Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “primary control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Parametric study of optical transmission through plasmonic hole arrays modulated by the phase transition of vanadium dioxide

We have performed comprehensive electromagnetic simulations and preliminary experiments to explore the effects of geometrical and material parameters on the extraordinary optical transmission (EOT) through periodic arrays of subwavelength holes in a bilayer stack consisting of a gold or silver film atop a vanadium dioxide film (Au/Ag + VO 2 ), where the latter undergoes a semiconductor-to-metal phase transition. Using the finite-difference time-domain (FDTD) and finite-element methods (FEM), we vary iteratively the array periodicity, VO 2 film thickness and hole diameters, as well as the refractive index inside the VO 2 -layer holes and the VO 2 optical constants. For each variation, we compare the metallic-to-semiconducting ratios of the zero-order transmission ( T 00 ) peaks and find sharp maxima in these ratios within narrow parameter ranges. The maxima arise from Fabry-Perot and Fano-type resonances that minimize T 00 in the semiconducting phase of the perforated bilayers. At a fixed array period, the primary factors controlling the VO 2 -enabled EOT modulation are the VO 2 thickness, diameter of the VO 2 -layer holes, and absorption in the two VO 2 phases. Besides uncovering the origins of the higher metallic-phase T 00 , this study provides a protocol for optimizing the performance of the bilayer hole arrays for potential uses as dynamically tunable nano-optical devices.

Donev, Eugenii U. (ORCID:000000030555219X)↗

Residential Building Energy Efficiency Field Studies: Low-Rise Multifamily

In recent years, the U.S. Department of Energy (DOE) has conducted a series of research studies to validate energy efficient building technologies in the field. Much of the work has focused on single-family construction, and some has also addressed commercial energy codes. The work detailed in this DOE-funded study (EE0007616) focuses on low-rise multifamily buildings (three stories or fewer above grade) in various regions of the United States, and reports on how state-level building codes are being implemented, both in terms of observed characteristics and also in terms of estimated energy impacts. Nearly 100 buildings across four states—Illinois, Minnesota, Oregon, and Washington—were sampled, which represent a range of climate types from mild temperature to very cold continental. Both common entry and outdoor entry buildings were included, and a parallel research project evaluated envelope air tightness and current still-evolving air tightness testing methods. Finally, a set of structured interviews of building designers and other relevant professionals was carried to out to gain more insight into this market. To the greatest extent possible, the methodology developed under the project for low-rise multifamily buildings mirrored the approach established by Pacific Northwest National Laboratory (PNNL) for single-family residential buildings (https://www.energy.gov/eere/buildings/downloads/residential-building-energy-code-field-study). This included the general approach to sampling, recruitment, and data collection, as well as data analysis and presentation. The range of permitting dates for the sites encompassed two energy code cycles in most regions. All states in the study had adopted a variation of the International Energy Conservation Code (IECC) for the structure of their state code. The low-rise multifamily occupancy presents a hybrid building type: most of the building’s conditioned floor area was covered by the residential chapter of the code while portions of the building (such as corridors and common spaces) fell under the commercial code chapter. The key items assessed in this work were: Building Shell—exterior wall insulation, ceiling insulation, foundation insulation, windows. Common Areas—HVAC and lighting. Living Units—lighting, ventilation. A few items were not assessed in detail, given their relative paucity in this occupancy type; these included duct leakage, pipe insulation, and hot water circulation controls. Building characteristics were collected via a combination of architectural, mechanical, electrical, and plumbing plan reviews and field inspections, and entered into a spreadsheet-based tool that was later queried to build a database. Data went through quality control both upon arrival and via a later semi-automated review and assurance process. Most of the data are presented graphically so that the reader can quickly assess compliance with the applicable energy codes (both by state and by code year). As a final step, EnergyPlus™ simulations were created for all buildings in the study to estimate both the as-found energy use intensity (EUI) and the energy and CO 2 that could be saved if features that were found to not meet code minimums were brought up to code. The savings estimates were tabulated for each of the four states in the study. The research team found that the single-family approach was largely applicable to low-rise multifamily buildings. This applies to both the data collection and the prototype EUI analysis. Most of the occupied space is living units and falls under residential energy codes, and many characteristics use similar envelope construction and relatively straightforward mechanical systems and lighting. One of the most challenging aspects of this work was to build an effective spreadsheet-based data collection instrument that could allow efficient collection of both building plan and field data. The research team is of the view that other methods could be equally effective if the work is done carefully with diligent quality control. The primary findings for the work center around the thermal envelope and mechanical systems and lighting at the sites: For thermal envelope components, the majority of buildings met or were better than the prescriptive code.This suggests that building designers and builders are aware of code requirements. In some cases, surveyed buildings were designed to qualify for energy efficiency certification programs. These buildings made up at least 20% of sampled buildings in each state. Almost all buildings met mechanical system efficiency requirements (for both living units and common areas). In some cases, sites employed systems that were considerably more efficient than required by the applicable energy code. Dwelling units had a majority of high-efficacy lighting, often in excess of the state’s residential code requirements. While high-efficacy fixtures were also typical in common areas (corridors and stairwells), lighting power densities (LPDs) in these areas were sometimes higher than levels dictated by the applicable part of the state commercial energy code. The simulation models run on a series of low-rise multifamily prototypes, informed by a composite of the field data collected, calculated annual EUIs of between 20 and 50 kBtu/ft2-yr, with the range representing the effects of both building characteristics and building location (climate zone). A detailed process (based on simulations of prototype buildings) was used to estimate the amount of avoided energy use that would occur if 100% adherence to energy codes were attained. The results indicated modest savings are attainable for items such as window thermal performance and common area lighting. The result is overall only a modest potential for additional energy savings, averaging about 10% of EUI.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

