Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “patch”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Two self-similar Reynolds-stress transport models with anisotropic eddy viscosity

Two Reynolds-averaged Navier-Stokes models with full Reynolds-stress transport (RST) and tensor eddy viscosity are presented. These new models represent RST extensions of the $k−2L−a−\mathscr{C}$ and $k−ϕ−L−a−\mathscr{C}$ models by Morgan. Self-similarity analysis is used to derive constraints on model coefficients required to reproduce expected growth parameters for a variety of canonical flows, including Rayleigh-Taylor (RT) and Kelvin-Helmholtz (KH) mixing layers. Both models are then applied in one-dimensional simulation of RT and KH mixing layers, and the expected self-similar growth rates and anisotropy are obtained. Next, models are applied in two-dimensional simulation of the so-called “tilted rocket rig” inclined RT experiment and in simulation of a shock-accelerated localized patch of turbulence. Here it is found that RST is required to capture the qualitative growth of the shock-accelerated patch, and an anisotropic eddy viscosity provides substantial improvement over a Boussinesq treatment for the tilted rocket rig problem.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Population Mixing in Asymmetric Magnetic Reconnection with a Guide Field

We investigate how population mixing leads to structured electron distribution functions in asymmetric guide-field magnetic reconnection based on particle-in-cell simulations. The change of magnetic connectivity patches populations from different inflow regions to form multicomponent distributions in the exhaust, illustrating the direct consequence of the breaking and rejoining of magnetic flux tubes. Finite Larmor radius (FLR) effects of electrons accelerated by the perpendicular electric fields result in crescent-type nongyrotropic distributions. A new type of nongyrotropy is found to be caused by the combined effects of the FLR and velocity dispersion of electrons accelerated by the parallel electric field. The patching together of populations and the effects of acceleration and the FLR form the first steps of mixing in the exhaust and separatrix regions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Structural analysis of the endogenous glycoallergen Hev b 2 (endo-β-1,3-glucanase) from Hevea brasiliensis and its recognition by human basophils

This study describes the three-dimensional structure of the endogenous glycosylated allergen Hev b 2 (endo-β-1,3-glucanase), which exhibits three post-translational modifications that form a patch on the surface of the molecule that is proposed to be an allergenic IgE epitope. Endogenous glycosylated Hev b 2 (endo-β-1,3-glucanase) from Hevea brasiliensis is an important latex allergen that is recognized by IgE antibodies from patients who suffer from latex allergy. The carbohydrate moieties of Hev b 2 constitute a potentially important IgE-binding epitope that could be responsible for its cross-reactivity. Here, the structure of the endogenous isoform II of Hev b 2 that exhibits three post-translational modifications, including an N-terminal pyroglutamate and two glycosylation sites at Asn27 and at Asn314, is reported from two crystal polymorphs. These modifications form a patch on the surface of the molecule that is proposed to be one of the binding sites for IgE. A structure is also proposed for the most important N-glycan present in this protein as determined by digestion with specific enzymes. To analyze the role of the carbohydrate moieties in IgE antibody binding and in human basophil activation, the glycoallergen was enzymatically deglycosylated and evaluated. Time-lapse automated video microscopy of basophils stimulated with glycosylated Hev b 2 revealed basophil activation and degranulation. Immunological studies suggested that carbohydrates on Hev b 2 represent an allergenic IgE epitope. In addition, a dimer was found in each asymmetric unit that may reflect a regulatory mechanism of this plant defence protein.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Convolutional Neural Network Approach for Mapping Arctic Vegetation Using Multi-Sensor Remote Sensing Fusion

