Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “optical Interferometer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

CGH Figure Testing of Aspherical Mirrors in Cold Vacuums

An established method of room-temperature interferometric null testing of mirrors having simple shapes (e.g., flat, spherical, or spheroidal) has been augmented to enable measurement of errors in the surface figures of off-axis, non-axisymmetric, aspherical mirrors when the mirrors are located inside cryogenic vacuum chambers. The established method involves the use of a computer-generated hologram (CGH), functionally equivalent to a traditional null lens, to modify the laser beam of an imaging interferometer to obtain a reference wavefront that matches the ideal surface figure of a mirror under test. The CGH is inserted at the appropriate position and orientation in the optical path of the imaging interferometer, which, in turn, is appropriately positioned and oriented with respect to the mirror under test. Deviations of the surface figure of the mirror from the ideal surface figure manifest themselves as interference fringes. Interferograms are recorded and analyzed to deduce figure errors.

Chambers, Victor John↗

Multiple spacecraft Michelson stellar interferometer

Results of an orbital analysis and performance assessment of SAMSI (Spacecraft Array for Michelson Spatial Interferometry) are presented. The device considered includes two one-meter telescopes in orbits which are identical except for slightly different inclinations; the telescopes achieve separations as large as 10 km and relay starlight to a central station which has a one-meter optical delay line in one interferometer arm. It is shown that a 1000-km altitude, zero mean inclination orbit affords natural scanning of the 10-km baseline with departures from optical pathlength equality which are well within the corrective capacity of the optical delay line. Electric propulsion is completely adequate to provide the required spacecraft motions, principally those needed for repointing. Resolution of 0.00001 arcsec and magnitude limits of 15 to 20 are achievable.

Stachnik, R. V.↗

Balloon borne optical disk mass storage system

An on-board data recording system for balloon-borne interferometer using a vacuum operable, ruggedized WORM optical drive is presented. This system, as presently under development, provides 320 Mbytes of data storage (or approximately 11 hrs at the 64 kbits/sec telemetry rate of the experiment). It has the capability of recording the unmodified telemetry bit system as transmitted or doing some preprocessing of the data onboard. The system is compact and requires less than 28 watts of battery power to operate.

Vanek, M. D.↗

Cryogenic Optical Systems and Instrumentation IX (AM 116) Newly Modified Cryogenic Optical Test Facility at the Marshall Space Flight Center

Marshall Space Flight Center (MSFC) has maintained and operated a world-class x-ray optics and detector testing facility known as the X-ray Calibration Facility (XRCF) since the mid 1970's. The ground test and calibration of the Chandra X-ray Observatory optics and detectors were successfully completed at the XRCF in 1997. The beginning of the Next Generation Space Telescope (NGST) development programs (NMSD, SBMD, AMSD, etc.) and the establishment of the Space Optics Manufacturing Technology Center at MSFC have led to an XRCF modification. In 1999 the facility was upgraded to perform cryogenic testing of lightweight visible optics (without compromising the existing x-ray testing capability). A thermal enclosure capable of 20 degrees Kelvin and vibration isolated instrumentation mount were added. A vacuum-compatible five-axis motion table was modified to operate under cryogenic conditions. Optics up to two meters in diameter with radii of curvature of up to twenty meters can be accommodated. Facility characterization tests and one NGST program mirror test have been completed to date. By July 2000, two other mirrors will be tested. Optical wavefront measurements were made at < 35 degrees Kelvin with several instruments located at the test mirror's radius of curvature. The current wavefront measuring instruments include a Shack-Hartman wavefront sensor, a point diffraction interferometer, a point spread function-measuring device, and a radius of curvature measuring instrument. A vibration insensitive phase shifting interferometer is planned for future optical testing. This paper will present a brief history of the facility, a discussion of its current x-ray optic testing capabilities, and a complete description of the new capabilities in the visible optical testing regime.

Eng, Ronnie↗

Two-color method for optical astrometry - Theory and preliminary measurements with the Mark III stellar interferometer

The two-color method for interferometric astrometry provides a means of reducing the error in a stellar position measurement attributable to atmospheric turbulence. The primary limitation of the method is shown to be turbulent water vapor fluctuations. Secondary atmospheric effects caused by diffraction from small refractive-index inhomogeneities and differential refraction for the observation of stars away from zenith are shown to introduce errors that behave as white noise and which should not be significant. Other potential error sources due to photon noise, systematic instrumental effects, and imperfect data reduction are also considered. The improvement in accuracy possible with the two-color method is estimated as a factor of 5-10 over the corresponding one-color measurement. Some preliminary two-color measurements with the Mark III stellar interferometer at Mt. Wilson are presented, which demonstrate a factor of about 5 reduction in the amplitude of the atmospheric fluctuations in a stellar position measurement.

