Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “peak estimation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

National variability in Americans’ COVID-19 protective behaviors: Implications for vaccine roll-out

Protective behaviors such as mask wearing and physical distancing are critical to slow the spread of COVID-19, even in the context of vaccine scale-up. Understanding the variation in self-reported COVID-19 protective behaviors is critical to developing public health messaging. The purpose of the study is to provide nationally representative estimates of five self-reported COVID-19 protective behaviors and correlates of such behaviors. In this cross-sectional survey study of US adults, surveys were administered via internet and telephone. Adults were surveyed from April 30-May 4, 2020, a time of peaking COVID-19 incidence within the US. Participants were recruited from the probability-based AmeriSpeak® national panel. Brief surveys were completed by 994 adults, with 73.0% of respondents reported mask wearing, 82.7% reported physical distancing, 75.1% reported crowd avoidance, 89.8% reported increased hand-washing, and 7.7% reported having prior COVID-19 testing. Multivariate analysis (p critical value .05) indicates that women were more likely to report protective behaviors than men, as were those over age 60. Respondents who self-identified as having low incomes, histories of criminal justice involvement, and Republican Party affiliation, were less likely to report four protective behaviors, though Republicans and individuals with criminal justice histories were more likely to report having received COVID-19 testing. The majority of Americans engaged in COVID-19 protective behaviors, with low-income Americans, those with histories of criminal justice involvement, and self-identified Republicans less likely to engage in these preventive behaviors. Culturally competent public health messaging and interventions might focus on these latter groups to prevent future infections. These findings will remain highly relevant even with vaccines widely available, given the complementarities between vaccines and protective behaviors, as well as the many challenges in delivering vaccines.

60 APPLIED LIFE SCIENCES↗

Simulated Changes in Tropical Cyclone Size, Accumulated Cyclone Energy and Power Dissipation Index in a Warmer Climate

Detection, attribution and projection of changes in tropical cyclone intensity statistics are made difficult from the potentially decreasing overall storm frequency combined with increases in the peak winds of the most intense storms as the climate warms. Multi-decadal simulations of stabilized climate scenarios from a high-resolution tropical cyclone permitting atmospheric general circulation model are used to examine simulated global changes from warmer temperatures, if any, in estimates of tropical cyclone size, accumulated cyclonic energy and power dissipation index. Changes in these metrics are found to be complicated functions of storm categorization and global averages of them are unlikely to easily reveal the impact of climate change on future tropical cyclone intensity statistics.

Wehner, Michael (ORCID:0000000159910082)↗

Harvesting the low-hanging fruit of high energy savings -- Virtual Occupancy using Wi-Fi Data

Approximately 20% of primary energy consumed in the U.S. is attributed to HVAC use. Ideally, HVAC operation would be driven by actual building occupancy, but lack of reliable occupancy information often results in the use of conservative static schedules. This disparity is even more pronounced in a college campus, where the function of each space differs by building (classrooms, offices, libraries) and the class schedules change frequently -- every semester, day of week, and hour. While several research papers propose the use of counts of the Wi-Fi connections (e.g., phones, computers) as a proxy for occupancy, few real-world implementations exist. This paper describes the development and deployment of an open-source Wi-Fi-to-Occupancy software library in 65 buildings of a college campus, and the planned integration with the building energy management and control system at the building scale. Over a year of Wi-Fi data was gathered into distinct academic periods, including fall and spring semester, academic breaks, and summer sessions. Patterns such as students moving between classrooms, closing laptops before exams, etc., can be visualized from the data. Approximating occupancy from Wi-Fi data presents challenges which we address in this project -- for example, identifying static devices, or estimating the ratio of devices per person. Utilizing real-time occupancy data to inform optimal HVAC schedules and ventilation rates creates the potential to identify and reduce energy waste. Other potential applications include forecasting occupancy, and using Wi-Fi data to predict peak demands. Finally, the paper discusses how to easily scale these tools to other buildings.

