Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “motion”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Motion of the Mantle in the Translational Modes of the Earth and Mercury

Slichter modes refer to the translational motion of the inner core with respect to the outer core and the mantle. The polar Slichter mode is the motion of the inner core along the axis of rotation. Busse presented an analysis of the polar mode which yielded an expression for its period. Busse's analysis included the assumption that the mantle was stationary. This approximation is valid for planets with small inner cores, such as the Earth whose inner core is about 1/60 of the total planet mass. On the other hand, many believe that Mercury's core may be enormous. If so, the motion of the mantle should be expected to produce a significant effect. We present a formal framework for including the motion of the mantle in the analysis of the translational motion of the inner core. We analyze the effect of the motion of the mantle on the Slichter modes for a non-rotating planet with an inner core of arbitrary size. We omit the effects of viscosity in the outer core, magnetic effects, and solid tides. Our approach is perturbative and is based on a linearization of Euler's equations for the motion of the fluid and Newton's second law for the motion of the inner core. We find an analytical expression for the period of the Slichter mode. Our result agrees with Busse's in the limiting case of small inner core. We present the unexpected result that even for Mercury the motion of the mantle does not significantly change the period of oscillation.

Grinfeld, Pavel↗

Software Tools for Developing and Simulating the NASA LaRC CMF Motion Base

The NASA Langley Research Center (LaRC) Cockpit Motion Facility (CMF) motion base has provided many design and analysis challenges. In the process of addressing these challenges, a comprehensive suite of software tools was developed. The software tools development began with a detailed MATLAB/Simulink model of the motion base which was used primarily for safety loads prediction, design of the closed loop compensator and development of the motion base safety systems1. A Simulink model of the digital control law, from which a portion of the embedded code is directly generated, was later added to this model to form a closed loop system model. Concurrently, software that runs on a PC was created to display and record motion base parameters. It includes a user interface for controlling time history displays, strip chart displays, data storage, and initializing of function generators used during motion base testing. Finally, a software tool was developed for kinematic analysis and prediction of mechanical clearances for the motion system. These tools work together in an integrated package to support normal operations of the motion base, simulate the end to end operation of the motion base system providing facilities for software-in-the-loop testing, mechanical geometry and sensor data visualizations, and function generator setup and evaluation.

Bryant, Richard B., Jr.↗

Algorithm for Simulating Atmospheric Turbulence and Aeroelastic Effects on Simulator Motion Systems

Atmospheric turbulence produces high frequency accelerations in aircraft, typically greater than the response to pilot input. Motion system equipped flight simulators must present cues representative of the aircraft response to turbulence in order to maintain the integrity of the simulation. Currently, turbulence motion cueing produced by flight simulator motion systems has been less than satisfactory because the turbulence profiles have been attenuated by the motion cueing algorithms. This report presents a new turbulence motion cueing algorithm, referred to as the augmented turbulence channel. Like the previous turbulence algorithms, the output of the channel only augments the vertical degree of freedom of motion. This algorithm employs a parallel aircraft model and an optional high bandwidth cueing filter. Simulation of aeroelastic effects is also an area where frequency content must be preserved by the cueing algorithm. The current aeroelastic implementation uses a similar secondary channel that supplements the primary motion cue. Two studies were conducted using the NASA Langley Visual Motion Simulator and Cockpit Motion Facility to evaluate the effect of the turbulence channel and aeroelastic model on pilot control input. Results indicate that the pilot is better correlated with the aircraft response, when the augmented channel is in place.

