Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “neutron detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Neutron Star Spin Measurements and Dense Matter with LOFT

Observations over the last decade with RXTE have begun to reveal the X-ray binary progenitors of the fastest spinning neutron stars presently known. Detection and study of the spin rates of binary neutron stars has important implications for constraining the nature of dense matter present in neutron star interiors, as both the maximum spin rate and mass for neutron stars is set by the equation of state. Precision pulse timing of accreting neutron star binaries can enable mass constraints. Particularly promIsing is the combination of the pulse and eclipse timing, as for example, in systems like Swift 11749.4-2807. With its greater sensitivity, LOFT will enable deeper searches for the spin periods of the neutron stars, both during persistent outburst intervals and thermonuclear X-ray bursts, and enable more precise modeling of detected pulsations. I will explore the anticipated impact of LOFT on spin measurements and its potential for constraining dense matter in neutron stars

Strohmayer, Tod↗

What Is the Limit of Quantification for the Minor Phase in Time-of-Flight Neutron Diffraction? A Case Study on Fe and Ni Powder Mixtures at VULCAN

A phase present in small quantities within materials may not simply serve as a secondary component; it can play a crucial role in determining the integrity, properties, and performance of the material. These minor but important phases usually draw attention in material design and processing for fundamental understanding as well as material quality control. Accurately quantifying a minor phase amid a majority phase, especially at extremely low fractions, remains a challenging task. Time-of-flight neutron diffraction, coupled with advanced pattern analysis techniques like Rietveld refinement, is a powerful tool for crystal structure identification and phase quantification. The deep penetrating capability of neutrons enables the detection and quantification of trace phases within materials. In this study, the quantification limits of time-of-flight neutron diffraction were explored using the VULCAN diffractometer at the Spallation Neutron Source, using Fe–Ni powder mixtures as a sample system. By comparing the refinement results to the known weighed values, it was determined that the reliable quantification of a minor Ni phase is achievable down to about 0.1 wt% while a Ni fraction as low as 0.02 wt% is difficult to trace. Effective control of the refinement parameters, especially the profile function parameters, are found to significantly influence the convergence of fittings and the accuracy of phase quantification.

Rietveld refinement↗

Application of recoil-imaging time projection chambers to directional neutron background measurements in the SuperKEKB accelerator tunnel

Gaseous time projection chambers (TPCs) with high readout segmentation are capable of reconstructing detailed 3D ionization distributions of nuclear recoils resulting from elastic neutron scattering. Here, using a system of six compact TPCs with pixel ASIC readout, filled with a 70:30 mixture of He:CO 2 gas, we analyze the first directional measurements of beam-induced neutron backgrounds in the tunnel regions surrounding the Belle II detector at the SuperKEKB e + e – collider. With the use of 3D recoil tracking, we show that these TPCs are capable of maintaining nearly 100% nuclear recoil purity to reconstructed ionization energies (E reco ) as low as 5 keV ee . Using a large sample of Monte-Carlo (MC)-simulated 4 He, 12 C, and 16 O recoil tracks, we find consistency between predicted and measured recoil energy spectra in five of the six TPCs, providing useful validation of the neutron production mechanisms modeled in simulation. Restricting this sample to 4 He recoil tracks with E reco > 40 keV ee , we further demonstrate axial angular resolutions within 8° and we introduce a procedure that under suitable conditions, correctly assigns the vector direction to 91% of these simulated 4 He recoils. Applying this procedure to assign vector directions to measured 4 He recoil tracks, we observe consistency between the angular distributions of observed and simulated recoils, providing first experimental evidence of localized neutron “hotspots” in the accelerator tunnel. Observed rates of nuclear recoils in these TPCs suggest that simulation overestimates the neutron flux from these hotspots. Despite this, we estimate these hotspots to produce the majority of neutron backgrounds in the accelerator tunnel at SuperKEKB’s target luminosity of 6.3 x 10 35 cm –2 s –1 , making them important regions to continue to monitor.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Error quantification and comparison of binary neutron star gravitational waveforms from numerical relativity codes