MELCOR Accident Progression and Source Term Demonstration Calculations for a Heat Pipe Reactor

MELCOR is an integrated thermal hydraulics, accident progression, and source term code for reactor safety analysis that has been developed at Sandia National Laboratories for the United States Nuclear Regulatory Commission (NRC) since the early 1980s. Though MELCOR originated as a light water reactor (LWR) code, development and modernization efforts have expanded its application scope to includ e non-LWR reactor concepts. Current MELCOR development efforts include providing the NRC with the analytical capabilities to support regulatory readiness for licensing non-LWR techno logies under Strategy 2 of the NRC?s near- term Implementation Action Plans. Beginning with the Next Generation Nuclear Project (NGNP), MELCOR has undergone a range of enha ncements to provide analytical capabilities for modeling the spectrum of advanced non-LWR concepts. This report describes the generic plant model developed to demonstrate MELCOR capabilities to perform heat pipe reactor (HPR) safety evaluations. The generic plant mode l is based on a publicly-available Los Alamos National Laboratory (LANL) Megapower design as modified in the Idaho National Laboratory (INL) Design A description. For plant aspects (e.g., reactor building size and leak rate) that are not described in the LANL and INL references , the analysts made assumptions needed to construct a MELCOR full-plant model. The HP R uses high assay, low-enrichment uranium (HALEU) fuel with steel cladding that uses heat pipes to transfer heat to a secondary Brayton air cycle. The core region is surrounded by a stainless-steel shroud, alumina reflector, core barrel and boron carbide neutron shield. The reactor is secured inside a below-grade cavity, with the operating floor located above the cavity. Example calculations are performed to show the plant response and MELCOR capabilities to characterize a range of accident conditions. The accidents selected for evaluation consider a range of degraded and failed modes of operation for key safety functions providing re activity control, the primary and secondary system heat removal, and the effectiveness of th e confinement natural circulation flow into the reactor cavity (i.e., a flow blockage).

