Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “results”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

A Workflow to Rapidly Interrogate Multiscale Model Simulation Results Across Multiple Length Scales

Many tools can be used to visualize field and state variables for a single scale analysis so that the influence of relevant mechanisms can be evaluated. Finite element software is often utilized to simulate a unit cell of a material and visualize results at that scale. Material properties can be homogenized from individual constituents and local deformation, damage, and failure mechanisms can be evaluated within the unit cell due to globally applied boundary conditions. Such solutions can produce satisfactory results if a user is only interested in analyzing a single scale. But materials in general contain features across multiple length scales, and assumptions must be made when attempting to account for lower length scale phenomena within a higher length scale model. Multiscale modeling is an attractive means to model materials because detailed material responses can be tracked across multiple disparate length scales while reducing the amount of required assumptions. However, as the complexity of these models increases, a large amount of data can be produced, and data traceability can become increasingly more difficult. Field and state variables, which are naturally dependent on spatial position, may themselves be calculated from one or more lower length scale unit cell models each with their own appropriate field and state variables. The NASA Multiscale Analysis Tool (NASMAT) is one software that can be used to perform a multiscale analysis efficiently and output requested data at all length scales in the analysis. A companion open-source Python software, NASMAT PrePost, can be used to visualize NASMAT model results and rapidly interrogate multiscale data across multiple length scales. This presentation will demonstrate some of the key features of NASMAT PrePost on two multiscale problems by quickly displaying and demonstrating connectivity among multiscale results from large datasets.

Python↗

A Summary of Test and Analysis Results from a Second Lift+Cruise Full-Scale Drop Test

The realization of advanced air mobility markets is enabling new forms of transportation to take shape in the United States and around the world. Though currently in development, as these markets mature, new types of vertical take-off and landing (VTOL) vehicles have been undergoing development for use. There are many factors which must be addressed prior to these types of vehicles becoming viable alternative forms of transportation in these markets. These factors include incorporation into the existing airspaces, the logistics of operating in urban environments, along with numerous factors associated with safety and reliability. To address some of the safety aspects associated with the development of these new types of vehicles, NASA has been conducting research into the performance of an example electric VTOL (eVTOL) aircraft as a part of the Revolutionary Vertical Lift Technology (RVLT) project. Over the course of this research, many aspects including the development of energy absorbing components, the evaluation of seating systems, the development of advanced finite element material model systems and the acquisition of full-scale vehicle impact data were investigated. The report will discuss aspects related to the acquisition of full-scale vehicle data which occurred in the form of a full-scale impact test conducted in the Summer of 2025. This test was on a NASA designed Lift+Cruise composite cabin test article and represented a partial capstone in the entirety of previous eVTOL research conducted for the project. In this test, a variety of experiments were included in order to investigate the effect of a full-scale environment on the experiment results. In parallel, the development of a computational impact model to simulate the full-scale test will be discussed in this report. A model of the Lift+Cruise test article was developed utilizing data collected from previous sub- and full-scale test data and then simulated in the current test environment. The model development, its use in pre-test predictions, and its use in post-test correlation will all be presented. This report will present the test data acquired from the Lift+Cruise test and document several of the results obtained. One intended result is to determine the effect of a complex full-scale crash impact on the identification of occupant injury risk within seat and vehicle designs. A second intended result is to determine whether high-fidelity models can be used with some confidence in the prediction of test events and can allow for additional test cases to be simulated without the need of having to conduct additional tests. The overall goal of the test is to provide the community with data that can be used for design, development or certification efforts, along with providing data on what an example eVTOL crash incident could entail.

energy storage systems↗

Assessment of Survey Results from Advanced Reactor Industry Domain Experts on Nonlinear Soil-Structure Interaction Analysis Software Verification and Validation

