JTAG-based PLC memory acquisition framework for industrial control systems

In industrial control systems (ICS), programmable logic controllers (PLC) are the embedded devices that directly control and monitor critical industrial infrastructure processes such as nuclear plants and power grid stations. Cyberattacks often target PLCs to sabotage a physical process. A memory forensic analysis of a suspect PLC can answer questions about an attack, including compromised firmware and manipulation of PLC control logic code and I/O devices. Given physical access to a PLC, collecting forensic information from the PLC memory at the hardware-level is risky and challenging. It may cause the PLC to crash or hang since PLCs have proprietary, legacy hardware with heterogeneous architecture. This paper addresses this research problem and proposes a novel JTAG (Joint Test Action Group)-based framework, Kyros, for reliable PLC memory acquisition. Kyros systematically creates a JTAG profile of a PLC through hardware assessment, JTAG pins identification, memory map creation, and optimizing acquisition parameters. It also facilitates the community of interest (such as ICS owners, operators, and vendors) to develop the JTAG profiles of PLCs. Further, we present a case study of Kyros implementation over Allen-Bradley 1756-A10/B to help understand the framework's application on a real-world PLC used in industry settings. The sample PLC memory dumps are shared with the research community to facilitate further research.

Rais, Muhammad Haris↗

Identification of pressure points in modern power systems using transfer entropy

Power shortages disrupt daily life, economic activity, and essential services. In modern power systems, weather is an increasingly important driver of reliability: high temperatures raise demand and limit transmission capacity, and calm or cloudy periods reduce wind and solar supply. Using a data-driven analysis, this study identifies grid infrastructure whose operating patterns help predict power shortages. The results show that reliability risks often emerge from interacting stresses across generation, transmission, and demand, rather than from single bottlenecks. By clarifying how system stress propagates through the grid, this diagnostic perspective helps explain why shortages occur under specific conditions and can complement traditional planning and operational tools to support adaptive reliability strategies, targeted monitoring, and coordinated infrastructure investments.

power systems↗

Introduction to the Special Section on Control and Management of Electric Power Systems With High Shares of Inverter-Based Resources

The growing interest in the integration of variable renewable energy (VRE) and distributed energy resources (DER) on both policy and economic grounds is driving the transformation of electric power systems. The significant deployment of VRE and DER can effectively displace the conventional synchronous generator-based power plants that for decades have been the foundation for power system generation and stability in electric power systems. Inverter-based resources (IBRs) introduce a high-level of uncertainty, variability, and complexity into the operation of electric power networks, and the transformation to IBRs raises a wide range of technical questions and operational challenges. The optimal coordination and control of these resources requires greater interoperability and necessitates significant upgrades of grid automation, including real-time monitoring.

distributed power generation↗

Integration of a DER Management System in Riverside. Final report

The tasks in this project covered various aspects, including algorithm development, algorithm integration into a commercial Active Network Management (ANM) platform, hardware-in-the-loop (HIL) testing in an industry-standard testing platform, pilot demonstration in Riverside, California, and also cost and benefit analysis. The DERMS platform in this project can host different algorithms developed on different platforms (e.g., MATLAB and Python) and it can interact with different hardware devices (e.g., different PV inverters, battery inverters, and different sensors). The DER control solution are based on an advanced model-free, layered, and clustered DER control paradigm. At the core of the DER control algorithms was the concept of Extremum Seeking (ES), which is a model-free probing-based control technique. The ES-based control algorithms were tested on major real-world inverters; both individually and in a cluster. It was shown that even legacy equipment (or when paired with a few additional advanced equipment) can support such advanced control. The monitoring algorithms utilize a heterogeneous set of legacy and advanced sensor measurements, such as behind-the-meter DER sensors, distribution-level Phase Measurement Units, distribution-substation Supervisory Control and Data Acquisition (SCADA), and line current sensors, with their limited availability; in order to infer practical network conditions. Sensor data are utilized to achieve resource forecasting, phase identification, and distribution system state estimation. The technology that was developed and demonstrated in this project could be transformational to utilities, including the smaller municipal utilities such as in Riverside, which may not have the resources to deploy advanced distribution system and DERMS solutions in order to support high penetration of solar power integration. This project created a real-world prototype to provide utilities with an assessment of smart grid monitoring and control technologies.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Analytics-at-scale of Sensor Data for Digital Monitoring in Nuclear Plants (4th Annual Report)