Future gravitational wave detections of merging binary neutron star systems have the possibility to tightly constrain the equation of state of dense nuclear matter. In order to extract such constraints, gravitational waveform models need to be calibrated to accurate numerical relativity simulations of the late inspiral and merger. In this work, we take an essential step toward classifying the error and potential systematics in current generation numerical relativity simulations of merging binary neutron stars. To this end, we perform a direct comparison of two codes (fil, spec), which differ in many aspects, including the numerical methods and discretizations used and equations solved. We find that despite these different approaches, the codes are—within current numerical resolution bounds—fully consistent, and broadly comparable in cost for a given accuracy level. Our results indicate that the error in the waveforms is primarily dominated by the hydrodynamic evolution, consistent with earlier findings in the literature. Finally, we also discuss current limitations and cost estimates for numerical relativity simulations to reach the accuracies required in the era of next-generation gravitational detectors.

gravitational waves↗

Constraining the Dense Matter Equation of State with New NICER Mass–Radius Measurements and New Chiral Effective Field Theory Inputs

Pulse profile modeling of X-ray data from the Neutron Star Interior Composition Explorer is now enabling precision inference of neutron star mass and radius. Combined with nuclear physics constraints from chiral effective field theory (χEFT), and masses and tidal deformabilities inferred from gravitational-wave detections of binary neutron star mergers, this has led to a steady improvement in our understanding of the dense matter equation of state (EOS). Here, we consider the impact of several new results: the radius measurement for the 1.42 M ⊙ pulsar PSR J0437−4715 presented by Choudhury et al., updates to the masses and radii of PSR J0740+6620 and PSR J0030+0451, and new χEFT results for neutron star matter up to 1.5 times nuclear saturation density. Using two different high-density EOS extensions—a piecewise-polytropic (PP) model and a model based on the speed of sound in a neutron star (CS)—we find the radius of a 1.4 M ⊙ (2.0 M ⊙ ) neutron star to be constrained to the 95% credible ranges ${12.28}_{-0.76}^{+0.50}$ km (${12.33}_{-1.34}^{+0.70}$ km) for the PP model and ${12.01}_{-0.75}^{+0.56}$ km (${11.55}_{-1.09}^{+0.94}$ km) for the CS model. The maximum neutron star mass is predicted to be ${2.15}_{-0.16}^{+0.14}$M ⊙ and ${2.08}_{-0.16}^{+0.28}$M ⊙ for the PP and CS models, respectively. We explore the sensitivity of our results to different orders and different densities up to which χEFT is used, and show how the astrophysical observations provide constraints for the pressure at intermediate densities. Moreover, we investigate the difference R 2.0 − R 1.4 of the radius of 2 M ⊙ and 1.4 M ⊙ neutron stars within our EOS inference.

gravitational wave sources↗

Radiation portal monitor data file format for comprehensive background radiation monitoring

Radiation portal monitors (RPMs) are widely used at border security checkpoints to detect the presence of radioactive materials in people, vehicles, and cargo. Typically, RPM detection systems consist of two pillars equipped with gamma and neutron detectors. To improve detection efficiency, RPMs employ techniques such as a limited energy window, dynamic alarm thresholds, and lead shielding. However, without continuous monitoring of background radiation, signal interpretation can be compromised, because environmental factors and mechanical failures can cause fluctuations. Here, we introduce a daily file format that logs gamma background and neutron background radiation levels continuously over a 24 h period; this format is different from traditional formats that record data only when the RPM is active or occupied. The approach enables RPM operators and analysts to (1) identify and diagnose malfunctioning components, (2) adjust system settings to account for dynamic environmental factors, and (3) use the recorded data to characterize outer space phenomena. Continuous background reporting is essential for identifying issues such as faulty connections, voltage divider failures, and errors in background updates. Continuous background reporting also enables the detection of external influences, including nearby X-ray scanners, temperature fluctuations, rainfall, cosmic radiation, and lunar phase changes. These data files are designed to be easily evaluated and parsed using common tools, and a quick review by an expert is often sufficient for problem diagnosis. We anticipate that continuous background radiation monitoring and these new strategies will significantly improve the accuracy and reliability of RPM systems, reducing the rate of false alarms and enhancing overall system performance.

