Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “radiometry”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Solar Radiometry and Metrology, Session: Modeling and Analysis (Presentation)

This project supports the Solar America Initiative by: (1) Providing solar radiometric measurements, data, and related technical information support to NREL Measurements and Characterization Task; NREL Reliability and Durability Task; Systems and component testing and evaluation for the SAI TPPs; Requests from industry; (2) Producing credible radiometric measurements traceable to recognized standards for performance and Industry applications in accordance with IS0-17025 accreditation scope; (3) Contributing to consensus codes and standards for performance and measurement techniques for NREL R&D, SAI TPPs, and industry applications; (4) Maintain stability of the NREL solar radiation reference (absolute cavity radiometers); (5) Execute high quality detailed radiometric calibrations for broadband and spectral radiometers to meet NREL research and PV industry needs; (6) Participate in national and international consensus standards development, contributing technical expertise, data, and analysis where appropriate; (7) Provide technical information on solar radiation resource data and applications to meet research and industry needs; and (8) Transfer technology in this area to other researchers and industry via publications and conference papers and presentations.

14 SOLAR ENERGY↗

Extending Aquatic Spectral Information with the First Radiometric IR-B Field Observations

Planetary radiometric observations enable remote sensing of biogeochemical parameters to describe spatiotemporal variability in aquatic ecosystems. For approximately the last half century, the science of aquatic radiometry has established a knowledge base using primarily, but not exclusively, visible wavelengths. Scientific subdisciplines supporting aquatic radiometry have evolved hardware, software, and procedures to maximize competency for exploiting visible wavelength information. This perspective culminates with the science requirement that visible spectral resolution must be continually increased to extract more information. Other sources of information, meanwhile, remain underexploited, particularly information from nonvisible wavelengths. Herein, absolute radiometry is used to evaluate spectral limits for deriving and exploiting aquatic data products, specifically the normalized water-leaving radiance, Γ(λ)⁠, and its derivative products. Radiometric observations presented herein are quality assured for individual wavebands, and spectral verification is conducted by analyzing celestial radiometric results, comparing agreement of above- and in-water observations at applicable wavelengths, and evaluating consistency with bio-optical models and optical theory. The results presented include the first absolute radiometric field observations of Γ(λ) within the IR-B spectral domain (i.e. spanning 1400–3000 nm), which indicate that IR-B signals confer greater and more variable flux than formerly ascribed. Black-pixel processing, a routine correction in satellite and in situ aquatic radiometry wherein a spectrum is offset corrected relative to a nonvisible waveband (often IR-B or a shorter legacy waveband) set to a null value, is shown to degrade aquatic spectra and derived biogeochemical parameters.

aquatic optics↗

Characterizing particle-based thermal storage performance using optical methods for use in next generation concentrating solar power plants

Concentrating Solar Power (CSP) generation is an attractive option for low-emission power generation; however, the high costs of thermal storage associated with concentrating solar create a large barrier for their use and adaptation into modern life. Lowering their operation costs, while maintaining high thermal storage and transfer performance is essential. Solid particle-based heat exchange systems can reduce CSP cost but are often less efficient. Efforts to increase their performance have led to use of binary size particle mixes. Presented is an optical-based thermal analysis technique used to measure near-wall thermal conductivity of particle beds essential in determining their heat exchanger efficiency. Modulated Photothermal Radiometry is used to make dynamic temperature measurements, allowing for the extraction of the most relevant thermal properties like thermal conductivity, specific heat, and effusivity. The system uses a modulated laser source causing a damped periodic heat flux, resulting in a frequency and thermal property dependent surface temperature, of which is measured using radiometry. Lock-In techniques are used to extrapolate the amplitude of the signal. Plotting the amplitude against the root angular frequency allows for effusivity measurement by ratio to a known sample. Using specific heat measurements from literature and density measurements, the thermal conductivity of the particle mixes can be calculated. The simplicity of MPTR to probe through the depth of the bed is ideal for use in CSP for dynamic thermal performance monitoring.

