Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “optimal accuracy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Firmware Development Improves System Efficiency

Most manufacturing processes require physical pointwise positioning of the components or tools from one location to another. Typical mechanical systems utilize either stop-and-go or fixed feed-rate procession to accomplish the task. The first approach achieves positional accuracy but prolongs overall time and increases wear on the mechanical system. The second approach sustains the throughput but compromises positional accuracy. A computer firmware approach has been developed to optimize this point wise mechanism by utilizing programmable interrupt controls to synchronize engineering processes 'on the fly'. This principle has been implemented in an eddy current imaging system to demonstrate the improvement. Software programs were developed that enable a mechanical controller card to transmit interrupts to a system controller as a trigger signal to initiate an eddy current data acquisition routine. The advantages are: (1) optimized manufacturing processes, (2) increased throughput of the system, (3) improved positional accuracy, and (4) reduced wear and tear on the mechanical system.

Chern, E. James↗

Fragment approach to constrained density functional theory calculations using Daubechies wavelets

In a recent paper, we presented a linear scaling Kohn-Sham density functional theory (DFT) code based on Daubechies wavelets, where a minimal set of localized support functions are optimized in situ and therefore adapted to the chemical properties of the molecular system. Thanks to the systematically controllable accuracy of the underlying basis set, this approach is able to provide an optimal contracted basis for a given system: accuracies for ground state energies and atomic forces are of the same quality as an uncontracted, cubic scaling approach. This basis set offers, by construction, a natural subset where the density matrix of the system can be projected. In this paper, we demonstrate the flexibility of this minimal basis formalism in providing a basis set that can be reused as-is, i.e., without reoptimization, for charge-constrained DFT calculations within a fragment approach. Support functions, represented in the underlying wavelet grid, of the template fragments are roto-translated with high numerical precision to the required positions and used as projectors for the charge weight function. We demonstrate the interest of this approach to express highly precise and efficient calculations for preparing diabatic states and for the computational setup of systems in complex environments.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

HPC Network Simulation Tuning via Automatic Extraction of Hardware Parameters

Popular HPC network interconnection simulators such as SST/macro provide a variety of configurable parameters to explore the design space of hardware components such as network interface cards (NIC), switches, and links among them. While such knobs provide flexibility to explore design trade-offs for novel hardware, manually configuring simulations for matching configurations of the existing hardware to focus on topology exploration can be cumbersome and error-prone, leading to widely inaccurate simulations. This challenge is compounded when specifications of various (proprietary) technologies are not readily available or intentionally omitted. In this work, we propose a framework to autotune the multiple network models’ simulation configurations within SST/macro using Tree-structured Parzen Estimator-based Bayesian optimization to observe the effect on simulation accuracy across different message regimes. These regimes consist of small to large message sizes and latency to bandwidth-bound messages. We provide a detailed analysis of the simulation error for four representative HPC systems. Our Bayesian optimization based autotuning framework for network models achieves a maximum of 5x improvement in accuracy over best-effort manual configurations based on available hardware specifications.

Simulation, autotuning↗

Balancing dose and image registration accuracy for cone beam tomosynthesis (CBTS) for breast patient setup

Purpose: To balance dose reduction and image registration accuracy in breast setup imaging. In particular, the authors demonstrate the relationship between scan angle and dose delivery for cone beam tomosynthesis (CBTS) when employed for setup verification of breast cancer patients with surgical clips. Methods: The dose measurements were performed in a female torso phantom for varying scan angles of CBTS. Setup accuracy was measured using three registration methods: Clip centroid localization accuracy and the accuracy of two semiautomatic registration algorithms. The dose to the organs outside of the ipsilateral breast and registration accuracy information were compared to determine the optimal scan angle for CBTS for breast patient setup verification. Isocenter positions at the center of the patient and at the breast-chest wall interface were considered. Results: Image registration accuracy was within 1 mm for the CBTS scan angles {theta} above 20 deg. for some scenarios and as large as 80 deg. for the worst case, depending on the imaged breast and registration algorithm. Registration accuracy was highest based on clip centroid localization. For left and right breast imaging with the isocenter at the chest wall, the dose to the contralateral side of the patient was very low (<0.5 cGy) for all scan angles considered. For central isocenter location, the optimal scan angles were 30 deg. - 50 deg. for the left breast imaging and 40 deg. - 50 deg. for the right breast imaging, with the difference due to the geometric asymmetry of the current clinical imaging system. Conclusions: The optimal scan angles for CBTS imaging were found to be between 10 deg. and 50 deg., depending on the isocenter location and ipsilateral breast. Use of the isocenter at the breast-chest wall locations always resulted in greater accuracy of image registration (<1 mm) at smaller angles (10 deg. - 20 deg.) and at lower doses (<0.1 cGy) to the contralateral organs. For chest wall isocenters, doses delivered to organs outside of the target breast were much smaller than the scattered and leakage doses of the treatment beams. The complete volumetric information of all clips in the region of interest, combined with the small dose to the contralateral organs and the small scan angle, could result in an advantage for small angle CBTS with off center isocenters over simple orthogonal pairs.

