Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “particle filtering”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

CALIPSO Lidar Calibration at 532 nm: Version 4 Nighttime Algorithm

Data products from the Cloud-Aerosol Lidar with Orthogonal Polarization (CALIOP) on board Cloud-Aerosol Lidar and Infrared Pathfinder Satellite Observations (CALIPSO) were recently updated following the implementation of new (version 4) calibration algorithms for all of the level 1 attenuated backscatter measurements. In this work we present the motivation for and the implementation of the version 4 nighttime 532 nm parallel channel calibration. The nighttime 532 nm calibration is the most fundamental calibration of CALIOP data, since all of CALIOP’s other radiometric calibration procedures – i.e., the 532 nm daytime calibration and the 1064 nm calibrations during both nighttime and daytime – depend either directly or indirectly on the 532 nm nighttime calibration. The accuracy of the 532 nm nighttime calibration has been significantly improved by raising the molecular normalization altitude from 30-34 km to 36-39 km to substantially reduce stratospheric aerosol contamination. Due to the greatly reduced molecular number density and consequently reduced signal-to-noise ratio (SNR) at these higher altitudes, the signal is now averaged over a larger number of samples using data from multiple adjacent granules. As well, an enhanced strategy for filtering the radiation-induced noise from high energy particles was adopted. Further, the meteorological model used in the earlier versions has been replaced by the improved MERRA-2 model. An aerosol scattering ratio of 1.01 ± 0.01 is now explicitly used for the calibration altitude. These modifications lead to globally revised calibration coefficients which are, on average, 2-3% lower than in previous data releases. Further, the new calibration procedure is shown to eliminate biases at high altitudes that were present in earlier versions and consequently leads to an improved representation of stratospheric aerosols. Validation results using airborne lidar measurements are also presented. Biases relative to collocated measurements acquired by the Langley Research Center (LaRC) airborne high spectral resolution lidar (HSRL) are reduced from 3.6% ± 2.2% in the version 3 data set to 1.6% ± 2.4 % in the version 4 release.

Jayanta Kar↗

Automated SEM analysis of particles in Hanford tank waste

Multiple bench-scale filtration campaigns of Hanford tank waste supernatant on a backpulseable dead-end filtration skid have provided greater insight into the solids that cause fouling and reduce filter performance. The solids collected during each campaign were concentrated from the backpulse solutions and examined using automated particle analysis (APA) methods with scanning electron microscopy (SEM) and x-ray energy dispersive spectroscopy (EDS), to categorize particle types and their morphological characteristics. Finally, we show that with APA, thousands of particles can be analyzed that can provide accurate insight into the phases that may be impacting filter performance.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Structural characterization and gas reactions of small metal particles by high resolution in-situ TEM (Transmission Electron Microscopy) and TED (Transmission Electron Diffraction)

The detection and size analysis of small metal particles supported on amorphous substrates becomes increasingly difficult when the particle size approaches that of the phase contrast background structures of the support. An approach of digital image analysis, involving Fourier transformation of the original image, filtering, and image reconstruction was studied with respect to the likelihood of unambiguously detecting particles of less than 1 nm diameter on amorphous substrates from a single electron micrograph.

Heinemann, K.↗

Impacts of engine lubrication oil-derived ash on soot oxidative reactivity on a catalytic gasoline particulate filter