Pritoni, Marco↗

AGR-5/6/7 CAPSULE 1 THERMAL MODEL WITH OFFSET GAS GAPS

Fuel compact temperatures are a crucial factor in assessing the irradiation performance of tristructural isotropic (TRISO) fuel particles. In the absence of direct measurement, fuel compact temperatures were calculated using a 3 D finite-element thermal model that was subject to simulation uncertainty. The most dominant factor in the uncertainty of calculated fuel temperatures is the gas gap uncertainty caused by the graphite holder nub-to-capsule clearance. This thermal model was revised to examine the most probable graphite offset position for Capsule 1 for four different days during the irradiation. In the analysis, the offset distance and azimuthal direction at both the top and bottom of the holder were varied. The best-fit offset was estimated based on the minimum root mean square error (RMSE) of the residuals (measured minus calculated thermocouple [TC] temperatures) for the operational TCs in Capsule 1. Near the end of the irradiation, when the graphite had shrunk and the gas gaps had grown, a peak temperature was found with maximum offset along the TC lines, with nickel introducing a potential mechanism for fuel particle failures.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Plasma pressure profiles in a sheared-flow-stabilized Z-pinch

We report the plasma pressure reached inside the central plasma column of a sheared-flow-stabilized Z-pinch using Thomson scattering measurements. Building on previously reported experimental results and the analysis methods established for the high temperature and moderate density plasmas generated on the FuZE device, we show evidence of a central plasma region with higher electron temperature and density, which is consistent with a pinch behavior. Elevated electron temperatures up to 2.25 ± 0.8 keV and densities up to (4.9±0.2)×1017 cm−3 are observed to temporally coincide with the fusion neutron production from the plasma. Reconstructed plasma pressure profiles highlight the presence of a several millimeter-wide column with elevated pressure whose location varies shot-to-shot. The plasma pressure rises as neutron production from the deuterium plasma increases, reaching a peak value of 2.6 kBar. This peak value is consistent with a radially force-balanced pinch equilibrium model based on the measured ∼320 kA pinch current. Complete datasets were obtained at two axial locations, 10 and 20 cm axial position from the tip of the central electrode, which corroborate the estimated neutron source axial lengths.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

High-temperature ferromagnetism in Cr 1+x Pt 5-x P

In this work, we present the growth and basic magnetic and transport properties of Cr 1+x Pt 5-x P. We show that single crystals can readily be grown from a high-temperature solution created by adding dilute quantities of Cr to Pt-P based melts. Like other 1-5-1 compounds, Cr 1+x Pt 5-x P adopts a tetragonal P4/mmm, structure composed facesharing CrPts like slabs that are broken up along the c-axis by sheets of P atoms. EDS and X-ray diffraction measurements both suggest Cr 1+x Pt 5-x P has mixed occupancy between Cr and Pt atoms, similar to what is found in the closely related compound CrPtg, giving real compositions of Cr 1.5 Pt 4.5 P (x = 0.5). We report that Cr 1.5 Pt 4.5 P orders ferromagnetically at T c = 464.5 K with a saturated moment of ≈ 2.1 μs/Cr at 1.8 K. Likely owing to the strong spin-orbit coupling associated with the large quantity of high Z, Pt atoms, Cr 1.5 Pt 4.5 P has exceptionally strong planar anisotropy with estimated anisotropy fields of 345 kOe and 220 kOe at 1.8 K and 300 K respectively. The resistance of Cr 1.5 Pt 4.5 P has a metallic temperature dependence with relatively weak magnetoresistance. Electronic band structure calculations show that CrPt 5 P has a large peak in the density of states near the Fermi level which is split into spin majority and minority bands in the ferromagnetic state. Furthermore, the calculations suggest substantial hybridization between Cr-3d and Pt-5d states near the Fermi level, in agreement with the experimentally measured anisotropy.