Ercole, Anthony V.↗

Verification of a Motion Cueing Strategy for Stall Recovery Training in a Commercial Transport Simulator

This presentation verifies a motion cueing strategy for improved pilot stall recovery training in commercial transport simulators. Eight airline transport pilots flew a high-altitude stall recovery task in the NASA B747 level-D-certified full flight simulator under three different motion configurations: no motion, baseline motion, and enhanced motion. For each motion condition, pilots performed the task with both baseline aircraft dynamics and aircraft dynamics enhanced with lateral-directional characteristics of the airplane at angle of attack approaching stall. Motion configuration significantly affected: 1) pilot opinions on the helpfulness of motion in performing the task, 2) the maximum roll angle in the stall maneuver, 3) the minimum load factor in the recovery, 4) the number of secondary stick shakers in the stall recovery, and 5) the maximum airspeed in the recovery. The two different aircraft dynamics significantly affected: 1) pilot opinions on the noticeability of the banking roll off near the stall and 2) the maximum roll angle in the stall maneuver. These results indicate that the relatively minor enhancements to the motion logic of heritage commercial transport simulators presented here can significantly improve pilot performance in simulated stall recoveries, and potentially improve stall recovery training.

Zaal, Petrus M. T.↗

The Influence of Frequency and Duration Of Seismic Ground Motion On The Size Of Triggered Landslides—A Regional View

Observation, theory, and intuition all suggest that larger earthquakes should trigger larger landslides. Many factors could contribute to this, including depth-dependent shear strength or non-linearity of ground motion in soils and rock, but we hypothesize that the key characteristics of large earthquakes causing this phenomenon are (in addition to magnitude) the frequency and duration of the strong ground motion. Because of the paucity of site-specific data for detailed analysis, we take a regional approach to this question by analyzing strong-motion records and earthquake-induced landslide (EQIL) inventories from six well-documented earthquakes. Ground motion is characterized using earthquake magnitude and the median durations and frequencies (mean periods) of subsets of strong-motion records relevant to landslide triggering. EQIL inventories are characterized using the median landslide area of the entire inventory as well as the median areas of the largest 1% of the landslides and the largest 10 landslides. We then compare ground-motion characteristics with landslide size statistics to determine possible correlations. Comparisons of all earthquake- and landslide-size statistics show strong positive correlations between landslide size and (1) magnitude, (2) ground-motion duration, and (3) mean period. Although all the ground-motion measures yield highly correlated regressions, mean period appears to be the best overall predictor of landslide size. Landslide modeling using Newmark's sliding-block method also shows that longer mean periods and durations and larger magnitudes correlate strongly with increases in modeled displacements. These results support our hypothesis that increasing period and duration of seismic ground motion are the physical factors driving increased landslide sizes for larger earthquakes. Additional studies including data from a much larger set of earthquakes is needed to confirm the results of this initial study.