The seismic load case has a significant impact on the design and cost of nuclear power plants. Given the need to substantially reduce cost, advanced reactor designers are looking to leverage numerical tools that enable seismic analysis of an integrated vessel/support/structure/soil system. Modern nonlinear analysis tools provide a solution, capturing dynamic coupling between components (including soil-structure interaction (SSI)) concurrent with nonlinear behavior in one or more parts of the system. Although these methods have a rich history of technical development and implementation, software quality assurance (SQA) following nuclear industry standards remains a significant burden for those wishing to adopt such methods for advanced reactor design and licensing. To reduce the SQA burden, this project will develop the guidance for SQA verification and validation (V&V) of coupled nonlinear SSI analysis tools, to include a test matrix of software features and test problems to support commercial grade dedication (CGD). The guidance is intended to be technology-neutral: supporting designers of all advanced reactors. To maximize the value of the project to reactor designers, the project team performed focused surveys of and interviews with advanced reactor designers. Additionally, the project surveyed members of the broader industry involved in reactor design and licensing. The aggregated industry feedback consists of written survey responses, live polling responses, focused interviews, and informal feedback provided after outreach presentations, collectively referred to as “survey results”. Herein, the survey results are reported, reviewed, and assessed to inform follow-on project activities. The survey results confirmed the familiarity of the industry with the coupled nonlinear SSI analysis. They also affirm the project need based upon the expressed intent to (1) incorporate nonlinear features and (2) pursue the coupled nonlinear SSI analysis to reduce seismic demands and construction costs. All reactor designers indicated their intent to incorporate two or more nonlinear features, and all reactor designer respondents opined that the coupled nonlinear SSI analysis would allow for the optimization of the reactor design and construction. However, the programmatic challenges, whether real or perceived, present a significant barrier to reactor designers. The barrier most commonly identified by the reactor designer population was regulatory risk, with 70% citing this as a reason not to pursue the approach. The perceived regulatory risk identified by the reactor designers underscores the importance of regulator engagement and dialogue in this project. Additionally, half of the reactor designers identified cost and lack of guidance as a deterrent. The survey results also provide insights to tailor specific aspects of the guidance document and test matrix. The project plans to prepare both a formal referenceable guidance document and a collaborative, web-based test matrix and problem set. The project will focus on more complete test problem definitions for the prioritized nonlinear features over shallower problem descriptions for a larger set of features. The nonlinearities prioritized as high based upon survey feedback include fluid-structure interaction and seismic isolation and energy dissipation devices. The nonlinearities prioritized as intermediate include nonlinear geomaterials, nonlinear concrete, nonlinear steel, and interface/contact nonlinearity. Deep embedment and the associated nonlinear phenomena are assigned the lowest priority based upon survey feedback.

42 ENGINEERING↗

Results from Laboratory and Field Study of Thin Triple Pane Windows

Heat transfer through windows accounts for a significant percentage of a building’s energy use and adds substantially to the peak cooling load of a home. In recent years, improvements in glass manufacturing have enabled the use of a very thin central pane of glass similar to a cell phone screen to produce a thin triple-pane window, for finished insulated glass units (IGUs) with an overall thickness similar to standard double-pane windows. Because this highly insulating “thin triple” glass product can be incorporated into almost any existing window frame and can be fabricated at a modest added cost, the U.S. Department of Energy sponsored laboratory and field demonstration testing of thin triple-pane windows to validate thermal performance and installation requirements in real-life field settings. Thin triple pane windows were evaluated at the PNNL Lab Homes, a matched pair of manufactured houses located on PNNL’s campus in Richland, Washington and also at 16 different field study sites around the country. The experimental results include a comparison of heating, ventilation, and air-conditioning (HVAC) energy usage, condensation potential, occupant comfort, sound infiltration, and thermal performance. Field study data will be gathered through June of 2022; preliminary results are being shared in this paper. The lab houses are identical except that the reference house had standard double pane windows with assembly U-0.66 and the test house had thin triple pane windows with assembly U-0.19. Across the experimental test days, the daily HVAC savings ranged from 0.2 to 18.7 kWh (3%–18%) for the heating season and from 2.5 to 8.0 kWh (23%–41%) for the cooling season. The higher thermal performance of the thin triple-pane windows also reduced the condensation potential on the interior surface during winter months and provided more even distribution of temperatures throughout the home in comparison to the baseline. In addition to the added thermal performance, the thin triple-pane windows demonstrated significant acoustic benefits, reducing sound infiltration by 8 dB to 10 dB. For the field test portion of the project thin triple pane insulated glass units were produced by two different manufacturers, and then installed without modification into the ½” IGU pockets of the standard double pane frames of four other manufacturers. Field tests performed on existing homes in Washington, Montana, Colorado, and New York compared thin triple pane retrofits to original window conditions (before and after). Field tests at new construction sites in Minnesota, Michigan, and New York compared thin triple pane windows to commercially available solutions such as double pane or traditional triple pane (with a standard-thickness center pane). Field test work is ongoing, but preliminary results appear to follow the sound, surface temperature, and energy improvement results from the Lab Homes comparison. Additionally, reports from builders and installers indicate that thin triples require almost no added time or effort to install and look nearly identical to other windows, indicating the possibility of offering next-level performance with a product that requires very little modification to current production or installation practices, long considered a major barrier to technology uptake in the construction market.