Corona, Javier↗

Passive measurement and interpretation of polarized microwave brightness temperatures

The goal of this project is to develop satellite-based observational techniques for measuring both oceanic and atmospheric variables using passive polarimetric radiometry. Polarimetric radiometry offers a potential alternative to radar scatterometry in observing global ocean surface wind direction from satellites. Polarimetric radiometry might also provide a means of detecting cell-top ice in convective storms by virtue of the polarizing properties of oriented ice particles, and thus facilitate estimation of the phase of the storm. The project focuses on the development of polarimetric microwave radiometers using digital cross-correlators for obtaining precise measurements of all four Stokes' parameters. As part of the project a unique four-band polarimetric imaging radiometer, the Polar Scanning Radiometer (PSR), is being designed for use on the NASA DC-8 aircraft. In addition to providing an aircraft-based demonstration of digital correlation technology the PSR will significantly enhance the microwave imaging capability of the existing suite of DC-8 instruments. During the first grant year excellent progress has been made in the following areas: (1) demonstrating digital correlation radiometry, (2) fabricating aircraft-qualified correlators for use in the PSR, and (3) modeling observed SSM/I brightness signatures of ocean wind direction.

Gasiewski, A. J.↗

Basic data requirements for microwave radiometer systems

Microwave radiometry has emerged over the last two decades to become an integral part of the field of environmental remote sensing. Numerous investigations were conducted to evaluate the use of microwave radiometry for atmospheric, oceanographic, hydrological, and geological applications. Remote sensing of the earth using microwave radiometry began in 1968 by the Soviet satellite Cosmos 243, which included four microwave radiometers (Ulably, 1981). Since then, microwave radiometers were included onboard many spacecraft, and were used to infer many physical parameters. Some of the basic concepts of radiometric emission and measurement will be discussed. Several radiometer systems are presented and an overview of their operation is discussed. From the description of the radiometer operation the data stream required from the radiometer and the general type of algorithm required for the measurement is discussed.

Lawrence, R. W.↗

Coherent systems in the terahertz frequency range: Elements, operation, and examples

The topics are presented in viewgraph form and include the following: terahertz coherent systems applications; a brief overview of selected components; radiometry and spectroscopy--astronomy; radiometry--aircraft all weather landing system; radiometry--atmospheric remote sensing; plasma diagnostics; communications; radar systems; and materials measurement and manufacturing process control.

Goldsmith, Paul F.↗

A Common Calibration Source Framework for Fully-Polarimetric and Interferometric Radiometers

Two types of microwave radiometry--synthetic thinned array radiometry (STAR) and fully-polarimetric (FP) radiometry--have received increasing attention during the last several years. STAR radiometers offer a technological solution to achieving high spatial resolution imaging from orbit without requiring a filled aperture or a moving antenna, and FP radiometers measure extra polarization state information upon which entirely new or more robust geophysical retrieval algorithms can be based. Radiometer configurations used for both STAR and FP instruments share one fundamental feature that distinguishes them from more 'standard' radiometers, namely, they measure correlations between pairs of microwave signals. The calibration requirements for correlation radiometers are broader than those for standard radiometers. Quantities of interest include total powers, complex correlation coefficients, various offsets, and possible nonlinearities. A candidate for an ideal calibration source would be one that injects test signals with precisely controllable correlation coefficients and absolute powers simultaneously into a pair of receivers, permitting all of these calibration quantities to be measured. The complex nature of correlation radiometer calibration, coupled with certain inherent similarities between STAR and FP instruments, suggests significant leverage in addressing both problems together. Recognizing this, a project was recently begun at NASA Goddard Space Flight Center to develop a compact low-power subsystem for spaceflight STAR or FP receiver calibration. We present a common theoretical framework for the design of signals for a controlled correlation calibration source. A statistical model is described, along with temporal and spectral constraints on such signals. Finally, a method for realizing these signals is demonstrated using a Matlab-based implementation.

Kim, Edward J.↗

Overview of ACE-Asia Spring 2001 Investigations On Aerosol-Radiation Interactions

ACE-Asia's extensive measurements from land, ocean, air and space quantified aerosol-radiation interactions. Results from each platform type, plus satellite-suborbital combinations, include: 1. Time series of multiwavelength aerosol optical depth (ADD), Angstrom exponent (alpha), single-scattering albedo (SSA), and size distribution from AERONET radiometry at 13 stations. In China and Korea AOD and alpha were strongly anticorrelated (reflecting transient dust events); dust volume-size modes peaked near 8 microns diameter; and SSA(dust) greater than SSA(pollution). 2. Calculations and measurements of photosynthetically active radiation and aerosols in China yield 24-h average downward surface radiative forcing per AOD(500 nm) of -27 W/sq m (400-700 nm). 3. The Hawaii-Japan cruise sampled a gradient with AOD(500 nm) extremes of 0.1 and 1.1. Shipboard measurements showed that adding dust to pollution increased SSA(550 nm, 55% RH), typically from -0.91 to approx. 0.97. Downwelling 8-12 micron radiances showed aerosol effects, especially in the major April dust event, with longwave forcing estimated at -5 to 15 W/sq m. 4. Extinction profiles from airborne sunphotometry and total-direct-diffuse radiometry show wavelength dependence often varying strongly with height, reflecting layering of dust-dominated over pollution-dominated aerosols. Comparing sunphotometric extinction profiles to those from in situ measurements (number and composition vs size, or scattering and absorption) shows layer heights agree, but extinction sometimes differs. 5. Airborne solar spectral flux radiometry yields absorption spectra for layers. Combining with AOD spectra yields best-fit aerosol single scattering albedo spectra. 6. Visible, NIR and total solar fluxes combined with AOD give radiative forcing efficiencies at surface and aloft.