Characterizing soot oxidation kinetics is crucial for understanding how gasoline particulate filters (GPFs) perform both in terms of filtration efficiency and pressure drop. The most common method for measuring soot oxidative reactivity is thermogravimetric analysis (TGA). Because TGA is an offline method, it may inaccurately predict how soot oxidizes on a GPF, especially if a catalytic washcoat is present that may enhance oxidation rates through surface interactions as the soot loads on the filter. In this work, a novel in-situ soot oxidative reactivity measurement method was developed. The method involved loading a catalytic GPF under high temperature conditions conducive to soot oxidation and measuring the filtration efficiency of 100 nm particles. A correlation was made between filtration efficiency and loaded soot mass on the filter to allow calculation of the soot oxidation rate. The method was evaluated in experiments using a 2.0 L gasoline direct injection (GDI) engine with three oils of varying additive packages, including an oil with a high zinc dialkyldithiophosphate (ZDDP) concentration, a non-additive, pure poly-alpha olefin (PAO) oil, and an oil with a high concentration of calcium sulfonate. Calculated specific soot oxidation rates ranged from ~0.06–0.6 min –1 and showed strong dependence on GPF inlet gas temperature and lubrication oil additive type. The results clearly demonstrated a catalytic effect of calcium-containing ash particles. Reactivity of soot produced by the engine running with the high calcium containing lubrication oil was increased. Similarly, the results indicated that the catalytic washcoat on the filter increased soot oxidation rates on-filter, especially at low soot loading. Conversely, the ZDDP oil additive exhibited a reactivity inhibiting effect, resulting in lower soot oxidation rates. Finally, this work represents the first known in-situ soot oxidative reactivity measurements on a GPF and elucidates the effect of lubrication oil additives and catalytic washcoat on oxidation rate.

42 ENGINEERING↗

Preliminary Testing of Electrolytic Silver Ion Generation for Spacecraft Potable Water Systems

Anodic dissolution of silver electrodes, or “silver electrolysis,” is being investigated as a means of imparting biocidal silver into potable water on exploration spacecraft. This method of water disinfection is used commercially in hospitals and marine vessels, but the spacecraft application poses unique challenges such as low water conductivity, increased importance of electrode longevity, and an interface with other systems that may be sensitive to any particles released in the electrolysis process. Testing has shown that due to the low conductivity of the water, the electroactive area of the cell can be scaled linearly to achieve a target electrolysis current despite the general non-linearity of electrochemical systems. More importantly, however, the low conductivity dictates that a large electroactive area and minimal electrode gap be employed in the design. Furthermore, thermodynamic considerations suggest that a low applied voltage is necessary to avoid undesired electrode reactions that could negatively impact long-term performance. Preliminary testing of long-term electrode health suggests that anodic oxide formation may not present as significant a challenge as anticipated; however, further testing in a system closed to the atmosphere is required to rule out the influence of atmospheric CO2 on the pH of the process water. Comparison of filtered and unfiltered silver concentration measurements indicates that release of particles larger than 0.2 μm was negligible in this preliminary test. A test article has been developed to facilitate further testing of silver electrolysis, which continues to be a candidate technology for spacecraft potable water disinfection.

silver↗

Apparatus for photocatalytic treatment of liquids

Apparatus for decontaminating a contaminated fluid by using photocatalytic particles. The apparatus includes a reactor tank for holding a slurry of the contaminated fluid and the photocatalytic particles ultraviolet light irradiates the surface of the slurry, thereby activating the photocatalytic properties of the particles. Stirring blades for continuously agitate the irradiated fluid surface maintaining the particles in a suspended state within the fluid. A cross flow filter is used for separating the fluid from the semiconductor powder after the decomposition reaction is ended. The cross flow filter is occasionally back flushed to remove any caked semiconductor powder. The semiconductor powder may be recirculated back to the tank for reuse, or may be stored for future use. A series of reactor tanks may be used to gradually decompose a chemical in the fluid. The fluid may be pretreated to remove certain metal ions which interfere with the photocatalytic process. Such pretreatment may be accomplished by dispersing semiconductor particles within the fluid, which particles adsorb ions or photodeposit the metal as the free metal or its insoluble oxide or hydroxide, and then removing the semiconductor particles together with the adsorbed metal ions/oxides/hydroxide/free metal from the fluid.

Cooper, Gerald↗

Electric-field-driven Phenomena for Manipulating Particles in Micro-Devices

Compared to other available methods, ac dielectrophoresis is particularly well-suited for the manipulation of minute particles in micro- and nano-fluidics. The essential advantage of this technique is that an ac field at a sufficiently high frequency suppresses unwanted electric effects in a liquid. To date very little has been achieved towards understanding the micro-scale field-and shear driven behavior of a suspension in that, the concepts currently favored for the design and operation of dielectrophoretic micro-devices adopt the approach used for macro-scale electric filters. This strategy considers the trend of the field-induced particle motions by computing the spatial distribution of the field strength over a channel as if it were filled only with a liquid and then evaluating the direction of the dielectrophoretic force, exerted on a single particle placed in the liquid. However, the exposure of suspended particles to a field generates not only the dielectrophoretic force acting on each of these particles, but also the dipolar interactions of the particles due to their polarization. Furthermore, the field-driven motion of the particles is accompanied by their hydrodynamic interactions. We present the results of our experimental and theoretical studies which indicate that, under certain conditions, these long-range electrical and hydrodynamic interparticle interactions drastically affect the suspension behavior in a micro-channel due to its small dimensions.