36 MATERIALS SCIENCE↗

Impact of strong magnetization in cylindrical plasma implosions with applied B-field measured via x-ray emission spectroscopy

Magnetization is a key strategy for enhancing inertial fusion performance, though accurate characterization of magnetized dense plasmas is needed for a better comprehension of the underlying physics. Measured spectra from imploding Ar-doped D 2 -filled cylinders at the OMEGA laser show distinctive features with and without an imposed magnetic field. A multizone spectroscopic diagnosis leads to quantitative estimates of the plasma conditions, namely revealing a 50% core temperature rise at half mass density when a 30-T seed field is applied. Concurrently, experimental spectra align well with predictions from extended-magnetohydrodynamics simulations, providing strong evidence that the attained core conditions at peak compression are consistent with the impact of a 10-kT compressed field. These results pave the way for the validation of magnetized transport models in dense plasmas and for future magnetized laser implosion experiments at a larger scale. Published by the American Physical Society 2024

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Residual mean field model of valence quarks in the nucleon

Abstract We develop a non-perturbative model for valence parton distribution functions (PDFs) based on the mean field interactions of valence quarks in the nucleonic interior. The main motivation for the model is to obtain a mean field description of the valence quarks as a baseline to study the short range quark–quark interactions that generate the high x tail of PDFs. The model is based on the separation of the valence three-quark cluster and residual system in the nucleon. Then the nucleon structure function is calculated within the effective light-front diagrammatic approach introducing nonperturbative light-front valence quark and residual wave functions. Within the model a new relation is obtained between the position, $$x_p$$ x p , of the peak of $$xq_V(x)$$ x q V ( x ) distribution of the valence quark and the effective mass of the residual system, $$m_R$$ m R , in the form: $$x_{p} \approx {1\over 4} (1-{m_R\over m_N})$$ x p ≈ 1 4 ( 1 - m R m N ) at starting $$Q^2$$ Q 2 . This relation explains the difference in the peak positions for d- and u-quarks through the expected difference of residual masses for valence d- and u-quark distributions. The parameters of the model are fixed by fitting the calculated valence quark distributions to the phenomenological PDFs. This allowed us to estimate the overall mean field contribution in baryonic and momentum sum rules for valence d- and u-quarks. Finally, the evaluated parameters of the non-perturbative wave functions of valence 3q-cluster and residual system can be used in calculation of other quantities such as nucleon form factors, generalized partonic and transverse momentum distributions.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Proton capture on 34 S in the astrophysical energy regime of O-Ne novae

Nuclear reaction sensitivity studies have shown that the final isotopic abundance of O-Ne nova nucleosynthesis is dependent on the 34 S(p,γ) 35 Cl reaction at astrophysical energies corresponding to peak nova burning temperatures of 0.1–0.4 GK. Isotopic ratios of the S, Cl, and Ar products are all used in various methods of cosmochemical analysis of presolar meteoritic grains. Due to the lack of direct experimental data, the 34 S+p reaction rate has been estimated using statistical modeling or information from indirect nucleon transfer experiments. In order to provide direct reaction information, here the resonance strengths of several low energy resonances, E c.m. = 272–495 keV, in the 34 S(p,γ) 35 Cl reaction were measured for the first time in inverse kinematics using the DRAGON recoil separator located at TRIUMF, Canada’s Particle Accelerator Centre in Vancouver.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Collaborative Research: Properties and Dynamics of the Shallow Crust (Final Report)