60 APPLIED LIFE SCIENCES↗

Optimization-based, property-preserving algorithm for passive tracer transport

Here we present a new optimization-based property-preserving algorithm for passive tracer transport. The algorithm utilizes a semi-Lagrangian approach based on incremental remapping of the mass and the total tracer. However, unlike traditional semi-Lagrangian schemes, which remap the density and the tracer mixing ratio through monotone reconstruction or flux correction, we utilize an optimization-based remapping that enforces conservation and local bounds as optimization constraints. In so doing we separate accuracy considerations from preservation of physical properties to obtain a conservative, second-order accurate transport scheme that also has a notion of optimality. Moreover, we prove that the optimization-based algorithm preserves linear relationships between tracer mixing ratios. We illustrate the properties of the new algorithm using a series of standard tracer transport test problems in a plane and on a sphere.

97 MATHEMATICS AND COMPUTING↗

Format for Interchange and Display of 3D Terrain Data

Visible Scalable Terrain (ViSTa) is a software format for production, interchange, and display of three-dimensional (3D) terrain data acquired by stereoscopic cameras of robotic vision systems. ViSTa is designed to support scalability of data, accuracy of displayed terrain images, and optimal utilization of computational resources. In a ViSTa file, an area of terrain is represented, at one or more levels of detail, by coordinates of isolated points and/or vertices of triangles derived from a texture map that, in turn, is derived from original terrain images. Unlike prior terrain-image software formats, ViSTa includes provisions to ensure accuracy of texture coordinates. Whereas many such formats are based on 2.5-dimensional terrain models and impose additional regularity constraints on data, ViSTa is based on a 3D model without regularity constraints. Whereas many prior formats require external data for specifying image-data coordinate systems, ViSTa provides for the inclusion of coordinate-system data within data files. ViSTa admits highspeed loading and display within a Java program. ViSTa is designed to minimize file sizes and maximize compressibility and to support straightforward reduction of resolution to reduce file size for Internet-based distribution.

Backes, Paul↗

Computer-aided diagnosis for classifying benign versus malignant thyroid nodules based on ultrasound images: A comparison with radiologist-based assessments

Purpose: To develop a semiautomated computer-aided diagnosis (CAD) system for thyroid cancer using two-dimensional ultrasound images that can be used to yield a second opinion in the clinic to differentiate malignant and benign lesions. Methods: A total of 118 ultrasound images that included axial and longitudinal images from patients with biopsy-confirmed malignant (n = 30) and benign (n = 29) nodules were collected. Thyroid CAD software was developed to extract quantitative features from these images based on thyroid nodule segmentation in which adaptive diffusion flow for active contours was used. Various features, including histogram, intensity differences, elliptical fit, gray-level co-occurrence matrixes, and gray-level run-length matrixes, were evaluated for each region imaged. Based on these imaging features, a support vector machine (SVM) classifier was used to differentiate benign and malignant nodules. Leave-one-out cross-validation with sequential forward feature selection was performed to evaluate the overall accuracy of this method. Additionally, analyses with contingency tables and receiver operating characteristic (ROC) curves were performed to compare the performance of CAD with visual inspection by expert radiologists based on established gold standards. Results: Most univariate features for this proposed CAD system attained accuracies that ranged from 78.0% to 83.1%. When optimal SVM parameters that were established using a grid search method with features that radiologists use for visual inspection were employed, the authors could attain rates of accuracy that ranged from 72.9% to 84.7%. Using leave-one-out cross-validation results in a multivariate analysis of various features, the highest accuracy achieved using the proposed CAD system was 98.3%, whereas visual inspection by radiologists reached 94.9% accuracy. To obtain the highest accuracies, “axial ratio” and “max probability” in axial images were most frequently included in the optimal feature sets for the authors’ proposed CAD system, while “shape” and “calcification” in longitudinal images were most frequently included in the optimal feature sets for visual inspection by radiologists. The computed areas under curves in the ROC analysis were 0.986 and 0.979 for the proposed CAD system and visual inspection by radiologists, respectively; no significant difference was detected between these groups. Conclusions: The use of thyroid CAD to differentiate malignant from benign lesions shows accuracy similar to that obtained via visual inspection by radiologists. Thyroid CAD might be considered a viable way to generate a second opinion for radiologists in clinical practice.