energy efficiency, home retrofit, Windows, window ↗

New results from the Muon g-2 Experiment

The Muon g-2 experiment at Fermilab has published the first result on Run-1 dataset in 2021 showing a good agreement with the previous experimental result at Brookhaven National Laboratory at comparable precision (0.46 ppm). In August 2023 we released our new result from Run-2 and Run-3 datasets which allowed to measure $a_\mu$ to 0.21 ppm, a more than two-fold improved precision respect to Run-1, and which allowed to reach a precision of 0.20 ppm when combined with the Run-1 result. We will discuss the improvements of the Run-2/3 analysis respect to Run-1, the current status of the theory prediction, and the future prospects.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Results of a Soil Flushing Treatability Test for Hanford Site Hexavalent Chromium Removal - 20446

U.S. Department of Energy contractor CH2M Hill Plateau Remediation Company has made significant progress remediating hexavalent chromium in groundwater near the Columbia River through the operation of pump and treat facilities and source removal activities. To mitigate risks associated with hexavalent chromium contamination, which was identified in a CERCLA interim action record of decision as the primary groundwater contaminant of concern for the 100-KR-4 Operable Unit from discharging to the Columbia River, three ion-exchange pump and treat systems were installed between 1997 and 2009. Between 2010 and 2016, operation of the K West pump and treat system, located near the former 105K West plutonium production reactor, reduced concentrations below the groundwater remediation target for hexavalent chromium. In 2016, a rebound study was performed to evaluate the effectiveness of the pump and treat remedy and assess the potential for any residual hexavalent chromium sources continuing to contribute to groundwater contamination. As a result of the rebound study, a source of continued groundwater contamination was identified. To address this condition, a soil flushing treatability test was written and approved by the U.S. Department of Energy and the U.S. Environmental Protection Agency. The test included saturating about a 1-acre area of soil with treated water with the goal of forcing the residual hexavalent chromium to groundwater where existing extraction wells could remove it for treatment, accelerating the cleanup process. In spring and summer 2019, CH2M Hill Plateau Remediation Company installed and began operating a shallow underground leach system to support the treatability test. Preliminary sampling data show the test was effective in removing the residual contamination. Following further evaluation and analysis from the initial test, the process will be considered for implementation elsewhere on the Hanford Site, particularly at locations where there is a known or suspected continuing contamination source in the soil column. The paper will cover the goals of the study, as well as more details about the following: - Overview of pump and treat exit strategy (using U.S. Environmental Protection Agency guidance); - The design and installation of the soil flushing technology in the 100-K Area; - The testing process and results of sampling data; - Post-study evaluation and potential for implementation in other locations at the Hanford Site. Innovative solutions for cleanup, such as the soil flushing technology, have resulted in substantial progress in the removal of groundwater contaminants at the Hanford Site, potentially shortening the time frame required to meet cleanup goals and resulting in significant cost savings. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Shake Test Results and Dynamic Calibration Efforts for the Large Rotor Test Apparatus