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Material Property Determinations for Rock Valley Legacy Samples in Support of Source Physics Experiment

The Source Physics Experiment (SPE) is a long-term NNSA research and development effort designed to improve nonproliferation verification and monitoring capabilities. The overarching goals of the SPE program are to improve understanding of prompt signals and physical signatures that develop from underground chemical explosions and associated modeling capabilities. Our work focuses on a primary factor controlling chemical explosion induced signals and signatures: the material properties of the rocks in which the chemical explosion takes place. This document reports on material property determinations of legacy core USGS Test Well F and outcrop analogs for the subsurface stratigraphy for the third phase of SPE in the Rock Valley (RV) area of the Nevada National Security Site (NNSS). The objective of this work is to establish a baseline set of lithologic descriptions and material properties expected prior to observatory borehole drilling in support of the SPE-RVDC (Rock Valley Direct Comparison) experiment. We determine for each rock type the compressional failure envelope, elastic properties as a function of stress (bulk modulus versus mean stress, shear modulus versus shear stress, Young’s modulus versus axial stress and Poisson’s ratio versus axial stress), indirect tensile strength, and porosity. Geologic characterization, both at the core-scale and microscale, provides context for using the data in modeling efforts and to inform interpretations for the material properties testing.

36 MATERIALS SCIENCE↗

Hanford Reach Fall Chinook Salmon Productivity Analysis, Brood Years 1975–2016

Updating the Hanford Reach fall Chinook salmon productivity analysis to include seven additional years of data (BY 2010–2016), including three years of record escapements (>150,000 adults), reaffirmed the highly productive nature of this population and the positive effect of flow fluctuation constraints as implemented at Priest Rapids Dam by the VBSA and HRFCPP. The addition of several years of high escapements also revealed that competition among juveniles (and not spawning habitat limitations) is likely the mechanism driving density dependence in the Hanford Reach. The addition of the high escapement brood years also provided evidence for the high recruitment capacity of the population. As such, the WDFW may consider increasing the maximum escapement goal from 42,000 adults to 49,000 adults, which would be more in-line with SMSY as estimated from this update. Given the in-river protections that are in place as part of the HRFCPP, ocean conditions appear to be the primary factor controlling adult production. Therefore, the success of any additional management actions taken in freshwater are likely to be dependent on survival in the ocean. As such, the most effective management actions may be those that limit juvenile competition and density dependent growth effects in the Hanford Reach. Limiting competition would be expected to increase growth, resulting in larger smolts that would be less likely to suffer size-dependent mortality in the marine environment, even during years of poor ocean conditions. Increasing terminal harvest rates when high escapements are anticipated (from downstream dam counts) is one management option that could help to curtail juvenile competition.

Harnish, Ryan A.↗

Insights on the Effects of Magnetic Forces on the Efficiency of Vibration Energy Harvesting Absorbers in Controlling Dynamical Systems

This study investigates the effects of magnetic constraints on a piezoelectric energy harvesting absorber while simultaneously controlling a primary structure and harnessing energy. An accurate forcing representation of the magnetic force is investigated and developed. A reduced-order model is derived using the Euler–Lagrange principle, and the impact of the magnetic force is evaluated on the absorber’s static position and coupled natural frequency of the energy harvesting absorber and the coupled primary absorber system. The results show that attractive magnet configurations cannot improve the system substantially before pull-in occurs. A rigorous eigenvalue problem analysis is performed on the absorber’s substrate thickness and tip mass to effectively design an energy harvesting absorber for multiple initial gap sizes for the repulsive configurations. Then, the effects of the forcing amplitude on the primary structure absorber are studied and characterized by determining an effective design of the system for a simultaneous reduction in the primary structure’s motion and improvement in the harvester’s efficiency.

42 ENGINEERING↗

Meteorological drivers of the low-cloud radiative feedback pattern effect and its uncertainty

The radiative feedback pattern effect remains a large source of uncertainty for both projections of future trends and interpretations of past trends in global temperature. The pattern effect is defined as the difference in feedbacks between transient and long-term simulations, and past work shows that is primarily attributed to changes in the marine low-cloud radiative feedback. Here we use low cloud meteorological kernels to map out both the primary cloud controlling factors through which changing surface temperature patterns drive changes in low-cloud feedback, as well as the sources of model spread. We find that the pattern effect is almost entirely driven by changes in estimated inversion strength (EIS) in the Southern Hemisphere, particularly in the South East Pacific and Southern Ocean. In both past and future simulations, inter-model spread is primarily caused by model differences in the sensitivity of low clouds to the environmental conditions, rather than differences in the simulated evolution of environmental conditions.

