At least 379 records · Page 21

Compact Hyperspectral Mapper for Environmental Remote Sensing Applications (CHyMERA) End-of-phase Data Review Package

CHYMERA is an Instrument Incubator concept to design, build, and test an instrument that will reduce size, mass, and cost and increase science potential and flexibility for future atmospheric remote sensing missions within the focus of NASA's Earth Science Enterprise (ESE). The primary effort of the development plan will be on high spatial resolution ozone, N02, S02, aerosol, and cloud measurements, but it is hoped that the techniques developed will prove useful for other measurements as well. The core design will involve a high performance, wide field-of-view (FOV) front end telescope which will illuminate a filter/focal plane array (FFPA) package. The use of a non-dispersive optical configuration will reduce size, mass and complexity. The wide FOV optics will permit short duration global coverage (1-2 days) without the need for a scanner.

Janz, Scott J.↗

Design of a 2.5 Gbps Optical Transmitter for the International Space Station

A high data rate laser transmitter assembly (LTA) has been designed as the source for an optical free-space communication link between the International Space Station and the 1-meter Optical Communication Telescope Laboratory (OCTL) to be built at the Table Mountain Facility (IMF, Wrightwood, CA). The transmitter design concept uses a fiber-based master oscillator power amplifier (MOPA) configuration with an average output power of 200 made at a 1550 nm transmit wavelength. This transmitter source is also designed to provide a signal at 980 nm to the Silicon-based focal plane array for the point-ahead beam control function. This novel integration of a 980 nm boresight signal allows the use of Silicon based imagers for the acquisition/tracking and point-ahead functions, yet permits the transmit signal to be at any wavelength outside the Silicon sensitivity. The LTA, a sub-system of the Flight Terminal, has been designed to have a selectable data rate from 155 - 2500 Mbps in discrete steps. It also incorporates a 2.5 Gbps pseudo-random bit sequence (PRBS) generator for complete link testing and diagnostics. The design emphasizes using commercial off the shelf components (COTS).

Ortiz, Gerardo G.↗

Optical Communication Transceiver For X2000; Second Delivery Program

Conceptual-design of a multi-functional optical instrument is underway for the X2000 - Second Delivery Program. The transceiver will perform both free-space optical- communication and science imaging by sharing a common 10-cm aperture telescope. A single focal-plane array (such as, APS-Active Pixel Sensor) in conjunction with a filter wheel will be used to perform the two functions. Targeted values for the transceiver's weight and power consumption are: 4 Kg, and 14 W. This transceiver would be capable of delivering greater than IO Kbps to a 3.5-m diameter receiving station from the range of 2 AU during day-time.

Hemmati, H.↗

A Near IR Fabry-Perot Interferometer for Wide Field, Low Resolution Hyperspectral Imaging on the Next Generation Space Telescope

We discuss work in progress on a near-infrared tunable bandpass filter for the Goddard baseline wide field camera concept of the Next Generation Space Telescope (NGST) Integrated Science Instrument Module (ISIM). This filter, the Demonstration Unit for Low Order Cryogenic Etalon (DULCE), is designed to demonstrate a high efficiency scanning Fabry-Perot etalon operating in interference orders 1 - 4 at 30K with a high stability DSP based servo control system. DULCE is currently the only available tunable filter for lower order cryogenic operation in the near infrared. In this application, scanning etalons will illuminate the focal plane arrays with a single order of interference to enable wide field lower resolution hyperspectral imaging over a wide range of redshifts. We discuss why tunable filters are an important instrument component in future space-based observatories.

Barry, R. K.↗

Long-Wavelength 640 x 486 GaAs/AlGaAs Quantum Well Infrared Photodetector Snap-Shot Camera

A 9-micrometer cutoff 640 x 486 snap-shot quantum well infrared photodetector (QWIP) camera has been demonstrated. The performance of this QWIP camera is reported including indoor and outdoor imaging. The noise equivalent differential temperature (NE.deltaT) of 36 mK has been achieved at 300 K background with f/2 optics. This is in good agreement with expected focal plane array sensitivity due to the practical limitations on charge handling capacity of the multiplexer, read noise, bias voltage, and operating temperature.