Nuclear plant sites collect and store large volumes of data collected from various equipment and systems. These datasets typically include plant process parameters, maintenance records, technical logs, online monitoring data, and equipment failure data. The collection of such data affords an opportunity to leverage data-driven machine learning and artificial intelligence technologies to provide diagnostic and prognostic capabilities within the nuclear power industry to reduce operating and maintenance costs. In this way, nuclear energy can become more economically competitive with other energy sources, and premature closures can be avoided. From a maintenance standpoint, savings can be achieved by leveraging machine learning and artificial intelligence technologies to develop data-driven algorithms to better diagnose and predict potential faults within the system. Improved model accuracy can lead to reductions in unnecessary maintenance and more efficient planning of future maintenance, thus lowering the costs associated with parts, labor, and unnecessary planned, forced, or extended outages. From an operations perspective, cost savings can be generated by shifting from route-based monitoring to wireless technologies for online monitoring, and by transitioning from onsite- to cloud-based computing and storage services. Wireless monitoring would reduce the operator manhours required for taking routine measurements, while cloud computing services would generate cost savings by reducing the amount of hardware needing to be purchased and maintained—all while scaling to both computational and storage demands. This report summarizes this project’s effort to shift from costly, labor-intensive preventative maintenance to cheaper predictive maintenance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design of a Time-to-Digital Converter ASIC and a mini-DAQ system for the Phase-2 upgrade of the ATLAS Monitored Drift Tube detector

We present the second prototype of a time-to-digital (TDC) ASIC for the upgrade of the ATLAS Monitored Drift Tube (MDT) detector for High-Luminosity LHC operations. Compared to the first prototype, triple modular redundancy has been implemented for the configuration and flow control logic. Here, the total power consumption is increased by less than 10 mW while achieving the same time resolution and channel uniformity. A mini-DAQ system has been built to verify the front-end electronics chain with the new prototype together with other ASICs and boards in triggered mode. Cosmic ray tests with a small-diameter MDT chamber indicate that the configuration and data transmission of the readout electronics perform well. It is expected that this prototype design will be used in the final production.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Cybersecurity for Distance Relay Protection

This project is a DOE follow-up effort on the CREDC workshop held on September 13, 2018 in Cambridge, MA to discuss cybersecurity of distance relays, which considered the benefits, vulnerabilities and risk mitigations for the use of communication systems in power system protection. The objectives of this project are to define the taxonomy of relay protection and associated communications; define use cases describing approaches to reduce the cyber-attack surface on those protective relays; and evaluate the loss of operational functional capability from changes to communication coverage. Mitigating controls will also be evaluated to understand if there are other approaches to reduce attack surfaces while maintaining communications or partial communications. Distance relays are used to protect transmission lines of approximately 10 to 300 miles in length, by detecting short circuits (i.e., faults) on the lines and then tripping circuit breakers in the substation. Such protection systems are a subset of the power system and they incorporate sensing, logic and communication functions. Protection system exposure to cyberattack could be drastically limited by disconnecting relays from all vulnerable communication systems, but this may adversely impact overall power system performance in the absence of cyberattack. This project began with a use case analysis of protection systems with communications, as summarized in this report. It continued with modeling, testing and evaluation in a miniature power system (MPS), located in the Western Area Power Administration (WAPA) Electric Power Training Center (EPTC). The project also incorporated feedback from two industry meetings held in February and September 2019. The suggested next steps account for and complement the work already underway with DOE/CESER funding: 1. Study the performance of LCD and PC vs. PUTT, which is less reliant on communication system performance and GPS timing references. The PUTT scheme could prove to be more resilient to cyberattack or communications-related disruption. It could also be more tolerant of message re-routing with SDN/SDR communication systems. On the other hand, it will be more vulnerable to false tripping during dynamic events or to loss of the voltage signal. The optimum choice of scheme may depend on the specific power system and risk assessment. This study could provide a new template for evaluation based on business functions. 2. Research and develop new methods to detect and monitor distributed physical attacks, possibly using drones, video sensors, thermal sensors, machine learning and other advanced techniques. This will help mitigate the impact of cyberattack on the protection system, and will also help mitigate the impact of wild fires. 3. Implement a scalable PKI for use in electric utility protection systems. This will encourage widespread adoption of secure authentication methods that are already available, but not widely used at present. This will help secure engineering access to the relays. 4. Investigate the use of SDN in combination with SDR to achieve better cybersecurity and electromagnetic security of the network, incorporating path variability. This would help secure both engineering access and peer-to-peer GOOSE messaging. 5. Perform additional testing, with operator evaluation of “red button” scenarios, PUTT vs. LCD, relay mis-operations, and other cyberattacks in the EPTC. This is an important advantage of testing in the EPTC rather than by computer simulation or even hardware-in-the-loop simulation; the EPTC is already dedicated to managing the situational awareness, operator response times and other human impacts. One of the project objectives was to settle on a common nomenclature for this problem space. We have concluded that the OSI layer model, supplemented by ANSI device numbers and other IEEE standards, is already well-accepted by the industry. The IEEE PSRC knowledge base provides a great deal of public information

