Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “peak flows”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Performance Impact of Fast Flow Paths Through Grout Monoliths Used for Radioactive Waste Disposal - 13224

Empty HLW handling and storage tanks at SRS and INL contain residual radioactivity; these tanks are being stabilized with cementitious grout during closure operations. The US NRC directed the Center for Nuclear Waste Regulatory Analyses (CNWRA{sup R}) to develop physical analogs of cementitious grout monoliths to investigate their potential to form fast flow pathways such as macro-cracks, separations between grout lifts, and annuli around pipes, supports, and along tank walls. CNWRA developed and tested 15 55-gal-drum-scale specimens and 2 larger specimens of tank-filling cementitious grout, and 9 specimens of pipe-filling grout. These experiments demonstrated that the size of fast flow pathways that develop and the peak temperatures attained during hydration are proportional to the scale of the specimen, and that annular apertures and bulk grout permeability generally increased with time post-placement. Cracks developed overnight following placement of each grout lift in the largest specimen, but developed more slowly in smaller specimens, perhaps due to a ∼20 deg. C difference in peak temperatures, which influence the thermal gradients that can induce cracking. Plastic and drying shrinkage commonly led to poor grout-to-metal and grout-to-grout bonding. Cracks, annular gaps, and grout flow lobe seams transmitted fluids during injection testing. Macro-scale flow pathways such as these are not readily observed in bench-scale specimens of cementitious tank grout. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Overall and blade element performance of a 1.20 pressure ratio fan stage with rotor blades reset -7 deg

A 51-cm-diam model of a fan stage for short haul aircraft was tested in a single stage compressor research facility. The rotor blades were set 7 deg toward the axial direction (opened) from the design setting angle. Surveys of the air flow conditions ahead of the rotor, between the rotor and stator, and behind the stator were made over the stable operating range of the stage. At the design speed and a weight flow of 30.9 kg/sec, the stage pressure ratio and efficiency were 1.205 and 0.85, respectively. The design speed rotor peak efficiency of 0.90 occurred at a flow rate of 32.5 kg/sec.

Lewis, G. W., Jr.↗

Hypersonic flows as related to the national aerospace plane

The study in the last 6 months has observed a clear evidence that the current two-equation models tend to under-predict flow separation and over-predict heat transfer rate near flow re-attachment regions. In hypersonic flow calculations, these model deficiencies appear to be even more pronounced. This is particularly true in the incapability of the model to predict the extent of the flow separation. Two major deficiencies of the current two-equation models in predicting complex hypersonic flows have been reported, i.e., under-prediction of flow separation and over-prediction of peak heat transfer rate. Two modifications to the k - epsilon model were reported and tested over a range of flows. Based on our limited study, the modified models have been found to give better agreements in both surface pressure and heat transfer predictions for several complex shock-wave boundary-layer interaction flows. However, in order to confirm our observation, more calculations will be performed in the future study covering a wider range of flows and conditions than reported here.

Kussoy, Marvin↗

Peak Load Management in Distribution Systems Using Legacy Utility Equipment and Distributed Energy Resources

The ability to perform peak load management in distribution systems has several benefits for utilities, including reduced demand charges and improved reliability, efficiency, and utilization of the network infrastructure. This paper demonstrates the coordinated operation of an advanced distribution management system (ADMS) and a distributed energy resource management system (DERMS) to achieve peak load management using a realistic laboratory test bed. A commercial ADMS reduces the peak demand by reducing system voltages using a dynamic voltage regulation (DVR) application. A prototype DERMS-based on real-time optimal power flow-controls distributed battery energy storage systems to further reduce the feeder power. Results from the experiments conducted using a model of a real distribution feeder show that the coordinated operation of the ADMS and DERMS is effective in accomplishing peak load management.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Redshift space correlations and scale-dependent stochastic biasing of density peaks