58 GEOSCIENCES↗

Evaluation of an experimental short-length annular combustor: One-side-entry dilution airflow concept

A test program was conducted to evaluate an experimental short-length annular combustor that uses a one-side-entry dilution airflow concept. The combustor design features scoops on the outer liner for controlling the primary- and secondary-zone airflow distribution. Combustor inlet total pressures were limited to 62 N/sq cm (90 psia) with inlet-air temperatures from 590 K (600 F) to 890 K (1150 F). At a diffuser inlet Mach number of 0.25, the exit temperature pattern factor was 0.44 with an average exit temperature of 1436 K (2124 F) and a total pressure loss of 4.3 percent. At a diffuser inlet Mach number of 0.31, the exit temperature pattern factor was reduced to 0.29 with an average exit temperature of 1450 K (2151 F) and a total pressure loss of 6.1 percent. Nominal combustion efficiencies of 100 percent were obtained with the ASTM A-1 fuel. Exhaust gas emissions, smoke, and altitude relight data are included with exit-temperature profiles and distribution patterns.

Humenik, F. M.↗

Active optics simulation system

The active optics simulation system (AOSS) is a set of computer programs and associated software to be used in the development, design, and evaluation of a primary mirror control system for a large space telescope, (e.g., the tentatively proposed 3-meter telescope). The mathematical models of component subsystems and the solution of the physical processes that occur within the mirror surface control system were obtained, and based on these models AOSS simulates the behavior of the entire mirror surface control system as well as the behavior of the component subsystems. The program has a modular structure so that any subsystem module can be replaced or modified with minimum disruption of the rest of the simulation program.

Chi, C. H.↗

SBASI: Actuated pyrotechnic time delay initiator

A precision pyrotechnic time delay initiator for missile staging was developed and tested. Incorporated in the assembly is a single bridgewire Apollo standard initiator (SBASI) for initiation, a through-bulkhead-initiator to provide isolation of the SBASI output from the delay, the pyrotechnic delay, and an output charge. An attempt was made to control both primary and secondary variables affecting functional performance of the delay initiator. Design and functional limit exploration was performed to establish tolerance levels on manufacturing and assembling operations. The test results demonstrate a 2% coefficient of variation at any one temperature and an overall 2.7% coefficient of variation throughout the temperature range of 30 to 120 F. Tests were conducted at simulated operational altitude from sea level to 200,000 feet.

Salter, S. J.↗

Design and preliminary tests of a blade tip air mass injection system for vortex modification and possible noise reduction on a full-scale helicopter rotor

Full-scale tests were conducted on the Langley helicopter rotor test facility as part of a study to evaluate the effectiveness of a turbulent blade tip air mass injection system in alleviating the impulsive noise (blade slap) caused by blade-vortex interaction. Although blade-slap conditions could not be induced during these tests, qualitative results from flow visualization studies using smoke showed that the differential velocity between the jet velocity and the rotor tip speed was a primary parameter controlling the vortex modification.

Pegg, R. J.↗

Low frequency spectra of type III solar radio bursts

Flux density spectra have been determined for 91 simple type III solar bursts observed by the Goddard Space Flight Center radio astronomy experiment on the IMP-6 spacecraft during 1971 and 1972. Spectral peaks were found to occur at frequencies ranging from 44 kHz up to 2500 kHz. Half of the bursts peaked between 250 kHz and 900 kHz, corresponding to emission at solar distances of about 0.3 to 0.1 AU. Maximum burst flux density sometimes exceeds 10 to the -14th W/sq m/Hz. The primary factor controlling the spectral peak frequency of these bursts appears to be a variation in intrinsic power radiated by the source as the exciter moves outward from the sun, rather than radio propagation effects between the source and IMP-6. Thus, a burst spectrum strongly reflects the evolution of the properties of the exciting electron beam, and according to current theory, beam deceleration could help account for the observations.

