Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “peak load”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Smarter building start – A distributed solution

A significant focus of research and new technologies for reducing energy use in buildings is on operating the systems more efficiently during the times when the systems are active. However, there is a large potential for energy savings in determining the periods when the systems should or should not be active. This scheduling aspect of operation is often overlooked even though relatively simple solutions can unlock substantial energy savings. In this paper we describe a smart building start (SBS) algorithm that considers multiple zones in a building to determine individual schedules for room controllers as well as the central systems based on solving a simple optimization problem. Application of the SBS algorithm to multiple interconnected systems enables a staggered start-up that minimizes peak loads and also ensures comfort is within a target range with minimal system run time. The SBS algorithm extends the capability of traditional optimal start and is designed to be simple to deploy and robust. Simulation results as well as results from tests in a real building with a VAV system are presented. The presented algorithm is applicable to any type of building with a zonal or multi-zone HVAC system. To function, it needs to be able to change setpoints in rooms and monitor room temperatures, as well as, if desired, turn the central system on or off.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Performance evaluation of underground thermal storage integrated dual-source heat pump systems

The increasing demand for electricity stresses the existing electric grids. Buildings consume 73% of all U.S. electricity and are responsible for 30% of U.S. greenhouse gas emissions. Integrating thermal energy storage (TES) in building heating/cooling systems, which consume considerable electricity, can mitigate the challenges to electric grids. Here, this study reports on a novel thermal energy storage device integrated heat pump system to reshape the building electricity demand profile while maintaining thermal comfort. The annual performance of the proposed system has been evaluated through a dynamic system simulation with high fidelity in the Modelica platform. The dynamic model of the novel hybrid component named ‘dual purpose underground thermal battery’ was developed and validated. It was then incorporated into the system model. Given a time-of-use tariff, a rule-based control strategy was designed to shift the electric demand and switch the heat pump source for a typical single-family house in different climate zones of the United States. The system performance of the new TES-integrated dual-source heat pump was compared with that of a conventional air-source heat pump system. The results indicate that the proposed system can reduce the annual HVAC electricity cost by up to 52% while saving 45.2% on electricity consumption. In the Northern areas, the annual peak load of the HVAC system can be reduced by 64.9%. However, this reduction is less in the Southern areas as the system’s higher efficiency in winter dominates the overall energy-saving potential.

25 ENERGY STORAGE↗

Bayesian calibration and uncertainty quantification of a rate-dependent cohesive zone model for polymer interfaces

In this work we present a rate-dependent cohesive zone model for the fracture of polymeric interfaces and performs a Bayesian calibration, an uncertainty quantification, and a sensitivity analysis for the model. The proposed cohesive zone model accounts for both reversible elastic and irreversible rate-dependent separation sliding deformation at the interface. The viscous dissipation due to the irreversible opening at the interface is modeled using elastic-viscoplastic kinematics that incorporates the effects of strain rate. Inverse calibration of parameters for such complex models through trial and error is challenging due to the large number of parameters of the model. Moreover, the calibrated parameter values are often non-unique and uncertain when the available experimental data is limited. To tackle this challenge, we employ a Bayesian calibration approach to identify parameters from experimental data, the resulting parameters significantly enhance the accuracy of the model. To quantify the uncertainty associated with the inverse parameter estimation, a modular Bayesian approach is employed to calibrate the unknown model parameters, accounting for the parameter uncertainty of the cohesive zone model. The advantages of the Bayesian calibration over a deterministic parameter fit are demonstrated. Further, to quantify the model uncertainties, such as incorrect assumptions or missing physics, a discrepancy function is introduced, which significantly improves the model’s prediction. Finally, the total uncertainty of the model is quantified in a predictive setting. A sensitivity analysis is performed to assess how changes in the input variables of the model affect the peak load, facilitating the identification of a concise set of highly influential parameters. The present approach can be used for calibration and uncertainty quantification for other complex computational mechanics models. It should also facilitate the designing of interface materials under uncertainty.