Hakan Tanyas↗

Accuracy of Center of Pressure Determination via Motion Capture

BACKGROUND: This study was conducted to support the stability assessment for tasks in lunar gravity and exercises on a Vibration Isolation and Stabilization (VIS) system in microgravity based on the dynamic feasibility criterion of whether the calculated position of the center of pressure (COP) falls within the base of support (BOS) which outlines the subject’s feet. Motion capture data combined with biomechanical modeling and simulation allows the forces and moments between the human and the VIS platform to be computed and the position of the COP as well as the location and shape of the BOS to be determined. The goal of this study was to assess the accuracy of the COP trajectory calculated using motion capture-based data. METHODS AND RESULTS: To obtain the dynamic quantities from which COP is calculated, motion capture data is first collected in the 1g lab environment by recording the trajectories of passive retroreflective markers placed on a subject during exercise or performance of a given task. The OpenSim [1] inverse kinematics (IK) tool is used to fit a scaled subject model to recorded marker trajectories while minimizing marker error to obtain joint angles. Then, a custom OpenSim plugin [2] is used to determine the subject’s time-varying moment of inertia and its time derivative, center of mass (CM) position, velocity, and acceleration, as well as the angular momentum and its time derivative relative to the subject’s CM. Some of these quantities are not needed for modeling tasks performed on a stationary lunar surface but, due to the moving exercise platform, are needed to model VIS response to the subject’s motion. Hand positions, used in calculating a cable force if present, are recorded as well. These quantities are used to calculate the total force (F ⃗^((plate) )) and moment (M ⃗^((plate) )) exerted by the lunar surface or the VIS plate on the subject’s shoe soles. COP is then calculated from the following equations: r_x^((cop) )= M_z^((plate) )/F_y^((plate) ) and r_z^((cop) )= 〖-M〗_x^((plate) )/F_y^((plate) ), where the y axis is normal to the surface. COP accuracy for feasibility assessments is then determined by whether it falls within the BOS, which is also computed by the plugin. To study the accuracy of COP calculated from motion capture, we first investigated whether COP remained within the BOS, as it must, for exercises performed in the 1g lab environment. Standard exercises such as back squat and deadlift were analyzed, as well as more explosive exercises including hang clean and press. Cases in which the COP exited the BOS indicated that COP accuracy required further investigation. In this study, an exercise device with cables was used, so cable force modeling accuracy should also be considered. In a separate study, we collected motion capture and force plate data for twenty-seven motions not involving an exercise device. About a third were genuine countermeasures exercises (e.g., hang clean and press), some were relevant for lunar tasks (e.g., object pick up), and the rest were of a “unit test” nature (e.g., swaying back and forth or side to side). Motion capture-based COP positions were compared with force plate measured COP. We found that while force plate measured COP remained within the BOS, motion capture-based COP was observed to briefly exit the BOS on occasion. Techniques to mitigate IK artifacts and filtering of calculated data could be used to improve the agreement of calculated and measured results, resolving excursions from the BOS within this dataset. The mean error between calculated and measured COP was found to be less than 6 mm. Additionally, we derived and investigated equations for the COP in terms of the cable force, cable location, as well as the human CM position, acceleration, and angular momentum with respect to the CM, and analyzed them for sensitivity to errors in individual quantities. Several were found, but the most significant one was that when the vertical force on the feet approaches zero, indicating a near-detachment or ‘jump off’ condition, errors are amplified. This is consistent with the observation that in the absence of pressure, the concept of the center of pressure would become meaningless.

C A Bell↗

Evaluation of Markerless Motion Capture for Monitoring Sensorimotor Performance

BACKGROUND Astronauts returning from long-duration exposure to microgravity frequently exhibit alterations in sensorimotor function leading to postural imbalance, impaired locomotion, and operational challenges to manual control. Mission duration and individual responses often influence both the severity of performance decrements and the variability in adaptation timelines. Postflight disruptions during functional tasks are often detected through body-worn inertial measurement unit (IMU) devices. While IMU sensors are relatively compact, the long-term wear may lead to discomfort, displacement of the sensors on the body, and restrictions in movement or crew behavior. Although IMU data offers valuable insights from a research standpoint, interpreting changes in pre- and post-flight measures can be difficult for crew support personnel beyond the research domain, which can hinder the application for medical assessments and rehabilitation. Finally, the availability of inertial sensors in-flight is limited. There is a need for unobtrusive monitoring tools to improve our ability to monitor adaptation following gravitational transitions in various postflight evaluations and rehabilitation settings. Markerless motion capture (MMC) is an evolving unobtrusive technology that builds upon decades of research with marker-based motion capture systems to provide 3D human pose estimation from multiple synchronized 2D camera views using deep learning algorithms. Markerless technology can revolutionize how data is captured pre- and post-flight and potentially in-flight during intravehicular activity by enabling pose estimation of multiple crew members from onboard camera hardware. METHODS The following presents the initial evaluation of a state-of-the-art commercial-off-the-shelf MMC system, Theia Markerless, compared to IMU devices during various ground-based functional tasks and environmental conditions. The featured functional tasks include assessments from Human Research Program (HRP) funded studies such as Sensorimotor Standard Measures and Sensorimotor Assessments. Synchronous data collected using both motion capture and IMUs are analyzed for six male and female subjects of varying anthropometry. The analysis includes limited assessments of clothing, capture volume configurations, and the tool's sensitivity to detecting performance changes after a spaceflight analog centrifuge exposure. The development of visualization tools to enhance the application of the pose estimation output is also presented. RESULTS Initial results demonstrate comparable root mean square error (RMSE) to existing literature evaluating markerless and marker-based motion capture systems. Considering the relative functional range of motion of the cervical spine, normalized error values for the markerless system’s accuracy of the head was 0.032 in pitch, 0.025 in roll, and 0.018 in yaw plane of motion across a subset of functional tasks. The raw RMSE values were 3.49, 2.25, and 2.81 degrees respectively. For the torso, results suggest normalized errors of 0.469 in pitch, 0.191 in roll, and 0.307 in yaw planes of motion and raw RMSE values of 3.52, 1.53, and 3.07 degrees respectively. The data suggests the functional demands of a particular task influences the estimation accuracy of the MMC system where more dynamic motion and cases where subjects are not upright may introduce diminished tracking accuracy. DISCUSSION The following work lays the foundation for future implementations leveraging markerless motion capture to assess the time course of recovery and provide insight for rehabilitation protocols to enhance crew readiness for the resumption of daily activities. These tools offer effective methods for anonymizing sensitive crew data, facilitating numerous applications across research, medical, and rehabilitation groups. Collaborations with the Anthropometry and Biomechanics Facility will provide further comparisons of the Markerless system to a marker-based system. ACKNOWLEDGEMENT</ This work is supported by NASA’s Exploration Systems Development Mission Directorate Mars Campaign Office Crew Health Countermeasures.