24 POWER TRANSMISSION AND DISTRIBUTION↗

Avian Activity Classification Using Recurrent Networks to Fuse Videos with Metadata on Imbalanced Datasets

Activity classification plays a crucial role in various real-life scenarios involving both humans and animals. There is an increasing need for precise activity classification focused on avian-solar interactions, as the usage of solar energy facilities, such as photovoltaic array power stations, has been observed to impact bird species richness, behavior, and activity. However, there has been no work to develop an automated system to monitor and classify these avian-solar interactions. All current methods rely on human observers, which is time and human resources costly and subject to errors related to searcher efficiency. With the recent success of Deep Learning models in activity classification problems, this paper develops a recurrent neural network-based model to automatically classify six avian activities around solar energy facilities. Our proposed model integrates critical feature engineering metadata with video frame data, enabling improved learning and more accurate activity classification. Furthermore, we address the challenge of data imbalance during training and demonstrate the efficacy of our model in detecting and classifying different activities within video tracks. Additionally, we analyze the saliency/backpropagation map of the trained proposed model and validate its decision-making rationale.

Avian activity classification; bidirectional LSTM;↗

ALFA Field Testing of a Dual Sonar System for Detecting Woody Debris

Field testing of a dual sonar system for detecting woody debris in natural settings was conducted at the Tanana River Test Site (TRTS) in Nenana, AK between 8/26 and 9/23, 2015. The TRTS is approximately 65 miles south of Fairbanks and is well suited for testing hydrokinetic energy generation technologies and environmental monitoring technologies such as the dual sonar system used here in realistic settings.

16 TIDAL AND WAVE POWER↗

Evaluation of the Nanometrics Centaur Digitizer

Sandia National Laboratories has tested and evaluated a new digitizer, the Centaur, manufactured by Nanometrics, Inc. This digitizer is used to record sensor output for seismic and infrasound monitoring applications. The purpose of the digitizer evaluation was to measure the performance characteristics in such areas as power, sensitivity, self-noise, dynamic range, system noise, modified noise power ration, relative transfer function, analog bandwidth, harmonic distortion, common mode, cross talk, timing tag accuracy and timing drift. The Centaur provides six channels of 24 bit digitization, three of which may be transmitted utilizing CD1.1 protocol.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

NERC MISOPS

This investigation was commissioned by the Office of Electricity of the Department of Energy in response to reviewing the NERC State of Reliability report. The study is an attempt to proactively address electric utility industry needs. “Monitoring, analyzing, and tracking trends in Protection System Misoperations are critical to improve BES reliability. Historically, Protection System Misoperations have exacerbated the severity of most cascading power outages.” The NERC misoperations data shows that unnecessary trips are by far the leading category of reported misoperations and that a majority of misoperations are those of line protection packages. A significant number of misoperations are tied to microprocessor relays. Approximately one quarter of reported misoperations are due to incorrect settings and another one quarter of misoperations are due to relay failures/malfunctions and communication failures.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Steam Generators: Thermal Hydraulic Measurements and Instrumentation

Steam generators are integral components of both conventional and advanced reactors utilizing steam power cycles, as they influence the power conversion performance. Steam generator designs are highly influenced by the type of reactor coolant used, which mainly governs the different control, monitoring, and safety system actuation requirements. Therefore, the present work reviews the thermal hydraulics instrumentation within steam generators designed for pressurized water reactors (PWRs), high-temperature gas-cooled reactors (HTGRs), sodium fast reactors (SFRs), and molten salt cooled reactors (MSRs). Emphasis is given to measurement techniques that are either unique or particularly important to specific reactor types. Lastly, a discussion is provided on the instrumentation and measured parameters. The work identifies standard parameters of interest and is expected to aid the development of test beds and novel measurements techniques.