Khusid, Boris↗

Ice Nucleation Spectrometer (INS) Instrument Handbook

The Ice Nucleation Spectrometer (INS) is an offline analytical measurement system used to process filter samples for freezing temperature spectra of immersion-mode ice nucleating particle (INP) number concentrations. It is almost identical to the CSU Ice Spectrometer (IS) design. While basic immersion freezing methods have been applied for decades, recent intercomparison studies (DeMott et al. 2017, 2018b) with other methods for sampling ambient INPs support the method’s utility. Use of the INS with filters produces spectra spanning wide dynamic ranges of temperature and, hence, INP concentration (e.g., six orders of magnitude). The INS is supported with well-established experimental protocols and has been applied in many diverse scenarios.

54 ENVIRONMENTAL SCIENCES↗

Localized Excitation of Electromagnetic Ion Cyclotron Waves From Anisotropic Protons Filtered by Magnetic Dips

The excitation of electrostatic and/or electromagnetic waves in the plasma universe is often associated with anisotropic velocity distributions of charged particles. In Earth's inner magnetosphere, this anisotropy can gradually develop as particles injected from the magnetotail drift around the Earth at different speeds depending on their energy and pitch angle. Here, we show that the perpendicular-moving and bouncing ions can be separated more abruptly near the injection front. These pitch-angle filters are localized magnetic dip structures formed by the diamagnetic behavior of the injected particles, which can trap perpendicular-moving ions and allow bouncing ions to overtake. The resulting ion anisotropy facilitates the rapid generation of electromagnetic ion cyclotron (EMIC) waves, which in turn can largely reshape the Van Allen radiation belts. This scenario is examined by case and statistical observations, together with numerical simulations that reproduce most of the observational signatures, to support the causal relationship between magnetic dips, anisotropic ion distributions, and localized excitation of EMIC waves. Finally, our study highlights the important roles of magnetic dips in the inner magnetospheric dynamics, as pitch-angle filters of the injected ions and traveling hotspots of EMIC wave activities.

79 ASTRONOMY AND ASTROPHYSICS↗

238 PuO 2 In Vitro Lung Dissolution Rate and Particle Size Determination for Material Involved in the June 8, 2020 Incident at the Los Alamos National Laboratory PF-4 Facility

As part of the LANL response to the June 8, 2020 238 PuO 2 inhalation exposure incident in PF-4, the Nuclear and Radiochemistry Group (C-NR) was asked to assist in determining the lung dissolution rate and particle size distribution of the airborne material. These material characteristics, along with urine and fecal bioassay data, are used by the Radiation Protection Services (RP-SVS) internal dosimetrists to refine dose estimates for exposed workers. Similar to previous studies, an in vitro lung dissolution rate study was performed to assess how fast 238 Pu is cleared from the lungs. Given that PuO 2 is a relatively insoluble material, it dissolves very slowly and requires in vitro studies of 100 or more days to estimate dissolution rates. This report details the results of a 100 day in vitro dissolution rate study and the particle size characteristics of 238 PuO 2 collected on an air filters during the incident. Results show that the 238 PuO 2 involved in this incident has behavior comparable to PuO 2 from previous in vitro studies, with approximately 1% of material dissolving quickly, and 99% of the material dissolving very slowly, with a half-time of approximately 120 years. This is somewhat slower than what was determined in a previous study of LANL 238 PuO 2 , which had an experimental dissolution half-time of 3 years, but significantly faster than 3000 years measured for 239 PuO 2 . Particle size distribution measurements indicate that particle sizes range from 0.10 µm – 6 µm, with most < 2 µm, which is reasonable based on our understanding of the process history of the 238 PuO 2 . Particle size, specific surface area, calcining temperature, specific activity, and age all are known factors that can impact the dissolution rate of refractory materials, however, there are too few studies to quantify the exact influence of these parameters on a measured dissolution rate. The results of this study add to that knowledge base, and provide new insights into the dissolution rates for this LANL process-specific 238 PuO 2 material.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Converting environmental wastes into valuable resources