Ground motions recorded at one location are often extrapolated to nearby regions within a given radius. Here, we explore the appropriateness of spatial extrapolation using data from seven small aperture seismic network deployments in southern California. Six of these deployments are linear arrays of 4-13 stations, and one is a 2D array of 13 stations at Pinyon Flats Observatory. The spatial footprint array diameters are 3 km or less, and each array was operational for a year or more. From our base catalog (M2.5+ earthquakes; 4038 events; September 2010 - June 2023), automated methods remove temporally overprinted waveforms from nearby events (< 5 km) in quick succession (< 5 min) and data with nonviable waveforms. These 200 samples per second data are filtered at 0.5-25 Hz and must have signal-tonoise ratios (SNRs) of 2.5+. Peak ground acceleration (PGA) and peak ground velocity (PGV) are derived individually from the maximum absolute values of each of the 3-component waveforms (vertical, northsouth, and east-west). Five of the seven arrays traverse the San Jacinto fault, and two do not. Ground motion observations are compared with theoretical estimates from Abrahamson et al., 2014. On average, arrays deployed within and across fault zones consistently record ground motions above theoretical expectations, whereas off-fault arrays record ground motions at or slightly below theoretical expectations. We attribute these differences to site conditions because these trends prevail for the full data suites. For each network and each individual channel, the coefficient of variation indicates that the standard deviations are ~30±6% of the mean. Exploring relative ground motion contributions from all three channels (ternary plots), as expected, most data show that vertical ground motions are attenuated compared to horizontal ones. However, this is not always the case for RA array data, where vertical motions can be ~2-3 times larger than horizontal motions for select events near Cahuilla, CA. These anomalously high vertical motions are focal mechanism-related. These results suggest that ternary plots created using only a small amount of data can be used as a data quality metric and a tool to find anomalous features in three-component data.

58 GEOSCIENCES↗

Mechanical Loads on Spent Nuclear Fuel in the General 30 cm Package Drop Scenario

The U.S. Department of Energy Office of Nuclear Energy (DOE-NE) Spent Fuel and Waste Science & Technology (SFWST) research program is guided by the high-level goal of closing prioritized knowledge gaps related to spent nuclear fuel (SNF) storage and transportation, which are summarized by Saltzstein et al. (2020). One of the high-priority knowledge gaps is the identification and quantification of mechanical loads that are expected to affect SNF during normal conditions of transportation and storage to inform the range of physical SNF test programs. This report uses modeling and analysis methods to estimate the mechanical loads on spent nuclear fuel (SNF) in the general 30 cm package drop scenario. The drop scenario assumes impact limiters are in place in the transportation configuration and the impact surface is perfectly rigid. The goal of this analysis is to consider the universe of potential mechanical loading conditions that can happen to SNF and present the results in a manner that is useful for materials testing, decision making, and regulatory rule making purposes. This study uses validated finite element models and methods to perform a broad parametric study of key variables that can affect the mechanical loads on SNF during a hypothetical package free drop scenario. Physical drop test data from a cask and fuel assembly drop test campaign is the basis for model validation. Additionally, the results of the parametric study are used to inform a damage model, which uses multiple nonlinear regression to estimate the relationships between input variables and output response. The parametric finite element analyses consider thousands of input variable combinations, while the damage model estimates millions of combinations. The breadth of this study provides confidence that the potential range of mechanical loads that SNF might experience during the general 30 cm package drop scenario are characterized well enough to consider this knowledge gap closed. While this report documents the overall peak values calculated in this study, the 95 th percentile values, the histograms, and the observed trends are equally important. This study covered a large range of SNF temperatures, room temperature to 300°C, and burnups, 10 GWd/MTU to 62 GWd/MTU. Each temperature and burnup combination has a different cladding yield strain, so it is more meaningful to summarize the calculated cladding strain response as its factor of safety, which is defined relative to the yield strain. The factor of safety is calculated as the yield strain divided by the peak cladding strain. A factor of safety greater than unity indicates that the cladding remains below yield, whereas a value less than unity is indicative of plastic deformation. In all cases of this study a safety factor over 1.0 was calculated, although in the most limiting case at 300°C the safety factor was only 1.01, which suggests that yielding could occur when additional loads like rod internal pressure are included. When the temperature is restricted to 200°C the limiting safety factor increases to 1.28, which has significant margin to accommodate internal pressure and potential local cladding defects that could cause a local stress concentration. An important trend in the calculated fuel rod mechanical loads is that the 2 nd highest loaded fuel rod in an assembly tends to be significantly lower than the highest loaded rod. The implication is that even if one rod in an assembly experiences a failure the loads would have to be significantly higher to cause two or more rods to fail.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