Accurate and high-resolution maps of vegetation are critical for projects seeking to understand the terrestrial ecosystem processes and land-atmosphere interactions in Arctic ecosystems, such as U.S. Department of Energy's Next Generation Ecosystem Experiment (NGEE) Arctic. However, most existing Arctic vegetation maps are at a coarse resolution and with a varying degree of detail and accuracy. Remote sensing-based approaches for mapping vegetation, while promising, are challenging in high latitude environments due to frequent cloud cover, polar darkness, and limited availability of high-resolution remote sensing datasets (e.g., ~ 5 m). This study proposes a new remote sensing based multi-sensor data fusion approach for developing high-resolution maps of vegetation in the Seward Peninsula, Alaska. We focus detailed analysis and validation study around the Kougarok river, located in the central Seward Peninsula of Alaska. We seek to evaluate the integration of hyper-spectral, multi-spectral, radar, and terrain datasets using unsupervised and supervised classification techniques over a ~343.72 km 2 area for generating vegetation classifications at a variety of resolutions (5 m and 12.5 m). We fist applied a quantitative goodness-of-fit method, called Mapcurves, that shows the degree of spatial concordance between the public coarse resolution maps and k-means clustering values and relabels the k values based on the best overlap. We develop a convolutional neural network (CNN) approach for developing high resolution vegetation maps for our study region in Arctic. We compare two CNN approaches: (1) breaking up the images into small patches (e.g., 6 × 6) and predict the vegetation class for entire patch and (2) semantic segmentation and predict the vegetation class for every pixel. We also perform accuracy assessments of the developed data products and evaluate varying CNN architectures. The fusion of hyperspectral and optical datasets performed the best, with accuracy values increased from 0.64 to 0.96-0.97 when using a training map produced by unsupervised clustering and Mapcurves labeling for both CNN models.

Langford, Zach↗

Resident Block-Structured Adaptive Mesh Refinement on Thousands of Graphics Processing Units, In: 2015 44th International Conference on Parallel Processing

Block-structured adaptive mesh refinement (AMR) is a technique that can be used when solving partial differential equations to reduce the number of cells necessary to achieve the required accuracy in areas of interest. These areas (shock fronts, material interfaces, etc.) are recursively covered with finer mesh patches that are grouped into a hierarchy of refinement levels. Despite the potential for large savings in computational requirements and memory usage without a corresponding reduction in accuracy, AMR adds overhead in managing the mesh hierarchy, adding complex communication and data movement requirements to a simulation. In this paper, we describe the design and implementation of a resident GPU-based AMR library, including: the classes used to manage data on a mesh patch, the routines used for transferring data between GPUs on different nodes, and the data-parallel operators developed to coarsen and refine mesh data. We validate the performance and accuracy of our implementation using three test problems and two architectures: an 8 node cluster, and 4,196 nodes of Oak Ridge National Laboratory's Titan supercomputer. Our GPU-based AMR hydrodynamics code performs up to 4.87× faster than the CPU-based implementation, and is scalable on 4,196 K20x GPUs using a combination of MPI and CUDA.

Computer Science↗

Antenna With Embedded Die in Glass Interposer for 6G Wireless Applications

This article presents the antenna-integrated glass interposer for D-band 6G wireless applications using dieembedding technology. Here, we implement the die-embedded package on glass substrates and characterize the electrical performance in the D-band. The electrical characterization employs embedded test dies with the 50-Ω ground–signal–ground (GSG) ports and coplanar waveguides. We achieve low-loss die-to-package transitions by using staggered dielectric vias, which are compared with the transitions of wire-bonding and flip-chip assembly. This article provides detailed information on the design, modeling, fabrication, and characterization of the die-to-package interconnects. This article also demonstrates the integration of microstrip patch antenna array and embedded dies in the D-band. The results show superior electrical performance provided by the die-embedded glass interposer. The die-to-package interconnect exhibits good matching (less than —10-dB S11) and low loss (0.2-dB loss) in the D-band. The integrated 1 × 8 patch antenna array shows 11.6-dB broadside gain and good matching with the embedded die. In addition, by using a temporary carrier, the antenna-integrated glass interposer also has great potential for further heterogeneous integration and thermal management.