61 RADIATION PROTECTION AND DOSIMETRY↗

Learning Optimal Aerodynamic Designs

This project created a framework for efficient, accurate, and scalable deep neural network representations of design optimization problem solutions. The inputs to these DNN representations are the vector of design requirement parameters, the outputs are the optimal design variables, and the goal is to learn the map from inputs to outputs (i.e., inverse design). The team addressed the problem of the optimal shape design of aerodynamic lifting surfaces—in particular aircraft wings—using a Reynolds-Average Navier Stokes model to govern the CFD-based aerodynamic shape optimization. The inverse design map for such problems is very complex and high-dimensional, involving inputs and outputs on the order of 1000s. To approximate this inverse design map, the team developed algorithms to construct parsimonious DNN architectures, which automatically identify low-dimensional manifolds in which design requirements affect optimal shape parameters, and trained these architectures with multifidelity optimization methods. The resulting methodology accurately and automatically designs optimal aerodynamic lifting surfaces with very high accuracy (99%) at interactive speeds, of the order of milliseconds, resulting in factors of one million or more speedup relative to CFD-based design optimization.

97 MATHEMATICS AND COMPUTING↗

Sea-Ice Effects on the Alaskan Wave Climate

This study investigates the uncertainty of wave resource assessments due to sea ice in the nearshore region of Alaska using an innovative approach of combining remotely sensed data and a third-generation phase-averaged wave model. Modeling analysis focused on winter months, when high wave energy is present along with sea ice. This study includes recommendations to improve the accuracy of wave resource assessments and optimize marine and hydrokinetic device siting with consideration of sea-ice effects. Additional recommendations, based on preliminary sea-ice information in Cook Inlet, Alaska, are provided for a trajectory analysis of drifting sea ice and a collision risk assessment of sea ice and tidal turbines. The outcome of this project will provide valuable information about the level of sea-ice impact on the accuracy of wave resource assessments in the Alaska nearshore region, and of sea-ice collision risk with MHK devices and ocean observation systems during winter months when sea ice is present.

16 TIDAL AND WAVE POWER↗

Optimal artificial neural network architecture selection for performance prediction of compact heat exchanger with the EBaLM-OTR technique

Artificial Neural Networks (ANN) have been used in the past to predict the performance of printed circuit heat exchangers (PCHE) with satisfactory accuracy. Typically published literature has focused on optimizing ANN using a training dataset to train the network and a testing dataset to evaluate it. Although this may produce outputs that agree with experimental results, there is a risk of over-training or overlearning the network rather than generalizing it, which should be the ultimate goal. An over-trained network is able to produce good results with the training dataset but fails when new datasets with subtle changes are introduced. In this paper we present EBaLM-OTR (error back propagation and Levenberg-Marquardt algorithms for over training resilience) technique, which is based on a previously discussed method of selecting neural network architecture that uses a separate validation set to evaluate different network architectures based on mean square error (MSE), and standard deviation of MSE. The method uses k-fold cross validation. Therefore in order to select the optimal architecture for the problem, the dataset is divided into three parts which are used to train, validate and test each network architecture. Then each architecture is evaluated according to their generalization capability and capability to conform to original data. The method proved to be a comprehensive tool in identifying the weaknesses and advantages of different network architectures. The method also highlighted the fact that the architecture with the lowest training error is not always the most generalized and therefore not the optimal. Using the method the testing error achieved was in the order of magnitude of within 10{sup -5} - 10{sup -3}. It was also show that the absolute error achieved by EBaLM-OTR was an order of magnitude better than the lowest error achieved by EBaLM-THP.