Colavita, M. Mark↗

Long-term stability of a Fabry-Perot interferometer used for measurement of stellar Doppler shift

The use of a fiber-optic-link CCD-detector Fabry-Perot interferometer (McMillan et al., 1985, 1986, and 1988) to obtain high-accuracy measurements of stellar Doppler shifts at KPNO is described in detail and illustrated with sample data. Particular attention is given to accuracy requirements and techniques for reducing errors, resolution (orders of 50 mA at wavelength 4300 A are separated by 640 mA), CCD sensitivity, observing and data-processing operations, and the control of environmental conditions. Standard-deviation data and statistics on seven solar-type stars are presented in tables, and the time evolution of the radial velocity of Beta Com is shown in a graph.

Mcmillan, R. S.↗

GAIA and beyond: The perspective from the milliarcseconds of Hubble and Hipparcos

Astrometry with the Hubble space telescope and Hipparcos satellite advanced the optical astrometric accuracies to the milliarcsec level. The global astrometric interferometer for astrophysics (GAIA) satellite and other proposed optical interferometry space missions would advance the optical astrometric accuracy to better than 10 microarcsec. A catalog figure of merit is defined which allows a quantitative comparison to be carried out for astrometric catalogs. Using two specific astrophysical problems, the level of the expected scientific contribution from a GAIA-type mission is assessed. The two problems are: the age of the globular clusters in relation to the age of the Universe, and the initial mass function compared with fluctuations in the star formation rate with time.

Hemenway, Paul D.↗

Interferometers Sharpen Measurements for Better Telescopes

Over the last decade, there have been a number of innovations that have made possible the largest and most powerful telescope of its time: the James Webb Space Telescope (JWST). Scheduled to launch in 2018, JWST will provide insight into what the oldest, most distant galaxies look like. When engineers build a first-of-its-kind instrument like the JWST, they often must make new tools to construct the new technology. Throughout the decades of planning, development, and construction of the JWST, NASA has worked with numerous partners to spur innovations that have enabled the telescope s creation. Though the JWST s launch date is still several years away, a number of these innovations are spinning off to provide benefits here on Earth. One of these spinoffs has emerged from the extensive testing the JWST must undergo to ensure it will function in the extreme environment of space. In order to test the JWST instruments in conditions that closely resemble those in space, NASA uses a cryogenic vacuum chamber. By dropping the temperatures down to -400 F and employing powerful pumps to remove air from the chamber, engineers can test whether the JWST instruments will function once the spacecraft leaves Earth. Traditionally, a phase-shifting interferometer is used to measure optics like the JWST s mirrors to verify their precise shape, down to tens of nanometers, during manufacturing. However, the large size of the mirrors, coupled with vibration induced by the cryo-pumps, prohibits the use of traditional phase-shifting interferometers to measure the mirrors within the chamber environment. Because the JWST will be located in deep space, far from any possible manned service mission, it was essential to find a robust solution to guarantee the performance of the mirrors.

Source record↗

System and Method for Scan Range Gating

A system for scanning light to define a range gated signal includes a pulsed coherent light source that directs light into the atmosphere, a light gathering instrument that receives the light modified by atmospheric backscatter and transfers the light onto an image plane, a scanner that scans collimated light from the image plane to form a range gated signal from the light modified by atmospheric backscatter, a control circuit that coordinates timing of a scan rate of the scanner and a pulse rate of the pulsed coherent light source so that the range gated signal is formed according to a desired range gate, an optical device onto which an image of the range gated signal is scanned, and an interferometer to which the image of the range gated signal is directed by the optical device. The interferometer is configured to modify the image according to a desired analysis.