42 ENGINEERING↗

Influence of alkali-silica reaction on the shear capacity of reinforced concrete beams with minimum transverse reinforcement

A growing number of critical concrete infrastructure are affected by alkali-silica reaction (ASR) damage such as the Seabrook Nuclear Power Plant in New Hampshire, Parker arch-gravity dam in Arizona, and several highway bridges in California and Texas. ASR causes expansion and cracking and degrades the concrete mechanical properties. Despite a wealth of material level studies there is still limited large-scale experimental data regarding the effects of ASR on reinforced concrete (RC) members. Due to the brittle nature of the shear failure in RC structures, this study focuses on the shear response of full-scale ASR damaged RC beams with minimum shear reinforcement. Six RC beams were built with different levels of ASR susceptibility and conditioned in different environments during which continuous expansion monitoring was performed. The beams all contained reactive fine aggregate (sand) and two of them had additional alkali, 1.25% by weight of cement, to accelerate ASR. The highest expansion rate of the beams happened during the first 150 days and the expansions stayed constant after 240 days and 330 days for beams conditioned in outdoor and laboratory conditions, respectively, until the last measurement at 575 days. The highest expansion, 0.4%, was seen in the beams with additional alkali and conditioned outside with regular water spray. Out of the six beams, three were selected at different levels of ASR damage and two shear tests were performed on the minimally reinforced spans close to the ends of each beam. Results indicated that beams gain shear strength from ongoing cement hydration in the presence of moisture for ASR expansions less than 0.2%. Compared to one of the beams with 0.2% ASR expansion, one of the other samples with 0.4% expansion lost 6% of its shear strength, 25% of its shear stiffness, and showed about two times larger shear cracks and shear deformations at peak load. Finally, the shear reinforcement yielded at 20% less load in the beam with 0.4% expansion compared to the beam with 0.2% expansion.

42 ENGINEERING↗

Electricity market design for generator revenue sufficiency with increased variable generation

Here, we present a computationally efficient mixed-integer program (MIP) that determines optimal generator expansion decisions, and hourly unit commitment and dispatch in a power system. The impact of increasing wind power capacity on the optimal generation mix and generator profitability is analyzed for a test case that approximates the electricity market in Texas (ERCOT). We analyze three market policies that may support resource adequacy: Operating Reserve Demand Curves (ORDC), Fixed Reserve Scarcity Prices (FRSP) and fixed capacity payments (CP). Optimal expansion plans are comparable between the ORDC and FRSP implementations, while capacity payments may result in additional new capacity. The FRSP policy leads to frequent reserves scarcity events and corresponding price spikes, while the ORDC implementation results in more continuous energy prices. Average energy prices decrease with increasing wind penetration under all policies, as do revenues for baseload and wind generators. Intermediate and peak load plants benefit from higher reserve prices and are less exposed to reduced energy prices. All else equal, an ORDC approach may be preferred to FRSP as it results in similar expansion and revenues with less extreme energy prices. A fixed CP leads to additional new flexible NGCT units, but lower profits for other technologies.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Thermal property characterization of phase change materials in building applications: A systematic review of fundamentals, recent progress, and future directions

Phase change materials (PCMs) can reduce building peak loads and enable demand-responsive thermal energy storage (TES), but their deployment depends on reliable measurement and interpretation of thermal properties across laboratory, intermediate, and application scales. Here, this review systematically examines characterization methods, testing protocols, and recent advances for neat PCMs and PCM composites, emphasizing thermal conductivity, enthalpy-related properties (phase change temperature, latent heat, specific heat), and cycling stability. For thermal conductivity, we compare steady-state and transient techniques and note limitations when phase transition and contact resistance affect measurements. For enthalpy–temperature characterization, we discuss differential scanning calorimetry together with intermediate- and bulk-scale methods, including T-history, heat flow meter testing, and three-layer calorimetry (3LC), to generate application-relevant enthalpy–temperature profiles. Cycling stability is organized into four experimental families: thermoelectric–air, fully thermoelectric, water-bath, and in situ chamber approaches, with attention to separating reversible supercooling from true degradation such as phase segregation. We highlight emerging noncontact diagnostics, including infrared thermography and embedded sensing, for spatially resolved validation and multiscale interpretation. Finally, we review the growing use of AI and machine learning for property prediction, inverse characterization from experimental signals, and real-time state estimation in building-integrated TES. Key needs include harmonized protocols, interlaboratory benchmarking, uncertainty reporting, and metadata-rich datasets to accelerate reproducible PCM qualification for grid-flexible buildings.