Prior to the full-scale wind tunnel test of the UH-60A Airloads rotor, a shake test was completed on the Large Rotor Test Apparatus. The goal of the shake test was to characterize the oscillatory response of the test rig and provide a dynamic calibration of the balance to accurately measure vibratory hub loads. This paper provides a summary of the shake test results, including balance, shaft bending gauge, and accelerometer measurements. Sensitivity to hub mass and angle of attack were investigated during the shake test. Hub mass was found to have an important impact on the vibratory forces and moments measured at the balance, especially near the UH-60A 4/rev frequency. Comparisons were made between the accelerometer data and an existing finite-element model, showing agreement on mode shapes, but not on natural frequencies. Finally, the results of a simple dynamic calibration are presented, showing the effects of changes in hub mass. The results show that the shake test data can be used to correct in-plane loads measurements up to 10 Hz and normal loads up to 30 Hz.

Large Rotor Test Apparatus↗

Comparing Simulation Results from CHARM and RotCFD to the Multirotor Test Bed Experimental Data

Advanced multirotor vertical flight aircraft concepts are emerging faster than rigorous individualized tests can investigate their utility and performance. There are several analysis tools that predict multirotor performance and flow characteristics, but the accuracy of these predictions is still being debated due to lack of experimental data from multirotor tests that are needed to validate the analyses. The objective of this paper is to simulate multirotor configurations using two different mid-fidelity rotorcraft analysis tools, Comprehensive Hierarchical Aeromechanics Rotorcraft Model (CHARM) and Rotorcraft Computational Fluid Dynamics (RotCFD), and compare the simulation results to experimental data from a wind tunnel test of the Multirotor Test Bed (MTB). The MTB, developed by NASA Ames Research Center, is a new capability for testing a wide array of advanced vertical take-off and landing (VTOL) rotor configurations, with a primary focus on testing in the U.S. Army 7-by 10-Foot Wind Tunnel at NASA Ames Research Center. The MTB was designed to allow adjustment of the vertical, lateral, and longitudinal placement of up to six rotors, as well as allow tilt adjustment of each rotor and pitch adjustment of the whole assembly. The six-axis load cells under each rotor give the MTB the capability of measuring the rotor performance in a wide array of configurations. The overall goal of the MTB project is to help gain a better understanding of the performance, control, interactional aerodynamics, and acoustics of multirotor and tilting-rotor systems. For the work presented here, the MTB data were used to validate RotCFD and CHARM results for several multirotor test configurations. With confidence in both analyses established by the validation exercise, additional simulations were performed to explore quadrotor configurations that will be tested during the MTB’s second wind tunnel entry planned for 2022. This second tunnel entry will examine quadrotor configurations that represent published NASA reference designs for urban air mobility concept vehicles. Results from this paper confirm the ability of RotCFD and CHARM to simulate multirotor aerodynamic interactions on individual rotor performance under edgewise forward-flight conditions.

CHARM↗

Issue Summary of INL Phase IV Transient Results for IAEA CRP on HTGR UAM Benchmark