We calculate the redshift space correlation function and the power spectrum of density peaks of a Gaussian random field. Our derivation, which is valid on linear scales k < or approx. 0.1 hMpc{sup -1}, is based on the peak biasing relation given by Desjacques [Phys. Rev. D, 78, 103503 (2008)]. In linear theory, the redshift space power spectrum is P{sub pk}{sup s}(k,{mu})=exp(-f{sup 2{sigma}}{sub vel}{sup 2}k{sup 2{mu}2})[b{sub pk}(k)+b{sub vel}(k)f{mu}{sup 2}]{sup 2}P{sub {delta}(k)}, where {mu} is the angle with respect to the line of sight, {sigma}{sub vel} is the one-dimensional velocity dispersion, f is the growth rate, and b{sub pk}(k) and b{sub vel}(k) are k-dependent linear spatial and velocity bias factors. For peaks, the value of {sigma}{sub vel} depends upon the functional form of b{sub vel}. When the k dependence is absent from the square brackets and b{sub vel} is set to unity, the resulting expression is assumed to describe models where the bias is linear and deterministic, but the velocities are unbiased. The peak model is remarkable because it has unbiased velocities in this same sense--peak motions are driven by dark matter flows--but, in order to achieve this, b{sub vel} must be k dependent. We speculate that this is true in general: k dependence of the spatial bias will lead to k dependence of b{sub vel} even if the biased tracers flow with the dark matter. Because of the k dependence of the linear bias parameters, standard manipulations applied to the peak model will lead to k-dependent estimates of the growth factor that could erroneously be interpreted as a signature of modified dark energy or gravity. We use the Fisher formalism to show that the constraint on the growth rate f is degraded by a factor of 2 if one allows for a k-dependent velocity bias of the peak type. Our analysis also demonstrates that the Gaussian smoothing term is part and parcel of linear theory. We discuss a simple estimate of nonlinear evolution and illustrate the effect of the peak bias on the redshift space multipoles. For k < or approx. 0.1 hMpc{sup -1}, the peak bias is deterministic but k dependent, so the configuration-space bias is stochastic and scale dependent, both in real and redshift space. We provide expressions for this stochasticity and its evolution.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Performance of 1380 foot per second tip-speed axial-flow compressor rotor blade tip solidity of 1.5

This presents the aerodynamic design parameters along with the overall and blade element performance of an axial-flow compressor rotor designed to study the effects of blade solidity on efficiency and stall margin. At design speed the peak efficiency was 0.892 and occurred at an equivalent weight flow of 65.0 lb/sec. The total pressure ratio was 1.83 and the total temperature ratio was 1.215. Design efficiency, weight flow, pressure ratio, and temperature ratio were 0.824, 65.3, 1.65, and 1.187, respectively. Stall margin for design speed was 10 percent based on the weight flow and pressure ratio values at peak efficiency and just prior to stall.

Ball, C. L.↗

Performance of a 1380-foot-per-second-tip-speed axial-flow compressor rotor with a blade tip solidity of 1.3

Aerodynamic design parameters are presented along the overall and blade element performance, of an axial flow compressor rotor designed to study the effects of blade solidity on efficiency and stall margin. At design speed the peak efficiency was 0.844 and occurred at an equivalent weight flow of 63.5 lb/sec with a total pressure ratio of 1.801. Design efficiency, pressure ratio, and weight flow 0.814, 1.65, and 65.3(41.1 lb/sec/sq ft of annulus area), respectively. Stall margin for design speed was 6.4 percent based on the weight flow and pressure ratio values at peak efficiency and just prior to stall.

Hager, R. D.↗

Aerodynamic performance of a 1.25-pressure-ratio axial-flow fan stage

Aerodynamic design parameters and overall and blade-element performances of a 1.25-pressure-ratio fan stage are reported. Detailed radial surveys were made over the stable operating flow range at rotative speeds from 70 to 120 percent of design speed. At design speed, the measured stage peak efficiency of 0.872 occurred at a weight flow of 34.92 kilograms per second and a pressure ratio of 1.242. Stage stall margin is about 20 percent based on the peak efficiency and stall conditions. The overall peak efficiency for the rotor was 0.911. The overall stage performance showed no significant change when the stators were positioned at 1, 2, or 4 chords downstream of the rotor.

Moore, R. D.↗

Tube entrance heat transfer with deposit formation

A two-peak wall temperature profile was observed while flowing a kerosene-type gas turbine fuel through a direct-resistance heated tube at an entrance Reynolds number of about 1500. The downstream peak gradually diminished as deposits formed inside the tube, and only one peak remained after seven hours. The observation is explained qualitatively on the basis of analytical and experimental results reported in the literature. It is shown that the temperature profile can be divided into five regions: development of the thermal boundary layer, appearance of the secondary flows, fully developed thermal boundary layer, transition to turbulent flow, and turbulent flow. Deposits increase the tube roughness and reduce the length required for laminar-turbulent transition.

