Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “positron”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

SU-E-T-230: Measurement of Proton-Activated Positron Emission with PRESAGE 3-D Dosimeters

Purpose: Measurement of positron emission following proton beam irradiation of a target has been studied as a method of in-vivo dosimetry. Relative dosimetry studies between a phantom and treatment plan are susceptible to range uncertainties from material heterogeneities and setup error. By using the radiochromic polyurethane dosimeter PRESAGE, we can correlate the proton dose distribution to the PET activity measurement within a single detector. The PRESAGE formulation used was developed for high-LET proton radiotherapy, has similar density and RLSP to tissue, and consists of a greater carbon component, which gives it a higher positron signal than many other 3D detectors. Methods: Three cylindrical PRESAGE dosimeters were irradiated semi-uniformly to 500 cGy with 180- MeV protons. The beam was directed along the dosimeter axis and delivered a 2-cm SOBP at the center of the dosimeter. The dosimeters were rushed to a nearby PET/CT where imaging began within 15 minutes, less than a single half-life of 11C. A 3-hr measurement captured the full activation decay. Afterwards, the dose profiles were measured by optical-CT. A direct comparison between the measured dose and the positron emission was performed using CERR software. Results: The correlations between dose distributions and PET activity were consistent with previous studies in that the proximal region of the SOBP displayed the highest activity. The spatial distributions between the dose and activity were similar. Along the central axis of the beam, we found a shift in the distal 80% of 1 cm. The lateral profile showed good agreement between dose and activity. PET imaging times between 30-min and 3-hrs showed <5% discrepancy. Conclusion: PRESAGE dosimeters offer a strong and unique potential to accurately correlate dosimetric and PET activation information. Implementation in an anthropomorphic phantom could be used to study representative treatment plans. NIH grant 5R01CA100835.

60 APPLIED LIFE SCIENCES↗

SU-C-204-07: The Production of Short-Lived Positron Emitters in Proton Therapy

Purpose: To investigate the production and effect of short-lived positron emitters when using PET for in-vivo range verification during a proton therapy irradiation. Methods: The integrated production of short-lived positron emitters in the stopping of 55 MeV protons was measured in water, carbon, phosphorus and calcium targets. The experimental production rates are used to calculate the production on PMMA and a representative set of 4 tissue materials. The number of decays integrated over an irradiation in these materials is calculated as function of the duration of the irradiation, considering irradiations with the same total number of protons. Results: The most copiously produced short-lived nuclides and their production rates relative to the relevant long-lived nuclides are: 12-N (T1/2 = 11 ms) on carbon (9.5% of the 11-C production), 29-P (T1/2 = 4.1 s) on phosphorus (20% of the 30-P production) and 38m-K (T1/2 = 0.92 s) on calcium (113% of the 38g-K production). No short-lived nuclides are produced on water. The most noticeable Result is that for an irradiation in (carbon-rich) adipose tissue, 12-N will dominate the PET image up to an irradiation duration of 70 s. On bone tissue, 15-O dominates over 12-N after 7–15 s (depending on the carbon-to-oxygen ratio). Conclusions: The presence of 12-N needs to be considered in PET imaging during proton beam irradiations as, depending on tissue composition and PET scanning protocol, it may noticeably deteriorate image quality due to the large positron range blurring. The results presented warrant investigations into the energy-dependent production of 12-N, 29-P and 38m-K and their effect on PET imaging during proton irradiations.

60 APPLIED LIFE SCIENCES↗

WE-H-207A-01: Computational Evaluation of High-Resolution 18F Positron Imaging Using Radioluminescence Microscopy with Lu2O3: Eu Thin-Film Scintillator