Hannah M. Weiss↗

Liquid-like and rigid-body motions in molecular-dynamics simulations of a crystalline protein

To gain insight into crystalline protein dynamics, we performed molecular-dynamics (MD) simulations of a periodic 2 × 2 × 2 supercell of staphylococcal nuclease. We used the resulting MD trajectories to simulate X-ray diffraction and to study collective motions. The agreement of simulated X-ray diffraction with the data is comparable to previous MD simulation studies. We studied collective motions by analyzing statistically the covariance of alpha-carbon position displacements. The covariance decreases exponentially with the distance between atoms, which is consistent with a liquidlike motions (LLM) model, in which the protein behaves like a soft material. To gain finer insight into the collective motions, we examined the covariance behavior within a protein molecule (intraprotein) and between different protein molecules (interprotein). The interprotein atom pairs, which dominate the overall statistics, exhibit LLM behavior; however, the intraprotein pairs exhibit behavior that is consistent with a superposition of LLM and rigid-body motions (RBM). Our results indicate that LLM behavior of global dynamics is present in MD simulations of a protein crystal. They also show that RBM behavior is detectable in the simulations but that it is subsumed by the LLM behavior. Finally, the results provide clues about how correlated motions of atom pairs both within and across proteins might manifest in diffraction data. Overall, our findings increase our understanding of the connection between molecular motions and diffraction data and therefore advance efforts to extract information about functionally important motions from crystallography experiments.

59 BASIC BIOLOGICAL SCIENCES↗

The relation of motion sickness to the spatial-temporal properties of velocity storage

Tilting the head in roll to or from the upright while rotating at a constant velocity (roll while rotating, RWR) alters the position of the semicircular canals relative to the axis of rotation. This produces vertical and horizontal nystagmus, disorientation, vertigo, and nausea. With recurrent exposure, subjects habituate and can make more head movements before experiencing overpowering motion sickness. We questioned whether promethazine lessened the vertigo or delayed the habituation, whether habituation of the vertigo was related to the central vestibular time constant, i.e., to the time constant of velocity storage, and whether the severity of the motion sickness was related to deviation of the axis of eye velocity from gravity. Sixteen subjects received promethazine and placebo in a double-blind, crossover study in two consecutive 4-day test series 1 month apart, termed series I and II. Horizontal and vertical eye movements were recorded with video-oculography while subjects performed roll head movements of approx. 45 degrees over 2 s to and from the upright position while being rotated at 138 degrees /s around a vertical axis. Motion sickness was scaled from 1 (no sickness) to an endpoint of 20, at which time the subject was too sick to continue or was about to vomit. Habituation was determined by the number of head movements that subjects made before reaching the maximum motion sickness score of 20. Head movements increased steadily in each session with repeated testing, and there was no difference between the number of head movements made by the promethazine and placebo groups. Horizontal and vertical angular vestibulo-ocular reflex (aVOR) time constants declined in each test, with the declines being closely correlated to the increase in the number of head movements. The strength of vertiginous sensation was associated with the amount of deviation of the axis of eye velocity from gravity; the larger the deviation of the eye velocity axis from gravity, the more severe the motion sickness. Thus, promethazine neither reduced the nausea associated with RWR, nor retarded or hastened habituation. The inverse relationship between the aVOR time constants and number of head movements to motion sickness, and the association of the severity of motion sickness with the extent, strength, and time of deviation of eye velocity from gravity supports the postulate that the spatiotemporal properties of velocity storage, which are processed between the nodulus and uvula of the vestibulocerebellum and the vestibular nuclei, are likely to represent the source of the conflict responsible for producing motion sickness.