Szetela, E. J.↗

Experimental characterization of a triply periodic minimal surface PCM-to-air thermal energy storage device

Here, the expansion of energy production has intensified research into thermal energy storage (TES) to manage variability and improve system efficiency. Heat exchanger design is critical to achieving high power densities in TES systems. This study presents a high-surface-area phase change material (PCM)-to-air heat exchanger fabricated via resin-based stereolithography with a novel gyroid-based geometry tailored for enhanced performance. Material properties of the commercial PCM and resin were characterized using analytical techniques. A controlled air loop was used to evaluate heat transfer and pressure drop at various flow rates and inlet temperatures. Results show a strong dependence on the inlet temperature difference (ΔT) relative to the PCM melting point. During charging at the highest flow rate, increasing the inlet air temperature from ΔT = 5 °C to 20 °C above the melting point increased the average heat transfer rate by 187%. During discharging, decreasing the inlet temperature by the same ΔT below the melting point led to a 232% increase. Notably, the high-surface-area design enabled nearly symmetric charging and discharging behavior, a novel result for PCM-based TES systems which are often restricted by natural convection and other effects. The overall heat transfer coefficient was calculated and compared to values from standard design correlations. The maximum thermal effectiveness reached 95% at ΔT = 20 °C and a moderate flow rate of 34 m 3 /h. Peak coefficients of performance (COP) of 7 during charging and 6.4 during discharging were observed at ΔT = 20 °C and a low flow rate of 20 m 3 /h. These results demonstrate the viability of additively manufactured geometries for advanced TES applications.

25 ENERGY STORAGE↗

SWIFT X-RAY TELESCOPE TIMING OBSERVATIONS OF THE BLACK HOLE BINARY SWIFT J1753.5-0127: DISK-DILUTED FLUCTUATIONS IN THE OUTBURST PEAK

After a careful analysis of the instrumental effects on the Poisson noise to demonstrate the feasibility of detailed stochastic variability studies with the Swift X-Ray Telescope (XRT), we analyze the variability of the black hole X-ray binary SWIFT J1753.5-0127 in all XRT observations during 2005-2010. We present the evolution of the power spectral components along the outburst in two energy bands: soft (0.5-2 keV) and hard (2-10 keV), and in the hard band we find results consistent with those from the Rossi X-Ray Timing Explorer (RXTE). The advantage of the XRT is that we can also explore the soft band not covered by RXTE. The source has previously been suggested to host an accretion disk extending down to close to the black hole in the low hard state, and to show low-frequency variability in the soft-band intrinsic to this disk. Our results are consistent with this, with stronger low-frequency variability at low intensities in the soft than in the hard band. From our analysis, we are able to present the first measurements of the soft-band variability in the peak of the outburst. We find the soft band to be less variable than the hard band, especially at high frequencies, opposite to what is seen at low intensity. Both results can be explained within the framework of a simple two emission-region model where the hot flow is more variable in the peak of the outburst and the disk is more variable at low intensities.

79 ASTRONOMY AND ASTROPHYSICS↗

Temperature dependence of the NO3 absorption spectrum

The absorption spectrum of the gas-phase NO3 radical has been studied between 220 and 700 nm by using both flash photolysis and discharge flow reactors for the production of NO3. In the flash photolysis method, cross sections at the peak of the (0,0) band at 661.9 nm were measured relative to the cross section of ClONO2 at several different wavelengths. From the best current measurements of the ClONO2 spectrum, the NO3 cross section at 661.9 nm was determined to be (2.28 + or 0.34) x 10 to the -17th sq cm/molecule at 298 K. Measurements at 230 K indicated that the cross section increases by a factor of 1.18 at the peak of the (0,0) band. The discharge flow method was used both to obtain absolute cross sections at 661.9 nm and to obtain relative absorption spectra between 300 and 700 nm at 298 and 230 K. A value of (1.83 + or - 0.27) x 10 to the -17th sq cm/molecule was obtained for sigma NO3 at 661.9 nm at 298 K. Upper limits to the NO3 cross sections were also measured between 220 and 260 nm with the discharge flow method.

Sander, Stanley P.↗

Peak Wind Forecasts for the Launch-Critical Wind Towers on Kennedy Space Center/Cape Canaveral Air Force Station, Phase IV

This final report describes the development of a peak wind forecast tool to assist forecasters in determining the probability of violating launch commit criteria (LCC) at Kennedy Space Center (KSC) and Cape Canaveral Air Force Station (CCAFS). The peak winds arc an important forecast clement for both the Space Shuttle and Expendable Launch Vehicle (ELV) programs. The LCC define specific peak wind thresholds for each launch operation that cannot be exceeded in order to ensure the safety of the vehicle. The 45th Weather Squadron (45 WS) has found that peak winds are a challenging parameter to forecast, particularly in the cool season months of October through April. Based on the importance of forecasting peak winds, the 45 WS tasked the Applied Meteorology Unit (AMU) to update the statistics in the current peak-wind forecast tool to assist in forecasting LCC violations. The tool includes onshore and offshore flow climatologies of the 5-minute mean and peak winds and probability distributions of the peak winds as a function of the 5-minute mean wind speeds.