Purpose: Radioluminescence microscopy, an emerging and powerful tool for high resolution beta imaging, has been applied to molecular imaging of cellular metabolism to understand tumor biology. A novel thin-film (10 µm thickness) scintillator made of Lu{sub 2}O{sub 3}: Eu has been developed to enhance the system performance. However the advances of radioluminescence imaging with Lu{sub 2}O{sub 3}scintillator compared with that using conventional scintillator have not been explored theoretically to date. To validate the advantages of the thin-film scintillator, this study uses a novel computational simulation framework to evaluate the performance of radioluminescence microscopy using both conventional and thin-film scintillators. Methods: Numerical models for different stages of positron imaging are established. Positron from {sup 18}F passing through the scintillator and its neighbor structures are modeled by Monte-Carlo simulation using Geant4. The propagation and focus of photons by the microscope are modeled by convolution with a depth-varying point spread function generated by the Gibson-Lanni model. Photons focused on the detector plane are then captured and converted into electronic signals by an electron multiplication (EM) CCD camera, which is described by a photosensor model considering various noises and charge amplification. Results: The performance metrics of radioluminescence imaging with a thin-film Lu{sub 2}O{sub 3} and conventional CdWO{sub 4} scintillator are compared, including spatial resolution, sensitivity, positron track area and intensity. The spatial resolution of Lu{sub 2}O{sub 3} system can achieve 10 µm maximally, a 12 µm enhancement from that obtained from CdWO{sub 4} system. Meanwhile, the system with Lu{sub 2}O{sub 3} scintillator can provide a higher mean sensitivity: 40% compared with that (21.5%) obtained from CdWO{sub 4} system. Moreover, the simulation results are in good agreement with previous experimental measurements. Conclusion: This study provides a new theoretical understanding of our imaging system and has the potential to promote the development of radioluminescence microscopy for more reliable and robust application on the functional imaging of delicate biological structures. The authors acknowledge funding from NIH grant R01CA186275 and SBIR grant 1R43GM110888-01.

60 APPLIED LIFE SCIENCES↗

Positron states and nanoobjects in proton-irradiated quartz single crystals: Positronium atom in quartz

The influence of proton bombardment and metal atom impurities on the structure of quartz single crystals has been studied. The related defects have been studied using positron annihilation spectroscopy (angular correlation of positron-annihilation photons), acoustic absorption, and optical absorption measurements. It is shown that the presence of a narrow component f in the angular distribution of annihilation photons (ADAP), which is related to the formation of parapositronium, determines a high sensitivity of this method with respect to features of the crystal structure of quartz. It is established that the defectness of the structure of irradiated quartz crystals can be characterized by the ratio f/f{sub 0} of the relative intensities of narrow components in the ADAP curves measured before (f{sub 0}) and after (f) irradiation. Any process leading to a decrease in the probability of positronium formation (e.g., positron loss as a result of the trapping on defects and the interaction with impurity atoms and lattice distortions) decreases the intensity of the narrow component. Based on the ADAP data, estimates of the radii and concentrations of nanodefects in quartz have been obtained and their variation upon annealing at temperatures up to T = 873 K has been studied.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Kinetics of electron cooling of positrons in a storage ring

Kinetic equations are derived for the positron velocity distribution in storage rings with electron cooling. Both drag force and components of the velocity diffusion tensor are calculated. The mechanism of approach to a steady-state positron velocity distribution via electron cooling is discussed. It is shown that the resulting steady-state positron distribution is very close to the electron distribution when the magnetic field is sufficiently strong.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Emission of photons by positrons channeled in single crystals near an energy of 100 GeV

Emission by 120-GeV positrons in the channeling regime in the (011) plane of a silicon single crystal has been considered. Trajectories of positrons under different initial conditions have been calculated within the theory of nonlinear oscillations. The amplitude distribution function of channeled particles has been determined taking into account the nonlinearity of their motion. The intensity of radiation under various initial conditions has been calculated by two different methods. These results can be useful for comparison with experimental data at energies of positrons beginning with 100 GeV and higher.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Orientation dependence of relativistic-positron annihilation in single crystals

An effect of the orientation dependence of the cross section for the single-photon annihilation of relativistic positrons with atomic electrons in a crystal is predicted. It is shown that the probability for the single-photon annihilation of a channeled positron in a crystal may be either suppressed in a crystal in relation to a homogeneous medium or, on the contrary, enhanced. The reason is that, depending on their incidence angle, the positrons may be either in the vicinity of ion planes of the crystal, where the electron density is higher, or far away from them, where the electron density is lower.