Russell, P. B.↗

Solar System Studies with the Space Infrared Telescope Facility (SIRTF)

SIRTF (Space Infrared Telescope Facility) is the final element in NASA's 'Great Observatories' program. It consists of an 85-cm cryogenically-cooled observatory for infrared astronomy from space. SIRTF is scheduled for launch in late 2001 or early 2002 on a Delta rocket into a heliocentric orbit trailing the Earth. Data from SIRTF will be processed and disseminated to the community through the SIRTF Science Center (SSC) located at the Infrared Processing and Analysis Center (IPAC) at Caltech. Some 80/% of the total observing time (estimated at a minimum of 7500 hours of integration time per year for the mission lifetime of about 4 years) will be available to the scientific community at large through a system of refereed proposals. Three basic instruments are located in the SIRTF focal plane. The Multiband Imaging Photometer (MIPS), the Infrared Array Camera (IRAC), and the Infrared Spectrometer (IRS), taken together, provide imaging and spectroscopy from 3.5 to 160 microns. Among the solar system studies suited to SIRTF are the following: 1) spectroscopy and radiometry of small bodies from the asteroid main belt, through the Trojan clouds, to the Kuiper Disk; 2) dust distribution in the zodiacal cloud and the Earth's heliocentric dust ring; 3) spectroscopy and radiometry of comets; and 4) spectroscopy and radiometry of planets and their satellites. Searches for, and studies of dust disks around other stars, brown dwarfs, and superplanets will also be conducted with SIRTF. The SORTIE web site (http://ssc.ipac.caltech.edu/sirtf) contains important details and documentation on the project, the spacecraft, the telescope, instruments, and observing procedures. A community-wide workshop for solar system studies with SIRTF is in the planning stages by the author and Martha S. Hanner for the summer of 1999.

Cruikshank, Dale P.↗

Radiometric Characterization of IKONOS Multispectral Imagery

A radiometric characterization of Space Imaging's IKONOS 4-m multispectral imagery has been performed by a NASA funded team from the John C. Stennis Space Center (SSC), the University of Arizona Remote Sensing Group (UARSG), and South Dakota State University (SDSU). Both intrinsic radiometry and the effects of Space Imaging processing on radiometry were investigated. Relative radiometry was examined with uniform Antarctic and Saharan sites. Absolute radiometric calibration was performed using reflectance-based vicarious calibration methods on several uniform sites imaged by IKONOS, coincident with ground-based surface and atmospheric measurements. Ground-based data and the IKONOS spectral response function served as input to radiative transfer codes to generate a Top-of-Atmosphere radiance estimate. Calibration coefficients derived from each vicarious calibration were combined to generate an IKONOS radiometric gain coefficient for each multispectral band assuming a linear response over the full dynamic range of the instrument. These calibration coefficients were made available to Space Imaging, which subsequently adopted them by updating its initial set of calibration coefficients. IKONOS imagery procured through the NASA Scientific Data Purchase program is processed with or without a Modulation Transfer Function Compensation kernel. The radiometric effects of this kernel on various scene types was also investigated. All imagery characterized was procured through the NASA Scientific Data Purchase program.

Pagnutti, Mary↗

Stennis Space Center Verification and Validation Capabilities

Verification and validation capabilities are discussed for: spatial response,reflectance radiometry, positional accuracy,in-flight instruments, lab calibration, thermal radiometry,hyperspectral radiometry, and portable atmospheric monitoring.

