Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “photonic signal processing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Continuum-electron interferometry for enhancement of photoelectron circular dichroism and measurement of bound, free, and mixed contributions to chiral response

We develop photoelectron interferometry based on laser-assisted extreme ultraviolet ionization for flexible and robust control of photoelectron circular dichroism in randomly oriented chiral molecules. A comb of XUV photons ionizes a sample of chiral molecules in the presence of a time-delayed infrared or visible laser pulse promoting interferences between components of the XUV-ionized photoelectron wave packet. In striking contrast to multicolor phase control schemes relying on pulse shaping techniques, the magnitude of the resulting chiral signal is here controlled by the time delay between the XUV and laser pulses. Furthermore, we show that the relative polarization configurations of the XUV and IR fields allow for disentangling the contributions of bound and continuum states to the chiral response. Our proposal provides a simple, robust, and versatile tool for the control of photoelectron circular dichroism and experimentally feasible protocol for probing the individual contributions of bound and continuum states to the photoelectron circular dichroism in a time-resolved manner.

atomic and molecular processes in external fields↗

Optical Communications Channel Combiner

NASA has identified deep-space optical communications links as an integral part of a unified space communication network in order to provide data rates in excess of 100 Mb/s. The distances and limited power inherent in a deep-space optical downlink necessitate the use of photon-counting detectors and a power-efficient modulation such as pulse position modulation (PPM). For the output of each photodetector, whether from a separate telescope or a portion of the detection area, a communication receiver estimates a log-likelihood ratio for each PPM slot. To realize the full effective aperture of these receivers, their outputs must be combined prior to information decoding. A channel combiner was developed to synchronize the log-likelihood ratio (LLR) sequences of multiple receivers, and then combines these into a single LLR sequence for information decoding. The channel combiner synchronizes the LLR sequences of up to three receivers and then combines these into a single LLR sequence for output. The channel combiner has three channel inputs, each of which takes as input a sequence of four-bit LLRs for each PPM slot in a codeword via a XAUI 10 Gb/s quad optical fiber interface. The cross-correlation between the channels LLR time series are calculated and used to synchronize the sequences prior to combining. The output of the channel combiner is a sequence of four-bit LLRs for each PPM slot in a codeword via a XAUI 10 Gb/s quad optical fiber interface. The unit is controlled through a 1 Gb/s Ethernet UDP/IP interface. A deep-space optical communication link has not yet been demonstrated. This ground-station channel combiner was developed to demonstrate this capability and is unique in its ability to process such a signal.

Quirk, Kevin J.↗

SQMS Quantum R&D in Machine Learning, Optimization and Sensing beyond Fundamental Physics Applications

This newly formed team at SQMS under the Ecosystem Thrust is looking to develop capabilities impacting societal advances outside the core domain of HEP and condensed matter physics. We explicitly leverage the experimental and algorithmic innovations developed across all groups as well as connect to broad-scope external projects of the diverse team of PIs. As the inaugural set of projects, we are studying numerically quantum machine learning models inspired by efficiently trainable echo-state and orthogonal neural networks and developing designs for related experiments to be performed on quantum processors based on SQMS SRF cQED technology and Rigetti s transmon arrays. Investigated models exploit ideas and lessons learned from multiple prior work by SQMS team members in a variety of internal and external activities [R1]. Target initial applications include noisy signal processing, potentially captured by quantum sensors or noisy QPUs, as well as simulation and classification of healthcare data. For instance, image reconstruction of the brain s electrical properties by solving the inverse Maxwell equation problem with uncertainty [R2] through a hybrid quantum-classical physics-informed architecture for time-dependent processes [R3]. The group is also investigating the application and development of novel quantum sensors based on magnetic levitation of a superconducting sphere coupled to a superconducting qubit. This coupling enables high-precision measurements of the position of the sphere, which can be used for sensitive detection of forces, enabling practical applications such as gravimetry for geophysics analysis, or accelerometry for GPS-denied navigation [R4] [R1] Rieffel, Eleanor G., Ata Akbari Asanjan, M. Sohaib Alam, Namit Anand, David E. Bernal Neira, Sophie Block, Lucas T. Brady et al. "Assessing and advancing the potential of quantum computing: A NASA case study." Future Generation Computer Systems (2024). [R2] Yu, X., Serrall s, J.E., Giannakopoulos, I.I., Liu, Z., Daniel, L., Lattanzi, R. and Zhang, Z., 2023. Pifon-ept: Mr-based electrical property tomography using physics-informed fourier networks. IEEE Journal on Multiscale and Multiphysics Computational Techniques. [R3] Wudarski, Filip, Daniel OConnor, Shaun Geaney, Ata Akbari Asanjan, Max Wilson, Elena Strbac, P. Aaron Lott, and Davide Venturelli. "Hybrid quantum-classical reservoir computing for simulating chaotic systems." arXiv preprint arXiv:2311.14105 (2023). [R4] Higgins, Gerard, Saarik Kalia, and Zhen Liu. "Maglev for dark matter: Dark-photon and axion dark matter sensing with levitated superconductors." Physical Review D 109.5 (2024): 055024.