NASA Discipline Neuroscience↗

Impact of the Earthquake Rupture on Ground-Motion Variability of the 24 August 2016 M w 6.2 Amatrice, Italy, Earthquake

Here, the devastating 24 August 2016 M w 6.2 earthquake that struck Amatrice, Italy, marked the beginning of a prolonged seismic sequence dominated by three subsequent M w ≥6.0 events in the central Apennines region. The earthquake destroyed Amatrice’s historic center, claiming the lives of 299 individuals and causing widespread damage in the neighboring villages. The severity of the ground shaking, with a recorded maximum acceleration of 850 cm/s 2 on the east–west component at the Amatrice station, was far greater than the predicted acceleration based on the Italian ground-motion model (GMM). As pointed out by several investigations, the observed ground-motion amplitude and its spatial variability during the earthquake can be linked to specific rupture characteristics, including slip distribution and rupture directivity effects revealed by the observed data (Tinti et al., 2016; Pischiutta et al., 2021). In this study, we conducted physics-based 3D numerical simulations of ground motion for the Amatrice earthquake for frequencies up to 3 Hz. We employed a series of kinematic rupture models and a well-constrained local 3D velocity model incorporating surface topography. The kinematic rupture realizations were generated using multiscale hybrid and fully stochastic models, following the technique proposed by Graves and Pitarka (2016). We focused on assessing the sensitivity of near-fault ground-motion amplitudes to earthquake rupture characteristics, in particular, the spatial slip pattern. To evaluate the quality of our simulations, we employed goodness-of-fit measurements performed in comparisons of simulated and recorded ground motions. The simulated ground motions compare well with the recorded data and predictions from GMMs for Italy, ITA18 (Lanzano et al., 2019). However, we found that the simulated interevent ground-motion variability (randomness in the source process) of peak ground velocity, σ (PGV) is higher than the constant σ (PGV) predicted by conventional GMMs. Our simulations using several rupture scenarios demonstrate that the near-fault ground-motion amplification pattern is directly related to the slip distribution pattern.

3D Ground Motions Simulations↗

Feasibility of Electromagnetic Transponder Use to Monitor Inter- and Intrafractional Motion in Locally Advanced Pancreatic Cancer Patients

Purpose: The primary objective of this study was to determine the feasibility of electromagnetic transponder implantation in patients with locally advanced unresectable pancreatic cancer. Secondarily, the use of transponders to monitor inter- and intrafractional motion, and the efficacy of breath holding for limiting target motion, were examined. Methods and Materials: During routine screening laparoscopy, 5 patients without metastatic disease were implanted with transponders peri-tumorally. The Calypso System's localization and tracking modes were used to monitor inter- and intrafractional motion, respectively. Intrafractional motion, with and without breath holding, was also examined using Calypso tracking mode. Results: Transponder implantation was well tolerated in all patients, with minimal migration, aside from 1 patient who expulsed a single transponder. Interfractional motion based on mean shifts from setup using tattoos/orthogonal imaging to transponder based localization from 164 treatments was significant in all dimensions. Mean shift (in millimeters), followed by the standard deviation and p value, were as follows: X-axis: 4.5 mm (1.0, p = 0.01); Y axis: 6.4 mm (1.9, p = 0.03); and Z-axis 3.9 mm (0.6, p = 0.002). Mean intrafractional motion was also found to be significant in all directions: superior, 7.2 mm (0.9, p = 0.01); inferior, 11.9 mm (0.9, p < 0.01); anterior: 4.9 mm (0.5, p = 0.01); posterior, 2.9 mm (0.5, p = 0.02); left, 2.2 mm (0.4, p = 0.02); and right, 3.1 mm (0.6, p = 0.04). Breath holding during treatment significantly decreased tumor motion in all directions. Conclusions: Electromagnetic transponder implantation appears to be safe and effective for monitoring inter- and intrafractional motion. Based on these results a larger clinical trial is underway.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Tumor Tracking Method Based on a Deformable 4D CT Breathing Motion Model Driven by an External Surface Surrogate