AGR-5/6/7 Thermal Model with Non-uniform Gas Gaps

Fuel compact temperatures are a crucial factor in assessing the irradiation performance of tri-structural isotropic fuel particles. In the absence of direct measurement, fuel compact temperatures were calculated using a three-dimensional finite element thermal model, which is subject to simulation uncertainty. The most dominant factor in the uncertainty of calculated fuel temperatures is the gas gap uncertainty due to the nub-to-shell clearance caused by a design error of AGR-5/6/7 capsules. The thermal model was revised to examine the most probable graphite offset position for six different days during the irradiation for Capsules 1 and 2. The analysis varied the offset distance and azimuthal direction at both the top and bottom of the holder. The best-fit offset was estimated based on the minimum root mean square error of the residuals (measured minus calculated) for the operational thermocouples (TCs). From these results, the following conclusions were made: (1) The holder offsets led to slightly lower average temperatures but wider temperature variations (lower minimum and higher peak fuel temperatures) for both Capsule 1 and Capsule 2. (2) During earlier cycles (162A–164B), when numerous TCs were still operational, the best-fit offset distance varied over a specific range for both the top and bottom ([0.002–0.0035 in.] for Capsule 1 and [0.003-0.004 in] for Capsule 2). In contrast, the offset azimuthal direction varied widely, especially for the offset at the bottom of the Capsule 1 holder. This is because holder movement was somewhat constrained at the top of Capsule 1 by the TC leads running through the capsule head and into the holder and by the through tubes in Capsule 2, but the Capsule 1 bottom did not have this type of constraint. (3) During later cycles, when all TCs failed, applying the maximum possible offset of 0.006 in. to the northwest direction for both the top and bottom resulted in a calculated peak fuel temperature of 1557? in Capsule 1 (i.e., a 135? increase from 1422? with zero offset on September 20, 2019 (166A)); the maximum offset of 0.0068 in. to the south for both top and bottom resulted in a calculated peak fuel temperature of 1110°C in Capsule 2 on April 20, 2020 (i.e., a 116? increase from 994? with zero offset (168A)). High peak fuel temperatures in Capsule 1 during Cycle 166A could be the cause of massive particle failure near the end of this cycle. (4) Even though the highest temperature at the tip of Type-N TCs, such as TC-1-7, slightly exceeded 1000?, the temperature along the TC wire reached as high as 1335? assuming an offset of 0.006 in. in the northwest of Capsule 1 holder near the end of Cycle 166A. This temperature significantly exceeds the temperature threshold at which TC degradation is expected to occur, ultimately contributing to considerable particle failures in Capsule 1. For eight Type-N TCs in Capsule 2, the peak TC line temperature was much lower (i.e., 1029°C for TC-2-5), assuming maximum offset of 00068 in. to the south during cycle 168A.

