Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “power system event”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Quantifying the impacts of climate change and extreme climate events on energy systems

Climate induced extreme weather events and weather variations will affect both the demand of energy and the resilience of energy supply systems. The specific potential impact of extreme events on energy systems has been difficult to quantify due to the unpredictability of future weather events. In this work, we develop a stochastic-robust optimization method to consider both low impact variations and extreme events. Applications of the method to 30 cities in Sweden, by considering 13 climate change scenarios, reveal that uncertainties in renewable energy potential and demand can lead to a significant performance gap (up to 34% for grid integration) brought by future climate variations and a drop in power supply reliability (up to 16%) due to extreme weather events. Finally, appropriate quantification of the climate change impacts will ensure robust operation of the energy systems and enable renewable energy penetration above 30% for a majority of the cities.

54 ENVIRONMENTAL SCIENCES↗

Frequency Recovery in Power Grids Using High-Performance Computing

Maintaining electric power system stability is paramount, especially in extreme contingencies involving unexpected outages of multiple generators or transmission lines that are typical during severe weather events. Such outages often lead to large supply-demand mismatches followed by subsequent system frequency deviations from their nominal value. The extent of frequency deviations is an important metric of system resilience, and its timely mitigation is a central goal of power system operation and control. This paper develops a novel nonlinear model predictive control (NMPC) method to minimize frequency deviations when the grid is affected by an unforeseen loss of multiple components. Our method is based on a novel multi-period alternating current optimal power flow (ACOPF) formulation that accurately models both nonlinear electric power flow physics and the primary and secondary frequency response of generator control mechanisms. We develop a distributed parallel Julia package for solving the large-scale nonlinear optimization problems that result from our NMPC method and thereby address realistic test instances on existing high-performance computing architectures. Our method demonstrates superior performance in terms of frequency recovery over existing industry practices, where generator levels are set based on the solution of single-period classical ACOPF models.

nonlinear model predictive control↗

A Risk-Averse Approach for Distribution Grid Expansion Planning

Recent episodes of natural disasters have challenged the resilience of power grids. Adequate distribution grid planning that properly captures the risk aversion of the utility system planner is a key factor to increase the flexibility of distribution networks to circumvent these events. In this paper, we propose a methodology to determine the optimal portfolio of investments in lines and storage devices in order to minimize a convex combination between expected value and CVaR of operational costs, including energy not served, while taking into account the multistage nature of the energy storage management within this context. While the expected value of energy not served has been traditionally employed to tackle routine failures, we also minimize the CVaR of energy not served to address high-impact, low-probability (HILP) events. We illustrate the performance of the proposed methodology with a 54-Bus system test case.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Introduction to Microgrids

A microgrid is simply a typical power system that has distributed energy resources (DERs), like small diesel generators, with loads in the network. The resiliency offered by microgrids to retain service during system events makes them a suitable support for the electric grid during natural disasters. One key factor that differentiates microgrids from a typical distribution grid is its ability to disconnect itself in the event of a blackout and sustain its loads through DERs. Microgrid systems will reconnect to the main grid when the grid comes back up. The resiliency offered by microgrids to retain service during system events makes them a suitable support for the electric grid during natural disasters. This presentation discusses the typical key steps involved in microgrid planning, installation, operation in a interoperable and interconnectable fashion.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Record-breaking 2020 summer marine heatwaves in the western North Pacific

Record-breaking marine heatwaves (MHWs) occurred in the western North Pacific during the summer of 2020. These unprecedented MHWs were consistent with favorable large-scale conditions that are linked to an anomalous western North Pacific subtropical high (WNPSH), resulting mainly from sea surface temperature (SST) anomalies across the tropical oceans. In addition, a moderate La Niña-like pattern was also conducive to transporting warm seawater to the western North Pacific. Mixed-layer heat budgets suggest that surface heat flux contributed to the SST anomaly in the western subtropical Pacific. In contrast, oceanic heat advection dominanted in the South China Sea and the western equatorial Pacific. Numerical model experiments indicated that the tropical Indian Ocean SST anomalies were responsible for the enhanced WNPSH. The increased zonal SST gradient across the tropical Pacific also played an important role. Inter-ocean interactions can modulate climate variability through ocean-atmospheric coupling and deserve more attention when predicting MHWs within the context of global warming. Additionally, it is critical to consider MHWs as a powerful tool in detecting acute, intense thermal stress events in the coral bleaching pre-warning system.