Purpose: To develop a tumor tracking method based on a surrogate-driven motion model, which provides noninvasive dynamic localization of extracranial targets for the compensation of respiration-induced intrafraction motion in high-precision radiation therapy. Methods and Materials: The proposed approach is based on a patient-specific breathing motion model, derived a priori from 4-dimensional planning computed tomography (CT) images. Model parameters (respiratory baseline, amplitude, and phase) are retrieved and updated at each treatment fraction according to in-room radiography acquisition and optical surface imaging. The baseline parameter is adapted to the interfraction variations obtained from the daily cone beam (CB) CT scan. The respiratory amplitude and phase are extracted from an external breathing surrogate, estimated from the displacement of the patient thoracoabdominal surface, acquired with a noninvasive surface imaging device. The developed method was tested on a database of 7 lung cancer patients, including the synchronized information on internal and external respiratory motion during a CBCT scan. Results: About 30 seconds of simultaneous acquisition of CBCT and optical surface images were analyzed for each patient. The tumor trajectories identified in CBCT projections were used as reference and compared with the target trajectories estimated from surface displacement with the a priori motion model. The resulting absolute differences between the reference and estimated tumor motion along the 2 image dimensions ranged between 0.7 and 2.4 mm; the measured phase shifts did not exceed 7% of the breathing cycle length. Conclusions: We investigated a tumor tracking method that integrates breathing motion information provided by the 4-dimensional planning CT with surface imaging at the time of treatment, representing an alternative approach to point-based external–internal correlation models. Although an in-room radiograph-based assessment of the reliability of the motion model is envisaged, the developed technique does not involve the estimation and continuous update of correlation parameters, thus requiring a less intense use of invasive imaging.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Magnetic Resonance Imaging–Guided versus Surrogate-Based Motion Tracking in Liver Radiation Therapy: A Prospective Comparative Study

Purpose: This study applied automatic feature detection on cine–magnetic resonance imaging (MRI) liver images in order to provide a prospective comparison between MRI-guided and surrogate-based tracking methods for motion-compensated liver radiation therapy. Methods and Materials: In a population of 30 subjects (5 volunteers plus 25 patients), 2 oblique sagittal slices were acquired across the liver at high temporal resolution. An algorithm based on scale invariant feature transform (SIFT) was used to extract and track multiple features throughout the image sequence. The position of abdominal markers was also measured directly from the image series, and the internal motion of each feature was quantified through multiparametric analysis. Surrogate-based tumor tracking with a state-of-the-art external/internal correlation model was simulated. The geometrical tracking error was measured, and its correlation with external motion parameters was also investigated. Finally, the potential gain in tracking accuracy relying on MRI guidance was quantified as a function of the maximum allowed tracking error. Results: An average of 45 features was extracted for each subject across the whole liver. The multi-parametric motion analysis reported relevant inter- and intrasubject variability, highlighting the value of patient-specific and spatially-distributed measurements. Surrogate-based tracking errors (relative to the motion amplitude) were were in the range 7% to 23% (1.02-3.57mm) and were significantly influenced by external motion parameters. The gain of MRI guidance compared to surrogate-based motion tracking was larger than 30% in 50% of the subjects when considering a 1.5-mm tracking error tolerance. Conclusions: Automatic feature detection applied to cine-MRI allows detailed liver motion description to be obtained. Such information was used to quantify the performance of surrogate-based tracking methods and to provide a prospective comparison with respect to MRI-guided radiation therapy, which could support the definition of patient-specific optimal treatment strategies.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Near field fluid coupling between internal motion of the organ of Corti and the basilar membrane