Background radiation monitoring↗

Nematic fluctuations in iron-oxychalcogenide Mott insulators

Nematic fluctuations occur in a wide range physical systems from biological molecules to cuprates and iron pnictide high- T c superconductors. It is unclear whether nematicity in pnictides arises from electronic spin or orbital degrees of freedom. We studied the iron-based Mott insulators La 2 O 2 Fe 2 OM 2 M = (S, Se), which are structurally similar to pnictides. Nuclear magnetic resonance revealed a critical slowing down of nematic fluctuations and complementary Mössbauerr spectroscopy data showed a change of electrical field gradient. The neutron pair distribution function technique detected local C 2 fluctuations while neutron diffraction indicates that global C 4 symmetry is preserved. A geometrically frustrated Heisenberg model with biquadratic and single-ion anisotropic terms provides the interpretation of the low temperature magnetic fluctuations. The nematicity is not due to spontaneous orbital order, instead it is linked to geometrically frustrated magnetism based on orbital selectivity. This study highlights the interplay between orbital order and spin fluctuations in nematicity.

36 MATERIALS SCIENCE↗

NDX: Neutron Dose Rate Meters with Extended Capabilities

Particle accelerators, irradiation facilities, and nuclear power plants would benefit from using neutron dose rate meters featuring improved energy response covering full range of expected neutron energies, improved dynamic range of measured dose rates while providing the real-time data, and improved ability to operate in harsh radiation environments including heavy photon backgrounds and pulsed beams. The novel design of the neutron moderator for the NDX dose rate meter implements a layer of a Beryllium-loaded medium Z material which, similar to the earlier known WENDI detectors, allows the device to detect higher energy neutron flux and convert it to dose. Using Beryllium helps to fill the known dip in the response functions around 5-50 MeV. Optimized design parameter set, obtained using FLUKA Monte Carlo simulations, features the NDX moderator made of polyethylene embedding a layer of BeCu alloy inside, with the dose rate response constant within ±10% in the neutron energy range from about 100 keV to 500 MeV, and ±25% essentially in the full energy range above thermal. A new sensor technique implemented in the NDX is based on using the Ionization Chamber (IC) filled with 3He gas to capture the moderated neutron fluence, and includes a symmetric IC filled with regular 4He to evaluate the contributions due to the non-neutron ionizing radiation. Advantages of the method include large accessible dynamic range, relative insensitivity of the IC probes to photon radiation fields, and the ability to subtract their contribution. Two prototype NDX detectors were built, calibrated, and operated in various conditions at the CEBAF 12 GeV electron accelerator at JLab. The first results showed reliable neutron dose rate measurements in the presence of overwhelming photon radiation fields, and at practical high dose rate levels of up to approximately 10 Sv/h. Detector design, operation, first results, and further development plans are presented.

Degtiarenko, Pavel V.↗

Risk analysis: divergent models and convergent interpretations

Material presented at a NASA-sponsored workshop on risk models for exposure conditions relevant to prolonged space flight are described in this paper. Analyses used mortality data from experiments conducted at Argonne National Laboratory on the long-term effects of external whole-body irradiation on B6CF1 mice by 60Co gamma rays and fission neutrons delivered as a single exposure or protracted over either 24 or 60 once-weekly exposures. The maximum dose considered was restricted to 1 Gy for neutrons and 10 Gy for gamma rays. Proportional hazard models were used to investigate the shape of the dose response at these lower doses for deaths caused by solid-tissue tumors and tumors of either connective or epithelial tissue origin. For protracted exposures, a significant mortality effect was detected at a neutron dose of 14 cGy and a gamma-ray dose of 3 Gy. For single exposures, radiation-induced mortality for neutrons also occurred within the range of 10-20 cGy, but dropped to 86 cGy for gamma rays. Plots of risk relative to control estimated for each observed dose gave a visual impression of nonlinearity for both neutrons and gamma rays. At least for solid-tissue tumors, male and female mortality was nearly identical for gamma-ray exposures, but mortality risks for females were higher than for males for neutron exposures. As expected, protracting the gamma-ray dose reduced mortality risks. Although curvature consistent with that observed visually could be detected by a model parameterized to detect curvature, a relative risk term containing only a simple term for total dose was usually sufficient to describe the dose response. Although detectable mortality for the three pathology end points considered typically occurred at the same level of dose, the highest risks were almost always associated with deaths caused by tumors of epithelial tissue origin.