This report details the Parallel and Highly Innovative Simulation for Idaho National Laboratory (INL) Code System (PHISICS)/Reactor Excursions and Leak Analysis Program (RELAP5)-3D results obtained for the transient core exercises defined for Phase IV of the International Atomic Energy Agency (IAEA) Coordinated Research Project (CRP) on high-temperature gas cooled reactor (HTGR) uncertainty analysis in modeling (UAM). The Phase III models and results are linked to the earlier Standardized Computer Analyses for Licensing Evaluation (SCALE)/Sampler/New ESC-based Weighting Transport (NEWT) data generated for the lattice physics (lattice) stage Phase I of the CRP. The focus of this report is the Uncertainty/Sensitivity Assessment (U/SA) of the prismatic modular high-temperature gas cooled reactor (MHTGR)-350 design, and specifically for Exercises IV-1 and IV-2 of the benchmark: the Control Rod Withdrawal (CRW) and Pressurised Loss of Cooling (PLOFC) events. The statistical U/SA methodology is implemented and demonstrated using the RAVEN code, based on perturbed cross-section libraries obtained from the SCALE/Sampler sequence. Uncertainties in nuclear data (cross-sections and the average number of neutrons produced per fission, 235U[¯v ]) lead to standard deviations (uncertainties of one s) of approximately 0.5% in the core eigenvalues of the MHTGR-350 and core models. For the coupled neutronics/thermal fluid model, local power density uncertainties up to 3.6% were observed in the colder regions of the core, while the local maximum fuel temperature uncertainties reached 1.5% for the models that included thermal fluid uncertainties. The addition of thermal fluid uncertainties dominated the impacts of nuclear data uncertainties in all cases. The main contributors to uncertainties in the power density and fuel temperatures during the transients were uncertainties in the reactor operating conditions (total power, inlet mass flow rate and inlet gas temperature). Variations in the bypass flows did not have significant impact on any of the output variables. For the nuclear data uncertainties it was found that the 235U(¯v ) / 235U(¯v ) covariance produced the largest sensitivities in terms of its impact on the eigenvalue and peak reactor power. It was also observed that the impact of any nuclear data uncertainties on the maximum fuel temperature was much less significant that the impact on eigenvalue and power. Another important finding was that although the use of eight or more energy groups is recommended for best-estimate HTGR simulation, two-group models produced acceptable uncertainty and sensitivity results for most FOMs. Since the statistical U/SA methodology is computationally expensive, and most transient solver requirements will scale directly with the number of energy groups, two energy groups could be used by HTGR developers during the early stages of design when larger uncertainty margins can be tolerated.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Summary of Alloy 617 and Alloy 709 Elevated Temperature Crack Growth Test Results from the Planned FY24 Crack Growth Test Activities

This report covers the results from crack growth rate testing performed at Idaho National Laboratory in the fiscal year 2024. It includes two creep crack growth rate tests and two creep-fatigue crack growth rate tests. Results are shown for each of these tests, included crack growth measured during the test using direct current potential drop, and measurements based off of the fracture surface. Load line displacement, as well as load, were also collected during the tests. Detailed analysis of the results will continue into the next fiscal year, however, a number of potential improvements to the equipment and testing procedures were identified that will increase testing reliability and throughput, as well as decrease complications with the analysis.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

The Influence of Mesoscale Particle Structure on the Electrode Degradation and Resultant Electrochemistry of Lithium Ion Cells With Nickel Rich Lithium Nickel Manganese Cobalt Oxide Positive Electrodes

Nickel-rich lithium nickel manganese cobalt oxide, NMC (LiNi x Mn y Co z O 2 ), materials are desirable positive electrodes in lithium ion batteries, providing high capacity and energy density. The mesoscale structure of NMC materials is commonly a polycrystalline aggregate, providing opportunity for short lithium ion transport distance of the small primary particles, yet facile material handling due to the larger secondary particles. On (de)lithiation the NMC unit cell changes volume, where the anisotropic strain can result in secondary particle fracture. This secondary particle fracture process during cycling has been associated with several degradation modes of NMC materials in LIBs. In this work, a milling process was determined whereby the secondary particles could be pre-fractured with retention of the parent primary particle crystallographic structure, crystallite size, and morphology, providing the ability to unambiguously determine the influence of NMC secondary particle size and mesostructure on resultant functional behavior. The bulk and interfacial properties and electrochemistry of as-received commercially obtained polycrystal NMC811 (LiNi 0.8 Mn 0.1 Co 0.1 O 2 , PC NMC) and its milled MPC NMC counterpart were compared. The smaller secondary particle size, higher surface area MPC NMC was found to result in 1) greater cathode tortuosity, 2) reduced surface Ni on the cycled MPC cathodes consistent with surface reconstruction, and 3) increased Ni deposition on the anodes from cathode-anode crosstalk. These factors manifested in unfavorable electrochemical behavior of MPC with lower functional capacity at both 1C and C/10 rates and higher impedance over extended moderate voltage (dis)charge cycling.