21 - SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLAN↗

Photovoltaic System Health-State Architecture for Data-Driven Failure Detection

The timely detection of photovoltaic (PV) system failures is important for maintaining optimal performance and lifetime reliability. A main challenge remains the lack of a unified health-state architecture for the uninterrupted monitoring and predictive performance of PV systems. To this end, existing failure detection models are strongly dependent on the availability and quality of site-specific historic data. The scope of this work is to address these fundamental challenges by presenting a health-state architecture for advanced PV system monitoring. The proposed architecture comprises of a machine learning model for PV performance modeling and accurate failure diagnosis. The predictive model is optimally trained on low amounts of on-site data using minimal features and coupled to functional routines for data quality verification, whereas the classifier is trained under an enhanced supervised learning regime. The results demonstrated high accuracies for the implemented predictive model, exhibiting normalized root mean square errors lower than 3.40% even when trained with low data shares. The classification results provided evidence that fault conditions can be detected with a sensitivity of 83.91% for synthetic power-loss events (power reduction of 5%) and of 97.99% for field-emulated failures in the test-bench PV system. Finally, this work provides insights on how to construct an accurate PV system with predictive and classification models for the timely detection of faults and uninterrupted monitoring of PV systems, regardless of historic data availability and quality. Such guidelines and insights on the development of accurate health-state architectures for PV plants can have positive implications in operation and maintenance and monitoring strategies, thus improving the system’s performance.

photovoltaics↗

Technical Performance and Cost Optimization of Unobtrusive Multi-static Serial LiDAR Imager (UMSLI) for Wide-area Surveillance and Identification of Marine Life at Marine Energy Installations

Florida Atlantic University developed an underwater optical monitoring system prototype - Unobtrusive Multi-static Serial LiDAR Imager (UMSLI) - suitable for marine energy full project lifecycle observation (baseline, commissioning, and decommissioning), with an automated real-time classification of marine animals. With precursor 2014 DOE funding (award DE-EE0006787), a prototype UMSLI was demonstrated in a controlled laboratory environment and achieved a TRL 6. This EERE DE-EE0007828 award aimed to both increase the TRL of the UMSLI by improving the technology performance (e.g., increase distance of marine animal target detection capability, add additional species classification capabilities, improve the system performance during the day, etc.) and reduce the cost. The UMSLI presents a novel application of underwater distributed Light Detection And Ranging (LiDAR), an advanced remote sensing method that uses light in the form of laser pulses for an application, this paired with an algorithm provides 360 degrees underwater detection, imaging, and classification of marine life. This solution for underwater monitoring of biota preserves the advantages of traditional optical and acoustic solutions while overcoming many associated disadvantages for marine energy site environmental monitoring, such as difficulties in species detection and classification in low light or night and turbid environments. This new approach is a purposefully designed, reconfigurable adaptation of an existing class 3B laser technology into one UMSLI instrument that can be easily mounted on or around different classes of marine energy equipment, such as devices to capture ocean current energy or wave energy. The system uses relatively low average power, utilizes far-red (> 635nm) laser illumination to be invisible and eye-safe to marine animals, is compact, and cost-effective. The equipment is designed for long-term, maintenance-free operations (i.e., current design is targeting more than 7 days continuous operation), to inherently generate a sparse primary dataset that only includes detected anomalies, and to allow robust real-time automated animal classification and identification with a low data bandwidth requirement. The technology’s overarching goal for application, is a system that can be deployed to collect pre-installation baseline species observations at a proposed marine energy deployment site with minimal post-processing overhead. The envisioned system will also produce high-resolution imagery of marine animals through a wide range of conditions and support automated tracking and notification of the presence of managed animals within established perimeters of marine energy equipment to satisfy deployed marine energy projects’ endangered and threatened species monitoring requirements. Through the current project, we demonstrated the UMSLI prototype in an operational environment and increased the UMSLI’s Technology Readiness Level from 6 to 7. The project resulted in many novel technologies, including: 1) an eye-safe red laser based, low-cost LiDAR system that can detect targets up to 10 meters distance; 2) the GAN-based machine learning underwater LiDAR image enhancement technique (this is the first known application of GAN technique in underwater LiDAR); 3) LiDAR-based real-time automated detection capabilities; and 4) a template matching based automated classification tool. These technologies build a solid foundation for future efforts to develop an extended range electro-optical monitoring system suitable for marine energy deployments. In addition to technology development, a key lesson learned is that addressing regulatory and safety requirements must be front and center in any marine energy monitoring applications.