Non-NASA Center↗

Neutron and high speed photogrammetric arcjet diagnosis

Two methods for real time internal diagnostics of arcjet engines are described. One method uses cold, thermal, or epithermal neutrons. Cold neutrons are used to detect the presence and location of hydrogenous propellants. Thermal neutrons are used to delineate the edge contours of anode and cathode surfaces and to measure stress/strain. Epithermal neutrons are used to measure temperatures on arcjet surfaces, bulk material temperatures, and point temperatures in bulk materials. It is found that this method, with an exposure time of 10 min, produces at temperature accuracy for W or Re of + or - 2.5 C. The other method uses visible-light high-speed photogrammetry to obtain images of the transient behavior of the arc during start-up and to relate this behavior to electrial supply characteristics such as voltage, current, and ripple.

Stewart, P. A. E.↗

Demonstration of the neutron tracking capability of NEXT array in time-of-flight measurements to improve energy resolution

Precise neutron-energy measurements are required to probe the nuclear structure effects of neutron-rich nuclei, where β-delayed neutron emission becomes a dominant decay mode. The Neutron dEtector with Xn Tracking (NEXT) array has been designed and constructed to measure β-delayed neutrons with better energy resolution. The new design localizes the neutron interaction position by optically segmenting the detector along the direction of the neutron flight path, reducing the associated uncertainties in the neutron time-of-flight measurements. This significantly improves the energy resolution without losing the necessary detection efficiency. The proof-of-principle and efficiency measurements showed promising results. Herein, this article details the implementation of the neutron tracking capability of NEXT array in time-of-flight measurements.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Applications of HPGe-detected high energy gamma rays toward quantifying neutron emission rates and 234 U enrichment in UF 6 cylinders

This study presents a 234 U enrichment meter that uses high energy gamma and neutron count rate as measured by a portable, high-purity germanium gamma ray detector. Twenty-one 30B cylinders containing UF 6 of varying origin were analyzed with an HPGe detector for high-energy gamma ray and neutron counts. Excellent correlations (R 2 0.95) between various regions of 3.0 MeV gamma rays, neutron count rate, and uranium enrichment were found. These neutron and high-energy gamma data are used to create calibration-dependent enrichment meters for 234 U. The 234 U enrichment calculated from the neutron count rate and 4 – 6 MeV gamma count rate is more accurate than methods that rely on the 120.9 keV peak which is strongly attenuated inside commercial sized UF 6 cylinders. These neutron and high-energy gamma enrichment calculators can also be used to determine a 235 U enrichment, assuming mass-based enrichment from natural uranium, but the results are not as accurate as the traditional 185.7 keV peak enrichment meter.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Status of h-BN quasi-bulk crystals and high efficiency neutron detectors