Gunapala, Sarath D.↗

Earth Observing-1 Advanced Land Imager: Radiometric Response Calibration

The Advanced Land Imager (ALI) is one of three instruments to be flown on the first Earth Observing mission (EO-1) under NASA's New Millennium Program (NMP). ALI contains a number of innovative features, including a wide field of view optical design, compact multispectral focal plane arrays, non-cryogenic HgCdTe detectors for the short wave infrared bands, and silicon carbide optics. This document outlines the techniques adopted during ground calibration of the radiometric response of the Advanced Land Imager. Results from system level measurements of the instrument response, signal-to-noise ratio, saturation radiance, and dynamic range for all detectors of every spectral band are also presented.

Mendenhall, J. A.↗

Simulated Performance of the Orbiting Wide-angle Light Collectors (OWL) Experiment

The Orbiting Wide-angle Light collectors (OWL) experiment is in NASA's mid-term strategic plan and will stereoscopically image, from equatorial orbit, the air fluorescence signal generated by airshowers induced by the ultrahigh energy (E greater than few x 10(exp 19) eV) component of the cosmic radiation. The use of a space-based platform enables an extremely large event acceptance aperture and thus will allow a high statistics measurement of these rare events. Detailed Monte Carlo simulations are required to quantify the physics potential of the mission as well as optimize the instrumental parameters. This paper reports on the results of the GSFC Monte Carlo simulation for two different, OWL instrument baseline designs. These results indicate that, assuming a continuation of the cosmic ray spectrum (theta approximately E(exp -2.75), OWL could have an event rate of 4000 events/year with E greater than or equal to 10(exp 20) eV. Preliminary results, based upon these Monte Carlo simulations, indicate that events can be accurately reconstructed in the detector focal plane arrays for the OWL instrument baseline designs under consideration.

Krizmanic, J. F.↗

Fully "Eqwipped" to See the Heat

Developed by NASA's Jet Propulsion Laboratory over the past decade with an excess of $15 million of government research and development investment, quantum well infrared photodetectors (QWIPs) are infrared imaging sensors that can operate in the long wavelength portion of the electromagnetic spectrum, where objects at an ambient temperature emit the most energy. QWIPTECH was formed in July 1998 to offer JPL's QWIPs in a commercial format. The company currently holds an exclusive worldwide license to manufacture and sell the infrared photodetector sensors as part of a focal plane array called a QWIP Chip(TM). The QWIP Chip provides high thermal sensitivity (0.001 C) and possesses a broad dynamic range, permitting precise observations over a wide range of temperatures. Since the technology uses heat rather than light, it can "see" in complete darkness and through conditions such as dust, smoke, and light fog.

Source record↗

Gas Scintillation Proportional Counters for High-Energy X-ray Astronomy

A focal plane array of high-pressure gas scintillation proportional counters (GSPC) for a balloon-borne hard-x-ray telescope is under development at the Marshall Space Flight Center. These detectors have an active area of approx. 20 sq cm, and are filled with a high pressure (10(exp 6) Pa) xenon-helium mixture. Imaging is via crossed-grid position-sensitive phototubes sensitive in the UV region. The performance of the GSPC is well matched to that of the telescopes x-ray optics which have response to 75 keV and a focal spot size of approx. 500 microns. The detector s energy resolution, 4% FWHM at 60 keV, is adequate for resolving the broad spectral lines of astrophysical importance and for accurate continuum measurements. Full details of the instrument and its performance will be provided.