Daehler, Erik↗

Low-noise heterodyne receiver for electron cyclotron emission imaging and microwave imaging reflectometry

The critical component enabling electron cyclotron emission imaging (ECEI) and microwave imaging reflectometry (MIR) to resolve 2D and 3D electron temperature and density perturbations is the heterodyne imaging array that collects and downconverts radiated emission and/or reflected signals (50–150 GHz) to an intermediate frequency (IF) band (e.g. 0.1–18 GHz) that can be transmitted by a shielded coaxial cable for further filtering and detection. New circuitry has been developed for this task, integrating gallium arsenide (GaAs) monolithic microwave integrated circuits (MMICs) mounted on a liquid crystal polymer (LCP) substrate. The improved topology significantly increases electromagnetic shielding from out-of-band interference, leads to 10× improvement in the signal-to-noise ratio, and dramatic cost savings through integration. The current design, optimized for reflectometry and edge radiometry on mid-sized tokamaks, has demonstrated >20 dB conversion gain in upper V-band (60-75 GHz). Implementation of the circuit in a multi-channel electron cyclotron emission imaging (ECEI) array will improve the diagnosis of edge-localized modes and fluctuations of the high-confinement, or H-mode, pedestal.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Millimeter-Wave Thermal Analysis Development and Application to GEN IV Reactor Materials

New millimeter-wave thermal analysis instrumentation has been developed and studied for characterization of materials required for diverse fuel and structural needs in high temperature reactor environments such as the Next Generation Nuclear Plant (NGNP). A two-receiver 137 GHz system with orthogonal polarizations for anisotropic resolution of material properties has been implemented at MIT. The system was tested with graphite and silicon carbide specimens at temperatures up to 1300 ºC inside an electric furnace. The analytic and hardware basis for active millimeter-wave radiometry of reactor materials at high temperature has been established. Real-time, non contact measurement sensitivity to anisotropic surface emissivity and submillimeter surface displacement was demonstrated. The 137 GHz emissivity of reactor grade graphite (NBG17) from SGL Group was found to be low, ~ 5 %, in the 500 – 1200 °C range and increases by a factor of 2 to 4 with small linear grooves simulating fracturing. The low graphite emissivity would make millimeter-wave active radiometry a sensitive diagnostic of graphite changes due to environmentally induced stress fracturing, swelling, or corrosion. The silicon carbide tested from Ortek, Inc. was found to have a much higher emissivity at 137 GHz of ~90% Thin coatings of silicon carbide on reactor grade graphite supplied by SGL Group were found to be mostly transparent to millimeter-waves, increasing the 137 GHz emissivity of the coated reactor grade graphite to about ~14% at 1250 ºC.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Scene correction (precision techniques) of ERTS sensor data using digital image processing techniques

Techniques have been developed, implemented, and evaluated to process ERTS Return Beam Vidicon (RBV) and Multispectral Scanner (MSS) sensor data using digital image processing techniques. The RBV radiometry has been corrected to remove shading effects, and the MSS geometry and radiometry have been corrected to remove internal and external radiometric and geometric errors. The results achieved show that geometric mapping accuracy of about one picture element RMS and two picture elements (maximum) can be achieved by the use of nine ground control points. Radiometric correction of MSS and RBV sensor data has been performed to eliminate striping and shading effects to about one count accuracy. Image processing times on general purpose computers of the IBM 370/145 to 168 class are in the range of 29 to 3.2 minutes per MSS scene (4 bands). Photographic images of the fully corrected and annotated scenes have been generated from the processed data and have demonstrated excellent quality and information extraction potential.

Bernstein, R.↗

Thermal mapping of the lunar surface

A program of lunar infrared radiometry which uses large area scanning is described, and procedures for atmospheric attenuation correction and data reduction to temperature by relative radiometry are outlined. Flow charts of the computer data reduction program are shown which contain the astrometric analysis from ephemeral data. The scan data, taken on 10 evenings in 1971 and 1972 in the 10 to 12 micron window, are presented as isothermal contour maps of the lunar disc. More than 160 areas of anomalous thermal emission were found in the lunar darkside data. Eclipse cooling curves, measured in the same wavelength band for 7 lunar regions during the eclipse of February 10, 1971, are also presented. Errors of the scan and eclipse data were calculated from accuracy estimates of the parameters.

Raine, W. L.↗

Thermal study of the unilluminated surface of the waning moon

A program of lunar infrared radiometry which uses large-area scanning is described. Procedures for atmospheric-attenuation correction and data reduction to temperature by relative radiometry are outlined. The scan data of the waning moon taken during ten evenings in the 10- to 12-micron window are presented as isothermal contour maps of the lunar disk. More than 160 areas of anomalous thermal emission have been found in the lunar dark-side data. These are tabulated and are also shown on an accompanying map. An error analysis, derived from accuracy estimates of the independent parameters, is included.

Raine, W. L.↗