74 ATOMIC AND MOLECULAR PHYSICS↗

Methods of optical diagnostics of electron-positron beams and interaction between plasma and high-current electron beam

Optical diagnostics is widely used, both in plasma-physics experiments and in measuring parameters of electron and positron beams in accelerators. In doing so, the approaches with the same methodological base are often applied, which is explained by similarity of certain properties of objects under study despite the fact that these fields of physics are absolutely specific and require using the specialized techniques. The possibility of close contacts and cooperation among scientists concerned with similar problems in different fields of physics contributes to the fruitful exchange of ideas and helps to overcome these problems. It is especially characteristic of the Budker Institute of Nuclear Physics, Siberian Branch of Russian Academy of Sciences, which is famous for pioneering works in the field of electron-positron colliders and controlled thermonuclear fusion. The first part of this paper presents a review of optical diagnostics of the stationary beam parameters in cyclic accelerators of electrons and positrons. The only techniques considered are those that became the recognized tools at colliders and storage rings of the latest generation, without which the routine operation of the facility is difficult to imagine. The second part of the paper describes optical diagnostics used in experiments of heating the plasma by a high-current electron beam.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Elastic positron–proton scattering at low Q$^2$

Systematic differences in the the proton's charge radius, as determined by ordinary atoms and muonic atoms, have caused a resurgence of interest in elastic lepton scattering measurements. The proton's charge radius, defined as the slope of the charge form factor at Q$^2$=0, does not depend on the probe. Any difference in the apparent size of the proton, when determined from ordinary versus muonic hydrogen, could point to new physics or need for the higher order corrections. While recent measurements seem to now be in agreement, there is to date no high precision elastic scattering data with both electrons and positrons. A high precision proton radius measurement could be performed in Hall B at Jefferson Lab with a positron beam and the calorimeter based setup of the PRad experiment. This measurement could also be extended to deuterons where a similar discrepancy has been observed between the muonic and electronic determination of deuteron charge radius. A new, high precision measurement with positrons, when viewed alongside electron scattering measurements and the forthcoming MUSE muon scattering measurement, could help provide new insights into the origins of the proton radius puzzle, and also provide new experimental constraints on radiative correction calculations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

On Possible Interpretations of the High Energy Electron-Positron Spectrum Measured by the Fermi Large Area Telescope

The Fermi-LAT experiment recently reported high precision measurements of the spectrum of cosmic-ray electrons-plus-positrons (CRE) between 20 GeV and 1 TeV. The spectrum shows no prominent spectral features, and is significantly harder than that inferred from several previous experiments. Here we discuss several interpretations of the Fermi results based either on a single large scale Galactic CRE component or by invoking additional electron-positron primary sources, e.g. nearby pulsars or particle Dark Matter annihilation. We show that while the reported Fermi-LAT data alone can be interpreted in terms of a single component scenario, when combined with other complementary experimental results, specifically the CRE spectrum measured by H.E.S.S. and especially the positron fraction reported by PAMELA between 1 and 100 GeV, that class of models fails to provide a consistent interpretation. Rather, we find that several combinations of parameters, involving both the pulsar and dark matter scenarios, allow a consistent description of those results. We also briefly discuss the possibility of discriminating between the pulsar and dark matter interpretations by looking for a possible anisotropy in the CRE flux.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Positron Emission Intensity in the Decay of 86 gY for Use in Dosimetry Studies

The β + -emitting radionuclide 86 gY (t 1/2 = 14.7 h) forms a matched-pair with the β – -emitting therapeutic radionuclide 90Y (t 1/2 = 2.7 d) for theranostic application in medicine. This approach demands a precise knowledge of the positron emission probability of the PET nuclide which was until recently rather uncertain for 86 gY. In this work, an 86 gY source of high radionuclidic purity was prepared and a direct measurement of the positron emission intensity per 100 decay of the parent (hereafter “positron emission intensity”) was performed using high-resolution HPGe detector γ-ray spectroscopy. The electron capture intensity was also determined as an additional check by measuring the K α and K β X-rays of energies 14.1 and 15.8 keV, respectively, using a low energy HPGe detector. From those measurements, normalized values of 27.2 ± 2.0% for β + -emission and 72.8 ± 2.0% for EC were obtained. These results are in excellent agreement with values recently reported in the literature based on a detailed decay scheme study.

