and the CPE receive and data acquisition system - is briefly examined. The on-line preprocessing of the received signal is reviewed, followed by a discussion of the off-line processing of this database to remove signal fluctuations not due to hydrometeors. Finally, samples of the results of first-level analysis of the resultant data for the 18-GHz diversity site near Boston, Mass., and for the dual frequency 13/18-GHz site near Detroit, Mich., are presented and discussed.

Hyde, G.↗

Astromaterial Curation and Research at NASA

Astromaterial sample return missions from other planetary bodies (e.g., the Moon, asteroids, the Sun) and astromaterial sample collection missions here on Earth (e.g., Antarctic Meteorites, Cosmic Dust) have been a vital part of NASA’s science vision since nearly its inception. Beginning with the Apollo missions to the Moon and extending to the recent successful sample collection by the OSIRIS-REx asteroid sample return mission, these astromaterials collections have been an invaluable resource to scientists and educators around the world. Sample studies continue to provide fundamental insight into how our solar system and its constituent bodies formed and evolved over the past 4.5 billion years. As evidence of their broad impact, there are over 19,141 samples on loan to 433 Principal Investigators in 24 countries [1]. As we plan for exploration missions through 2050, sample return missions will continue to play a vital role in NASA’s science vision. Returned samples truly are the gift that keeps on giving. Having the samples accessible on Earth allows new generations of scientists and new generations of instrumentation to pursue ever evolving scientific questions. For example, the Apollo samples were collected ~50 years ago, yet our views of how the Earth-Moon system formed, the role of volatiles in the early inner solar system, and even the positions of the gas giants in the outer solar system have changed dramatically as a result of Apollo sample analyses conducted very recently. Vital to the long-term viability of any sample return mission is the careful curation of the samples. Curatorial efforts need to begin early in the project lifecycle, not with the return of the samples, but at mission conception. The Astromaterials Acquisition and Curation Office at NASA Johnson Space Center is responsible for curating all of NASA’s current and future extraterrestrial samples. Looking at possible sample return missions over the next 35+ years [2], many samples would require curation efforts a step beyond current capabilities, e.g., cold or cryogenic curation, organically and biologically clean curation, curation of gases and ices, and curation of samples with extreme pressure, temperature, or redox requirements. During the lecture, we discuss the current curatorial efforts in JSC curation, as well as discoveries from the astromaterial research. [1] Zeigler, R. A. et al. (2017) Planetary Science Vision 2050 Workshop. [2] McCubbin F. M. et al. (2017) Planetary Science Vision 2050 Workshop.

astromaterial↗

Sub-Nyquist Distortions in Sampled One- and Two-Dimensional Signals Studied

Hardware testing frequently involves the acquisition of waveform and instrumentation signals, which are often recorded on waveform recorders, oscillographs, and video recorders. Years ago, the waveforms were viewed as analog records, as drawn by a paper strip chart pen or electron beam on a cathode ray tube screen. One of the problems in the past was that the analog electronics may not have been able to accurately display the full amplitude of a signal if the real-time signals exceeded the frequency response bandwidth of the recording device. The advent of digital oscilloscopes, waveform recorders, and video frame-grabbers solved many of the frequency response problems, though not all. A restriction on digital waveform acquisition is well known by people in the instrumentation field. Put simply, the sampling frequency must be at least twice the frequency of any signal to be sampled, or vice versa; the signals must be filtered so that none of the signal frequencies are higher than one-half the sample rate (the Nyquist Limit). Then, per Shannon's Sampling Theorem (1949, ref. 1), any sampled signal can be reconstructed for viewing on a display device. If any signals exceed the Nyquist frequency limit, error signals called aliases occur in the output display.

Williams, Glenn L.↗

Is a Linear or a Walkabout Protocol More Efficient When Using a Rover to Choose Biologically Relevant Samples in a Small Region of Interest?

We conducted a field test at a potential Mars analog site to provide insight into planning for future robotic missions such as Mars 2020, where science operations must facilitate efficient choice of biologically relevant sampling locations. We compared two data acquisition and decision-making protocols currently used by Mars Science Laboratory: (1) a linear approach, where sites are examined as they are encountered and (2) a walkabout approach, in which the field site is first examined with remote rover instruments to gain an understanding of regional context followed by deployment of time- and power-intensive contact and sampling instruments on a smaller subset of locations. The walkabout method was advantageous in terms of both the time required to execute and a greater confidence in results and interpretations, leading to enhanced ability to tailor follow-on observations to better address key science and sampling goals. This advantage is directly linked to the walkabout method's ability to provide broad geological context earlier in the science analysis process. For Mars 2020, and specifically for small regions to be explored (e.g., <1 sq. km), we recommend that the walkabout approach be considered where possible, to provide early context and time for the science team to develop a coherent suite of hypotheses and robust ways to test them.