99 GENERAL AND MISCELLANEOUS↗

M11plus: A Range-Separated Hybrid Meta Functional with Both Local and Rung-3.5 Correlation Terms and High Across-the-Board Accuracy for Chemical Applications

The way to improve Kohn–Sham density functional theory is to improve the exchange–correlation functionals, and functionals have been successively improved by adding new ingredients, especially local spin density gradients, nonlocal Hartree–Fock exchange, and local meta terms based on kinetic energy density. Here, we present a new kind of functional obtained by adding rung-3.5 terms to a functional including local gradients, local meta terms, and range-separated Hartree–Fock exchange. A rung-3.5 term has short-range nonlocality designed to account for nondynamic correlation; we add two kinds of rung-3.5 terms, one kind modeled on position-dependent Hartree–Fock exchange and another modeled on the spin density at a point interacting with the opposite-spin exchange hole at the same point. Here, optimization of the functional yields broad accuracy for both ground states and excited states with especially significant improvement for systems with strong correlation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Direct discontinuous Galerkin method and its variations for second order elliptic equations

In this study, we study direct discontinuous Galerkin method (Liu and Yan in SIAM J Numer Anal 47(1):475–698, 2009) and its variations (Liu and Yan in Commun Comput Phys 8(3):541–564, 2010; Vidden and Yan in J Comput Math 31(6):638–662, 2013; Yan in J Sci Comput 54(2–3):663–683, 2013) for 2nd order elliptic problems. A priori error estimate under energy norm is established for all four methods. Optimal error estimate under L 2 norm is obtained for DDG method with interface correction (Liu and Yan in Commun Comput Phys 8(3):541–564, 2010) and symmetric DDG method (Vidden and Yan in J Comput Math 31(6):638–662, 2013). A series of numerical examples are carried out to illustrate the accuracy and capability of the schemes. Numerically we obtain optimal (k+1)th order convergence for DDG method with interface correction and symmetric DDG method on nonuniform and unstructured triangular meshes. An interface problem with discontinuous diffusion coefficients is investigated and optimal (k+1)th order accuracy is obtained. Peak solutions with sharp transitions are captured well. Highly oscillatory wave solutions of Helmholz equation are well resolved.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

SU-E-T-175: Clinical Evaluations of Monte Carlo-Based Inverse Treatment Plan Optimization for Intensity Modulated Radiotherapy

Purpose: Pencil-beam or superposition-convolution type dose calculation algorithms are routinely used in inverse plan optimization for intensity modulated radiation therapy (IMRT). However, due to their limited accuracy in some challenging cases, e.g. lung, the resulting dose may lose its optimality after being recomputed using an accurate algorithm, e.g. Monte Carlo (MC). It is the objective of this study to evaluate the feasibility and advantages of a new method to include MC in the treatment planning process. Methods: We developed a scheme to iteratively perform MC-based beamlet dose calculations and plan optimization. In the MC stage, a GPU-based dose engine was used and the particle number sampled from a beamlet was proportional to its optimized fluence from the previous step. We tested this scheme in four lung cancer IMRT cases. For each case, the original plan dose, plan dose re-computed by MC, and dose optimized by our scheme were obtained. Clinically relevant dosimetric quantities in these three plans were compared. Results: Although the original plan achieved a satisfactory PDV dose coverage, after re-computing doses using MC method, it was found that the PTV D95% were reduced by 4.60%–6.67%. After re-optimizing these cases with our scheme, the PTV coverage was improved to the same level as in the original plan, while the critical OAR coverages were maintained to clinically acceptable levels. Regarding the computation time, it took on average 144 sec per case using only one GPU card, including both MC-based beamlet dose calculation and treatment plan optimization. Conclusion: The achieved dosimetric gains and high computational efficiency indicate the feasibility and advantages of the proposed MC-based IMRT optimization method. Comprehensive validations in more patient cases are in progress.

60 APPLIED LIFE SCIENCES↗

CUDO: closed-form universal dwell-time optimization for computer-controlled optical surfacing

Precision optical figuring demands fast and accurate dwell time optimization to reach nanometer- and sub-nanometer-level accuracy in next-generation optical systems. We introduce CUDO (closed-form universal dwell-time optimization), the first, to the best of our knowledge, unified closed-form analytical framework that supports both function-form and matrix-form dwell time models in computer-controlled optical surfacing (CCOS). In contrast to traditional methods, which rely on iterative optimization and hyperparameter tuning, our framework derives direct analytical solutions with no adjustable parameters. This approach unifies the solution principles of existing methods within a single mathematical model, delivering three key advantages: (1) accuracy on par with, or superior to, iterative solvers, (2) substantial reduction in computation time, and (3) numerical robustness. Comparative studies with prior art confirm that closed-form solutions achieve equivalent residual error while removing runtime bottlenecks. By simplifying the implementation and enabling real-time, scalable deployment, CUDO establishes a practical foundation for future deterministic fabrication of large-aperture and high-performance optics.