Zuk, David M.↗

Large-aperture interferometer using local reference beam

A large-aperture interferometer was devised by adding a local-reference-beam-generating optical system to a schlieren system. Two versions of the interferometer are demonstrated, one employing 12.7 cm (5 in.) diameter schlieren optics, the other employing 30.48 cm (12 in.) diameter parabolic mirrors in an off-axis system. In the latter configuration a cylindrical lens is introduced near the light source to correct for astigmatism. A zone plate is a satisfactory decollimating element in the reference-beam arm of the interferometer. Attempts to increase the flux and uniformity of irradiance in the reference beam by using a diffuser are discussed.

Howes, W. L.↗

Large-aperture interferometer with local reference beam

A large-aperture interferometer was devised by adding a local-reference-beam-generating optical system to a schlieren system. Two versions of the interferometer are demonstrated, one employing 12.7 cm (5 in.) diameter schlieren optics, the other employing 30.48 cm (12 in.) diameter parabolic mirrors in an off-axis system. In the latter configuration a cylindrical lens is introduced near the light source to correct for astigmatism. A zone plate is a satisfactory decollimating element in the reference-beam arm of the interferometer. Attempts to increase the flux and uniformity of irradiance in the reference beam by using a diffuser are discussed. Previously announced in STAR as N83-13979

Howes, W. L.↗

Application of optical methods to the study of jet noise and turbulence

Optical methods are generally applied in fluid mechanics for either visualization or measurement. The use of a laser anemometer to study flow velocity in a jet and its relaton to the sound radiated is described. The same acoustic emission phenomenon is also measued by combining the signals from four Schlieren systems with that from an interferometer. The use of an optical Fourier transformation approach with real time analysis to determine the spatio-temporal structure of a field of mass volume such as a waveguide or free jet is also examined.

Sava, P. G.↗

Optical fiber sensors for damage analysis in aerospace materials

Under this grant, fiber optic sensors were investigated for use in the nondestructive evaluation of aging aircraft. Specifically, optical fiber sensors for detection and location of impacts on a surface, and for detection of corrosion in metals were developed. The use of neural networks was investigated for determining impact location by processing the output of a network of fiberoptic strain sensors distributed on a surface. This approach employs triangulation to determine location by comparing the arrival times at several sensors, of the acoustic signal generated by the impact. For this study, a neural network simulator running on a personal computer was used to train a network using a back-propagation algorithm. Fiber optic extrinsic Fabry-Perot interferometer (EFPI) strain sensors are attached to or embedded in the surface, so that stress waves emanating from an impact can be detected. The ability of the network to determine impact location by time-or-arrival of acoustic signals was assessed by comparing network outputs with actual experimental results using impacts on a panel instrumented with optical fiber sensors. Using the neural network to process the sensor outputs, the impact location can be inferred to centimeter range accuracy directly from the arrival time data. In addition, the network can be trained to determine impact location, regardless of material anisotropy. Results demonstrate that a back-propagation network identifies impact location for an anisotropic graphite/bismaleimide plate with the same accuracy as that for an isotropic aluminum plate. Two different approaches were investigated for the development of fiber optic sensors for corrosion detection in metals, both utilizing optical fiber sensors with metal coatings. In the first approach, an extrinsic Fabry-Perot interferometric fiber optic strain sensor was placed under tensile stress, and while in the resulting strained position, a thick coating of metal was applied. Due to an increase in the quantity of material, the sensor does not return to its original position upon removal of the applied stress, and some residual strain is maintained within the sensor element. As the metal thickness decreases due to corrosion, this strain is released, providing the sensing mechanism for corrosion detection. In the second approach, photosensitive optical fibers with long period Bragg gratings in the core were coated with metal. The Bragg gratings serve to couple core modes at discrete wavelengths to cladding modes. Since cladding modes interact with the metal coating surrounding the fiber cladding, the specific wavelengths coupled from core to cladding depend on the refractive index of the metal coating. Therefore, as the metal corrodes, the resulting change in index of the coating may be measured by measuring the change in wavelength of the coupled mode. Results demonstrate that both approaches can be successfully used to track the loss in metal coating on the optical fiber sensors due to corrosion.