III-nitrides have fomented a revolution in the lighting industry and are poised to make a huge impact in the field of power electronics. In the III-nitride family, the crystal growth and use of hexagonal BN (h-BN) as an ultrawide bandgap (UWBG) semiconductor are much less developed. Bulk crystals of h-BN produced by the high-temperature/high-pressure and the metal flux solution methods possess very high crystalline and optical qualities but are impractical to serve as substrates or for device implementation as their sizes are typically in millimeters. The development of crystal growth technologies for producing thick epitaxial films (or quasi-bulk or semi-bulk crystals) in large wafer sizes with high crystalline quality is a prerequisite for utilizing h-BN as an UWBG electronic material. Compared to traditional III-nitrides, BN has another unique application as solid-state neutron detectors, which however, also require the development of quasi-bulk crystals to provide high detection efficiencies because the theoretical efficiency (ηi) relates to the detector thickness (d) by ηi=1−e−dλ, where λ denotes the thermal neutron absorption length which is 47 μm (237 μm) for 10B-enriched (natural) h-BN. We provide an overview and recent progress toward the development of h-BN quasi-bulk crystals via hydride vapor phase epitaxy (HVPE) growth and the attainment of thermal neutron detectors based on 100 μm thick 10B-enriched h-BN with a record efficiency of 60%. The thermal neutron detection efficiency was shown to enhance at elevated temperatures. Benchmarking the crystalline and optical qualities of h-BN quasi-bulk crystals with the state-of-the-art mm-sized bulk crystal flakes and 0.5 μm thick epitaxial films identified that reducing the density of native defects such as vacancies remains the most critical task for h-BN quasi-bulk crystal growth by HVPE.

Physics↗

Steam-Assisted Ammonolysis of MoO2 as a Synthetic Pathway to Oxygenated δ-MoN

A common route for the synthesis of molybdenum nitrides is through the temperature-programmed reaction of molybdenum oxides with NH3, or ammonolysis. In this work, the role of precursor phase, gas phase chemistry (impact of H2O), and temperature profile on the reaction outcome (700 °C) was examined, which resulted in varying amounts of MoO2, H2MoO5, and the nitride phases—cubic γ (nominally Mo2N) and hexagonal δ (nominally MoN). The phase fraction of the δ phase increased with precursor in the sequence MoO2 > MoO3 > H2MoO5. Steam in the reaction gas also favored the production of δ over γ, but with too much steam, MoO2 was obtained in the product. Synthesis conditions for obtaining nearly phase-pure δ were identified: MoO2 as the precursor, 2% H2O in the gas stream, and a moderate heating rate (3 °C/min). In situ X-ray diffraction provided insights into the reaction pathway. Extensive physico-chemical analysis of the δ phase, including synchrotron X-ray and neutron diffraction, electron microscopy, thermogravimetric analysis, X-ray photoelectron spectroscopy, and prompt gamma activation analysis, revealed its stoichiometry to be MoO0.108(8)N0.892(8)H0.012(5), indicating non-trivial oxygen incorporation. The presence of N/O ordering and an impurity phase Mo5N6 were also revealed, detectable only by neutron diffraction. Notably, a computationally predicted MoON phase (doi: 10.1103/PhysRevLett.123.236402), of interest due to its potential to display a metal-insulator transition, did not appear under any reaction condition examined.

Pandey, Shobhit↗

Using the HHT to Search for Gravitational Waves

Gravitational waves are a consequence of Einstein's theory of general relativity applied to the motion of very dense and massive objects such as black holes and neutron stars. Their detection will reveal a wealth of information about these mysterious objects that cannot be obtained with electromagnetic probes. Two projects are underway to attempt the detection of gravitational waves: NASA's Laser Interferometer Space Antenna (LISA), a space based mission being designed to search for waves from supermassive black holes at the centers of galaxies, and the NSF's Laser Interferometer Gravitational Wave Observatory (LIGO), a ground based facility that is now searching for waves from supernovae. pulsars, and the coalescence of black hole and neutron star systems. Because general relativity is an inherently non-linear theory, many of the predicted source waveforms show strong frequency modulation. In addition, the LIGO and LISA detectors are highly sensitive devices that produce a variety of non-linear transient noise features. Thus the unique capabilities of the HHT. the extraction of intrawave modulation and the characterization of non-linear and non-stationary signals, have a natural application to both signal detection and experimental characterization of the detectors. In this talk I will give an overview of the status of the field. including some of the expected sources of gravitational waves, and I will also describe the LISA and LIGO detectors. Then I will describe some applications of the HHT to waveform detection and detector noise characterization.

