Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “power system monitoring”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Consort 3 flight experiments

The third sounding rocket payload in the Consort program was launched from the White Sands Missile Range on May 16, 1990. It carried 12 experiments designed to investigate materials processes in low gravity. All of the experiments were reflights from the Consort 2 payload that was launched on November 1989 but failed to achieve microgravity because of a malfunction in the launch vehicle. Four national Centers for the Commercial Development of Space participated in the mission. The payload included five experiments and two accelerometer systems that flew on Consort 1 and seven new experiments, designed and developed since Consort 1. Experiments from Consort 1 incorporated hardware modifications and changes in experimental parameters based on mission results. The new experiments covered a variety of polymeric and biological investigations. A new power distribution and control system designed to provide discrete, computer-supervised, experiment power monitoring and control was flight qualified on Consort 3. Consort 3 featured very late access (3-5 h before launch vs 27-30 h for Consort 1) for installation of sensitive biological specimens. The integrated payload and mission sequence of events are described. Changes in the Consort 1 experiments are defined and the objectives, methods, and expectations for new experiments are discussed.

Wessling, Francis C.↗

Person-Locator System Based On Wristband Radio Transponders

Computerized system based on wristband radio frequency (RF), passive transponders is being developed for use in real-time tracking of individuals in custodial institutions like prisons and mental hospitals. Includes monitoring system that contains central computer connected to low-power, high-frequency central transceiver. Transceiver connected to miniature transceiver nodes mounted unobtrusively at known locations throughout the institution. Wristband transponders embedded in common hospital wristbands. Wristbands tamperproof: each contains embedded wire loop which, when broken or torn off and discarded, causes wristband to disappear from system, thus causing alarm. Individuals could be located in a timely fashion at relatively low cost.

Mintz, Frederick W.↗

Wheel speed management control system for spacecraft

A spacecraft attitude control system uses at least four reaction wheels. In order to minimize reaction wheel speed and therefore power, a wheel speed management system is provided. The management system monitors the wheel speeds and generates a wheel speed error vector. The error vector is integrated, and the error vector and its integral are combined to form a correction vector. The correction vector is summed with the attitude control torque command signals for driving the reaction wheels.

Goodzeit, Neil E.↗

Multiplexer/Demultiplexer Loading Tool (MDMLT)

The purpose of the MDMLT is to improve the reliability and speed of loading multiplexers/demultiplexers (MDMs) in the Software Development and Integration Laboratory (SDIL) by automating the configuration management (CM) of the loads in the MDMs, automating the loading procedure, and providing the capability to load multiple or all MDMs concurrently. This loading may be accomplished in parallel, or single MDMs (remote). The MDMLT is a Web-based tool that is capable of loading the entire International Space Station (ISS) MDM configuration in parallel. It is able to load Flight Equivalent Units (FEUs), enhanced, standard, and prototype MDMs as well as both EEPROM (Electrically Erasable Programmable Read-Only Memory) and SSMMU (Solid State Mass Memory Unit) (MASS Memory). This software has extensive configuration management to track loading history, and the performance improvement means of loading the entire ISS MDM configuration of 49 MDMs in approximately 30 minutes, as opposed to 36 hours, which is what it took previously utilizing the flight method of S-Band uplink. The laptop version recently added to the MDMLT suite allows remote lab loading with the CM of information entered into a common database when it is reconnected to the network. This allows the program to reconfigure the test rigs quickly between shifts, allowing the lab to support a variety of onboard configurations during a single day, based on upcoming or current missions. The MDMLT Computer Software Configuration Item (CSCI) supports a Web-based command and control interface to the user. An interface to the SDIL File Transfer Protocol (FTP) server is supported to import Integrated Flight Loads (IFLs) and Internal Product Release Notes (IPRNs) into the database. An interface to the Monitor and Control System (MCS) is supported to control the power state, and to enable or disable the debug port of the MDMs to be loaded. Two direct interfaces to the MDM are supported: a serial interface (debug port) to receive MDM memory dump data and the calculated checksum, and the Small Computer System Interface (SCSI) to transfer load files to MDMs with hard disks. File transfer from the MDM Loading Tool to EEPROM within the MDM is performed via the MILSTD- 1553 bus, making use of the Real- Time Input/Output Processors (RTIOP) when using the rig-based MDMLT, and via a bus box when using the laptop MDMLT. The bus box is a cost-effective alternative to PC-1553 cards for the laptop. It is noted that this system can be modified and adapted to any avionic laboratory for spacecraft computer loading, ship avionics, or aircraft avionics where multiple configurations and strong configuration management of software/firmware loads are required.