Venturelli, Davide↗

Design and implementation of the new scintillation light detection system of ICARUS T600

ICARUS T600 is the far detector of the Short Baseline Neutrino program at Fermilab (U.S.A.), which foresees three Liquid Argon Time Projection Chambers along the Booster Neutrino Beam line to search for LSND-like sterile neutrino signal. The T600 detector underwent a significant overhauling process at CERN, introducing new technological developments while maintaining the already achieved performances. The realization of a new liquid argon scintillation light detection system is a primary task of the detector overhaul. As the detector will be subject to a huge flux of cosmic rays, the light detection system should allow the 3D reconstruction of events contributing to the identification of neutrino interactions in the beam spill gate. The design and implementation of the new scintillation light detection system of ICARUS T600 is described.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Three Photon Excited Image Scanning Microscopy for in-Depth Super-Resolution Studies of Biological Samples

Multiphoton laser scanning microscopy is a powerful tool for deep imaging of thick biological samples. Image scanning microscopy (ISM) has demonstrated significant improvements in the signal-to-noise ratio in confocal laser scanning microscopy, while at the same time improving upon the effectively attainable resolution. Two-photon excitation (2PE), combined with ISM, has been shown to allow for deep tissue imaging with enhanced resolution compared to 2PE microscopy. Three-photon excitation (3PE) has enabled record imaging depth and contrast for multiphoton imaging, due to the superior suppression of out-of-focus signal generation. In this paper, we demonstrate super-resolution 3PE ISM. This is achieved using a single-photon avalanche detector array, and 1040-nm pulses for 3PE of blue fluorescence. This method enables subdiffraction limited resolution imaging of biological samples stained with blue fluorescent markers, such as mouse myocardial and spinal cord tissues stained with 4 ′ , 6 -diamidino-2-phenylindole. Deconvolution improves the resolving power further and allows for imaging with better than λ / 8 resolution with respect to the 3PE wavelength λ . With the ISM pixel reassignment procedure, we demonstrate a resolution enhancement of ∼ 1.6 laterally, compared to the resolution attained using a photomultiplier tube in a non-descanned detection arrangement, and a factor of ∼ 1.8 enhancement in axial resolution. The experimentally measured three-dimensional point spread function volume is shrunk ∼ 4.4 -fold, which is close to the theoretically expected enhancement. Published by the American Physical Society 2024

47 OTHER INSTRUMENTATION↗

Detector Tilt Considerations in Bragg Coherent Diffraction Imaging: A Simulation Study