Camp, Jordan↗

Measurement of the cross section of the Q=4.4398 MeV 12 C (n, n'γ) reaction from threshold to 16.5 MeV using γ and correlated n–γ detection

The Q=4.4398 MeV 12 C (n, n'γ) cross section was measured using a white incident neutron source through the detection of γ rays only and n–γ coincidences using a segmented liquid scintillator detector array. While the n–γ technique utilized here is more generally applicable to a wide variety of neutron scattering measurements, the γ-only technique was successfully applied to this reaction to exploit the precise time resolution and high efficiency of this detection system to yield results with unprecedented statistical precision and total uncertainties < 2 % from reaction threshold up to 16 MeV incident neutron energy, clearly resolving many features in this reaction that were previously not well known. The γ-only and n–γ results are consistent with each other for the majority of the incident energy range covered in this paper, thereby lending validation to the n–γ technique for future measurements, though significant disagreements are observed between both results and with the ENDF/B-VIII.0 nuclear data evaluation. These differences are particularly noticeable in the recently evaluated energy range below 6.5 MeV, and also near 14 MeV where a “sawtooth”-like feature is observed similar to that in other 12 C+n reaction channels. Finally, both γ-only and n–γ results are presented here with thorough covariance derivations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Comparison of Approach-to-Critical Results in Current and Pulse Mode for Systems with High Starter Neutron Rates

Reactors and critical assemblies use a variety of detection systems to monitor the neutron population. The count rate is proportional to the neutron flux present at the location of the detector. When such systems are placed external to an assembly, it is often assumed that the relative leakage multiplication will be proportional to the detector count rate (assuming that the source term, system geometry, and detector placement have not changed). Such systems are often used in an approach-to-critical during reactor startup to ensure that the critical configuration is well predicted. Various types of detectors have been used during an approach-to-critical. These include 3 He, BF 3 , ion chambers, fission chambers, and fission foils. Any of these types of systems (or others) should work well when adequate counting statistics are available. These detector systems can be operated in either pulse or current mode. The National Criticality Experiments Research Center (NCERC) has two detection systems that are commonly used in critical assembly operations. The start-up (referred to as "SU" in this work) system is made up of 3 He proportional counters in pulse mode and the linear counter system (referred to as "LC" in this work) consists of compensated ion-chambers in current mode. Typically the SU system is used for approach-to-critical operations and the LC system is only used at/above delayed critical ( k eff = 1). This work investigates the use of the LC system for an approach-to-critical. It has been long hypothesized that such an approach would be feasible for systems with high starter neutron rates.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Where are the r-modes? Chandra Observations of Millisecond Pulsars

We present the results of Chandra observations of two non-accreting millisecond pulsars, PSRs J1640+2224(J1640) and J1709+2313 (J1709), with low inferred magnetic fields and spin-down rates in order to constrain their surface temperatures, obtain limits on the amplitude of unstable r-modes in them, and make comparisons with similar limits obtained for a sample of accreting low-mass X-ray binary (LMXB) neutron stars. We detect both pulsars in the X-ray band for the first time. They are faint, with inferred soft X-ray fluxes(0.3-3 keV) of approx. 6 x 10(exp -15) and 3 x 10( exp -15) erg/sq cm for J1640 and J1709, respectively. Spectral analysis assuming hydrogen atmosphere emission gives global effective temperature upper limits (90% confidence) of 3.3-4.3 x 10(exp 5) K for J1640 and 3.6-4.7 x 10(exp 5) K for J1709, where the low end of the range corresponds to canonical neutron stars (M = 1.4 Stellar Mass), and the upper end corresponds to higher-mass stars (M = 2.21 Stellar Mass). Under the assumption that r-mode heating provides the thermal support, we obtain dimensionless r-mode amplitude upper limits of 3.2-4.8 x 10(exp -8) and 1.8-2.8 x 10(exp -7) for J1640 and J1709, respectively, where again the low end of the range corresponds to lower-mass, canonical neutron stars (M =1.4 Stellar Mass). These limits are about an order of magnitude lower than those we derived previously for a sample of LMXBs, except for the accreting millisecond X-ray pulsar SAX J1808.43658, which has a comparable amplitude limit to J1640 and J1709.

oscillations↗