advanced gas reactors↗

AGR-5/6/7 Thermal Model with Non-uniform Gas Gaps

Fuel compact temperatures are a crucial factor in assessing the irradiation performance of tri-structural isotropic fuel particles. In the absence of direct measurement, fuel compact temperatures were calculated using a three-dimensional finite element thermal model, which is subject to simulation uncertainty. The most dominant factor in the uncertainty of calculated fuel temperatures is the gas gap uncertainty due to the nub-to-shell clearance caused by a design error of AGR-5/6/7 capsules. The thermal model was revised to examine the most probable graphite offset position for six different days during the irradiation for Capsules 1 and 2. The analysis varied the offset distance and azimuthal direction at both the top and bottom of the holder. The best-fit offset was estimated based on the minimum root mean square error of the residuals (measured minus calculated) for the operational thermocouples (TCs). From these results, the following conclusions were made: (1) The holder offsets led to slightly lower average temperatures but wider temperature variations (lower minimum and higher peak fuel temperatures) for both Capsule 1 and Capsule 2. (2) During earlier cycles (162A–164B), when numerous TCs were still operational, the best-fit offset distance varied over a specific range for both the top and bottom ([0.002–0.0035 in.] for Capsule 1 and [0.003-0.004 in] for Capsule 2). In contrast, the offset azimuthal direction varied widely, especially for the offset at the bottom of the Capsule 1 holder. This is because holder movement was somewhat constrained at the top of Capsule 1 by the TC leads running through the capsule head and into the holder and by the through tubes in Capsule 2, but the Capsule 1 bottom did not have this type of constraint. (3) During later cycles, when all TCs failed, applying the maximum possible offset of 0.006 in. to the northwest direction for both the top and bottom resulted in a calculated peak fuel temperature of 1557? in Capsule 1 (i.e., a 135? increase from 1422? with zero offset on September 20, 2019 (166A)); the maximum offset of 0.0068 in. to the south for both top and bottom resulted in a calculated peak fuel temperature of 1110°C in Capsule 2 on April 20, 2020 (i.e., a 116? increase from 994? with zero offset (168A)). High peak fuel temperatures in Capsule 1 during Cycle 166A could be the cause of massive particle failure near the end of this cycle. (4) Even though the highest temperature at the tip of Type-N TCs, such as TC-1-7, slightly exceeded 1000?, the temperature along the TC wire reached as high as 1335? assuming an offset of 0.006 in. in the northwest of Capsule 1 holder near the end of Cycle 166A. This temperature significantly exceeds the temperature threshold at which TC degradation is expected to occur, ultimately contributing to considerable particle failures in Capsule 1. For eight Type-N TCs in Capsule 2, the peak TC line temperature was much lower (i.e., 1029°C for TC-2-5), assuming maximum offset of 00068 in. to the south during cycle 168A.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Iodine Co-Precipitation with Calcium Carbonate in the Presence of Silica Ions - 20360

Historical releases of I-129 to the subsurface at the U.S. Department of Energy Hanford Site have resulted in large dilute plumes that cover an area of over 50 km{sup 2}. The most concentrated I-129 plume is associated with the 200 West Area in the 200-UP-1 operable unit of the Hanford Central Plateau, where peak concentrations have been measured up to 30 times the drinking water standard of 1 pCi/L. The mobility of iodine depends on many factors, including chemical speciation, pH, redox conditions, as well as the presence of organic matter, calcium carbonate minerals and microbial activities. Speciation measurements estimate that the majority of the iodine (∼76%) in Hanford groundwater exists as iodate. Information on processes that affect iodate mobility in the Hanford subsurface support evaluation of environmental management options for the I-129 plumes. Iodate can be incorporated into calcium carbonate, which is a potential mechanism of naturally attenuating radioiodine in groundwater. However, the silica content in porewater may impact the contaminant-calcium carbonate incorporation process. Silica is one of the most abundant elements in nature and can have an impact on chemical weathering of alkaline-earth carbonates in the environment. Hence, this research aims to advances knowledge of the iodine co-precipitation process with calcium carbonate in the presence of silica. This information supports the technical basis evaluation of natural attenuation for I-129. Samples for these studies were prepared using calcium carbonate-forming solutions that included certified grade sodium meta-silicate nonahydrate (Na{sub 2}SiO{sub 3}), calcium chloride dehydrate (CaCl{sub 2}.2H{sub 2}O), sodium carbonate (NaCO{sub 2}), and sodium hydroxide (NaOH) solutions for pH adjustments. Triplicate samples were prepared with silica concentrations in the solution of 0 mM, 0.5 mM and 20 mM, mixed with an iodate standard (1000 ppm of IO{sub 3}{sup -} in H{sub 2}O) and sampled over a one-week period. Preliminary data analyses suggest that less iodine remains in solution in the presence of silica (average remaining aqueous fraction 0.23±0.03 at 20 mM of Si) relative to samples without silica (0.52±0.06); an indication that more iodine has been sorbed or incorporated into precipitates. However, the mechanisms for this behavior are still under investigation and need to be interpreted relative to pore water compositions that are representative of Hanford site-specific conditions. Scanning electron microscope equipped with energy dispersive spectroscopy (SEM-EDS) analyses were performed to observe the solid phase morphology in these experiments and showed rhombohedral calcite crystals covered with amorphous Si floccules. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