42 ENGINEERING↗

DECT-MULTRA: Dual-Energy CT Image Decomposition With Learned Mixed Material Models and Efficient Clustering

Dual-energy computed tomography (DECT) imaging plays an important role in advanced imaging applications due to its material decomposition capability. Image-domain decomposition operates directly on CT images using linear matrix inversion, but the decomposed material images can be severely degraded by noise and artifacts. This paper proposes a new method dubbed DECT-MULTRA for image-domain DECT material decomposition that combines conventional penalized weighted-least squares (PWLS) estimation with regularization based on a mixed union of learned transforms (MULTRA) model. Our proposed approach pre-learns a union of common-material sparsifying transforms from patches extracted from all the basis materials, and a union of cross-material sparsifying transforms from multi-material patches. The common-material transforms capture the common properties among different material images, while the cross-material transforms capture the cross-dependencies. The proposed PWLS formulation is optimized efficiently by alternating between an image update step and a sparse coding and clustering step, with both of these steps having closed-form solutions. The effectiveness of our method is validated with both XCAT phantom and clinical head data. The results demonstrate that our proposed method provides superior material image quality and decomposition accuracy compared to other competing methods.

47 OTHER INSTRUMENTATION↗

Reduced ecosystem resilience quantifies fine-scale heterogeneity in tropical forest mortality responses to drought

Sensitivity of forest mortality to drought in carbon-dense tropical forests remains fraught with uncertainty, while extreme droughts are predicted to be more frequent and intense. Here, in this study, the potential of temporal autocorrelation of high-frequency variability in Landsat Enhanced Vegetation Index (EVI), an indicator of ecosystem resilience, to predict spatial and temporal variations of forest biomass mortality is evaluated against in situ census observations for 64 site-year combinations in Costa Rican tropical dry forests during the 2015 ENSO drought. Temporal autocorrelation, within the optimal moving window of 24 months, demonstrated robust predictive power for in situ mortality (leave-one- out cross-validation R 2 = 0.54), which allows for estimates of annual biomass mortality patterns at 30 m resolution. Subsequent spatial analysis showed substantial fine-scale heterogeneity of forest mortality patterns, largely driven by drought intensity and ecosystem properties related to plant water use such as forest deciduousness and topography. Highly deciduous forest patches demonstrated much lower mortality sensitivity to drought stress than less deciduous forest patches after elevation was controlled. Our results highlight the potential of high-resolution remote sensing to “fingerprint” forest mortality and the significant role of ecosystem heterogeneity in forest biomass resistance to drought.

59 BASIC BIOLOGICAL SCIENCES↗

Optimizing Piezoelectric Material Location and Size for Multiple-Mode Vibration Reduction of Turbomachinery Blades

Modern turbomachinery blades have extremely low inherent damping, which can lead to high transient vibrations and failure through high-cycle fatigue. Smart materials enable vibration reduction while meeting strict blade requirements such as weight and aerodynamic efficiency. In particular, piezoelectric-based vibration reduction offers the potential to reduce vibration semi-actively while simultaneously harvesting sufficient energy to power the implementation. The placement and the size of the piezoelectric material is critical to the vibration reduction capabilities of the system. Furthermore, the implementation should target multiple vibration modes. In this study, we develop a procedure to optimize electromechanical coupling across multiple vibration modes for a representative turbomachinery blade with surface-mounted piezoelectric patches. Experimental validation demonstrates good coupling across three targeted modes with a single piezoelectric patch. Placing the piezoelectric material in regions of high signed strain energy for all targeted modes enables vibration reduction across all of the targeted modes.

36 MATERIALS SCIENCE↗

A comparison of histopathology imaging comprehension algorithms based on multiple instance learning