This concept employs a viable energy saving method that uses a solvent to separate oil from particle matter; it can be used in metal forming industries to deoil sludges, oxides, and particle matter that is presently committed to landfill. If oily particles are used in their oily state, severe consequences to environmental control systems such as explosions or filter blinding, occur in the air handling equipment. This is due to the presence of hydrocarbons in the stack gasses resulting from the oily particles. After deoiling, the particles can be recycled and the separated oil can be used as a fuel. The process does not produce a waste of it's own and does not harm air or water. It demonstrates the dual benefits of it being commercially viable and in the national interest of conserving resources.

Duval, Leonard A.↗

Closed-Loop System Removes Contaminants From Inert Gas

Concentration of oxygen in this closed-loop system kept low by use of heated catalytic sorbent bed in cartridge. Proposed to keep concentration of water vapor low by use of predried zeolite sorbent bed in another cartridge, and to remove particles smaller than 0.1 micrometer by use of porous metal filters. In specific application, chamber is one in which semiconducting materials processed. By virtue of closed-loop operation, limited supply of inert gas adequate to provide atmosphere for industrial processing of semiconductors.

Sharma, Pramod K.↗

Absorption Filter Based Optical Diagnostics in High Speed Flows

Two major regimes where laser light scattered by molecules or particles in a flow contains significant information about the flow are Mie scattering and Rayleigh scattering. Mie scattering is used to obtain only velocity information, while Rayleigh scattering can be used to measure both the velocity and the thermodynamic properties of the flow. Now, recently introduced (1990, 1991) absorption filter based diagnostic techniques have started a new era in flow visualization, simultaneous velocity and thermodynamic measurements, and planar velocity measurements. Using a filtered planar velocimetry (FPV) technique, we have modified the optically thick iodine filter profile of Miles, et al., and used it in the pressure-broaden regime which accommodates measurements in a wide range of velocity applications. Measuring velocity and thermodynamic properties simultaneously, using absorption filtered based Rayleigh scattering, involves not only the measurement of the Doppler shift, but also the spectral profile of the Rayleigh scattering signal. Using multiple observation angles, simultaneous measurement of one component velocity and thermodynamic properties in a supersonic jet were measured. Presently, the technique is being extended for simultaneous measurements of all three components of velocity and thermodynamic properties.

Samimy, Mo↗

In-flight detection of small hypervelocity particles.

A technique is described in which small (25-micron) hypervelocity (10-km/sec) in-flight particles can be detected in the presence of high background noise. The system is based on a spatial filtering principle whereby spurious noise effects are reduced by use of a beam stop in the entrance aperture of the system and a bandpass filter in the transform plane. A theoretical analysis of the system is presented, and some experimental results are obtained by detecting in-flight hypervelocity particles generated by an exploding lithium wire electrothermal accelerator.

Robinson, D. M.↗

Electron Spectroscopy for Chemical Analysis (ESCA) study of atmospheric particles

The results of analyses by ESCA (Electron Spectroscopy for Chemical Analysis) on several Nuclepore filters which were exposed during air pollution studies are presented along with correlative measurements by Neutron Activation Analysis and Scanning Electron Microscopy. Samples were exposed during air pollution studies at Norfolk, Virginia and the NASA Kennedy Space Center (KSC). It was demonstrated that with the ESCA technique it was possible to identify the chemical (bonding) state of elements contained in the atmospheric particulate matter collected on Nuclepore filters. Sulfur, nitrogen, mercury, chlorine, alkali, and alkaline earth metal species were identified in the Norfolk samples. ESCA binding energy data for aluminum indicated that three chemically different types of aluminum are present in the launch and background samples from NASA-KSC.