Gubarev, Mikhail↗

Carrier Plus: A sensor payload for Living With a Star Space Environment Testbed (LWS/SET)

The Defense Threat Reduction Agency (DTR4) and National Aeronautics and Space Administration (NASA) Goddard Space Flight Center are collaborating to develop the Carrier Plus sensor experiment platform as a capability of the Space Environments Testbed (SET). The Space Environment Testbed (SET) provides flight opportunities for technology experiments as part of NASA's Living With a Star (LWS) program. The Carrier Plus will provide new capability to characterize sensor technologies such as state-of-the-art visible focal plane arrays (FPAs) in a natural space radiation environment. The technical objectives include on-orbit validation of recently developed FPA technologies and performance prediction methodologies, as well as characterization of the FPA radiation response to total ionizing dose damage, displacement damage and transients. It is expected that the sensor experiment will carry 4-6 FPAs and associated radiation correlative environment monitors (CEMs) for a 2006-2007 launch. Sensor technology candidates may include n- and p-charge coupled devices (CCDs), active pixel sensors (APS), and hybrid CMOS arrays. The presentation will describe the Carrier Plus goals and objectives, as well as provide details about the architecture and design. More information on the LWS program can be found at http://lws.gsfc.nasa.gov/. Business announcements for LWS/SET and program briefings are posted at http://lws-set.gsfc.nasa.gov

Marshall, Cheryl J.↗

Chemical and physical gradients along the OMC-1 ridge

We present a survey of the distribution of 20 chemical and isotopic molecular species along the central ridge of the Orion molecular cloud from 6' north to 6' south of BN-KL observed with the QUARRY focal plane array on the FCRAO 14 m telescope, which provides an angular resolution of approximately 50" in the 3 mm wavelength region. We use standard tools of multivariate analysis for a systematic investigation of the similarities and differences among the maps of integrated intensities of the 32 lines observed. The maps fall in three broad classes: first, those strongly peaked toward BN-KL; second, those having rather flat distributions along the ridge; and third, those with a clear north-south gradient or contrast. We identify six positions or regions where we calculate relative abundances. Line velocities and line widths indicate that the optically thin lines generally trace the same volume of dense gas, except in the molecular bar, where C18O, C34S, H13CO+, CN, C2H, SO, and C3H2 have velocities characteristic of the bar itself, whereas the emission from other detected species is dominated by the background cloud. The strongest abundance variations in our data are the well-known enhancements seen in HCN, CH3OH, HC3N, and SO toward BN-KL and, less strongly, toward the Orion-South outflow 1'.3S. The principal result of this study is that along the extended quiescent ridge the chemical abundances, within factors of 3-4, exhibit an impressive degree of uniformity. The northern part of the ridge has a chemistry closest to that found in quiescent dense clouds. While temperature and density are similar around the northern radical-ion peak near 3'.5N and in the southern core near 4'.2S, some abundances, in particular, those of the ions HCO+ and N2H+, are significantly lower toward 4'.2S. The areas near 4.'2S and the molecular bar itself around (1'.7E, 2'.4S) stand out with peculiar and similar properties probably caused by stronger UV fields penetrating deeper into the clumpy molecular gas. This leads to higher electron abundances and thereby reduced abundances of the ions, as well as a lack of complex molecules.

NASA Discipline Exobiology↗

X-Ray Fluorescence Solvent Detection at the Substrate-Adhesive Interface

With environmental regulations limiting the use of volatile organic compounds, low-vapor pressure solvents have replaced traditional degreasing solvents for bond substrate preparation. When used to clean and prepare porous bond substrates such as phenolic composites, low vapor pressure solvents can penetrate deep into substrate pore networks and remain there for extended periods. Trapped solvents can interact with applied adhesives either prior to or during cure, potentially compromising bond properties. Currently, methods for characterizing solvent time-depth profiles in bond substrates are limited to bulk gravimetric or sectioning techniques. While sectioning techniques such as microtome allow construction of solvent depth profiles, their depth resolution and reliability are limited by substrate type. Sectioning techniques are particularly limited near the adhesive-substrate interface where depth resolution is further limited by adhesive-substrate hardness and, in the case of a partially cured adhesive, mechanical properties differences. Additionally, sectioning techniques cannot provide information about lateral solvent diffusion. Cross-section component mapping is an alternative method for measuring solvent migration in porous substrates that eliminates the issues associated with sectioning techniques. With cross-section mapping, the solvent-wiped substrate is sectioned perpendicular rather than parallel to the wiped surface, and the sectioned surface is analyzed for the solvent or solvent components of interest using a two-dimensional mapping or imaging technique. Solvent mapping can be performed using either direct or indirect methods. With a direct method, one or more solvent components are mapped using red or Raman spectroscopy together with a moveable sample stage and/or focal plane array detector. With an indirect method, an elemental "tag" not present in the substrate is added to the solvent before the substrate is wiped. Following cross sectioning, the tag element can then be mapped by its characteristic x-ray emission using either x-ray fluorescence, or electron-beam energy-and wavelength-dispersive x-ray spectrometry. The direct mapping techniques avoid issues of different diffusion or migration rates of solvents and elemental tags, while the indirect techniques avoid spectral resolution issues in cases where solvents and substrates have adjacent or overlapping peaks. In this study, cross-section component indirect mapping is being evaluated as a method for measuring migration of d-limonene based solvents in glass-cloth phenolic composite (GCP) prior to and during subsequent bonding and epoxy adhesive cure.