Whole slide imaging (WSI), also called digital virtual microscopy, is a new imaging modality. It allows for the application of AI and machine learning methods to cancer pathology to help establish a means for the automatic diagnosis of cancer cases. However, designing machine-learning models for WSI is computationally challenging due to its required ultra-high resolution. The current state-of-the-art models use multiple instance learning (MIL). MIL is a weakly-supervised learning method in which the model uses an array of inferences from many smaller instances to make a final classification about the entire set. In the context of WSI, researchers divide the ultra-high-resolution image into many patches. The model then classifies the slide based on an array of inferences from the patches. Among several ways of making the final classification, attention-based mechanisms have resulted in superb accuracy scores. The Transformer, one attention-based algorithm, has reported substantial improvements for WSI comprehension tasks. In this project, we studied and compared several WSI comprehension algorithms. We used the following three datasets: CAMELYON16+17, TCGALung, and TCGA-Kidney. We found that attention-based MIL algorithms performed better than standard MIL algorithms for classifying WSI images, achieving a higher mean accuracy and AUC. However, none of the attention-based algorithms performed significantly better than the others, reporting accuracy scores that varied widely. Presumably, it is due to the limited availability of training samples in the data corpus. Since it is not easy to increase the samples from human subjects, some machine learning techniques like transfer learning could help mitigate this issue.

Saunders, Adam↗

Monte Carlo based beam model using a photon MLC for modulated electron radiotherapy

Purpose: Modulated electron radiotherapy (MERT) promises sparing of organs at risk for certain tumor sites. Any implementation of MERT treatment planning requires an accurate beam model. The aim of this work is the development of a beam model which reconstructs electron fields shaped using the Millennium photon multileaf collimator (MLC) (Varian Medical Systems, Inc., Palo Alto, CA) for a Varian linear accelerator (linac). Methods: This beam model is divided into an analytical part (two photon and two electron sources) and a Monte Carlo (MC) transport through the MLC. For dose calculation purposes the beam model has been coupled with a macro MC dose calculation algorithm. The commissioning process requires a set of measurements and precalculated MC input. The beam model has been commissioned at a source to surface distance of 70 cm for a Clinac 23EX (Varian Medical Systems, Inc., Palo Alto, CA) and a TrueBeam linac (Varian Medical Systems, Inc., Palo Alto, CA). For validation purposes, measured and calculated depth dose curves and dose profiles are compared for four different MLC shaped electron fields and all available energies. Furthermore, a measured two-dimensional dose distribution for patched segments consisting of three 18 MeV segments, three 12 MeV segments, and a 9 MeV segment is compared with corresponding dose calculations. Finally, measured and calculated two-dimensional dose distributions are compared for a circular segment encompassed with a C-shaped segment. Results: For 15 × 34, 5 × 5, and 2 × 2 cm{sup 2} fields differences between water phantom measurements and calculations using the beam model coupled with the macro MC dose calculation algorithm are generally within 2% of the maximal dose value or 2 mm distance to agreement (DTA) for all electron beam energies. For a more complex MLC pattern, differences between measurements and calculations are generally within 3% of the maximal dose value or 3 mm DTA for all electron beam energies. For the two-dimensional dose comparisons, the differences between calculations and measurements are generally within 2% of the maximal dose value or 2 mm DTA. Conclusions : The results of the dose comparisons suggest that the developed beam model is suitable to accurately reconstruct photon MLC shaped electron beams for a Clinac 23EX and a TrueBeam linac. Hence, in future work the beam model will be utilized to investigate the possibilities of MERT using the photon MLC to shape electron beams.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-J-245: Sensitivity of FDG PET Feature Analysis in Multi-Plane Vs. Single-Plane Extraction