Brewer, Lenox Allen↗

Planetary Lake Lander - A Robotic Sentinel to Monitor a Remote Lake

The Planetary Lake Lander Project is studying the impact of rapid deglaciation at a high altitude alpine lake in the Andes, where disrupted environmental, physical, chemical, and biological cycles result in newly emerging natural patterns. The solar powered Lake Lander robot is designed to monitor the lake system and characterize both baseline characteristics and impacts of disturbance events such as storms and landslides. Lake Lander must use an onboard adaptive science-on-the-fly approach to return relevant data about these events to mission control without exceeding limited energy and bandwidth resources. Lake Lander carries weather sensors, cameras and a sonde that is winched up and down the water column to monitor temperature, dissolved oxygen, turbidity and other water quality parameters. Data from Lake Lander is returned via satellite and distributed to an international team of scientists via web-based ground data systems. Here, we describe the Lake Lander Project scientific goals, hardware design, ground data systems, and preliminary data from 2011. The adaptive science-on-the-fly system will be described in future papers.

Pedersen, Liam↗

Thin Film Sensors for Fission Surface Power

Physical sensors fabricated with thin films could result a significant savings in space and weight with improved reliability for monitoring the long-term operation of fission surface power systems. Thin film sensors of 1 µm or less are attractive for FSP applications because they can be incorporated onto component surfaces with minimal machining and the additional weight to a system is minimal compared to thick film-, wire-, or foil-based sensors. The thin, surface fabrication of the sensors is also expected to make them less susceptible to deep dose effects that affect thicker sensors. An overview of thin film sensors using thermocouples and resistive elements designed, fabricated, and demonstrated at GRC for aerospace applications exceeding 900°C is presented.

Fission Surface Power↗

A Thermal Survey Instrument Using LSI Data Storage

This paper describes a developmental system for monitoring the temperature of lakes and rivers. The battery powered instrument is housed in a buoy and requires no external electrical connections. Temperature is periodically sampled and stored in LSI shift register circuits. Depending on the type of data reduction used, storage times from days to weeks are possible. The measurement range is from 0 C to 50 C with an accuracy of +/- 0.1 c. This is accomplished using a novel temperature sensitive C/MOS oscillator together with off-line computer linearization. The electronics is partitioned for eventual C/MOS LSI implementation which should result in a total cost of under $1,000 for the system.

Lathrop. Jay W.↗

FNET/GridEye: A Tool for Situational Awareness of Large Power Interconnetion Grids

This paper gives an overview of a wide-area measurement system deployed at the distribution level: FNET/GridEye, which consists of hundreds of sensors, communication and a data center. The sensors are utilized to take frequency, voltage phase angle and magnitude measurements from the ordinary 110 or 220V outlets in offices or residential houses. These measurements are continuously transmitted to the data center via Internet. Many applications have been implemented to monitor large-scale interconnected power grids, and interpret grid operation status to improve system operators' situational awareness capability. Some representative online and offline applications are presented in this paper, as well as several recently developed new applications.

Zhu, Lin↗

Precise synchronization of phasor measurements in electric power systems

Phasors representing positive sequence voltages and currents in a power network are in the most important parameters in several monitoring, control, and protection functions in interconnected electric power networks. Recent advances in computer relaying have led to very efficient and accurate phasor measurement systems. When the phasors to be measured are separated by hundreds of miles, it becomes necessary to synchronize the measurement processes, so that a consistent description of the state of the power system can be established. Global Positioning System (GPS) transmissions offer an ideal source for synchronization of phasor measurements. The concept and implementation of this technique are described. Several uses of synchronized phasor measurements are also described. Among these are improved state estimation algorithms, state estimator enhancements, dynamic state estimates, improved control techniques, and improved protection concepts.