Coral bleaching↗

Immunity Study: Port Impedance Measurement of PMU and PCI testing under EMP

With the increased requirements of real-time grid monitoring, disturbance location, and situation awareness, Phasor Measurement Units (PMUs) have become more critical for the Wide Area Measurement System (WAMS). However, the vulnerability of PMUs has not been well studied, especially under electromagnetic pulse (EMP) scenarios. The stable operation of the power system will be affected directly once EMP damages them. Therefore, studying their immunity to EMP events is urgent and necessary. In this paper, the effective impedance measurement scheme and pulsed current injection (PCI) testing are proposed for the port impedance measurement and immunity levels of PMUs. The equivalent non-uniform transmission line model is established to eliminate the impact of the fixture in the de-embedding process. Then, the circuit of the pulsed current generator is set to generate a damping sinusoid, and the double exponential wave is applied to the port. Finally, using measured impedance as a generator load, the voltage and current responses of different ports are calculated in the PCI testing simulation. In conclusion, results reveal the characteristics of port impedance, waveforms of voltage and current, and distribution of accumulative energy. The relation between port impedance and the waveforms is discussed.

42 ENGINEERING↗

Distribution Grid Incentive Design with Unknown Agent Behavior

Motivation: During extreme events, traditional grid regulation methods (e.g., energy prices, net power injection limits) may be insufficient. While system operators typically lack control over end-user grid interactions, (e.g., energy demand), incentives can influence behavior - for example, a user that receives a grid-driven incentive may adjust their consumption or expose relevant control variables in response. Problem: Optimize for the best incentive subject to system stability constraints. However, user behavior is unknown to the SO - i.e., for a given incentive, the amount of curtailed load or control variables exposed is unknown.

feedback based control↗

Dataset of Generative AI Workload Power Profiles

This dataset provides a collection of high-resolution (5/10 Hz or every 0.2/0.1 seconds) power consumption profiles for generative artificial intelligence (GenAI) workloads executed on NLR's High Performance Computing (HPC) platform Kestrel. The dataset also includes examples of representative whole-facility power profiles generated using a bottom-up, event-driven, data center energy model . This dataset is designed to support research in energy modeling, infrastructure planning, energy system integration, and sustainability analysis for AI-driven computing systems. The dataset captures time-resolved electrical power measurements across a diverse set of configurations, including variations in job type (inference vs. training), workload (LLM vs. image generation), datasets, and number of compute nodes. Power traces are provided in a standardized format and include both raw/instantaneous and aggregated files. Each profile is accompanied by metadata describing workload parameters, enabling reproducibility and cross-study comparison. The dataset is intended for use in applications such as data center infrastructure planning, energy modeling, demand response and grid impact studies, and development and validation of system-level simulation tools. By making these workload-specific power profiles publicly available, this dataset aims to address the current lack of open, empirical energy data for generative AI systems and to facilitate transparent, reproducible research on the energy and environmental impacts of large-scale AI deployment. If you use this dataset, please cite the associated publication: Vercellino et al., “Measurement of Generative AI Workload Power Profiles for Whole-Facility Data Center Infrastructure Planning,” arXiv:2604.07345 (2026).

97 MATHEMATICS AND COMPUTING↗

Electromagnetic Transient (EMT) Simulation Algorithm for Evaluation of Photovoltaic (PV) Generation Systems

Use of inverter-based resources facilitating renewable energy resources such as photovoltaic (PV) generation is increasing rapidly with decreasing costs and reduced emissions associated. To accommodate such rapid growth of inverter-based resources like PV systems, electromagnetic transient (EMT) simulation models of both PV systems and grids are required to analyze the interaction of PVs in the grid (like the post-event analysis). In addition, the EMT simulation would help with the planning of future power grid with a large number of PVs as well as other inverter-based distributed generation systems. In this paper, the EMT simulation models of PV systems and grids are developed based on the differential algebraic equations (DAEs) representing their EMT dynamics. Furthermore, advanced simulation algorithms including numerical stiffness-based hybrid discretization, DAE clustering and aggregation, multi-order integration, and matrix splitting approaches are applied to accelerate the EMT simulation. The proposed algorithm was applied to 125 PV inverters within 52-bus medium-voltage (MV) distribution grid.

Choi, Jongchan↗

Voltage stability smart meter for analyzing voltage data and controlling an electrical power source and/or an electric appliance

Systems and methods for voltage stability monitoring and active/reactive power support are disclosed herein. In some embodiments, a smart electric meter of an end user in a grid power system can measure the voltage supplied to the end user via the grid power system, and can analyze the voltage data to detect critical voltage characteristics. The critical voltage characteristics may indicate that a voltage collapse event is likely. The smart electric meter can further estimate a voltage stability margin based on the voltage data. If necessary, the smart electric meter can control an electrical power source and/or an electric appliance positioned at or near the end user to increase the voltage stability margin.