Crawford, Winifred↗

Hydrodynamic and Longitudinal Impedance Analysis of Cerebrospinal Fluid Dynamics at the Craniovertebral Junction in Type I Chiari Malformation

Elevated or reduced velocity of cerebrospinal fluid (CSF) at the craniovertebral junction (CVJ) has been associated with type I Chiari malformation (CMI). Thus, quantification of hydrodynamic parameters that describe the CSF dynamics could help assess disease severity and surgical outcome. In this study, we describe the methodology to quantify CSF hydrodynamic parameters near the CVJ and upper cervical spine utilizing subject-specific computational fluid dynamics (CFD) simulations based on in vivo MRI measurements of flow and geometry. Hydrodynamic parameters were computed for a healthy subject and two CMI patients both pre- and post-decompression surgery to determine the differences between cases. For the first time, we present the methods to quantify longitudinal impedance (LI) to CSF motion, a subject-specific hydrodynamic parameter that may have value to help quantify the CSF flow blockage severity in CMI. In addition, the following hydrodynamic parameters were quantified for each case: maximum velocity in systole and diastole, Reynolds and Womersley number, and peak pressure drop during the CSF cardiac flow cycle. The following geometric parameters were quantified: cross-sectional area and hydraulic diameter of the spinal subarachnoid space (SAS). The mean values of the geometric parameters increased post-surgically for the CMI models, but remained smaller than the healthy volunteer. All hydrodynamic parameters, except pressure drop, decreased post-surgically for the CMI patients, but remained greater than in the healthy case. Peak pressure drop alterations were mixed. To our knowledge this study represents the first subject specific CFD simulation of CMI decompression surgery and quantification of LI in the CSF space. Further study in a larger patient and control group is needed to determine if the presented geometric and/or hydrodynamic parameters are helpful for surgical planning.

59 BASIC BIOLOGICAL SCIENCES↗

Ozone in the Pacific Troposphere from Ozonesonde Observations

Ozone vertical profile measurements obtained from ozonesondes flown at Fiji, Samoa, Tahiti and the Galapagos are used to characterize ozone in the troposphere over the tropical Pacific. There is a significant seasonal variation at each of these sites. At sites in both the eastern and western Pacific, ozone is highest at almost all levels in the troposphere during the September-November season and lowest during, March-May. There is a relative maximum at all of the sites in the mid-troposphere during all seasons of the year (the largest amounts are usually found near the tropopause). This maximum is particularly pronounced during, the September-November season. On average, throughout the troposphere at all seasons, the Galapagos has larger ozone amounts than the western Pacific sites. A trajectory climatology is used to identify the major flow regimes that are associated with the characteristic ozone behavior at various altitudes and seasons. The enhanced ozone seen in the mid-troposphere during September-November is associated with flow from the continents. In the western Pacific this flow is usually from southern Africa (although 10-day trajectories do not always reach the continent), but also may come from Australia and Indonesia. In the Galapagos the ozone peak in the mid-troposphere is seen in flow from the South American continent and particularly from northern Brazil. The time of year and flow characteristics associated with the ozone mixing ratio peaks seen in both the western and eastern Pacific suggest that these enhanced ozone values result from biomass burning. In the upper troposphere low ozone amounts are seen with flow that originates in the convective western Pacific.

Oltmans, S. J.↗

Force and Pressure-Distribution Measurements on a Rectangular Wing with Double-Hinged Nose

The previous measurements on airfoils with hinged nose disclosed a comparatively large low-pressure peak at the bend of the hinged nose; which favored the separation of flow. It was therefore attempted to reduce these low-pressure peaks by reducing the camber of the forward profile and thereby ensure a longer adherence of the flow and a maximum lift increase. The forces were measured on a rectangular wing with double-hinged nose and end plates, the pressure distributions were measured in the center section of the wing. The measurements disclosed that the highest lift attained with a single-hinged nose cannot be increased by a double-hinged nose. The sum of the deflection angles of both hinged noses related to the maximum lift is about equal to the corresponding angle of the single-hinge nose (approx. 30 deg to 40). The respective angle of attack in both cases amounts to approx. 21 deg. Even the low-pressure peak is about the same in both cases (P/q approx. -5.5). Therefore, a milder curvature of the forward portion of the profile affords no definite increase of the maximum lift.