R. Aileen Yingst↗

Elevated temperature viscous remanent magnetization of natural and synthetic multidomain magnetite

The time-temperature relationship of magnetization is a subject of much interest and debate by paleomagnetists, rock magnetists, and magnetic anomaly modellers. We have investigated this relationship by studying the viscous remanent magnetization (VRM) of coarse-grained multidomain (MD) magnetite. Our experiments covered the temperature range from 22 to 400 C, times from minutes to months, and included both Australian granulite samples and multidomain magnetite samples synthesized by the glass ceramic method. VRM acquisition was found to generally increase with temperature but not always at the rate predicted from classical thermal fluctuation theories. Thermal cycling between room temperature (at which the measurements were made) and the VRM acquisition temperature sharply decreased the temperature dependence of the VRM. Room temperature VRM acquisition accelerates with time when plotted on a semilog plot, whereas at elevated temperature the curves are quasilinear against log(time) for both the natural and synthetic samples. This change in behavior may suggest a variation in the VRM acquisition mechanism as a function of temperature for MD magnetite. The granulites have a nearly linear increase in VRM acquisition rate with temperature whereas the glass ceramics display little change in the acquisition rate between 22 and 200 C, but increase by nearly a factor of 3 by 400 C. The increase in VRM of the glass ceramics between 200 and 400 C is in general qualitative agreement with thermal fluctuation theory. There was no systematic change in the rate of VRM acquisition with grain size for the multidomain magnetites used in this study. Elevated temperature (e.g., 400 C) VRM acquisition by the deep crustal granulites, if extrapolated over the Brunhes chron, would produce a magnetization of several A/m which, if true, is of the order required by models for the source of long-wavelength magnetic anomalies.

Kelso, Paul R.↗

Rayleigh Scattering Diagnostic for Measurement of Velocity and Density Fluctuation Spectra

A new molecular Rayleigh scattering based flow diagnostic is used for the first time to measure the power spectrum of gas density and radial velocity component in the plumes of high speed jets. The technique is based on analyzing the Rayleigh scattered light with a Fabry-Perot interferometer used in the static, imaging mode. The PC based data acquisition system is capable of simultaneous sampling of velocity and density at rates to 100 kHz and data record lengths to 10 million. Velocity and density power spectra and velocity-density cross spectra are presented for a subsonic jet, an underexpanded screeching jet, and for Mach 1.4 and Mach 1.8 supersonic jets. Software and hardware interfaces were developed to allow computer control of all aspects of the experiment and data acquisition.

Seasholtz, Richard G.↗

Developing mass spectrometric techniques for boundary layer measurement in hypersonic high enthalpy test facilities

Thermodynamic flow properties of gases in the boundary layer or the flowfield have been mainly deduced from pressures and temperatures measured on a model. However, further progress with respect to an understanding of these properties requires a more complete characterization of the layer including determination of the gas composition and chemistry. Most attempts to measure boundary layer chemistry involve the employment of a mass spectrometer and an associated gas sampling system. The three major limiting factors which must be addressed for species measurement in aerothermodynamic investigations on models at reentry stream velocities, are gas sampling effects, instrument limitations, and problems with data acquisition. The present investigation is concerned with a concentrated effort to quantitatively identify and correct for instrument and sampling system effects, and to develop a miniaturized high performance mass spectrometer for on-model real-time analysis of the boundary layer and its associated atmosphere.

Wood, G. M., Jr.↗

Implementation of Remote Acquisition and Storage System

The existing system for gathering and processing acoustical test data had several shortcomings and limitations in the areas of microphone array size, sampling rate, and background noise. A new Remote Acquisition and Storage System (RASS) is being designed for applications not suited for the existing acquisition system. One of the first tasks in the design of the RASS was to redesign the microprocessor card of the existing system to include RS-232 serial ports to accept communications through the radio modem used in the RF link. Cost and parts availability comparisons were made between the newly designed board and commercially available models, and a commercially made model was selected. This model was tested for basic I/0 operations. The prototype of the RF telemetry system was set up and tested. Plans are now being developed for integrating the RF telemetry system with the other RASS subsystems.

Hess, Jason R.↗

Curating NASA's Future Extraterrestrial Sample Collections: How Do We Achieve Maximum Proficiency?

The Astromaterials Acquisition and Curation Office (henceforth referred to herein as NASA Curation Office) at NASA Johnson Space Center (JSC) is responsible for curating all of NASA's extraterrestrial samples. Under the governing document, NASA Policy Directive (NPD) 7100.10E "Curation of Extraterrestrial Materials", JSC is charged with "The curation of all extraterrestrial material under NASA control, including future NASA missions." The Directive goes on to define Curation as including "... documentation, preservation, preparation, and distribution of samples for research, education, and public outreach." Here we describe some of the ongoing efforts to ensure that the future activities of the NASA Curation Office are working towards a state of maximum proficiency.