Min, Liang↗

Photovoltaic System Health-State Architecture for Data-Driven Failure Detection

The timely detection of photovoltaic (PV) system failures is important for maintaining optimal performance and lifetime reliability. A main challenge remains the lack of a unified health-state architecture for the uninterrupted monitoring and predictive performance of PV systems. To this end, existing failure detection models are strongly dependent on the availability and quality of site-specific historic data. The scope of this work is to address these fundamental challenges by presenting a health-state architecture for advanced PV system monitoring. The proposed architecture comprises of a machine learning model for PV performance modeling and accurate failure diagnosis. The predictive model is optimally trained on low amounts of on-site data using minimal features and coupled to functional routines for data quality verification, whereas the classifier is trained under an enhanced supervised learning regime. The results demonstrated high accuracies for the implemented predictive model, exhibiting normalized root mean square errors lower than 3.40% even when trained with low data shares. The classification results provided evidence that fault conditions can be detected with a sensitivity of 83.91% for synthetic power-loss events (power reduction of 5%) and of 97.99% for field-emulated failures in the test-bench PV system. Finally, this work provides insights on how to construct an accurate PV system with predictive and classification models for the timely detection of faults and uninterrupted monitoring of PV systems, regardless of historic data availability and quality. Such guidelines and insights on the development of accurate health-state architectures for PV plants can have positive implications in operation and maintenance and monitoring strategies, thus improving the system’s performance.

photovoltaics↗

Blackstart Capability and Survivability of Wind Turbines with Fully Rated Converters

We report the blackstart capability of wind turbines is critical for the recovery of wind-dominant power systems from blackouts. If wind power plants are not able to restore a power system, the incorporation of wind resources into electric grids could be limited by blackstart capability. This paper tackles this problem by setting forth a grid-forming controller for Type 4 wind turbines which employ fully rated power converters. To this end, we engineer two-axis anti-windup proportional-integral regulators that serve to ride through restoration disturbances. We also design an active protection system to prevent wind turbines from stalling during recovery from blackouts. We demonstrate in a high-fidelity simulation environment that Type 4 wind turbines with the developed controllers and protection subsystem can: (i) re-energize a notional wind-dominant grid; (ii) ride through asymmetrical faults; and (iii) survive low wind speed events.

17 WIND ENERGY↗

Self-Supervised T-GCN for Detection of Disturbance and Propagation in Power Grid

Urban power systems increasingly rely on dense sensing to monitor grid reliability, yet disturbance labels are scarce and events are rare. We present a self-supervised spatio-temporal method that detects, localizes, and characterizes grid frequency disturbances across urban areas using only unlabeled data. Our approach trains a tiny Temporal Graph Convolutional Network (T-GCN) to forecast per-site frequency residuals (deviation from 60 Hz). The sensor graph is constructed directly from signals using pre-event Pearson correlation with a cross-correlation lag penalty without geocoding. At inference, node-level anomalies are the model's forecast errors; region-level alarms arise from connected components of high-score nodes. We estimate disturbance propagation by computing per-node arrival times (first persistent exceedance), then fit a planar or time-of-arrival model to obtain direction, speed, and an epicenter proxy. With only three real events collected at decisecond resolution across U.S. cities, we evaluate the T-GCN and report time-to-detect, footprint size, and propagation consistency. We further show that short-window embeddings from the T-GCN's hidden states enable few-shot event-vs-background recognition via a simple prototypical classifier. Despite minimal data and no labels, our system yields fast, spatially coherent detection and interpretable propagation maps, offering a practical, lightweight pathway to city-scale grid resilience analytics.