Wurth, Laura↗

Temperature-dependent optical properties of Cd(1-x),Zn(x),Te substitute material

In this study, we report cryogenic optical properties of Cd(l-x), Zn(x), Te wafers that are used as substrate seed layers in the manufacturing of HgCdTe focal-plane array detectors. These studies are motivated by the fact that the substrate optical properties influence the overall detector performance. The studies consist of measuring the substrate frequency dependent transmittance T(W) and reflectance R(W) above and below the optical band-gap in the UV/Visible and infrared frequency ranges, and with temperature variation of the sample from 5 to 300 K. Determination of the optical absorption from these measurements show that the optical absorption energy gap near 1.6 eV shows a substantial increase as the temperature is reduced from 300 to 5 K. Furthermore, we observe the presence of infrared-active optical phonons whose peak frequency shifts as the temperature of the sample is varied over the measured temperature range. The theoretical frequency dependent optical conductivity, with allowance for redistribution of spectral weight among the interband transition charge carriers, will be discussed.

Quijada, Manuel A.↗

Delta-doped imagers for UV and EUV applications

In this paper we will discuss performance of delta-doped CCDs in UV and EUV, our in-house thinning capability, bonding approaches for producing flat focal plane arrays, and in-house capabilities of directly applied antireflection coatings.

UV EUV delta-doped imagers↗

(abstract) Applications of Long-wavelength 256x256 GaAs/Al&subx;Ga&sub1-x;As Quantum Well Infrared Photodetector Hand-held Camera

A 9 (micro)m 256x256 hand-held quantum well infrared photodetector (QWIP) camera has been demonstrated. Excellent imagery, with a noise equivalent differential temperature (NE(gamma)) of 26 mK has been achieved. In this presentation, we discuss the development of this very sensitive long wavelength infrared (LWIR) camera based on a GaAs/AlGaAs QWIP focal plane array, its performance in quantum efficience, NA(gamma), minimum resolvable temperature (MRTD), uniformity, operability, and its applications.

GaAs infrared photodetector quantum well QUIP nois↗

15 cut-off 128x128 Quantum Well Infrared Photodetectors (QWIPS) Camera

We discuss the development and the performance of a very long wavelength (13.5 - 15 128x128 AlGaAs/GaAs multiquantum well infrared imaging system. Highly uniform, high-yield QWIP focal plane array was hybridized to a CMOS multiplexer operating in a direct injection mode. For efficient light coupling an integral random scattering reflector (Random Grating) was incorporated. Due to the high uniformity, excellent imagery, low noise as well as a noise equivalent temperature difference (NE T) of less than 30 mK were obtained when operating around 45 K. Therefore, high image contrast signal to noise ratio has been achieved.

128x128 Photodetectors↗

A Combined Laser-Communication and Imager for Microspacecraft (ACLAIM)

ACLAIM is a multi-function instrument consisting of a laser communication terminal and an imaging camera that share a common telescope. A single APS- (Active Pixel Sensor) based focal-plane-array is used to perform both the acquisition and tracking (for laser communication) and science imaging functions.

Laser Communication Optical Communication Science ↗