36 MATERIALS SCIENCE↗

Results of a Geant4 benchmarking study for bio‐medical applications, performed with the G4‐Med system

Geant4, a Monte Carlo Simulation Toolkit extensively used in bio-medical physics, is in continuous evolution to include newest research findings to improve its accuracy and to respond to the evolving needs of a very diverse user community. In 2014, the G4-Med benchmarking system was born from the effort of the Geant4 Medical Simulation Benchmarking Group, to benchmark and monitor the evolution of Geant4 for medical physics applications. The G4-Med system was first described in our Medical Physics Special Report published in 2021. Results of the tests were reported for Geant4 10.5. Purpose In this work, we describe the evolution of the G4-Med benchmarking system. Methods The G4-Med benchmarking suite currently includes 23 tests, which benchmark Geant4 from the calculation of basic physical quantities to the simulation of more clinically relevant set-ups. New tests concern the benchmarking of Geant4-DNA physics and chemistry components for regression testing purposes, dosimetry for brachytherapy with a 125 I source, dosimetry for external x-ray and electron FLASH radiotherapy, experimental microdosimetry for proton therapy, and in vivo PET for carbon and oxygen beams. Regression testing has been performed between Geant4 10.5 and 11.1. Finally, a simple Geant4 simulation has been developed and used to compare Geant4 EM physics constructors and physics lists in terms of execution times. Results In summary, our EM tests show that the parameters of the multiple scattering in the Geant4 EM constructor G4EmStandardPhysics_option3 in Geant4 11.1, while improving the modeling of the electron backscattering in high atomic number targets, are not adequate for dosimetry for clinical x-ray and electron beams. Therefore, these parameters have been reverted back to those of Geant4 10.5 in Geant4 11.2.1. The x-ray radiotherapy test shows significant differences in the modeling of the bremsstrahlung process, especially between G4EmPenelopePhysics and the other constructors under study (G4EmLivermorePhysics, G4EmStandardPhysics_option3, and G4EmStandardPhysics_option4). These differences will be studied in an in-depth investigation within our Group. Improvement in Geant4 11.1 has been observed for the modeling of the proton and carbon ion Bragg peak with energies of clinical interest, thanks to the adoption of ICRU90 to calculate the low energy proton stopping powers in water and of the Linhard–Sorensen ion model, available in Geant4 since version 11.0. Nuclear fragmentation tests of interest for carbon ion therapy show differences between Geant4 10.5 and 11.1 in terms of fragment yields. In particular, a higher production of boron fragments is observed with Geant4 11.1, leading to a better agreement with reference data for this fragment. Conclusions Based on the overall results of our tests, we recommend to use G4EmStandardPhysics_option4 as EM constructor and QGSP_BIC_HP with G4EmStandardPhysics_option4, for hadrontherapy applications. The Geant4-DNA physics lists report differences in modeling electron interactions in water, however, the tests have a pure regression testing purpose so no recommendation can be formulated.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Degradation in photovoltaic encapsulation strength of attachment: Results of the first PVQAT TG5 artificial weathering study

Delamination of the encapsulant in photovoltaic (PV) module technology results in immediate optical loss and may enable subsequent corrosion or mechanical damage. The effects of artificial weathering were not previously known; therefore, an empirical study was performed to survey the factors most affecting adhesion, including the ultraviolet (UV) source (ie, Xe or fluorescent lamp[s]), the optical filters for the lamp, the chamber temperature, and the relative humidity. Natural weathering was also performed at locations, including the following: Golden, Colorado; Miami, Florida; Phoenix, Arizona; QiongHai, China; Riyadh, Saudi Arabia; and Turpan, China. Specimens were constructed using a laminated glass/poly (ethylene-co-vinyl acetate)/glass geometry. The compressive shear test (CST) was used to quantify the mechanical strength of attachment, taken as a proxy for adhesion. The fractography of select specimens (including cross-sectional optical microscopy) was used to verify the failure mode (delamination or decohesion). Additional analysis of the local solar spectrum as well as the specimen temperature was performed to interpret the results of natural weathering. The goals of this study include to identify the most significant stressors, clarify where strong coupling may occur between stressors, and validate accelerated test results relative to natural weathering. The importance of specimen conditioning (for moisture) and hygrometric degradation as well as the effects of UV degradation are identified in this paper.