Weber, R. R.↗

The origin and evolution of sulfur in an Archean volcano-sedimentary basin, Deer Lake area, Minnesota

Rocks of the Deer Lake area, northcentral Minnesota, consist of Archean (age greater than 2.6 billion years) metasediments and metavolcanics intruded by mafic layered sills. Geologic and sulfur isotopic data suggest that sulfides in the sediments are bacteriogenic, having formed in response to the activity of sulfate reducing bacteria during diagenesis. Deposition of the sediments appears to have occurred in a deep marine basin with restricted circulation of sea water. The bulk of the sulfur in the igneous rocks is of deep seated origin, but basal contacts of the sills show evidence of assimilation of biogenic sulfur from the intruded sediments. This assimilation of biogenic sulfur is the primary geochemical control of local Cu-Ni sulfide mineralization.

Nicol, D. L.↗

Proximity operations analysis: Retrieval of the solar maximum mission observatory

Retrieval of the solar maximum mission (SMM) observatory is feasible in terms of orbiter primary reaction control system (PRCS) plume disturbance of the SMM, orbiter propellant consumed, and flight time required. Man-in-loop simulations will be required to validate these operational techniques before the verification process is complete. Candidate approach and flyaround techniques were developed that allow the orbiter to attain the proper alinement with the SMM for clear access to the grapple fixture (GF) prior grappling. Because the SMM has very little control authority (approximately 14.8 pound-foot-seconds in two axes and rate-damped in the third) it is necessary to inhibit all +Z (upfiring) PRCS jets on the orbiter to avoid tumbling the SMM. A profile involving a V-bar approach and an out-of-plane flyaround appears to be the best choice and is recommended at this time. The flyaround technique consists of alining the +X-axes of the two vehicles parallel with each other and then flying the orbiter around the SMM until the GF is in view. The out-of-plane flyaround technique is applicable to any inertially stabilized payload, and, the entire final approach profile could be considered as standard for most retrieval missions.

Yglesias, J. A.↗

Modal content of noise generated by a coaxial jet in a pipe

Measurements of the hydrodynamic pressure fluctuation levels showed that, for circular obstructions with a flow passage diameter less than one-half of the pipe diameter, hydrodynamic pressure fluctuations were small compared with the acoustic pressure, at locations greater than ten pipe diameters downstream of the restrictions. Thus, in the study currently reported, which was concentrated on measurement of the modal characteristics of the sound field downstream of the restrictions, special techniques to avoid contamination by hydrodynamic 'noise' were not necessary. The major results obtained in the study are scaling laws for the shape of the modal pressure spectrum and for the overall efficiency of noise generation. The characteristics of the modal pressure spectra are discussed. It is shown that the primary parameter controlling the spectrum shape is the frequency ratio (Helmholtz number/Strouhal number). The efficiency levels when plotted as a function of Mach number show a strong dependence on restriction size

Kerschen, E. J.↗

Energy coupling between the solar wind and the magnetosphere

A description is given of the path leading to the first approximation expression for the solar wind-magnetosphere energy coupling function (epsilon), which correlates well with the total energy consumption rate (U sub T) of the magnetosphere. It is shown that epsilon is the primary factor controlling the time development of magnetospheric substorms and storms. The finding of this particular expression epsilon indicates how the solar wind couples its energy to the magnetosphere; the solar wind and the magnetosphere make up a dynamo. In fact, the power generated by the dynamo can be identified as epsilon through the use of a dimensional analysis. In addition, the finding of epsilon suggests that the magnetosphere is closer to a directly driven system than to an unloading system which stores the generated energy before converting it to substorm and storm energies. The finding of epsilon and its implications is considered to have significantly advanced and improved the understanding of magnetospheric processes.

Akasofu, S.-I.↗