Purpose: Sensitivity of PET-derived texture features to reconstruction methods has been reported for features extracted from axial planes; however, studies often utilize three dimensional techniques. This work aims to quantify the impact of multi-plane (3D) vs. single-plane (2D) feature extraction on radiomics-based analysis, including sensitivity to reconstruction parameters and potential loss of spatial information. Methods: Twenty-three patients with solid tumors underwent [{sup 18}F]FDG PET/CT scans under identical protocols. PET data were reconstructed using five sets of reconstruction parameters. Tumors were segmented using an automatic, in-house algorithm robust to reconstruction variations. 50 texture features were extracted using two Methods: 2D patches along axial planes and 3D patches. For each method, sensitivity of features to reconstruction parameters was calculated as percent difference relative to the average value across reconstructions. Correlations between feature values were compared when using 2D and 3D extraction. Results: 21/50 features showed significantly different sensitivity to reconstruction parameters when extracted in 2D vs 3D (wilcoxon α<0.05), assessed by overall range of variation, Rangevar(%). Eleven showed greater sensitivity to reconstruction in 2D extraction, primarily first-order and co-occurrence features (average Rangevar increase 83%). The remaining ten showed higher variation in 3D extraction (average Range{sub var}increase 27%), mainly co-occurence and greylevel run-length features. Correlation of feature value extracted in 2D and feature value extracted in 3D was poor (R<0.5) in 12/50 features, including eight co-occurrence features. Feature-to-feature correlations in 2D were marginally higher than 3D, ∣R∣>0.8 in 16% and 13% of all feature combinations, respectively. Larger sensitivity to reconstruction parameters were seen for inter-feature correlation in 2D(σ=6%) than 3D (σ<1%) extraction. Conclusion: Sensitivity and correlation of various texture features were shown to significantly differ between 2D and 3D extraction. Additionally, inter-feature correlations were more sensitive to reconstruction variation using single-plane extraction. This work highlights a need for standardized feature extraction/selection techniques in radiomics.

60 APPLIED LIFE SCIENCES↗

A continuous surface reconstruction method on point cloud captured from a 3D surface photogrammetry system

Purpose: To accurately and efficiently reconstruct a continuous surface from noisy point clouds captured by a surface photogrammetry system (VisionRT). Methods: The authors have developed a level-set based surface reconstruction method on point clouds captured by a surface photogrammetry system (VisionRT). The proposed method reconstructs an implicit and continuous representation of the underlying patient surface by optimizing a regularized fitting energy, offering extra robustness to noise and missing measurements. By contrast to explicit/discrete meshing-type schemes, their continuous representation is particularly advantageous for subsequent surface registration and motion tracking by eliminating the need for maintaining explicit point correspondences as in discrete models. The authors solve the proposed method with an efficient narrowband evolving scheme. The authors evaluated the proposed method on both phantom and human subject data with two sets of complementary experiments. In the first set of experiment, the authors generated a series of surfaces each with different black patches placed on one chest phantom. The resulting VisionRT measurements from the patched area had different degree of noise and missing levels, since VisionRT has difficulties in detecting dark surfaces. The authors applied the proposed method to point clouds acquired under these different configurations, and quantitatively evaluated reconstructed surfaces by comparing against a high-quality reference surface with respect to root mean squared error (RMSE). In the second set of experiment, the authors applied their method to 100 clinical point clouds acquired from one human subject. In the absence of ground-truth, the authors qualitatively validated reconstructed surfaces by comparing the local geometry, specifically mean curvature distributions, against that of the surface extracted from a high-quality CT obtained from the same patient. Results: On phantom point clouds, their method achieved submillimeter reconstruction RMSE under different configurations, demonstrating quantitatively the faith of the proposed method in preserving local structural properties of the underlying surface in the presence of noise and missing measurements, and its robustness toward variations of such characteristics. On point clouds from the human subject, the proposed method successfully reconstructed all patient surfaces, filling regions where raw point coordinate readings were missing. Within two comparable regions of interest in the chest area, similar mean curvature distributions were acquired from both their reconstructed surface and CT surface, with mean and standard deviation of (μ{sub recon} = − 2.7 × 10{sup −3} mm{sup −1}, σ{sub recon} = 7.0 × 10{sup −3} mm{sup −1}) and (μ{sub CT} = − 2.5 × 10{sup −3} mm{sup −1}, σ{sub CT} = 5.3 × 10{sup −3} mm{sup −1}), respectively. The agreement of local geometry properties between the reconstructed surfaces and the CT surface demonstrated the ability of the proposed method in faithfully representing the underlying patient surface. Conclusions: The authors have integrated and developed an accurate level-set based continuous surface reconstruction method on point clouds acquired by a 3D surface photogrammetry system. The proposed method has generated a continuous representation of the underlying phantom and patient surfaces with good robustness against noise and missing measurements. It serves as an important first step for further development of motion tracking methods during radiotherapy.