61 RADIATION PROTECTION AND DOSIMETRY↗

E166: Polarized Positrons & Polarimetry

A proof-of-principle experiment has been carried out in the Final Focus Test Beam (FFTB) at Stanford Linear Accelerator Center (SLAC) to demonstrate production of polarized positrons in a manner suitable for implementation at the International Linear Collider (ILC). A helical undulator of 2.54 mm period and 1 -m length produced circularly polarized photons with a first harmonic endpoint energy of 8 MeV when traversed by a 46.6 GeV electron beam. The polarized photons were converted to polarized positrons in a 0.2-radiation-length tungsten target. The polarization of these positrons was measured using a Compton transmission polarimeter to have peak value in excess of 80%.

43 PARTICLE ACCELERATORS↗

Prototyping of the ILC Baseline Positron Target

The ILC positron system uses novel helical undulators to create a powerful photon beam from the main electron beam. This beam is passed through a titanium target to convert it into electron-positron pairs. The target is constructed as a 1 m diameter wheel spinning at 2000 RPM to smear the 1 ms ILC pulse train over 10 cm. A pulsed flux concentrating magnet is used to increase the positron capture efficiency. It is cooled to liquid nitrogen temperatures to maximize the flatness of the magnetic field over the 1 ms ILC pulse train. We report on prototyping effort on this system.

43 PARTICLE ACCELERATORS↗

On the Possibility of Accelerating Positron on an Electron Wake at SABER

A new approach for positron acceleration in non-linear plasma wakefields driven by electron beams is presented. Positrons can be produced by colliding an electron beam with a thin foil target embedded in the plasma. Integration of positron production and acceleration in one stage is realized by a single relativistic, intense electron beam. Simulations with the parameters of the proposed SABER facility [1] at SLAC suggest that this concept could be tested there.

43 PARTICLE ACCELERATORS↗

A positron trap and beam apparatus for atomic and molecular scattering experiments

An instrument has been designed and constructed to provide new insights into fundamental, low energy positron scattering processes. The design is based on the Surko trap system and produces a pulsed positron beam with an energy resolution of as good as 54 meV. The design and operation of the apparatus is explained, while the first experimental results from this apparatus have been demonstrated in recent publications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Beam dynamic simulation and optimization of the CLIC positron source and the capture linac

The CLIC Positron Source is based on the hybrid target composed of a crystal and an amorphous target. Simulations have been performed from the exit of the amorphous target to the end of pre-injector linac which captures and accelerates the positrons to an energy of 200 MeV. Simulations are performed by the particle tracking code PARMELA. The magnetic field of the AMD is represented in PARMELA by simple coils. Two modes are applied in this study. The first one is accelerating mode based on acceleration after the AMD. The second one is decelerating mode based on deceleration in the first accelerating structure. It is shown that the decelerating mode gives a higher yield for the e{sup +} beam in the end of the Pre-Injector Linac.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Vibrational cross sections for positron scattering by nitrogen molecules

We present a systematic study of low-energy positron collision with nitrogen molecules. Vibrational elastic and excitation cross sections are calculated using the multichannel version of the continued fractions method in the close-coupling scheme for the positron incident energy up to 20 eV. The interaction potential is treated within the static-correlation-polarization approximation. The comparison of our calculated data with existing theoretical and experimental results is encouraging.

74 ATOMIC AND MOLECULAR PHYSICS↗

Convergent close-coupling calculations of positron-magnesium scattering

The single-center convergent close-coupling method has been applied to positron-magnesium scattering at incident energies from 0.01 to 100 eV. Cross sections are presented for elastic scattering and excitation of 3 {sup 1}P, as well as for the total ionization and total scattering processes. We also provide an estimate of the positronium formation cross section. The results agree very well with the measurements of the total cross section by Stein et al. [Nucl. Instrum. Methods Phys. Res. Sect. B 143, 68 (1998)], and consistent with the positronium formation measurements of Surdutovich et al. [Phys. Rev. A 68, 022709 (2003)] for positron energies above the ionization threshold. For energies below the positronium formation threshold (0.8 eV) we find a large P-wave resonance at 0.17 eV. A similar resonance behavior was found by Mitroy and Bromley [Phys. Rev. Lett. 98, 173001 (2007)] at an energy of 0.1 eV.

74 ATOMIC AND MOLECULAR PHYSICS↗