The pressure distribution in each of the fluid chambers of the cochlea can be decomposed into a 1D, or plane wave, component and a near field component, which decays rapidly away from the excitation point. The transverse motion of the basilar membrane, BM, for example, generates both a 1D pressure field, which couples into the slow wave, and a local near field pressure, proportional to the BM acceleration, that generates an added mass on the BM due to the fluid motion. When the organ of Corti, OC, undergoes internal motion, due for example to outer hair cell activity, this motion will not itself generate any 1D pressure if the OC is incompressible and the BM is constrained not to move volumetrically, and so will not directly couple into the slow wave. This motion will, however, generate a near field pressure, proportional to the OC acceleration, which will act on the OC and thus increases its effective mass. The near field pressure due to this OC motion will also act on the BM, generating a force on the BM proportional to the acceleration of the OC, and thus create a “coupling mass” effect. By reciprocity, this coupling mass is the same as that acting on the OC due to the motion of the BM. This near field fluid coupling is initially observed in a finite element model of a slice of the cochlea. These simulations suggest a simple analytical formulation for the fluid coupling, using higher order beam modes across the width of the cochlear partition. It is well known that the added mass due to the near field pressure dominates the overall mass of the BM, and thus significantly affects the micromechanical dynamics. This work not only quantifies the added mass of the OC due its own motion in the fluid, and shows that this is important, but also demonstrates that the coupling mass effect between the BM and OC significantly affects the dynamics of simple micromechanical models.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

UBIQUITOUS TORSIONAL MOTIONS IN TYPE II SPICULES

Spicules are long, thin, highly dynamic features that jut out ubiquitously from the solar limb. They dominate the interface between the chromosphere and corona and may provide significant mass and energy to the corona. We use high-quality observations with the Swedish 1 m Solar Telescope to establish that so-called type II spicules are characterized by the simultaneous action of three different types of motion: (1) field-aligned flows of order 50-100 km s{sup -1}, (2) swaying motions of order 15-20 km s{sup -1}, and (3) torsional motions of order 25-30 km s{sup -1}. The first two modes have been studied in detail before, but not the torsional motions. Our analysis of many near-limb and off-limb spectra and narrowband images using multiple spectral lines yields strong evidence that most, if not all, type II spicules undergo large torsional modulation and that these motions, like spicule swaying, represent Alfvenic waves propagating outward at several hundred km s{sup -1}. The combined action of the different motions explains the similar morphology of spicule bushes in the outer red and blue wings of chromospheric lines, and needs to be taken into account when interpreting Doppler motions to derive estimates for field-aligned flows in spicules and determining the Alfvenic wave energy in the solar atmosphere. Our results also suggest that large torsional motion is an ingredient in the production of type II spicules and that spicules play an important role in the transport of helicity through the solar atmosphere.

79 ASTRONOMY AND ASTROPHYSICS↗

The correlation of tissue motion within the lung: implications on fiducial based treatments

In radiation therapy many motion management and alignment techniques rely on the accuracy of an internal fiducial acting as a surrogate for target motion within the lung. Although fiducials are routinely used as surrogates for tumor motion, the extent to which varying spatial locations in the lung move similarly to other locations has yet to be quantitatively analyzed. In an attempt to analyze the motion correlation throughout the lung, ten primary lung cancer patients underwent IRB-approved 4DCT scans in the supine position. Deformable registration produced motion vectors for each voxel between exhalation and inhalation. Modeling was performed for each vector and all surrounding vectors within the lung in order to determine the mean 3D Euclidean distance necessary for an implanted fiducial to correlate with surrounding tissue motion to within 3 mm (left lower: 1.7 cm, left upper: 2.1 cm, right lower 1.6 cm, and right upper 2.9 cm). No general implantation rule of where to position a fiducial with respect to the tumor was found as the motion is highly patient and lobe specific. Correlation maps are presented showcasing spatial anisotropy of the motion of tissue surrounding the tumor.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Reduction of prostate intrafraction motion using gas-release rectal balloons