AGR-5/6/7 Thermal Model with Non-uniform Gas Gaps

Fuel compact temperatures are a crucial factor in assessing the irradiation performance of tri-structural isotropic fuel particles. In the absence of direct measurement, fuel compact temperatures were calculated using a three-dimensional finite element thermal model, which is subject to simulation uncertainty. The most dominant factor in the uncertainty of calculated fuel temperatures is the gas gap uncertainty due to the nub-to-shell clearance caused by a design error of AGR-5/6/7 capsules. The thermal model was revised to examine the most probable graphite offset position for six different days during the irradiation for Capsules 1 and 2. The analysis varied the offset distance and azimuthal direction at both the top and bottom of the holder. The best-fit offset was estimated based on the minimum root mean square error of the residuals (measured minus calculated) for the operational thermocouples (TCs). From these results, the following conclusions were made: (1) The holder offsets led to slightly lower average temperatures but wider temperature variations (lower minimum and higher peak fuel temperatures) for both Capsule 1 and Capsule 2. (2) During earlier cycles (162A–164B), when numerous TCs were still operational, the best-fit offset distance varied over a specific range for both the top and bottom ([0.002–0.0035 in.] for Capsule 1 and [0.003-0.004 in] for Capsule 2). In contrast, the offset azimuthal direction varied widely, especially for the offset at the bottom of the Capsule 1 holder. This is because holder movement was somewhat constrained at the top of Capsule 1 by the TC leads running through the capsule head and into the holder and by the through tubes in Capsule 2, but the Capsule 1 bottom did not have this type of constraint. (3) During later cycles, when all TCs failed, applying the maximum possible offset of 0.006 in. to the northwest direction for both the top and bottom resulted in a calculated peak fuel temperature of 1557? in Capsule 1 (i.e., a 135? increase from 1422? with zero offset on September 20, 2019 (166A)); the maximum offset of 0.0068 in. to the south for both top and bottom resulted in a calculated peak fuel temperature of 1110°C in Capsule 2 on April 20, 2020 (i.e., a 116? increase from 994? with zero offset (168A)). High peak fuel temperatures in Capsule 1 during Cycle 166A could be the cause of massive particle failure near the end of this cycle. (4) Even though the highest temperature at the tip of Type-N TCs, such as TC-1-7, slightly exceeded 1000?, the temperature along the TC wire reached as high as 1335? assuming an offset of 0.006 in. in the northwest of Capsule 1 holder near the end of Cycle 166A. This temperature significantly exceeds the temperature threshold at which TC degradation is expected to occur, ultimately contributing to considerable particle failures in Capsule 1. For eight Type-N TCs in Capsule 2, the peak TC line temperature was much lower (i.e., 1029°C for TC-2-5), assuming maximum offset of 00068 in. to the south during cycle 168A.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Stream Temperature Responses to Summer Urban Rain Events Along the Savannah River

The hydrological urban heat island (HUHI) is a recent facet of the urban heat island (UHI), describing thermal enhancement of bodies of water in response to urbanization. Although the forefront of this work has been studied for large Metropolitan areas, this effect on developing cities is currently unknown. To locally measure and quantify HUHI effects in a developing city, we utilized Multi-Radar Multi Sensor (MRMS) radar-derived rainfall data to estimate rainfall in the Augusta Metropolitan Area (AMA) and the Savannah Metropolitan Area (SMA), two developing communities adjacent to the Savannah River. We analyzed mean temperature trends of two stream gauges measuring temperature at, and downstream of the central AMA and the SMA. Results show overall peak stream temperatures within AMA are reached within a 2hr timeframe with surge temperatures between 1-2 K, perhaps assisted by the presence of the Augusta Shoals further upstream. The SMA appears to have little HUHI effects due to urban greening and impacts to coastal meteorology. It is suggested that Moderate rainfall events (10-25mm of rainfall) have a significant correlation (~0.1 correlation coefficient with a significance level of 0.05) between stream temperature and rainfall, indicating potential warmer runoff input into the Savannah River. Although results seem promising, further research into moderate rainfall events are needed to determine the extent of the HUHI for AMA.