16 TIDAL AND WAVE POWER↗

Ibis Networks/WattIQ (IN2 Final Report)

Ibis Networks is a full-stack cleantech company that provides plug-level energy monitoring and control to solve energy and asset management problems for the enterprise. During DATES – DATES, an NREL research team worked with the Ibis team to validate their product, the InteliSocket. The Ibis InteliSocket is a pass-through plug-load energy monitor and controller that is designed to reduce energy wasted by common 120 V plug-in devices in commercial office buildings, such as computer peripherals, conference room AV equipment, and break-room appliances. The system can shut off supply power to these end uses via remote control, manual switches, pre-set schedules, or automated control algorithms. The scope of this IN2 project was the development and refinement of “smart” learning behavior algorithms (LBAs), which could help installation processes and dramatically expand the sockets’ capabilities and energy-saving potential by suggesting suitable control schedules that are based on monitored use patterns. While Ibis has the analytical and software expertise for algorithm development, the lack of test data, both in a controlled laboratory setting and in real-life deployment scenarios, represented a key barrier toward commercialization of the product. Assistance through the IN2 program provided an opportunity to conduct the needed “trial and error” algorithm development. The project included baseline field-data collection, laboratory testing, and field validation components, all of which were conducted at the NREL campus between April 2017 and July 2019.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Initial Refinement and Optimization of the Image Reconstruction (U-MBIR) Algorithm to Optimize its Performance in Detecting Damage and Flaws

Concrete is a critical component of nuclear power plants; thus, its safety and reliability must be thoroughly examined throughout the life cycle of the structural system. During the life cycle of this infrastructure, monitoring of the concrete for signs of degradation should be performed through nondestructive evaluation (NDE). Ultrasonic measurements have been an industry standard for both surface and subsurface inspections. As such, Oak Ridge National Laboratory (ORNL) is developing advanced image reconstruction algorithms to overcome the limitations of traditional ultrasonic NDE methodologies. The results and discussion presented herein summarize the current state of the ultrasonic model–based iterative reconstruction (U-MBIR) algorithm developed at ORNL.

36 MATERIALS SCIENCE↗

Digital Assurance for Grid Reliability in the Era of Large Load Growth

The rapid expansion of large electric loads is reshaping the operational and regulatory landscape of the U.S. electric grid. These facilities are reaching new scales of expansion, now exceeding a gigawatt per site, and their highly sensitive, digitally driven behaviors introduce new reliability risks. Recent grid events, including large load losses following routine transmission disturbances, highlight the consequences of limited ride-through capability, inconsistent protection settings, inadequate modeling, and lack of behind-the-meter visibility. Parallels to earlier integration challenges of new grid technologies suggest that the grid’s existing processes, standards, and interconnection frameworks are no longer adequate for emerging large loads. This brief synthesizes lessons from the evolution of inverter-based resource regulation and applies them to large-load integration. It identifies critical gaps in modeling accuracy, interconnection processes, performance standards, and compliance mechanisms. Technical recommendations emphasize advanced monitoring, improved modeling, coordinated communication protocols, modernized substations, and structured behind-the-meter control schemes. Collectively, these measures provide a roadmap to maintain bulk power system reliability while enabling the continued growth of large, electrified digital infrastructure.

24 - POWER TRANSMISSION AND DISTRIBUTION↗