14 SOLAR ENERGY↗

Results from an international interlaboratory study on light‐ and elevated temperature‐induced degradation in solar modules

Abstract This paper reports the results of an international interlaboratory comparison study on light‐ and elevated temperature‐induced degradation (LETID) on crystalline silicon photovoltaic (PV) modules. A large global network of PV module manufacturers and PV testing laboratories collaborated to design a protocol for LETID detection and screen a large and diverse set of prototype modules for LETID. Results across labs indicate the reproducibility of LETID testing is likely within ±1% of maximum power (P MP ). In intentionally engineered LETID‐sensitive modules, mean degradation after the prescribed detection stress is roughly 6% P MP . In other module types the LETID sensitivity is smaller, and in some we observe essentially negligible degradation attributable to LETID. In LETID‐sensitive modules, both open‐circuit voltage (V OC ) and short‐circuit current (I SC ) degrade by a roughly similar magnitude. We observe, as do previous studies, that LETID affects each cell in a module differently. An investigation of the potential mismatch losses caused by nonuniform LETID degradation found that mismatch loss is insignificant compared to the estimated loss of cell I SC , which drives loss of module I SC . Overall, this work has helped inform the creation of a forthcoming standard technical specification for LETID testing of PV modules, IEC TS 63342 ED1, and should aid in the interpretation of results from that and other LETID tests.

14 SOLAR ENERGY↗

Vector boson pair production at one loop: analytic results for the process $q\bar{q}$$ℓ\bar{ℓ}$$ℓ'\bar{ℓ}'g$

We present compact analytic results for the one-loop amplitude for the process 0 → $q\bar{q}$$ℓ\bar{ℓ}$$ℓ'\bar{ℓ}'g$, relevant for both the production of a pair of Z and W-bosons in association with a jet. We focus on the gauge-invariant contribution mediated by a loop of quarks. We explicitly include all effects of the loop-quark mass m, appropriate for the production of a pair of Z-bosons. In the limit m → 0, our results are also applicable to the production of W-boson pairs, mediated by a loop of massless quarks. Implemented in a numerical code, the results are fast. The calculation uses novel advancements in spinor-helicity simplification techniques, for the first time applied beyond five-point massless kinematics. We make use of primary decompositions from algebraic-geometry, which now involve non-radical ideals, and p-adic numbers from number theory. We show how to infer whether numerator polynomials belong to symbolic powers of non-radical ideals through numerical evaluations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Balloon-Occluded Transcatheter Arterial Chemoembolization (b-TACE) for Hepatocellular Carcinoma Performed with Polyethylene-Glycol Epirubicin-Loaded Drug-Eluting Embolics: Safety and Preliminary Results