Wermter, Joseph E. [Savannah River National Labora↗

Informing solar blind radioluminescence imaging through a calibrated spectrum

While direct radiation detection methods offer great insight into the origin of ionizing particles and photons, their use to locate contaminated areas or concealed radioactive sources can lead to undue exposure of personnel and equipment to ionizing radiation or the potential for contamination. These same sources induce ultraviolet (UV) optical photon fluorescence in air – a process referred to as radioluminescence – that may be imaged from low dose regions over larger attenuation lengths than ionizing radiation. However, most optical detection methods are limited to low lighting conditions to image the more abundant ultraviolet-A (UV-A) photons. To extend this capability to room light or daytime conditions, the solar blind region (Ultraviolet-C (UV-C), <280 nm) can be tapped. Though the emission yield of UV-C photons is roughly two orders of magnitude lower than that in the UV-A regime, the UV-C offers dramatic improvements in signal-to-noise ratios under bright lighting conditions due to decreased background interferences. The yield of specific UV-C lines, if present in the literature at all, varies widely, which has a large impact in modeling and analyzing standoff UV-C measurement scenarios. Thus, we have captured improved radioluminescence spectra over 250–400 nm and identified observed emission peaks in ambient air. Many of the UV-C photons produced by ionizing radiation excitation result from high-energy, molecular nitrogen Gaydon-Herman transitions which have had limited study to date for this application. Relating these findings to published UV-A yields, we estimate emissions between 0.15–0.19 photons/MeV over 250–280 nm. Additionally, we also use a commercial corona-discharge imaging camera to demonstrate outdoor UV-C radiation mapping of alpha and gamma emitters from 50 and 75 m standoffs, respectively. The imaged “counts” are compared to optically modelled values and show the same trend over distance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Cosmology From CMB Lensing and Delensed EE Power Spectra Using 2019-2020 SPT-3G Polarization Data

From CMB polarization data alone we reconstruct the CMB lensing power spectrum, comparable in overall constraining power to previous temperature-based reconstructions, and an unlensed E -mode power spectrum, with clear detections of the third through tenth acoustic peaks. The observations, taken in 2019 and 2020 with the South Pole Telescope (SPT) and the SPT-3G camera, cover 1500 deg 2 at 95, 150, and 220 GHz with arcminute resolution and roughly 4.9 µ K-arcmin coadded noise in polarization. The power spectrum estimates, together with systematic parameter estimates and a joint covariance matrix, follow from a Bayesian analysis using the Marginal Unbiased Score Expansion (MUSE) method. The E -mode spectrum at ℓ > 2000 and lensing spectrum at L > 350 are the most precise to date. Assuming the ΛCDM model, and using only these SPT data and priors on τ and absolute calibration from Planck, we find H 0 = 66.81 ± 0.81 km/s/Mpc, comparable in precision to the Planck determination and in 5.4 σ tension with the most precise H 0 inference derived via the distance ladder. We also find S 8 ≡ σ 8 (Ω m /0.3) 0.5 = 0.850 ± 0.017, providing further independent evidence of a slight tension with low-redshift structure probes. The ΛCDM model provides a good simultaneous fit to the combined Planck, ACT, and SPT data, and thus passes a powerful test. Combining these CMB datasets with BAO observations, we explore extensions to the ΛCDM model. We find that the effective number of neutrino species, spatial curvature, and primordial helium fraction are consistent with standard model values, and that the 95% confidence upper limit on the neutrino mass sum is 0.075 eV, close to the minimum sum expected from observations of solar and atmospheric neutrino oscillations. The SPT data are consistent with the somewhat weak (< 3 σ ) preference for excess lensing power seen in Planck and ACT data relative to predictions of the ΛCDM model given the combined Planck, ACT, and BAO data sets. Finally, we also detect at greater than 3 σ the influence of non-linear evolution in the CMB lensing power spectrum and discuss it in the context of the S 8 tension. Forthcoming SPT-3G analyses will feature deeper and wider observations in temperature and polarization, providing even tighter constraints and more powerful tests of the ΛCDM model.

79 ASTRONOMY AND ASTROPHYSICS↗