Niu, Haoran [ORNL] (ORCID:0000000155228297)↗

FLC Award: QED: Quantum Ensured Defense of the Smart Electric Grid

A reliable electric power supply is crucial for modern day life as well as national security, economic productivity, and life-and-death essentials. During the COVID pandemic, internet and cell communications became a “must-have” for government and business operations, education, and communicating COVID testing for vaccine information. Loss of electric power quickly leads to human health and national security emergencies. When a major winter storm hit Texas in mid-February 2021, the system was overwhelmed and over 4M people lost power. Although this crisis arose from an unprecedented weather event - not a cyberattack - it serves as a vivid illustration of the impact power disruption can have on our American way of life. The recent cyberattack on the Colonial Oil Pipeline also provides a stark reminder that infrastructure supporting our daily lives has vulnerabilities.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Electric Vehicle Infrastructure Consequence Assessment

With consumers’ growing interest in electric vehicles, extreme fast charging stations are poised to provide high-power charging to rapidly recharge light-duty passenger vehicles. High-power charging requires high-level communication between vehicle and charger to govern the charging process. The coupling of power and communication increases the potential scale of cyberattacks. Using a full Western Electricity Coordinating Council planning model, load manipulation from high-power charging infrastructure is investigated. Two cases of load manipulation are studied: (i) a discrete, widespread system event and (ii) loads modulated near the Western Interconnect’s resonant frequency. In (i) some generation trips and in (ii) oscillations are observed on the California Oregon Intertie. Neither scenario results in significant adverse effects to the grid.

33 ADVANCED PROPULSION SYSTEMS↗

Offline Power Systems Applications Enabled by Phasor Measurement Units: Technical Assistance to the Power Sectors of Southeast Asia

This report provides a brief overview of several offline (non-real-time) applications facilitated by high-resolution time-synchronized measurements recorded by phasor measurement units (PMUs). The high reporting rate and time-synchronization of PMU records provide a detailed view of power system dynamics, enabling electric utilities to obtain a better understanding of their systems. In this report, the following applications have been reviewed: Power plant model validation, System model validation, Ringdown oscillation analysis, Frequency response analysis, Postmortem analysis of disturbance events Along with a brief technical background of the applications above, applicable North American Electric Reliability Corporation (NERC) standards have been discussed, and examples of implementation in North American organizations have been provided. Implementing several of the discussed applications may need a preliminary stage of data gathering from multiple entities, and several frameworks and process flows have been formulated by organizations around the world for this purpose. However, the data-gathering stage has not been considered in the scope of the present report.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

From Ensemble Climate to Ensemble Impacts

Many climate-risk tools rely on ensemble mean projections or endpoint climate snapshots to characterize future hazards. Although convenient for communication, these representations remove the statistical, temporal, and physical information that real infrastructure systems respond to. Infrastructure degradation and failure arise from extremes, sequences, cumulative stress, compound hazards, and nonlinear fragility relationships, none of which survive ensemble averaging or temporal compression. Power-system failure statistics and cascading failure models further show that infrastructure risk is dominated by tail events and path-dependent dynamics rather than by mean conditions. This paper demonstrates why ensemble mean or endpoint-only climate representations are mathematically and physically inconsistent with engineering-grade risk analysis. We outline a model-resolved, time-series-based workflow that preserves extremes, variability, and sequencing by propagating each climate-model realization independently through hazard formation, exposure, fragility, and cascading failure mechanisms. Taking the ensemble of impacts—rather than the ensemble of climate—provides a defensible, physically coherent foundation for infrastructure resilience planning, regulatory compliance, and long-term investment decisions.

54 - ENVIRONMENTAL SCIENCES/GLOBAL CLIMATE CHANGE ↗

North Carolina Water Utility Builds Resilience with Distributed Energy Resources

As the frequency and duration of grid outages increase, backup power systems are becoming more important for ensuring that critical infrastructure continues to provide essential services. Most facilities rely on diesel generators, which may be ineffective during long outages owing to limited fuel supplies and high generator failure rates. Distributed energy resources such as solar, storage, and combined-heat-and-power systems, coupled with on-site biofuel production, offer an alternative source of on-site generation that can provide both cost savings and resilience (i.e., the ability to respond to catastrophic events with longer-term consequences). A mixed-integer linear program minimizes costs and maximizes resilience at a wastewater treatment plant in Wilmington, North Carolina. We find that the plant can reduce life-cycle energy costs by 3.1% through the installation of a hybrid combined-heat-and-power, photovoltaic, and storage system. When paired with existing diesel generators, this system can sustain full load for seven days while saving $664,000 over 25 years and reducing diesel fuel use by 48% compared with the diesel-only solution. This analysis informed a decision by the Cape Fear Public Utility Authority to allocate funds for the implementation of a combined-heat-and-power system at the wastewater treatment plant in fiscal year 2023. Finally, the benefits of deploying hybrid combined-heat-and-power technologies and the utilization of on-site biofuel production extend, on a national scale, to thousands of wastewater treatment facilities and other types of critical infrastructure.

24 POWER TRANSMISSION AND DISTRIBUTION↗