60 APPLIED LIFE SCIENCES↗

SU-C-207B-07: Deep Convolutional Neural Network Image Matching for Ultrasound Guidance in Radiotherapy

Purpose: Robust matching of ultrasound images is a challenging problem as images of the same anatomy often present non-trivial differences. This poses an obstacle for ultrasound guidance in radiotherapy. Thus our objective is to overcome this obstacle by designing and evaluating an image blocks matching framework based on a two channel deep convolutional neural network. Methods: We extend to 3D an algorithmic structure previously introduced for 2D image feature learning [1]. To obtain the similarity between two 3D image blocks A and B, the 3D image blocks are divided into 2D patches Ai and Bi. The similarity is then calculated as the average similarity score of Ai and Bi. The neural network was then trained with public non-medical image pairs, and subsequently evaluated on ultrasound image blocks for the following scenarios: (S1) same image blocks with/without shifts (A and A-shift-x); (S2) non-related random block pairs; (S3) ground truth registration matched pairs of different ultrasound images with/without shifts (A-i and A-reg-i-shift-x). Results: For S1 the similarity scores of A and A-shift-x were 32.63, 18.38, 12.95, 9.23, 2.15 and 0.43 for x=ranging from 0 mm to 10 mm in 2 mm increments. For S2 the average similarity score for non-related block pairs was −1.15. For S3 the average similarity score of ground truth registration matched blocks A-i and A-reg-i-shift-0 (1≤i≤5) was 12.37. After translating A-reg-i-shift-0 by 0 mm, 2 mm, 4 mm, 6 mm, 8 mm, and 10 mm, the average similarity scores of A-i and A-reg-i-shift-x were 11.04, 8.42, 4.56, 2.27, and 0.29 respectively. Conclusion: The proposed method correctly assigns highest similarity to corresponding 3D ultrasound image blocks despite differences in image content and thus can form the basis for ultrasound image registration and tracking.[1] Zagoruyko, Komodakis, “Learning to compare image patches via convolutional neural networks', IEEE CVPR 2015,pp.4353–4361.

60 APPLIED LIFE SCIENCES↗

WE-FG-207B-03: Multi-Energy CT Reconstruction with Spatial Spectral Nonlocal Means Regularization

Purpose: Multi-energy computed tomography (MECT) is an emerging application in medical imaging due to its ability of material differentiation and potential for molecular imaging. In MECT, image correlations at different spatial and channels exist. It is desirable to incorporate these correlations in reconstruction to improve image quality. For this purpose, this study proposes a MECT reconstruction technique that employes spatial spectral non-local means (ssNLM) regularization. Methods: We consider a kVp-switching scanning method in which source energy is rapidly switched during data acquisition. For each energy channel, this yields projection data acquired at a number of angles, whereas projection angles among channels are different. We formulate the reconstruction task as an optimziation problem. A least square term enfores data fidelity. A ssNLM term is used as regularization to encourage similarities among image patches at different spatial locations and channels. When comparing image patches at different channels, intensity difference were corrected by a transformation estimated via histogram equalization during the reconstruction process. Results: We tested our method in a simulation study with a NCAT phantom and an experimental study with a Gammex phantom. For comparison purpose, we also performed reconstructions using conjugate-gradient least square (CGLS) method and conventional NLM method that only considers spatial correlation in an image. ssNLM is able to better suppress streak artifacts. The streaks are along different projection directions in images at different channels. ssNLM discourages this dissimilarity and hence removes them. True image structures are preserved in this process. Measurements in regions of interests yield 1.1 to 3.2 and 1.5 to 1.8 times higher contrast to noise ratio than the NLM approach. Improvements over CGLS is even more profound due to lack of regularization in the CGLS method and hence amplified noise. Conclusion: The proposed ssNLM method for kVp-switching MECT reconstruction can achieve high quality MECT images.