36 MATERIALS SCIENCE↗

A Kinematic Calibration Process for Flight Robotic Arms

The Mars Science Laboratory (MSL) robotic arm is ten times more massive than any Mars robotic arm before it, yet with similar accuracy and repeatability positioning requirements. In order to assess and validate these requirements, a higher-fidelity model and calibration processes were needed. Kinematic calibration of robotic arms is a common and necessary process to ensure good positioning performance. Most methodologies assume a rigid arm, high-accuracy data collection, and some kind of optimization of kinematic parameters. A new detailed kinematic and deflection model of the MSL robotic arm was formulated in the design phase and used to update the initial positioning and orientation accuracy and repeatability requirements. This model included a higher-fidelity link stiffness matrix representation, as well as a link level thermal expansion model. In addition, it included an actuator backlash model. Analytical results highlighted the sensitivity of the arm accuracy to its joint initialization methodology. Because of this, a new technique for initializing the arm joint encoders through hardstop calibration was developed. This involved selecting arm configurations to use in Earth-based hardstop calibration that had corresponding configurations on Mars with the same joint torque to ensure repeatability in the different gravity environment. The process used to collect calibration data for the arm included the use of multiple weight stand-in turrets with enough metrology targets to reconstruct the full six-degree-of-freedom location of the rover and tool frames. The follow-on data processing of the metrology data utilized a standard differential formulation and linear parameter optimization technique.

Collins, Curtis L.↗

Neural Networks for Prediction of Complex Chemistry in Water Treatment Process Optimization

Water chemistry plays a critical role in the design and operation of water treatment processes. Detailed chemistry modeling tools use a combination of advanced thermodynamic models and extensive databases to predict phase equilibria and reaction phenomena. The complexity and formulation of these models preclude their direct integration in equation-oriented modeling platforms, making it difficult to use their capabilities for rigorous water treatment process optimization. Neural networks (NN) can provide a pathway for integrating the predictive capability of chemistry software into equation-oriented models and enable optimization of complex water treatment processes across a broad range of conditions and process designs. Herein, we assess how NN architecture and training data impact their accuracy and use in equation-oriented water treatment models. We generate training data using PhreeqC software and determine how data generation and sample size impact the accuracy of trained NNs. The effect of NN architecture on optimization is evaluated by optimizing hypothetical black-box desalination processes using a range of feed compositions from USGS brackish water data set, tracking the number of successful optimizations, and testing the impact of initial guess on the final solution. Our results clearly demonstrate that data generation and architecture impact NN accuracy and viability for use in equation-oriented optimization problems.

Dudchenko, Alexander V↗

Optimization of FRAM precision for isotopic measurements on large samples of low-burnup PuO2

The gamma ray spectrum of plutonium contains measurable gamma rays ranging in energy from 60 keV to above 1 MeV. The FRAM gamma ray isotopic analysis code can analyze data from all types of HPGe detectors in this energy range typically using planar detectors in the energy range 60-210 keV or 120-451 keV and using coaxial detectors in the energy ranges 120-451 keV or 200-1001 keV. The statistical measurement precision depends upon the detector/energy range combination as well as the characteristics of the sample and any addition filters. In this paper we carry out the optimization of measurement precision for the important case of a multi-kg sample of low bumup PuO{sub 2} contained in a DOE 3013 Standard-compatible long-teml storage container.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A physics-based model for industrial steam-methane reformer optimization with non-uniform temperature field

In an industrial hydrogen production facility, steam-methane reforming reactions take place inside hundreds of catalyst-filled tubes placed in a large scale, high temperature furnace. Process efficiency depends strongly on the wall temperature distribution of the ensemble of reformer tubes; a narrower distribution has a process intensification effect, by providing similar processing experience to every feedstock molecule. Such process intensification efforts require a furnace model that can predict the temperature distribution as a function of operating conditions. Currently available furnace modeling solutions are either computationally intensive, making them unsuitable for (online) optimization calculations, or empirical, having limited accuracy when wide changes in operating conditions are required. Here in this work, a physics-based furnace model is presented that overcomes these limitations. Empirical perturbations in a Hottel zone radiation model are proposed to capture the spatially non-symmetrical temperature distribution. The low computational time makes the model suitable for operational intensification based on reduction of temperature distribution non-uniformity.

42 ENGINEERING↗