This paper addresses the three-dimensional signal distortion and image reconstruction issues in X-ray Bragg coherent diffraction imaging (BCDI) in the event of a general non-orthogonal orientation of the area detector with respect to the diffracted beam. Growing interest in novel BCDI adaptations at fourth-generation synchrotron light sources has necessitated improvisations in the experimental configuration and the subsequent data analysis. One such possibly unavoidable improvisation that is envisioned in this paper is a photon-counting area detector whose face is tilted away from the perpendicular to the Bragg-diffracted beam during the acquisition of the coherent diffraction signal. We describe a likely circumstance in which one would require such a detector configuration, along with the experimental precedent at third-generation synchrotrons. Using physically accurate diffraction simulations from synthetic scatterers in the presence of such tilted detectors, we analyze the general nature of the observed signal distortion qualitatively and quantitatively and provide a prescription to correct for it during image reconstruction. Our simulations and reconstructions are based on an adaptation of the known theory of BCDI sampling geometry, as well as the recently developed projection-based methods of wavefield propagation. Such configurational modifications and their numerical remedies are potentially valuable in realizing unconventional coherent diffraction measurement geometries, eventually paving the way for the integration of BCDI into new material characterization experiments at next-generation light sources.

36 MATERIALS SCIENCE↗

Low-pass spectral analysis of time-resolved serial femtosecond crystallography data

Low-pass spectral analysis (LPSA) is a recently developed dynamics retrieval algorithm showing excellent retrieval properties when applied to model data affected by extreme incompleteness and stochastic weighting. In this work, we apply LPSA to an experimental time-resolved serial femtosecond crystallography (TR-SFX) dataset from the membrane protein bacteriorhodopsin (bR) and analyze its parametric sensitivity. While most dynamical modes are contaminated by nonphysical high-frequency features, we identify two dominant modes, which are little affected by spurious frequencies. The dynamics retrieved using these modes shows an isomerization signal compatible with previous findings. We employ synthetic data with increasing timing uncertainty, increasing incompleteness level, pixel-dependent incompleteness, and photon counting errors to investigate the root cause of the high-frequency contamination of our TR-SFX modes. By testing a range of methods, we show that timing errors comparable to the dynamical periods to be retrieved produce a smearing of dynamical features, hampering dynamics retrieval, but with no introduction of spurious components in the solution, when convergence criteria are met. Using model data, we are able to attribute the high-frequency contamination of low-order dynamical modes to the high levels of noise present in the data. Finally, we propose a method to handle missing observations that produces a substantial dynamics retrieval improvement from synthetic data with a significant static component. Reprocessing of the bR TR-SFX data using the improved method yields dynamical movies with strong isomerization signals compatible with previous findings.

59 BASIC BIOLOGICAL SCIENCES↗

Photonic Doppler velocimetry of ohmically exploded aluminum surfaces

Photonic Doppler Velocimetry (PDV) was used to measure the exploding surface of coated metal driven by lineal current density increasing at 3 × 10 15 A/m/s. Here, aluminum-6061 rods were coated with three thicknesses (5, 17, and 41 μm) of Parylene-N and driven to 850 kA in approximately 100 ns, with the metal thicker than the skin depth. According to PDV, the metal surface melts at 85 ± 13 T and expands with a constant acceleration. Then, at surface magnetic field 140-180 T, the metal acceleration begins to increase in time. Later, plasma forms on, and is correlated with PDV signal loss from, uncoated aluminum rods, 5-μm-coated rods, and 17-μm-coated rods, while no evidence suggests plasma forms on 41-μm-coated metal.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Two-Photon Fluorescence Microscope for Microgravity Research