McCubbin, Francis↗

Depth profiling and standardization from the back side of a sample for accurate analyses: Emphasis on quantifying low‐fluence, shallow implants in diamond‐like carbon

Rationale Back‐side thinning of wafers is used to eliminate issues with transient sputtering when analyzing near‐surface element distributions. Precise and accurate calibrated implants are created by including a standard reference material during the implantation. Combining these methods allows accurate analysis of low‐fluence, shallow features even if matrix effects are a concern. Methods Implanted Na (<2.0 × 10 11 ions/cm 2 , peaking <50 nm) in diamond‐like carbon (DLC) film on silicon (solar wind returned by NASA's Genesis mission) was prepared for measurement as follows. Implanted surfaces of samples were epoxied to wafers and back‐side‐thinned using physical or chemical methods. Thinned samples were then implanted with reference ions for accurate quantification of the solar wind implant. Analyses used a CAMECA IMS 7f‐GEO SIMS in depth‐profiling mode. Results Back‐side‐implanted reference ions reduced the need to change sample mounts or stage position and could be spatially separated from the solar wind implant even when measuring monoisotopic ions. Matrix effects in DLC were mitigated and the need to find an identical piece of DLC for a reference implant was eliminated. Accuracy was only limited by the back‐side technique itself. Conclusions Combining back‐side depth profiling with back‐side‐implanted internal standards aides quantification of shallow mono‐ and polyisotopic implants. This technique helps mitigate matrix effects and keeps measurement conditions consistent. Depth profile acquisition times are longer, but if sample matrices are homogeneous, procedural changes can decrease measurement times.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Data acquisition techniques for exploiting the uniqueness of the time-of-flight mass spectrometer: Application to sampling pulsed gas systems

Mass spectra are produced in most mass spectrometers by sweeping some parameter within the instrument as the sampled gases flow into the ion source. It is evident that any fluctuation in the gas during the sweep (mass scan) of the instrument causes the output spectrum to be skewed in its mass peak intensities. The time of flight mass spectrometer (TOFMS) with its fast, repetitive mode of operation produces spectra without skewing or varying instrument parameters and because all ion species are ejected from the ion source simultaneously, the spectra are inherently not skewed despite rapidly changing gas pressure or composition in the source. Methods of exploiting this feature by utilizing fast digital data acquisition systems, such as transient recorders and signal averagers which are commercially available are described. Applications of this technique are presented including TOFMS sampling of vapors produced by both pulsed and continuous laser heating of materials.

Lincoln, K. A.↗

Multi crop area estimation in Idaho using EDITOR

The use of LANDSAT multispectral scanner digital data for multi-crop acreage estimation in the central Snake River Plain of Idaho was examined. Two acquisitions of LANDSAT data covering ground sample units selected from a U.S. Department of Agriculture sampling frame in a four country study site were used to train a maximum likelihood classifier which, subsequently, classified all picture elements in the study site. Acreage estimates for six major crops, by county and for the four counties combined, were generated from the classification using the Battesse-Fuller model for estimation by regression in small areas. Results from the regression analysis were compared to those obtained by direct expansion of the ground data. Using the LANDSAT data significantly decreased the errors associated with the estimates for the three largest acreage crops. The late date of the second LANDSAT acquisition may have contributed to the poor results for three summer crops.

Sheffner, E. J.↗

Warm Pressurant Gas Effects on the Liquid Hydrogen Bubble Point

This paper presents experimental results for the liquid hydrogen bubble point tests using warm pressurant gases conducted at the Cryogenic Components Cell 7 facility at the NASA Glenn Research Center in Cleveland, Ohio. The purpose of the test series was to determine the effect of elevating the temperature of the pressurant gas on the performance of a liquid acquisition device. Three fine mesh screen samples (325 x 2300, 450 x 2750, 510 x 3600) were tested in liquid hydrogen using cold and warm noncondensible (gaseous helium) and condensable (gaseous hydrogen) pressurization schemes. Gases were conditioned from 0 to 90 K above the liquid temperature. Results clearly indicate a degradation in bubble point pressure using warm gas, with a greater reduction in performance using condensable over noncondensible pressurization. Degradation in the bubble point pressure is inversely proportional to screen porosity, as the coarsest mesh demonstrated the highest degradation. Results here have implication on both pressurization and LAD system design for all future cryogenic propulsion systems. A detailed review of historical heated gas tests is also presented for comparison to current results.

Liquid Hydrogen↗

Sampling synchronization through GPS signals

A method uses a distributed data acquisition system with multiple, physically unconnected, data acquisition units, that can be in wireless communication with a remote host, to timestamp measurement data with sub-microsecond time base accuracy of sampling clock relative to an absolute timeframe. A current absolute time is derived from messages received from a satellite radio beacon positioning system (GPS). Measurement data is sampled by each unit at a specified sampling rate. Using hardware logic, batches of sampled data are associated with corresponding timestamps representing the absolute time at which the data was sampled. Data and timestamps may be transmitted to the host. A time offset bias is compensated by comparing timestamps against a nominal time based on start time and nominal sampling rate. The sampling clock rate may be disciplined using time pulses from the GPS receiver. An initial start of data sampling by all units can also be synchronized.

Zhuge, James Q.↗