Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “microscope”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Damage-free vibrational spectroscopy of biological materials in the electron microscope

Vibrational spectroscopy in the electron microscope would be transformative in the study of biological samples, provided that radiation damage could be prevented. However, electron beams typically create high-energy excitations that severely accelerate sample degradation. Here this major difficulty is overcome using an ‘aloof’ electron beam, positioned tens of nanometres away from the sample: high-energy excitations are suppressed, while vibrational modes of energies o1 eV can be ‘safely’ investigated. To demonstrate the potential of aloof spectroscopy, we record electron energy loss spectra from biogenic guanine crystals in their native state, resolving their characteristic C–H, N–H and C=O vibrational signatures with no observable radiation damage. Furthermore, the technique opens up the possibility of non-damaging compositional analyses of organic functional groups, including non-crystalline biological materials, at a spatial resolution of ~10nm, simultaneously combined with imaging in the electron microscope.

59 BASIC BIOLOGICAL SCIENCES↗

Machine learning the microscopic form of nematic order in twisted double-bilayer graphene

Modern scanning probe techniques, such as scanning tunneling microscopy, provide access to a large amount of data encoding the underlying physics of quantum matter. In this work, we show how convolutional neural networks can be used to learn effective theoretical models from scanning tunneling microscopy data on correlated moiré superlattices. Moiré systems are particularly well suited for this task as their increased lattice constant provides access to intra-unit-cell physics, while their tunability allows for the collection of high-dimensional data sets from a single sample. Using electronic nematic order in twisted double-bilayer graphene as an example, we show that incorporating correlations between the local density of states at different energies allows convolutional neural networks not only to learn the microscopic nematic order parameter, but also to distinguish it from heterostrain. These results demonstrate that neural networks are a powerful method for investigating the microscopic details of correlated phenomena in moiré systems and beyond.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Microscopic theory, analysis, and interpretation of conductance histograms in molecular junctions

Molecular electronics break-junction experiments are widely used to investigate fundamental physics and chemistry at the nanoscale. Reproducibility in these experiments relies on measuring conductance on thousands of freshly formed molecular junctions, yielding a broad histogram of conductance events. Experiments typically focus on the most probable conductance, while the information content of the conductance histogram has remained unclear. Here we develop a microscopic theory for the conductance histogram by merging the theory of force-spectroscopy with molecular conductance. The procedure yields analytical equations that accurately fit the conductance histogram of a wide range of molecular junctions and augments the information content that can be extracted from them. Our formulation captures contributions to the conductance dispersion due to conductance changes during the mechanical elongation inherent to the experiments. In turn, the histogram shape is determined by the non-equilibrium stochastic features of junction rupture and formation. The microscopic parameters in the theory capture the junction’s electromechanical properties and can be isolated from separate conductance and rupture force (or junction-lifetime) measurements. The predicted behavior can be used to test the range of validity of the theory, understand the conductance histograms, design molecular junction experiments with enhanced resolution and molecular devices with more reproducible conductance properties.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Correlating activities and defects in (photo)electrocatalysts using in-situ multi-modal microscopic imaging

Photo(electro)catalysts use sunlight to drive chemical reactions such as water splitting. A major factor limiting photocatalyst development is physicochemical heterogeneity which leads to spatially dependent reactivity. To link structure and function in such systems, simultaneous probing of the electrochemical environment at microscopic length scales and a broad range of timescales (ns to s) is required. Here, we address this challenge by developing and applying in- situ (optical) microscopies to map and correlate local electrochemical activity, with hole lifetimes, oxygen vacancy concentrations and photoelectrode crystal structure. Using this multi-modal approach, we study prototypical hematite (α-Fe 2 O 3 ) photoelectrodes. We demonstrate that regions of α-Fe 2 O 3 , adjacent to microstructural cracks have a better photoelectrochemical response and reduced back electron recombination due to an optimal oxygen vacancy concentration, with the film thickness and extended light exposure also influencing local activity. Our work highlights the importance of microscopic mapping to understand activity, in even seemingly homogeneous photoelectrodes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Extreme ultraviolet microscope characterization using photomask surface roughness