A two-photon fluorescence microscope has been developed for the study of biophysical phenomena. Two-photon microscopy is a novel form of laser-based scanning microscopy that enables three-dimensional imaging without many of the problems inherent in confocal microscopy. Unlike one-photon optical microscopy, two-photon microscopy utilizes the simultaneous nonlinear absorption of two near-infrared photons. However, the efficiency of two-photon absorption is much lower than that of one-photon absorption, so an ultra-fast pulsed laser source is typically employed. On the other hand, the critical energy threshold for two-photon absorption leads to fluorophore excitation that is intrinsically localized to the focal volume. Consequently, two-photon microscopy enables optical sectioning and confocal performance without the need for a signal-limiting pinhole. In addition, there is a reduction (relative to one-photon optical microscopy) in photon-induced damage because of the longer excitation wavelength. This reduction is especially advantageous for in vivo studies. Relative to confocal microscopy, there is also a reduction in background fluorescence, and, because of a reduction in Rayleigh scattering, there is a 4 increase of penetration depth. The prohibitive cost of a commercial two-photon fluorescence-microscope system, as well as a need for modularity, has led to the construction of a custom-built system (see Figure 1). This system includes a coherent mode-locked titanium: sapphire laser emitting 120-fs-duration pulses at a repetition rate of 80 MHz. The pulsed laser has an average output power of 800 mW and a wavelength tuning range of 700 to 980 nm, enabling the excitation of a variety of targeted fluorophores. The output from the laser is attenuated, spatially filtered, and then directed into a confocal scanning head that has been modified to provide for side entry of the laser beam. The laser output coupler has been replaced with a dichroic filter that reflects the longer-wavelength excitation light and passes the shorter-wavelength fluorescence light. Also, the confocal pinhole has been removed to increase the signal strength. The laser beam is scanned by a twoperpendicular- axis pair of galvanometer mirrors through a pupil transfer lens into the side port of an inverted microscope. Finally, the beam is focused by a 63-magnification, 1.3-numerical- aperture oil-immersion objective lens onto a specimen. The pupil transfer lens serves to match the intermediate image planes of the scanning head and the microscope, and its location is critical. In order to maximize the quality of the image, (that is, the point spread function of the objective lens for all scan positions), the entire system was modeled in optical-design software, and the various free design parameters (the parameters of the spatial-filter components as well as the separations of all of the system components) were determined through an iterative optimization process. A modular design was chosen to facilitate access to the optical train for future fluorescence correlation spectroscopy and fluorescence-lifetime experiments.

Fischer, David G.↗

State-selective probing of CO 2 autoionizing inner valence Rydberg states with attosecond extreme ultraviolet four-wave-mixing spectroscopy

Nonlinear spectroscopies can disentangle spectra that are congested due to inhomogeneous broadening. Here, in conjunction with theoretical calculations, attosecond extreme ultraviolet (XUV) four-wave-mixing (FWM) spectroscopy is utilized to probe the dynamics of autoionizing inner valence excited Rydberg states of the polyatomic molecule, CO 2 . This tabletop nonlinear technique employs a short attosecond XUV pulse train and two noncollinear, few-cycle near-infrared pulses to generate background-free XUV wave-mixing signals. FWM emission is observed from the n=5-7 states of the Henning sharp ndσ g Rydberg series that converges to the ionic $\widetilde{B}$ 2 Σ$^{+}_{u}$ state. However, these transient emission signals decay with lifetimes of 33 ± 6, 53 ± 2, and 94 ± 2 fs, respectively, which calculations show are consistent with the lifetimes of the short-lived n=6-8 members of the nsσ g character Henning diffuse Rydberg series. The oscillator strengths of transitions between states involved in all possible resonant FWM processes are calculated, verifying that the nonlinear spectra are dominated by pathways described by an initial excitation to the diffuse nsσ g Rydberg series and emission from the sharp ndσ g Rydberg series. The results substantiate not only that attosecond XUV FWM spectroscopy produces rigorous and meaningful measurements of ultrafast dynamics in polyatomic systems, but also that nonlinear spectroscopic techniques are versatile tools to selectively probe dynamics that are otherwise difficult to access.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