Schindler, Paul↗

Performance of the Primary Mirror Center-of-curvature Optical Metrology System During Cryogenic Testing of the JWST Pathfinder Telescope

The James Webb Space Telescope (JWST) primary mirror (PM) is 6.6 m in diameter and consists of 18 hexagonal segments, each 1.5 m point-to-point. Each segment has a six degree-of-freedom hexapod actuation system and a radius-of-curvature (RoC) actuation system. The full telescope will be tested at its cryogenic operating temperature at Johnson Space Center. This testing will include center-of-curvature measurements of the PM, using the Center-of-Curvature Optical Assembly (COCOA) and the Absolute Distance Meter Assembly (ADMA). The COCOA includes an interferometer, a reflective null, an interferometer-null calibration system, coarse & fine alignment systems, and two displacement measuring interferometer systems. A multiple-wavelength interferometer (MWIF) is used for alignment & phasing of the PM segments. The ADMA is used to measure, and set, the spacing between the PM and the focus of the COCOA null (i.e. the PM center-of-curvature) for determination of the ROC. The performance of these metrology systems was assessed during two cryogenic tests at JSC. This testing was performed using the JWST Pathfinder telescope, consisting mostly of engineering development & spare hardware. The Pathfinder PM consists of two spare segments. These tests provided the opportunity to assess how well the center-of-curvature optical metrology hardware, along with the software & procedures, performed using real JWST telescope hardware. This paper will describe the test setup, the testing performed, and the resulting metrology system performance. The knowledge gained and the lessons learned during this testing will be of great benefit to the accurate & efficient cryogenic testing of the JWST flight telescope.

optical testing↗

Suppressing Spurious Reflections In An Interferometer

Dynamic-aperture fringe discriminator is simple device enhancing operation of interferometer of spherical-wave-front type used to test lenses, telescopes, and other optical instruments. Device suppresses reflections from surfaces of refractive optical elements in instrument and/or test setup. Reflections from refractive optical components eliminated by blocking half of interferometer aperture.

Steimle, Lawrence J.↗

Bell Inequality Experiment for a High Brightness Time-Energy Entangled Source

A periodically poled MgO doped LiNbO3 (MgO:LN) non-degenerate photon pair source is utilized for spontaneous parametric down-conversion of 532 nm photons into time-energy entangled pairs of 800 and 1600 nm photons. The entangled photons are separated using previously detailed sorting optics, such that each wavelength is independently directed through one of two modified Mach-Zehnder interferometers also known as a Franson interferometer after which they are fiber-optically guided to high-efficiency photon detectors. Output from the detectors is sent to a high resolution time tagger, where coincidences between the entangled photons are recorded. By varying the length of the long path in one Mach-Zehnder interferometer, it is possible to observe high visibility sinusoidal fringes in the measured coincidence rates (while no variation is seen in single photon detection rates). These fringes due to interference between the photon probability amplitudes are indicative of a violation of the Bell inequality, and confirm inconsistencies with local hidden variable theory for the correlations of the time-energy entangled photon pairs.

time-energy entanglement↗

Bell Inequality Experiment for a High Brightness Time-Energy Entangled Source

A periodically poled MgO - doped LiNbO3 (MgO:LN) non-degenerate photon pair source is utilized for spontaneous parametric down-conversion of 532-nanometer photons into time-energy entangled pairs of 800- and 1600-nanometer photons. The entangled photons are separated using previously detailed sorting optics, such that each wavelength is independently directed through one of two modified Mach-Zehnder interferometers - also known as a Franson interferometer - after which they are fiber-optically guided to high-efficiency photon detectors. Output from the detectors is sent to a high resolution time tagger, where coincidences between the entangled photons are recorded. By varying the length of the long path in one Mach-Zehnder interferometer, it is possible to observe high visibility sinusoidal fringes in the measured coincidence rates (while no variation is seen in single photon detection rates). These fringes - due to interference between the photon probability amplitudes - are indicative of a violation of the Bell inequality, and confirm inconsistencies with local hidden variable theory for the correlations of the time-energy entangled photon pairs.

Time-Energy Entanglement↗

Mass Gauging Demonstrator for Any Gravitational Conditions

The present invention is a mass gauging interferometry system used to determine the volume contained within a tank. By using an optical interferometric technique to determine gas density and/or pressure a much smaller compression volume or higher fidelity measurement is possible. The mass gauging interferometer system is comprised of an optical source, a component that splits the optical source into a plurality of beams, a component that recombines the split beams, an optical cell operatively coupled to a tank, a detector for detecting fringes, and a means for compression. A portion of the beam travels through the optical cell operatively coupled to the tank, while the other beam(s) is a reference.

Korman, Valentin↗