60 APPLIED LIFE SCIENCES↗

Optimization of the Solubility of HIV-1-Neutralizing Antibody 10E8 through Somatic Variation and Structure-Based Design

Extraordinary antibodies capable of near pan-neutralization of HIV-1 have been identified. One of the broadest is antibody 10E8, which recognizes the membrane-proximal external region (MPER) of the HIV-1 envelope and neutralizes >95% of circulating HIV-1 strains. If delivered passively, 10E8 might serve to prevent or treat HIV-1 infection. Antibody 10E8, however, is markedly less soluble than other antibodies. Here, we describe the use of both structural biology and somatic variation to develop optimized versions of 10E8 with increased solubility. From the structure of 10E8, we identified a prominent hydrophobic patch; reversion of four hydrophobic residues in this patch to their hydrophilic germ line counterparts resulted in an ~10-fold decrease in turbidity. We also used somatic variants of 10E8, identified previously by next-generation sequencing, to optimize heavy and light chains; this process yielded several improved variants. Of these, variant 10E8v4 with 26 changes versus the parent 10E8 was the most soluble, with a paratope we showed crystallographically to be virtually identical to that of 10E8, a potency on a panel of 200 HIV-1 isolates also similar to that of 10E8, and a half-life in rhesus macaques of ~10 days. An anomaly in 10E8v4 size exclusion chromatography that appeared to be related to conformational isomerization was resolved by engineering an interchain disulfide. Furthermore, by combining a structure-based approach with natural variation in potency and solubility from the 10E8 lineage, we successfully created variants of 10E8 which retained the potency and extraordinary neutralization breadth of the parent 10E8 but with substantially increased solubility.

59 BASIC BIOLOGICAL SCIENCES↗

batteryNET v0.0.1

Code to organize, prepare, and segment multi-scan, larger-than-memory, volumetric dataset. Deep learning segmentation uses pytorch-lightning for code organization, logging and metrics, and multi-GPU parallelization of training and prediction. Also uses moani for volumetric data augmentation and model implementation (currently U-Net++). Training can be done slice-by-slice with 2D models trained on 2D patches either aligned with or perpendicular to the electrode plane, or with 3D models on 3D patches. Sparse labels can be used to minimize required hand-labeling -- less than 0.1% of the entire dataset was labeled. Also includes code for data preparation (alignment/cropping/patching).

Ushizima, Daniela↗

Turbulence and Cloudiness in Cumulus-Topped Marine Boundary Layers

Turbulence and cloudiness in cumulus-topped marine boundary layers are studied using data from the Atmospheric Radiation Measurement (ARM) Eastern North Atlantic (ENA) site. The analysis includes eight periods of nonprecipitating shallow cumulus clouds, spanning 141 h and encompassing 603 individual clouds. On average, the cumulus had bases at 558 m, were 99 m thick, had a chord length of 500 m, and exhibited an hourly base-layer cloudiness of 12%. Changes in cloud fraction were primarily driven by variations in cloud number not chord length. High-resolution Doppler lidar and cloud radar observations were used to estimate updraft and downdraft mass fluxes in the cumulus base layer under both clear and cloudy regions. Cloudy updrafts contributed only ∼23% of the total updraft mass flux at cloud base, indicating that most upward mass flux originated from clear-air eddies. Updraft strength, rather than updraft fraction, was found to predominantly control both clear and cloudy updraft mass fluxes. Cloud-base cloudiness strongly correlated with cloudy updraft mass flux but showed negligible correlation with clear-air updraft mass flux. Clear-air downdraft mass flux exhibited a strong relationship with the ratio of surface buoyancy to inversion strength. Mesoscale analysis revealed that moist patches had greater cloudiness, updraft mass flux, and vertical velocity variance compared to dry patches. Additionally, mesoscale base-layer cloud fraction was highly and significantly correlated with cloudy updraft mass flux in both dry and moist environments. Results presented herein have implications for cumulus parameterization development along with climatological and model evaluation studies conducted at the ENA site.

cumulus clouds↗