X-Ray Spectroscopy of Optically Bright Planets using the Chandra Observatory

Since its launch in July 1999, Chandra's Advanced CCD Imaging Spectrometer (ACIS) has observed several planets (Venus, Mars, Jupiter and Saturn) and 6 comets. At 0.5 arc-second spatial resolution, ACIS detects individual x-ray photons with good quantum efficiency (25% at 0.6 KeV) and energy resolution (20% FWHM at 0.6 KeV). However, the ACIS CCDs are also sensitive to optical and near-infrared light, which is absorbed by optical blocking filters (OBFs) that eliminate optical contamination from all but the brightest extended sources, e.g., planets. .Jupiter at opposition subseconds approx.45 arc-seconds (90 CCD pixels.) Since Chandra is incapable of tracking a moving target, the planet takes 10 - 20 kiloseconds to move across the most sensitive ACIS CCD, after which the observatory must be re-pointed. Meanwhile, the OBF covering that CCD adds an opt,ical signal equivalent to approx.110 eV to each pixel that lies within thc outline of the Jovian disk. This has three consequences: (1) the observatory must be pointed away from Jupiter while CCD bias maps are constructed; (2) most x-rays from within the optical image will be misidentified as charged-particle background and ignored; and (3) those x-rays that are reported will bc assigned anomalously high energies. The same also applies to thc other planets, but is less serious since they are either dimmer at optical wavelengths, or they show less apparent motion across the sky, permitting reduced CCD exposure times: the optical contamination from Saturn acids approx.15 eV per pixel, and from Mars and Venus approx.31 eV. After analyzing a series of short .Jupiter observations in December 2000, ACIS parameters were optimized for the February 2003 opposition. CCD bias maps were constructed while Chandra pointed away from Jupiter, and the subsequent observations employed on-board software to ignore any pixel that contained less charge than that expected from optical leakage. In addition, ACIS was commanded to report 5 x 5 arrays of pixel values surrounding each x-ray event, and the outlying values were employed during ground processing to correct for the optical contamination.

Ford, P. G.↗

Deep learning-based spatio-temporal fusion for high-fidelity ultra-high-speed X-ray radiography

Full-field ultra-high-speed (UHS) X-ray imaging experiments have been well established to characterize various processes and phenomena. However, the potential of UHS experiments through the joint acquisition of X-ray videos with distinct configurations has not been fully exploited. In this paper, we investigate the use of a deep learning-based spatio-temporal fusion (STF) framework to fuse two complementary sequences of X-ray images and reconstruct the target image sequence with high spatial resolution, high frame rate and high fidelity. We applied a transfer learning strategy to train the model and compared the peak signal-to-noise ratio (PSNR), average absolute difference (AAD) and structural similarity (SSIM) of the proposed framework on two independent X-ray data sets with those obtained from a baseline deep learning model, a Bayesian fusion framework and the bicubic interpolation method. The proposed framework outperformed the other methods with various configurations of the input frame separations and image noise levels. With three subsequent images from the low-resolution (LR) sequence of a four times lower spatial resolution and another two images from the high-resolution (HR) sequence of a 20 times lower frame rate, the proposed approach achieved average PSNRs of 37.57 dB and 35.15 dB, respectively. When coupled with the appropriate combination of high-speed cameras, the proposed approach will enhance the performance and therefore the scientific value of UHS X-ray imaging experiments.