AI↗

Modeling and Experimental Validation of a Direct-Contact Counter-Flow Fluidized Bed Heat Exchanger for Thermal Energy Storage (TES) Applications

Particle-based thermal energy storage (TES) systems are an emerging energy storage technology. The technological advances have reduced costs, making TES more competitive and reliable in the marketplace but an efficient and reliable operation is heavily dependent on coherent heat transfer between air to particles or vice versa. The particle-based TES technologies provide an intermediate system that can store energy for short (0-10 h), long (10-200 h) and seasonal (> 200 h) timescales. The TES systems store energy by converting electricity to thermal energy; electricity can be directly sourced intermittent generation technologies and/or the grid, helping manage peak loads and other mismatches in supply and demand. The overall efficiency of the TES system depends on the performance of system components (particle storage silos and particle transfer mechanism etc.). The particle heat exchanger is one of the key system components that affects the system efficiency. The pressurized fluidized bed heat exchanger (PFB HX) performance is challenging to predict due to the chaotic behavior of particle and fluid interaction. This research presents a computational study of a novel direct-contact, counter-flow and air-to-particles PFB HX, that contributes in advancing the particle-based long-duration TES technologies. For the current analysis an unsteady Eulerian-Eulerian CFD model was developed and validated against experiments performed at the National Laboratory of the Rockies for two particle sizes (600 ..mu..m and 825 ..mu..m ). Following validation, parametric simulations were conducted to evaluate the effects of interphase drag models (Syamlal-O'Brien and Gidaspow), particle size, bed height and the influence of a frictional-viscosity term on hydrodynamics and heat transfer between the air & particles. The key findings from the analysis are: (1) for the studied operating window Syamlal-O'Brien provides superior agreement with measured gas temperatures (errors generally < 10%) while Gidaspow shows large deviations for the coarse particle case; (2) model predictions are most sensitive in the lower 0.2 m above the air distributor where bubble initiation and local mixing dominate interphase heat transfer; (3) representation of the distributor (number of inlet ports) materially affects predicted local mixing and temperature stratification; and (4) the Eulerian-Eulerian framework reproduces bulk thermal trends but shows regime dependent limitations for coarse particles, motivating mesoscale informed closures for scale-up analysis for future studies. These results provide validated guidance for drag selection and distributor design in particle-based thermal energy storage applications. Collectively, the validated model and parametric results quantify key drivers of PHB-HX performance and provide practical guidance for design and optimization. The results provide confidence in the model predictability and provide a step forward to improve on heat exchange performance. The demonstrated performance and modeling approach support the deployment and further development of this novel PHB-HX concept for robust, particle-based long-duration thermal energy storage systems.

25 ENERGY STORAGE↗

Fracture toughness and crack propagation in LX-17 and PBX 9502 insensitive high explosives

High explosive materials, and in particular insensitive high explosive (IHE) materials, are of significant interest. TATB-based LX-17 and PBX 9502 are two IHE’s and mechanical properties are an important metric of performance. In this work we present, for the first time, a study of fracture as a function of temperature and displacement rate and starter crack length on billet pressed IHE materials using a standard three point bend technique. We demonstrated that the technique can yield consistent results over time by measuring samples from the same lots 4 years later and observed that the fracture toughness of LX-17 and PBX 9502 are similar. We also determined the temperature dependence for different starter crack lengths and found that the fracture toughness generally decreases with larger starter crack sizes and temperatures. For the LX-17, where a wide temperature range of -60 C to 50 C was investigated, the impact of temperature on fracture toughness between -20 C and 23 C was less than expected. For the PBX 9502 we observed the difference in fracture toughness values between -20 C and 23 C did depend on the particular lot, and also there was a tendency of the fracture toughness to scale with the tensile strength. We also investigated the effect of a lower displacement rate and observed that while the impact on the fracture toughness was relatively small, the samples surprisingly did not break (fail) after exceeding the peak load. We took advantage of this to perform x-ray computed tomography (CT) of the samples to image crack propagation in the intact samples. We observed that cracks were generally straight and unaffected by the microstructure in the LX-17, in contrast to the PBX 9502 where the direction of the cracks would frequently change and were likely influenced by the underlying microstructure.