Phadke, Arun G.↗

Evaluation of uncertainty in antineutrino spectra normalization calculations for advanced nuclear reactor monitoring

Antineutrino detection systems have been envisioned as an important aspect of safeguarding the next generation of nuclear reactors, especially considering designs utilizing exotic fuel cycles. Deployment of antineutrino detection systems for safeguarding applications is hindered by the uncertainties associated with the calculations required for antineutrino spectra measurements and predictions. The focus of this work is to assess the impact of system components on antineutrino spectra normalization uncertainties and their significance in reactor power monitoring sensitivity. The dominant limitation in antineutrino detection calculations is typically the uncertainty associated with a cosmogenic background. This limitation becomes more pronounced when signals are weak, although the issue is mitigated in larger reactors due to their stronger source strength. Additionally, antineutrino emission uncertainties vary with the isotopic composition of the reactor fuel. Unconventional fuel cycles, featuring less common fissioning isotopes, such as Pu-240, introduce larger antineutrino yield uncertainties. The findings from this study suggest that future research on safeguard-targeted antineutrino detection should prioritize background mitigation, particularly when background simulation is necessary. Advanced nuclear reactor designs have a major influence on background understanding and successful system implementation.

Physics↗

Heartbeat: Detecting Malware by Periodic Power Signal Injection and Monitoring

Rootkits and other stealthy malware attempt to conceal their presence on a computer by making changes to the host computer’s operating environment. ORNL’s Heartbeat technology detects these changes, and thus the malware itself. Heartbeat operates by directly monitoring the DC power consumption of the computer while a set of operations, the “heartbeat,” is executed periodically. These operations exercise parts of the operating system that are common targets of malware tampering. The power consumption during these heartbeat events is monitored and then compared to a previously learned baseline, with any significant deviation detected and analyzed. This technology has been tested and validated in a laboratory environment, and ORNL is currently seeking a deployment partner to allow for further in-context development and testing of this technology.

97 MATHEMATICS AND COMPUTING↗

Cyber Secure Sensor Network for Fossil Fuel Power Generation Assets Monitoring

The energy sector is undergoing digital transformation which is to say more and more power generation assets have become automated and connected to the internet. The connected sensors can tap into plants to monitor the health of assets and manage fleets remotely. These are just some of the benefits digitalization is bringing to the power industry. Within a power plant, control systems are no longer concerned with one system or one piece of equipment, but rather whole fleet of assets inter-connected with smart sensors which have the function of continuously monitoring and transmitting real-time operational data to operators. These connected systems will form a part of the industrial internet of things (IIoT). The big data scenarios provide benefits of performing system prognostics and optimization which is a key selling point of power plant digitalization.

20 FOSSIL-FUELED POWER PLANTS↗

A Multi-Purpose Modular Electronics Integration Node for Exploration Extravehicular Activity

As NASA works to develop an effective integrated portable life support system design for exploration Extravehicular activity (EVA), alternatives to the current system s electrical power and control architecture are needed to support new requirements for flexibility, maintainability, reliability, and reduced mass and volume. Experience with the current Extravehicular Mobility Unit (EMU) has demonstrated that the current architecture, based in a central power supply, monitoring and control unit, with dedicated analog wiring harness connections to active components in the system has a significant impact on system packaging and seriously constrains design flexibility in adapting to component obsolescence and changing system needs over time. An alternative architecture based in the use of a digital data bus offers possible wiring harness and system power savings, but risks significant penalties in component complexity and cost. A hybrid architecture that relies on a set of electronic and power interface nodes serving functional models within the Portable Life Support System (PLSS) is proposed to minimize both packaging and component level penalties. A common interface node hardware design can further reduce penalties by reducing the nonrecurring development costs, making miniaturization more practical, maximizing opportunities for maturation and reliability growth, providing enhanced fault tolerance, and providing stable design interfaces for system components and a central control. Adaptation to varying specific module requirements can be achieved with modest changes in firmware code within the module. A preliminary design effort has developed a common set of hardware interface requirements and functional capabilities for such a node based on anticipated modules comprising an exploration PLSS, and a prototype node has been designed assembled, programmed, and tested. One instance of such a node has been adapted to support testing the swingbed carbon dioxide and humidity control element in NASA s advanced PLSS 2.0 test article. This paper will describe the common interface node design concept, results of the prototype development and test effort, and plans for use in NASA PLSS 2.0 integrated tests.

Hodgson, Edward↗

A pulsed CO2 Doppler lidar for boundary layer monitoring

A monostatic, master oscillator power amplifier (MOPA), CO2 pulsed Doppler lidar was constructed and tested. The system is compact (120 x 60 cm), operates at high pulse repetition rates (greater than 1 kHz) and is intended for simultaneous Doppler/Differential Absorption Lidar (DIAL) monitoring of the planetary boundary layer. Details of the system design, hard target calibrations, and aerosol returns are presented.