deep learning↗

X-ray Computed Tomography of Irradiated and Unirradiated AGR-3/4 Compacts

X-ray Computed Tomography (XCT) has been utilized to image and characterize compacts from the combined third and fourth irradiation of the Advanced Gas Reactor (AGR) Program, AGR-3/4, fuel. The experiment contained tristructural isotropic (TRISO)-coated fuel particles as well as designed-to-fail (DTF) fuel particles. Two irradiated compacts, representing the lower and higher range of AGR-3/4 burnup (4.85% and 14.92% fissions per initial heavy metal atom FIMA) were examined. These represent the first known highly irradiated TRISO fuel compacts to be examined via X-ray CT. Additionally, two unirradiated compacts from the same production batch as the examined irradiation compacts were also imaged for a baseline comparison. As XCT of irradiated TRISO compacts is not a commonly implemented characterization technique, a significant portion of the report focuses on developed methodology and imaging conditions. A specialized sample shielding device was developed and fabricated specifically to limit received dose to staff during sample preparation for XCT and to minimize excess gamma radiation dose to sensitive electronic components with the utilized X-ray system. Significant penetration through the uranium oxycarbide fuel kernels by significantly hardening the X-ray beam with specialized proprietary filters acquired from Carl Zeiss NTS Ltd. The filter utilized resulted in an average X ray photon energy of ~110 keV which approaches uranium’s K-edge (~115 keV), maximizing penetration for a microfocus X-ray source. The gamma-radiation emitted from the irradiated AGR-3/4 TRISO compacts, has the same properties and mechanisms for interaction with matter as X-rays, thus the detection of gamma-radiation by the utilized X-ray detectors was initially a concern. However, although ?-rays did produce an observable signal on the X-ray detector, its contribution to the overall imaging results appeared negligible upon 3D reconstruction. The neglibile impact on the resulting 3D reconstructed volumes were likely the result of: (1) a significantly lower detection efficiency for ?-rays relative to X-rays; (2) An X-ray flux at the detector several orders of magnitude higher than that of the impinging ?-rays from the irradiated compacts. These results suggest that irradiated compacts with significantly higher radiation fields can be examined in the future if an acceptable route for sample handling and preparation can be determined. Additionally, the 3D imaging results of XCT can provide a valuable means of assessing compacts. While in many ways complimentary to traditional post irradiation examination techniques such as optical ceramography, XCT can provide additional insight into compact features traditionally difficult to discern directly from cross-sectional imaging alone. Preliminary analyses on kernel size, morphology (aspect ratio and sphericity), and kernel orientation were presented. Sphericity, a simple morphological shape descriptor, was utilized to screen for kernel extrusions within the high burnup compact. The number of kernel extrusions identified via XCT represented an approximate two-fold increase from the quantity of extruded particles observed (via optical ceramography) in adjacent compacts from the same irradiation capsule. While numerical analysis of the compact datasets was highly preliminary, initial results show promise for providing complimentary metrics to current AGR-3/4 PIE and potentially additional insight into the processes driving TRISO fuel degradation during reactor operation. Additional analyses to be performed at a later date include a more detailed examination of kernel size, kernel sphericity (and observed kernel extrusions), and sphericity. Given all particles can be observed in a single data volume possible correlation of spatial position with observed kernel features will also be made at a later date.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Investigation of divertor detachment induced through neon seeding and density ramp on HL-3

A new self-consistent 1D scrape-off layer model has been recently developed in BOUT++ framework, named SD1D, which includes equations for various particle species (e.g. main plasma, neutrals and impurities) and couples open databases like ADAS and AMJUEL. It is able to quickly and effectively simulate divertor detachment experiments. In this work, a typical detachment experiment (shot #6270) on HL-3 with neon seeding is simulated using the SD1D code. It is found that the target electron temperature and the target ion saturation current in the simulations are consistent with experimental results measured by Langmuir probes on the target plate. The variation of D α radiation intensity in the divertor is qualitatively similar to the measured D α signal. Following the experimental validations, different upstream densities are set in the simulations to study the impurity distribution under different plasma density conditions. It is found that increasing upstream density can be helpful for the control of the neon radiation front (closer to the target). In this work we also compare two detachment regimes in simulations. Based on the same initial experimental parameters (shot #6270) on HL-3, a scan of upstream density and a scan of neon seeding rate are carried out respectively. It is found that the role of atomic and molecular processes is different in the two detachment regimes. The current density roll-over is ascribed to a drop in the divertor ion source, and the variation of D α radiation intensity via different excitation channels is associated with the relevant collisional reaction sources.

BOUT++↗

A field programmable gate array-based timing and control system for the dynamic compression sector

A field programmable gate array (FPGA)-based timing and trigger control system has been developed for the Dynamic Compression Sector (DCS) user facility located at the Advanced Photon Source (APS) at Argonne National Laboratory. The DCS is a first-of-its-kind capability dedicated to dynamic compression science. All components of the DCS laser shock station—x-ray choppers, single-shot shutter, internal laser triggers, and shot diagnostics—must be synchronized with respect to the arrival of x rays in the hutch. An FPGA synchronized to the APS storage ring radio frequency clock (352 MHz) generates trigger signals for each stage of the laser and x-ray shutter system with low jitter. The developed FPGA-based control system was the first system used to control the laser and the shutter system since its commissioning, and it has been developing since then to improve the timing jitter. The system is composed of a Zynq FPGA, a debug card, line drivers, and a power supply. The delay and offsets of the trigger signals can be adjusted by using a user-friendly graphical user interface with high precision. Here, the details of the system architecture, timing requirements, firmware, and software implementation along with the performance evaluation are presented in this paper. The system offers low timing jitter (15.5 ps rms) with respect to the APS 352 MHz clock, suitable for the 100 ps (FWHM) x-ray bunch duration at the APS.