36 MATERIALS SCIENCE↗

Effects of processing temperature, pressure, and fiber volume fraction on mechanical and morphological behaviors of fully-recyclable uni-directional thermoplastic polymer-fiber-reinforced polymers

This work explores a type of composite called thermoplastic polymer-fiber-reinforced polymers (PFRPs), often referred to as self-reinforced composites (SRCs). A representative PFRP was exemplified using unidirectional (UD) ultra-high-molecular-weight polyethylene (UHMWPE) fibers embedded in a high-density polyethylene (HDPE) matrix. The effects of compression molding temperature and pressure on the mechanical and morphological behaviors of the filament-wound PFRPs with various fiber volume fractions (V f ) were experimentally investigated. The results elucidate the evolution of morphologies and tensile properties of the PFRPs due to thermal melting, fiber misalignment from pressure, and (V f )-induced structural variance, which has not been comprehensively reported yet. The highest specific tensile strength and modulus of the PFRP laminae reach 600 MPa/(g/cm 3 ) and 31 GPa/(g/cm 3 ), respectively. These properties are comparable to glass-/aramid-fiber-reinforced polymers (GFRPs, GFRTPs, AFRPs, and AFRTPs), with PFRPs exhibiting better ductility (specific strain at peak load ≈ 4%/(g/cm 3 )) than other common polymer composites. The motivation for this work was the high recyclability of PFRPs, which can be recycled by melting both the fibers and the matrix, and then reshaped them for re-manufacturing composites to maximize the efficiency in material reuse. This process simplifies the implementation of closed-loop recycling, re-manufacturing, and reuse to support sustainability in composites. This work aims to contribute to advancing thermoplastic PFRPs for their potential applications in various industries.

36 MATERIALS SCIENCE↗

Microstructure and mechanical properties of ultrasonic spot welding of AA7075-T6 and A380 casting aluminum alloy

Ultrasonic spot welding (USW) was employed to join AA7075-T6 and casting Al alloy A380. Under a constant welding power, the influence of the welding time duration (from 1 s to 3 s) on peak temperature, microstructure, hardness, and mechanical strength of the joints were studied. It was found that the peak temperature increased with welding time. A sound solid-state metallurgical bonding was obtained at the joint interface. The cracks occurred at the edge of the joints were eventually eliminated as the welding time increased. A layer of refined grains formed in A380 adjacent to the bonding line. Further, hardness reduction occurred in AA7075 at the joint interface and the degree of hardness reduction and the volume increased with the peak temperature. By increasing welding time, lap shear tensile tests show that the peak load increased from 5.3 kN to 6.55 kN. The corresponding interfacial shear strength ranged from 96.29 MPa to 99.72 MPa, lower than the shear strength of both base materials (331 MPa for AA7075 and 185 MPa for A380). All joint samples exhibited interfacial fracture after lap shear tensile testing, with a thin layer of A380 remnant attached to AA7075 at the center of the fractured surface.

36 MATERIALS SCIENCE↗

Impacts of variable renewable energy on wholesale markets and generating assets in the United States: A review of expectations and evidence

Here, we synthesize available literature, data, and analysis on the degree to which growth in variable renewable energy (VRE) has impacted or might in the future impact bulk power system assets, pricing, and costs in the United States. Most studies of future scenarios indicate that VRE reduces wholesale energy prices and capacity factors of thermal generators. Traditional baseload generators are more exposed to these changing market conditions than low-capital cost and more flexible intermediate and peak-load generators. From analysis of historical data we find that VRE is already influencing the bulk power market through changes in temporal and geographic patterns areas with higher levels of VRE. The most significant observed impacts have concentrated in areas with significant VRE and/or nuclear generation along with limited transmission, with negative pricing also often occurring during periods with lower system-wide load. So far, however, VRE, has had a relatively modest impact on historical average annual wholesale prices across entire market regions, at least in comparison to other drivers. The reduction of natural gas prices is the primary contributor to the decline in wholesale prices since 2008. Similarly, VRE impacts on thermal plant retirements have been limited and there is little relationship between the location of recent retirements and VRE penetration levels. Finally, although impacts on wholesale prices have been modest so far, impacts of VRE on the electricity market will be more significant under higher VRE penetrations.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