Pearson, Guy N.↗

Toward the Instrumentation and Data Acquisition of a Tidal Turbine in Real Site Conditions

The National Renewable Energy Laboratory manufactured, instrumented, and deployed thermoplastic composite blades and a data acquisition system (NDAQ) on one of Verdant Power’s Gen5d 5 m diameter tidal turbines in New York’s East River. The thermoplastic blades had internal strain gages, and the NDAQ was a stand-alone system for monitoring and recording the strain and angular position of the blades. The turbine with thermoplastic blades operated and produced power successfully for 3 months, contributing energy to the New York City electric grid. The NDAQ hardware, instrumentation, and structure all survived the deployment and were still functional upon retrieval of the system, but no data were collected. Even though the data retrieval was not a success, data acquisition for deployed subsea marine renewable structures is a new undertaking, and it is critical to share lessons learned from national laboratory experiences. The successful deployment of thermoplastic composite blades marks a significant advancement toward improved materials for subsea components, as well as an advancement in recyclable composite materials. This article outlines the methodology and lessons learned for the instrumentation and data acquisition system.

16 TIDAL AND WAVE POWER↗

Arc burst pattern analysis fault detection system

A method and apparatus are provided for detecting an arcing fault on a power line carrying a load current. Parameters indicative of power flow and possible fault events on the line, such as voltage and load current, are monitored and analyzed for an arc burst pattern exhibited by arcing faults in a power system. These arcing faults are detected by identifying bursts of each half-cycle of the fundamental current. Bursts occurring at or near a voltage peak indicate arcing on that phase. Once a faulted phase line is identified, a comparison of the current and voltage reveals whether the fault is located in a downstream direction of power flow toward customers, or upstream toward a generation station. If the fault is located downstream, the line is de-energized, and if located upstream, the line may remain energized to prevent unnecessary power outages.

Russell, B. Don↗

Arctic Deployment of a Fully Integrated Self-Powered Drifting Buoy Harvesting Wave Energy via a Triboelectric Nanogenerator

The Arctic Ocean remains one of the most poorly sampled regions on Earth, where improved in situ environmental monitoring is vital for advancing oceanographic and atmospheric studies. However, data collection efforts are constrained by the short operational lifespans and high costs of conventional systems. Drifting buoys powered by pendulum-driven wave energy harvesters offer a cost-effective alternative, yet earlier designs have neither been optimized for real-world wave conditions nor validated in the Arctic. In this study, we develop a self-powered drifting buoy that integrates a pendulum-driven triboelectric nanogenerator (TENG) system with a mechanical motion rectifier, a high-gear-ratio transmission, and power management circuits. Through coupled buoy–pendulum dynamic simulations and laboratory testing using a motion simulator, we identify an optimal pendulum mass of 1.6 kg (12.7% of total buoy weight) that maximizes energy output while maintaining buoy stability. Laboratory experiments achieved average power outputs of 12.7 mW under Arctic-like wave and temperature conditions. The system was successfully deployed in the Bering Sea, where it generated 11 J of energy in 3.1 m waves, marking the first Arctic deployment of a TENG-based drifting buoy for sea surface temperature monitoring. This work establishes a cost-effective framework for designing self-powered Arctic monitoring platforms and advances the feasibility of long-term environmental observations in real Arctic waters.

marine enerby↗

1985 Nuclear Science Symposium, 32nd, and 1985 Symposium on Nuclear Power Systems, 17th, San Francisco, CA, October 23-25, 1985, Proceedings

The present conference ranges over topics in high energy physics instrumentation, detectors, nuclear medical applications, health physics and environmental monitoring, reactor instrumentation, nuclear spacecraft instrumentation, the 'Fastbus' data acquisition system, circuits and systems for nuclear research facilities, and the development status of nuclear power systems. Specific attention is given to CCD high precision detectors, a drift chamber preamplifier, a Cerenkov ring imaging detector, novel scintillation glasses and scintillating fibers, a modular multidrift vertex detector, radial wire drift chambers, liquid argon polarimeters, a multianode photomultiplier, the reliability of planar silicon detectors, the design and manufacture of wedge and strip anodes, ultrafast triode photodetectors, photomultiplier tubes, a barium fluoride plastic scintillator, a fine grained neutron hodoscope, the stability of low leakage silicon photodiodes for crystal calorimeters, and X-ray proportional counters. Also considered are positron emission tomography, single photon emission computed tomography, nuclear magnetic resonance imaging, Geiger-Muller detectors, nuclear plant safeguards, a 32-bit Fastbus computer, an advanced light water reactor, and nuclear plant maintenance.

Source record↗