47 OTHER INSTRUMENTATION↗

Real-time interfacial electron dynamics revealed through temporal correlations in x-ray photoelectron spectroscopy

We present a novel technique to monitor dynamics in interfacial systems through temporal correlations in x-ray photoelectron spectroscopy (XPS) signals. To date, the vast majority of time-resolved x-ray spectroscopy techniques rely on pump–probe schemes, in which the sample is excited out of equilibrium by a pump pulse, and the subsequent dynamics are monitored by probe pulses arriving at a series of well-defined delays relative to the excitation. By definition, this approach is restricted to processes that can either directly or indirectly be initiated by light. It cannot access spontaneous dynamics or the microscopic fluctuations of ensembles in chemical or thermal equilibrium. Enabling this capability requires measurements to be performed in real (laboratory) time with high temporal resolution and, ultimately, without the need for a well-defined trigger event. The time-correlation XPS technique presented here is a first step toward this goal. The correlation-based technique is implemented by extending an existing optical-laser pump/multiple x-ray probe setup by the capability to record the kinetic energy and absolute time of arrival of every detected photoelectron. The method is benchmarked by monitoring energy-dependent, periodic signal modulations in a prototypical time-resolved XPS experiment on photoinduced surface-photovoltage dynamics in silicon, using both conventional pump–probe data acquisition, and the new technique based on laboratory time. The two measurements lead to the same result. The findings provide a critical milestone toward the overarching goal of studying equilibrium dynamics at surfaces and interfaces through time correlation-based XPS measurements.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Uncovering New Physics in the Cosmic Microwave Background: Developing Novel Theoretical Models and Machine-Learning-Powered Constraints

The search for evidence of new physics via its signatures in the cosmos is a cornerstone goal of the Office of High Energy Physics in the DOE Office of Science. Indeed, the current concordance cosmological model provides intriguing hints for beyond-the-standard-model (BSM) physics, such as dark matter and dark energy. Recently, a potential breakdown has appeared in this model, which could be initial evidence toward a further important revision in our fundamental theoretical understanding of cosmology. This breakdown is reflected in disagreements between inferences of the current expansion rate of the universe, H 0 (the Hubble constant), based on indirect, cosmological data (e.g., from the early universe) and based on direct, local measurements. Despite significant effort, a compelling new concordance cosmological model has yet to be found; achieving significant progress on this front was the first major focus of the project. Theoretical considerations indicate that if the observational discrepancies are not due to systematic errors, they strongly suggest new physics operating in the redshift range just prior to recombination, when cosmic microwave background (CMB) photons last scattered. Crucially, almost all such models produce unique signatures in the CMB temperature and polarization power spectra, which will be measured with unprecedented precision by ongoing and upcoming experiments, including the DOE-supported CMB-S4 project. However, these subtle hints of new physics must be uncovered from beneath a swath of Galactic and extragalactic foreground contamination. Current CMB analysis methods, although powerful, do not optimally infer the CMB power spectrum in the presence of non-Gaussian foregrounds. There is thus scope for theoretical improvement in this foundational challenge of cosmological inference, which formed the second major focus of the project. The primary objectives of the project were two-fold: (1) to develop new theoretical models in cosmology that can restore concordance amongst the full suite of cosmological data sets, thereby potentially providing evidence of novel BSM physics; (2) to develop new theoretical machinery to enable significant sensitivity improvements in searches for new physics in cosmology, particularly via the CMB power spectrum. The two objectives are intertwined, as the analysis methodology improvements in (2) will enable the tightest possible constraints on the signatures of new physics predicted by the novel scenarios in (1). The theoretical approaches to restore concordance focused on models involving novel scalar field dynamics in the pre-recombination universe (the “early dark energy” scenario and modifications thereof), as well as couplings between this field and other components in the standard cosmological model, such as dark matter. We also studied a model featuring a generalization of the decaying dark matter scenario, in which a sub-component of dark matter converts into dark radiation at late times in cosmic history. While these ideas are mostly driven by phenomenological considerations, this tactic has proven extremely successful in cosmology throughout the past few decades, including in the early history of evidence for dark matter and dark energy. The new theoretical machinery envisioned in (2) is undergirded by developments in signal processing and machine learning, which will enable improvements in CMB power spectrum estimation in the presence of non-Gaussian foreground contaminants. In turn, this will yield optimal sensitivity in searches for new physics in the CMB, by maximizing the cosmological information that is extracted from this observable. The most ambitious outcome of this work would be the construction of a new cosmological model that restores concordance amongst data sets. Although the individual models studied here did not fully achieve that goal, significant progress in narrowing down the model space was made, as described below. Moreover, the outcome of the methodological improvements in (2) will significantly impact a wide range of theoretical cosmology, by enabling the tightest possible constraints on any model that leaves novel signatures in the CMB temperature and polarization power spectra.