WEC fault modelling and condition monitoring: A graph-theoretic approach

The nature of wave resources usually requires wave energy converter (WEC) components to handle peak loads (i.e., torques, forces, and powers) that are many times greater than their average loads, accelerating equipment degradation. Moreover, due to their isolated nature and harsh operating environment, WEC systems are projected to possess high operations and maintenance (O&M) cost, i.e., around 27% of their leveled cost of energy. As such, developing techniques to mitigate these costs through the application of condition monitoring and fault tolerant control will significantly impact the economic feasibility of grid connected WEC power. Toward this goal, models of faulty components are developed in the open source modeling platform, WEC-Sim, to estimate the performance and measurable states of a WEC operating with likely device and sensor failures. Two types of faulty component models are then applied to a point absorber WEC model with basic controller damping and spring forces. Resulting changes in device behavior are recorded as a benchmark, and a graph-theoretic approach is proposed for fault detection and identification utilizing multivariate time series. Simulation results demonstrate that these faults can greatly affect the WEC performance, and that the proposed method can effectively detect and classify different types of faults.

16 TIDAL AND WAVE POWER↗

Quantification of storage required for preserving frequency security in wind‐integrated systems

Abstract The penetration of wind power generation into the power grid has been accelerated in recent times due to the aggressive emission targets set by governments and other regulatory authorities. Although wind power has the advantage of being environment‐friendly, wind as a resource is intermittent in nature. In addition, wind power contributes little inertia to the system as most wind turbines are connected to the grid via power electronic converters. These negative aspects of wind power pose serious challenges to the frequency security of power systems as penetration increases. In this work, an approach is proposed where an energy storage system (ESS) is used to mitigate frequency security issues of wind‐integrated systems. ESSs are well equipped to supply virtual inertia to the grid due to their fast‐acting nature, thus replenishing some of the energy storage capability of displaced inertial generation. In this work, a probabilistic approach is proposed to estimate the amount of inertia required by a system to ensure frequency security. Reduction in total system inertia due to the displacement of conventional synchronous generation by wind power generation is considered in this approach, while also taking into account the loss of inertia due to forced outages of conventional units. Monte Carlo simulation is employed for implementing the probabilistic estimation of system inertia. An ESS is then sized appropriately, using the system swing equation, to compensate for the lost inertia. The uncertainty associated with wind energy is modeled into the framework using an autoregressive moving average technique. Effects of increasing the system peak load and changing the wind profile on the expected system inertia are studied to illustrate various factors that might affect system frequency security. The proposed method is validated using the IEEE 39‐bus test system.

17 WIND ENERGY↗

Double nanosecond pulses generation in ytterbium fiber laser

Double pulse generation mode for nanosecond ytterbium fiber laser was developed. Two sequential 60-200 ns laser pulses with variable delay between them were generated by acousto-optic modulator opening with continuous diode pumping. A custom radio frequency generator was developed to produce two sequential “opening” radio pulses with a delay of 0.2–1 μs. It was demonstrated that double pulse generation did not decrease the average laser power while providing the control over the laser pulse power profile. Surprisingly, a greater peak power in the double pulse mode was observed for the second laser pulse. Laser crater studies and plasma emission measurements revealed an improved efficiency of laser ablation in the double pulse mode.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Superradiant Ka-band Cherenkov oscillator with 2-GW peak power