Dillard, J. G.↗

Deep-Sea Hydrothermal-Vent Sampler

An apparatus is being developed for sampling water for signs of microbial life in an ocean hydrothermal vent at a depth of as much as 6.5 km. Heretofore, evidence of microbial life in deep-sea hydrothermal vents has been elusive and difficult to validate. Because of the extreme conditions in these environments (high pressures and temperatures often in excess of 300 C), deep-sea hydrothermal- vent samplers must be robust. Because of the presumed low density of biomass of these environments, samplers must be capable of collecting water samples of significant volume. It is also essential to prevent contamination of samples by microbes entrained from surrounding waters. Prior to the development of the present apparatus, no sampling device was capable of satisfying these requirements. The apparatus (see figure) includes an intake equipped with a temperature probe, plus several other temperature probes located away from the intake. The readings from the temperature probes are utilized in conjunction with readings from flowmeters to determine the position of the intake relative to the hydrothermal plume and, thereby, to position the intake to sample directly from the plume. Because it is necessary to collect large samples of water in order to obtain sufficient microbial biomass but it is not practical to retain all the water from the samples, four filter arrays are used to concentrate the microbial biomass (which is assumed to consist of particles larger than 0.2 m) into smaller volumes. The apparatus can collect multiple samples per dive and is designed to process a total volume of 10 L of vent fluid, of which most passes through the filters, leaving a total possibly-microbe-containing sample volume of 200 mL remaining in filters. A rigid titanium nose at the intake is used for cooling the sample water before it enters a flexible inlet hose connected to a pump. As the water passes through the titanium nose, it must be cooled to a temperature that is above a mineral-precipitation temperature of 100 C but below the upper working temperature (230 C) of switching valves and tubes in the apparatus. The sample water then passes into a manifold tube, from whence the switching valves can direct the water through either a bypass tube or any one of the filter arrays, without contamination from a previous sample. Each filter array consists of series of filters having pore sizes decreasing in the direction of flow: 90-, 60-, 15-, and 7-micron prefilters and a large-surface-area 0.2-micron collection filter. All the filter taps are located between the intake and the bypass tube so that each time the bypass tube is used, the entire manifold tube is flushed as well.

Behar, Alberto E.↗

Towards more accurate sound field verification using directional acoustic filtering

Attributing omnidirectional sound levels to a specific source in the ocean can be challenging when there are multiple competing sources of sound such as boats, or biological activity. Here, we present a method to directionally filter acoustic measurements based on vector measurements of acoustic pressure and particle velocity. The directional discrimination is applied to estimate sound energy from two marine energy sources: sound generated during the decommissioning of an oil platform and those from an operating tidal energy converter. The application of a directional mask leads to distinctly different spectra and some differences in energy, relative to the unmasked scenarios.

Barosin, Emily (ORCID:0009000765495939)↗

Full Submersion Water Testing of SAVY-4000 Nuclear Material Storage Containers

SAVY-4000 (SAVY) containers are the primary container used at Technical Area (TA) TA-55 plutonium facility for the prevention of water ingress to mitigate against a criticality event. The basis for water resistance of these containers has long been attributed to the Polytetrafluoroethylene (PTFE) membrane that is assembled on the outermost surface of the filter assembly. On August 22nd a test of a container used inside of a glovebox was performed that brought into question this long-standing-basis. This test was performed by inverting a SAVY-lid onto a specialized piece of equipment for evaluating the integrity of the PTFE membrane. During the test water was observed passing through the filter indicating that the filter membrane was no longer preventing the ingress of water through the filter. The assumption after making this observation was that alpha-particles were rapidly degrading the membrane creating a leak path through the underlying aluminosilicate media (Fiberfrax®). The apparatus used was designed to only test the lid rather than the entire SAVY assembly. A test plan, PA-PLAN-01921, was developed to investigate whether a fully assembled container with a fully degraded PTFE membrane would be capable of meeting the criteria defined in PA-RD-1009 of not allowing more than 200 ml of water to enter the container with a water column of 6-inches applied over a 2-hour period. This report provides the results of the testing performed against PA-PLAN-01921.

36 MATERIALS SCIENCE↗