We demonstrate a method for characterizing the field-dependent aberrations of a full-field synchrotron-based extreme ultraviolet microscope. The statistical uniformity of the inherent, atomic-scale roughness of readily-available photomask blanks enables a self-calibrating computational procedure using images acquired under standard operation. We characterize the aberrations across a 30-um field-of-view, demonstrating a minimum aberration magnitude of smaller than λ/21 rms averaged over the center 5-um area, with a measurement accuracy better than λ/180 rms. The measured field variation of aberrations is consistent with system geometry and agrees with prior characterizations of the same system. In certain cases, it may be possible to additionally recover the illumination wavefront from the same images. Our method is general and is easily applied to coherent imaging systems with steerable illumination without requiring invasive hardware or custom test objects; hence, it provides substantial benefits when characterizing microscopes and high-resolution imaging systems in situ.

47 OTHER INSTRUMENTATION↗

Reducing experimental uncertainty in the calculation of cavity swelling in a transmission electron microscope through crystallographically aided void volume tracking

Accurate measurement of cavity swelling in a transmission electron microscope is essential to define material performance under irradiation, and the conventionally applied spherical assumption for the calculation of cavity volumes in irradiated materials can result in errors ranging between a 25% underestimation and 72% overestimation of volume purely based on the assumption of shape. This assumption is undeniably expedient for calculation but does not sufficiently account for the 3D nature of polyhedral cavities and their shape projection in the transmission electron microscope, and therefore presents too large of an associated uncertainty in swelling determination for faceted cavities. This uncertainty has been defined for many common cavity shapes in FCC and BCC crystal systems, and has been tabulated across the cubic fundamental region. A revised methodology for crystallographically aided void volume tracking, or CAVV-T, is presented and demonstrated on a specimen of neutron irradiated Ni. In-depth discussion on the application of this technique is provided along with resources to allow for conversion between the spherical assumption and this revised method. This work seeks to increase experimental confidence in the characterization and quantification of critical aspects of irradiation damage in materials by applying a crystallographically-resolved approach for cavity swelling calculation.

Haag IV, James V. [Pacific Northwest National Labo↗

Unsupervised data mining in nanoscale x-ray spectro-microscopic study of NdFeB magnet

Novel developments in X-ray based spectro-microscopic characterization techniques have increased the rate of acquisition of spatially resolved spectroscopic data by several orders of magnitude over what was possible a few years ago. This accelerated data acquisition, with high spatial resolution at nanoscale and sensitivity to subtle differences in chemistry and atomic structure, provides a unique opportunity to investigate hierarchically complex and structurally heterogeneous systems found in functional devices and materials systems. However, handling and analyzing the large volume data generated poses significant challenges. Here we apply an unsupervised data-mining algorithm known as DBSCAN to study a rare-earth element based permanent magnet material, Nd 2 Fe 14 B. We are able to reduce a large spectro-microscopic dataset of over 300,000 spectra to 3, preserving much of the underlying information. Scientists can easily and quickly analyze in detail three characteristic spectra. Our approach can rapidly provide a concise representation of a large and complex dataset to materials scientists and chemists. For instance, it shows that the surface of common Nd 2 Fe 14 B magnet is chemically and structurally very different from the bulk, suggesting a possible surface alteration effect possibly due to the corrosion, which could affect the material’s overall properties.

36 MATERIALS SCIENCE↗

Microscopic Theory of Fission

In recent years, the microscopic method has been applied to the notoriously difficult problem of nuclear fission with unprecedented success. In this paper, we discuss some of the achievements and promise of the microscopic method, as embodied in the Hartree-Fock method using the Gogny finite-range effective interaction, and beyond-mean-field extensions to the theory. The nascent program to describe induced fission observables using this approach at the Lawrence Livermore National Laboratory is presented.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Drip-line To Drip-line Microscopic Nuclear Level Densities