The generation of a 2-GW microwave superradiance (SR) pulses has been demonstrated at 29-GHz using a single-mode relativistic backward-wave oscillator possessing the beam-to-wave power conversion factor no worse than 100%. A record-breaking radiation power density in the slow-wave structure (SWS) of ∼1.5 GW/cm{sup 2} required the use of high guiding magnetic field (7 T) decreasing the beam losses to the SWS in strong rf fields. Despite the field strength at the SWS wall of 2 MV/cm, a single-pass transmission mode of a short SR pulse in the SWS allows one to obtain extremely high power density in subnanosecond time scale due to time delay in the development of the breakdown phenomena.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Elastic wave suppression through additively manufactured petal lattice metamaterials

Lattice-core sandwich structure metamaterials are lightweight alternatives to monolithic materials that can present better mechanical, thermal, and energy dampening performance. Manufacturing lattice metamaterials to follow curved surfaces can pose a challenge, as the lattices rely on their geometric orientation to the substrate for their mechanical properties. This work rationally designed a lattice structure where the surface is broken up into “petals” connected to the underlying lattice, which localizes the petals’ impact response. This design opens a pathway for implementation of lattice-core sandwich structures onto complex surface geometries. These petal structures were evaluated for their energy absorption efficiency experimentally by utilizing pressure waves generated with nanosecond lasers and computationally via finite element modeling. The lattice structures exhibited a two-orders-of-magnitude decrease in transmitted pressure compared to their constituent steel at equivalent mass. Furthermore, localizing energy absorption into petal structures provided a 44% reduction in peak load compared to a continuous “single-petal” design.

Sarracino, Alex↗

Vanadate lasers with {sigma}-polarised radiation

Luminescent and lasing properties at the {sup 4}F{sub 3/2} - {sup 4}I{sub 11/2} transition of {alpha}-cut Nd:YVO{sub 4}, Nd:GdVO{sub 4}, Nd:Gd{sub 1-x}Y{sub x}VO{sub 4} and Nd:Sc{sub 1-x}Y{sub x}VO{sub 4} vanadate crystals are experimentally studied for {pi}- and {sigma}-polarisations. Polarisation dependences of the lasing characteristics of passively Q-switched Nd:YVO{sub 4}, Nd:Gd{sub 1-x}Y{sub x}VO{sub 4} and Nd:Sc{sub 1-x}Y{sub x}VO{sub 4} lasers with Cr{sup 4+}:YAG and V{sup 3+}:YAG Q-switches are investigated. It is shown that the laser wavelengths are different for {pi}- and {sigma}-polarizations. The best characteristics are achieved for the Nd:YVO{sub 4} laser with a Cr{sup 4+}:YAG passive saturable absorber for {sigma}-polarisation (minimum pulse duration shorter than 3 ns, maximum peak power up to 10 kW, maximum peak energy {approx}35 {mu}J at a slope efficiency up to 32%). (lasers)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Setting the Smart Solar Standard: Collaborations Between Hawaiian Electric and the National Renewable Energy Laboratory

Driving through many neighborhoods of Hawai'i, it is hard to miss the nearly ubiquitous rooftop solar photovoltaic (PV) systems that have popped up during the past eight years or so. Relatively high electricity costs associated with island grids, coupled with various incentives, have made it cost-effective to install solar over the last eight years, as evidenced by the PV-deployment chart in Figure 1. On the most populous island, O'ahu, the PV nameplate acgenerating capacity of 502 MW totals nearly half of the annual peak load for the entire island, which is 1.1 GW . Of that 502 MW of PVs, 54% is from private rooftop solar-nearly 50,000 residences or roughly one of every three single family homes. But Hawaiian Electric, the local utility, has no way to monitor or control the PV generation, even for most nonresidential systems. This means that on sunny days, up to approximately half of the PV generation is outside of the utility's control. This poses many challenges for utility planners and operators-challenges that Hawaiian Electric has been working diligently to address, along with various partners, notably the U.S. Department of Energy (DOE), the National Renewable Energy Laboratory (NREL), and its Energy System's Integration Facility (ESIF). This article describes how Hawaiian Electric has worked with engineers in NREL's Power Systems Engineering Center to improve the way its grid operates with very high levels of distributed PVs, largely by changing the way the PV inverters are operated.

14 SOLAR ENERGY↗