Purpose: To analyze prostate intrafraction motion using both non-gas-release (NGR) and gas-release (GR) rectal balloons and to evaluate the ability of GR rectal balloons to reduce prostate intrafraction motion. Methods: Twenty-nine patients with NGR rectal balloons and 29 patients with GR balloons were randomly selected from prostate patients treated with proton therapy at University of Florida Proton Therapy Institute (Jacksonville, FL). Their pretreatment and post-treatment orthogonal radiographs were analyzed, and both pretreatment setup residual error and intrafraction-motion data were obtained. Population histograms of intrafraction motion were plotted for both types of balloons. Population planning target-volume (PTV) margins were calculated with the van Herk formula of 2.5{Sigma}+ 0.7{sigma} to account for setup residual errors and intrafraction motion errors. Results: Pretreatment and post-treatment radiographs indicated that the use of gas-release rectal balloons reduced prostate intrafraction motion along superior-inferior (SI) and anterior-posterior (AP) directions. Similar patient setup residual errors were exhibited for both types of balloons. Gas-release rectal balloons resulted in PTV margin reductions from 3.9 to 2.8 mm in the SI direction, 3.1 to 1.8 mm in the AP direction, and an increase from 1.9 to 2.1 mm in the left-right direction. Conclusions: Prostate intrafraction motion is an important uncertainty source in radiotherapy after image-guided patient setup with online corrections. Compared to non-gas-release rectal balloons, gas-release balloons can reduce prostate intrafraction motion in the SI and AP directions caused by gas buildup.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Relative role of motion and PSF compensation in whole-body oncologic PET-MR imaging

Purpose: Respiratory motion and partial-volume effects are the two main sources of image degradation in whole-body PET imaging. Simultaneous PET-MR allows measurement of respiratory motion using MRI while collecting PET events. Improved PET images may be obtained by modeling respiratory motion and point spread function (PSF) within the PET iterative reconstruction process. In this study, the authors assessed the relative impact of PSF modeling and MR-based respiratory motion correction in phantoms and patient studies using a whole-body PET-MR scanner. Methods: An asymmetric exponential PSF model accounting for radially varying and axial detector blurring effects was obtained from point source acquisitions performed in the PET-MR scanner. A dedicated MRI acquisition protocol using single-slice steady state free-precession MR acquisitions interleaved with pencil-beam navigator echoes was developed to track respiratory motion during PET-MR studies. An iterative ordinary Poisson fully 3D OSEM PET reconstruction algorithm modeling all the physical effects of the acquisition (attenuation, scatters, random events, detectors efficiencies, PSF), as well as MR-based nonrigid respiratory deformations of tissues (in both emission and attenuation maps) was developed. Phantom and{sup 18}F-FDG PET-MR patient studies were performed to evaluate the proposed quantitative PET-MR methods. Results: The phantom experiment results showed that PSF modeling significantly improved contrast recovery while limiting noise propagation in the reconstruction process. In patients with soft-tissue static lesions, PSF modeling improved lesion contrast by 19.7%–109%, enhancing the detectability and assessment of small tumor foci. In a patient study with small moving hepatic lesions, the proposed reconstruction technique improved lesion contrast by 54.4%–98.1% and reduced apparent lesion size by 21.8%–34.2%. Improvements were particularly important for the smallest lesion undergoing large motion at the lung-liver interface. Heterogeneous tumor structures delineation was substantially improved. Enhancements offered by PSF modeling were more important when correcting for motion at the same time. Conclusions: The results suggest that the proposed quantitative PET-MR methods can significantly enhance the performance of tumor diagnosis and staging as compared to conventional methods. This approach may enable utilization of the full potential of the scanner in oncologic studies of both the lower abdomen, with moving lesions, as well as other parts of the body unaffected by motion.

62 RADIOLOGY AND NUCLEAR MEDICINE↗