Lemme, H. A.↗

Nacelle design

The external cowlings of engine nacelles on large turbofan powered aircraft are good candidates for application of natural laminar flow. These nacelles usually have shorter characteristic lengths than other candidate surfaces such as wings and fuselages and therefore have lower characteristic Reynolds numbers. A conceptive figure of the natural flow nacelle (NLF) is shown. On the typical nacelle the flow accelerates to a curvature induced velocity peak near the lip and then decelerates over the remainder of the nacelle length. Transition occurs near the start of the deceleration, so turbulent flow with high friction coefficient exists over most of the nacelle length. On the other hand, the NLF nacelle is contoured to have an accelerating flow over most of its length, so transition is delayed, and a relatively lower friction drag exists over most of the nacelle. The motivation for development of the LFN is a potential 40 to 50 percent reduction in nacelle friction drag.

Faust, G. K.↗

Blind Modeling Validation Exercises Using the Horizontal Dry Cask Simulator

The U.S. Department of Energy (DOE) established a need to understand the thermal-hydraulic properties of dry storage systems for commercial spent nuclear fuel (SNF) in response to a shift towards the storage of high-burnup (HBU) fuel (> 45 gigawatt days per metric ton of uranium, or GWd/MTU). This shift raises concerns regarding cladding integrity, which faces increased risk at the higher temperatures within spent fuel assemblies present within HBU fuel compared to low-burnup fuel (≤ 45 GWd/MTU). A dry cask simulator (DCS) was built at Sandia National Laboratories (SNL) in Albuquerque, New Mexico to produce validation-quality data that can be used to test the accuracy of the modeling used to predict cladding temperatures. These temperatures are critical to evaluating cladding integrity throughout the storage cycle of commercial spent nuclear fuel. A model validation exercise was previously carried out for the DCS in a vertical configuration. Lessons learned during the previous validation exercise have been applied to a new, blind study using a horizontal dry cask simulator (HDCS). Three modeling institutions – the Nuclear Regulatory Commission (NRC), Pacific Northwest National Laboratory (PNNL), and Empresa Nacional del Uranio, S.A., S.M.E. (ENUSA) – were granted access to the input parameters from the DCS Handbook, SAND2017-13058R, and results from a limited data set from the horizontal BWR dry cask simulator tests reported in the HDCS update report, SAND2019-11688R. With this information, each institution was tasked to calculate peak cladding temperatures and air mass flow rates for ten HDCS test cases. Axial as well as vertical and horizontal transverse temperature profiles were also calculated. These calculations were done using modeling codes (ANSYS/Fluent, STAR-CCM+, or COBRA-SFS), each with their own unique combination of modeling assumptions and boundary conditions. For this validation study, the ten test cases of the horizontal dry cask simulator were defined by three independent variables – fuel assembly decay heat (0.5 kW, 1 kW, 2.5 W, and 5 kW), internal backfill pressure (100 kPa and 800 kPa), and backfill gas (helium and air). The plots provided in Chapter 3 of this report show the axial, vertical, and horizontal temperature profiles obtained from the dry cask simulator experiments in the horizontal configuration and the corresponding models used to describe the thermal-hydraulic behavior of this system. The tables provided in Chapter 3 illustrate the closeness of fit of the model data to the experiment data through root mean square (RMS) calculations of the error in peak cladding temperatures (PCTs), PCT axial locations, axial temperature profiles, vertical and horizontal temperature profiles at two different axial locations, and air mass flow rates for the ten test cases, normalized by the experimental results. The model results are assigned arbitrary model numbers to retain anonymity. Due to the relatively flat axial temperature profiles, small temperature gradients resulted in large deviations of all models’ PCT axial location from the experimental PCT axial location. When the PCT axial location error is excluded in the calculation of the combined RMS of the normalized errors that considers PCT, the temperature profiles, and the air mass flow rates, the model data fits the experimental data to within 5%. When the vault information is excluded, the model data fits the experimental data to within 2.5%. An error analysis was developed further for one model, using the model and experimental uncertainties in each validation parameter to calculate validation uncertainties. The uncertainties for each parameter were used to define quantifiable validation criteria. For this analysis, the model was considered validated for a given comparison metric if the normalized error in that metric divided by the validation uncertainty was less than or equal to 1. When considering the combined RMS of the normalized errors of all metrics divided by their validation uncertainties, the model was found to have satisfied the criterion for model validation.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