Purpose: To report technical success, safety profile and oncological results of balloon-occluded transcatheter arterial chemoembolization using a balloon micro-catheter and epirubicin-loaded polyethylene-glycol (PEG) microsphere (100 ± 25 µm and 200 ± 50 µm) in patients with hepatocellular carcinoma (HCC). Materials and Methods: This is a single-centre, single-arm, retrospective study with 6-month follow-up. Twenty-two patients (Child–Pugh A 68% [15/22], B in 32% [7/22]; age 67.05 ± 14 years) with 29 HCC were treated in 24 procedures. Technical success is defined: ability to place the balloon micro-catheter within the required vascular segment, balloon-occluded arterial stump pressure drops and assessment of microsphere deposition. Laboratory assessment pre/post-procedural and complications were analysed, respectively, according to Common Terminology Criteria for Adverse Events (CTCAEv5) and CIRSE system. Postembolization syndrome (PES) was defined as fever and/or nausea and/or pain onset. Oncological results were evaluated using m-RECIST criteria with CT/MRI imaging at 1 and 3–6 months. In partial responder patients, pre/post-procedural tumour volume was compared. Results: Pre-planned feeder was reached in all cases. Pressure drop average was 51.1 ± 21.6 mmHg. Exclusive target embolization was achieved in 14/24 procedures (58.3%). Laboratory test modifications were all grade 1. 4/24 adverse events occurred (17%): pseudo-aneurysm of the feeder (grade 3), liver abscess (grade 2) and 2 asymptomatic segmentary biliary tree dilatations (grade 2). PES occurred in 8/24 (33%). The complete response at 1 and 3–6 months was 44.8% (13/29) and 52.9% (9/17), respectively. The partial response at 1 and 3–6 months was 55% (16/29) and 4/17 (23.5%), respectively. Among partial responder patients, the average percentage of tumour volume reduction was 64.9 ± 27.3%. Conclusion: Epirubicin-loaded PEG microsphere b-TACE is technically feasible, safe and effective procedure for HCC treatment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

CCUS deployment under the U.S. 45Q tax credit and adaptation by other North American Governments: MARKAL modeling results

In 2018, U.S. Congress passed the Bipartisan Budget Act, known as 45Q [H.R. 3761], expanding the corporate income tax credit for carbon capture utilization and storage (CCUS). 45Q provides a performance-based tax credit for carbon capture projects of $30/ton of carbon dioxide (CO 2 ) (tCO 2 ) for anthropogenic CO 2 going to enhanced oil recovery (EOR), and $50/tCO 2 if going to straight storage. There are several conditions; for example, there is a 12-year time limit on tax credits for a new plant that commences construction before 2024 [H.R. 3761]. Here, this study aims to test the incremental impact of the 45Q tax credits on CCUS deployment, CO 2 -EOR, and power generation technological changes for North American (the United States, Canada, and Mexico) long-term energy system development. The scenario results show that offering a 12-year CO 2 storage subsidy provides the motivation needed for CCUS investment during the 12-year subsidy period, and the benefits of such investment can be sustained over the 40-year lifetime under CO 2 taxation. The modeling results show that carbon capture generation replaces uncontrolled fossil-fueled power, not new or existing renewables, so power generation and corresponding emission reductions from renewables remain unaffected by the availability of 45Q in the United States. Our scenario with CCUS technological learning indicates that CCUS could play a very important role under stringent environmental constraints. Thus, accelerated support and funding for the large-scale CCUS demonstrations is important for the execution of both short- and long-term climate mitigation goals. Given the significant role of the United States, Canada, and Mexico on the world energy system, our results represent an important contribution to the study of global energy trends.

42 ENGINEERING↗

Impact of carbon dioxide removal technologies on deep decarbonization: EMF37 MARKAL–NETL modeling results

Here this paper examines the MARKAL-NETL modeling results for the Energy Modeling Forum Study on Deep Decarbonization & High Electrification Scenarios for North America (EMF 37) with specific focus on carbon dioxide removal (CDR) technologies and opportunities under different scenarios guidelines, policies, and technological advancements. The results demonstrate that CDR, such as, bioenergy with carbon capture and storage (BECCS), direct air capture (DAC) and afforestation are key negative emission technologies in deep decarbonization scenarios in the U.S. are accounted for about 70% of annually avoided carbon dioxide emissions (CO 2 ) by 2050, or more than 2 billion tons of CO 2 (GtCO 2 ). The potential scale of CDR and its impact on the energy system depends on energy supply and demand technologies advancement and their costs, the level of end-use sectors electrification, availability and costs of CDR. Results show that the carbon prices are substantially lower if the advanced technologies available, particularly, in carbon management scenarios.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