79 ASTRONOMY AND ASTROPHYSICS↗

Pulsed Lidar for Measurement of C02 Concentrations for the ASCENDS Mission - Update

We have been developing a laser-based sounding technique for the remote measurement of the tropospheric CO2 concentrations from orbit for NASA is ASCENDS mission. The mission's goals are to provide measurements of tropospheric CO2 abundance with global-coverage, a few hundred km spatial and monthly temporal resolution. These are needed to better understand CO2 fluxes and the processes that regulate CO2 storage by the land and oceans. For the lIP, we are developing and demonstrating the lidar techniques and key lidar technology that will permit measurements of the CO2 column abundance in the lower troposphere from aircraft. Our final goal is to demonstrate the key capabilities needed for a space lidar and mission approach for the ASCENDS mission. We use a pulsed lidar technique, which is much less sensitive to errors from cloud and atmospheric scattering and to noise from solar background. It allows continuous measurements of CO2 mixing ratio in the lower troposphere during day and night. Our approach uses the 1570nm CO2 band and a two-wavelength laser absorption spectrometer, which continuously measures at nadir from a circular polar orbit. It directs the narrow co-aligned laser beams from the instrument's lasers toward nadir, and measures the energy of the laser echoes reflected from land and water surfaces. It uses a pair of tunable laser transmitters, which allowing measurement of the extinction from a single selected CO2 absorption line in the 1570 nm band and from a line pair in the Oxygen A-band near 765 nm. These regions have temperature insensitive absorption lines are free from interference from other gases. The lasers pulse at 10KHz, use tunable diode seed lasers followed by laser amplifiers, and have MHz spectral widths. During the measurement the lasers are stepped across the selected lines at a kHz rate. The receiver uses a 1-m class telescope and photon sensitive detectors and measures the background light and energies of the laser echoes from the surface. The extinction and column densities for the CO2 and O2 gases are estimated from the ratio of the on and off line echo pulse energies via the integrated path differential absorption (IPDA) technique. Our technique exploits the atmospheric pressure broadening of the lines to weight the measurement sensitivity to the atmospheric column below 5 km. Pulsed laser signals, time gated receiver are used to isolate the surface laser echo signals and to exclude photons scattered from clouds and aerosols. We have successfully demonstrated many key aspects of the approach and lidar technology in the laboratory. We have demonstrated CO2 column measurements in airborne flights during the summers of 2009 and 2010. These included measurements from 3-l3 km altitudes made over a variety of surfaces and through thin and broken clouds. We demonstrated initial airborne measurements of O2 column density to 10 km altitudes during the summer 2010 flights. More details approach, key technologies, and demonstration measurements will be given in the presentation.

Abshire, James↗