New energy-, spin- and parity-dependent nuclear level densities based on the microscopic combinatorial model are proposed for practical applications. The combinatorial model includes a detailed microscopic calculation of the intrinsic state density and of the rotational enhancement factor, but a phenomenological treatment of the vibrational effect. The vibrational description has been improved using a boson partition function to construct phonons' state densities which are then folded in with the incoherent particle-hole densities. The present model is shown to predict the experimental s-wave neutron resonance spacings with a degree of accuracy comparable to that of the best global models available.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Development of an ion beam alignment system for real-time scanning tunneling microscope observation of dopant-ion irradiation

An ion beam alignment system has been developed in order to realize real-time scanning tunneling microscope (STM) observation of 'dopant-ion' irradiation that has been difficult due to the low emission intensity of the liquid-metal-ion-source (LMIS) containing dopant atoms. The alignment system is installed in our original ion gun and STM combined system (IG/STM) which is used for in situ STM observation during ion irradiation. By using an absorbed electron image unit and a dummy sample, ion beam alignment operation is drastically simplified and accurized. We demonstrate that sequential STM images during phosphorus-ion irradiation are successfully obtained for sample surfaces of Si(111)-7x7 at room temperature and a high temperature of 500 deg. C. The LMIS-IG/STM equipped with the developed ion beam alignment system would be a powerful tool for microscopic investigation of the dynamic processes of ion irradiation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Microscopic solitons in correlated electronic systems: theory versus experiment

Symmetry broken electronic states give rise to topological defects: from extended domain walls - 'stripes' as solitonic lattices to microscopic solitons as anomalous quasi-particles and instantons in their dynamics. We shall collect and interpret experimental evidences on existence of microscopic solitons, and their determining role in electronic processes of quasi-1D electronic crystals. Thus, the ferroelectric charge ordering in organic conductors gives access to several types of solitons observed in conductivity (holons) and in permittivity (polar kinks), to solitons' bound pairs in optics, to compound charge-spin solitons. In charge density waves, the individual phase solitons have been visually captured in recent STM experiments. The resolved subgap tunneling spectra recover these solitons (in aggregated form of dislocations in statics and as instantons - the phase slips in dynamics), as well as the amplitude kinks - the spinons.The theory relies upon the regime of quantum dissipation provided by soft mode emittance in the course of the soliton creation, and on effects of dimensional crossover. With onset of a 2D or a 3D long range order, the topologically nontrivial solitons experience the confinement resulting in the spin-charge recombination. It originates the symmetry broken spin-or charge- roton configurations with charge- or spin- kinks localized in the core, correspondingly for cases of repulsion and attraction. These complex excitations can be viewed as nucleuses of the melted stripe phases, which appears in doped antiferromagnetic-Mott insulators or in spin-polarized superconductors and charge density waves.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A Microscopic Optical Potential Approach to {sup 6,8}He+p Elastic Scattering

A microscopic approach to calculate the optical potential (OP) with the real part obtained by a folding procedure and with the imaginary part inherent in the high-energy approximation (HEA) is applied to study the {sup 6,8}He+p elastic scattering data at energies of tens of MeV/N. The OP's and the cross sections are calculated using different models for the neutron and proton densities of {sup 6,8}He. The role of the spin-orbit (SO) potential and effects of the energy and density dependence of the effective NN forces are studied. Comparison of the calculations with the available experimental data on the elastic scattering differential cross sections at beam energies <100 MeV/N is performed and conclusions on the role of the aforesaid effects are made. It is shown that the present approach, which uses only parameters that renormalize the depths of the OP, can be applied along with other methods like that from the microscopic g-matrix description of the complex proton optical potential.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Multiple-scanning-probe tunneling microscope with nanoscale positional recognition function

Over the past decade, multiple-scanning-probe microscope systems with independently controlled probes have been developed for nanoscale electrical measurements. We developed a quadruple-scanning-probe tunneling microscope (QSPTM) that can determine and control the probe position through scanning-probe imaging. The difficulty of operating multiple probes with submicrometer precision drastically increases with the number of probes. To solve problems such as determining the relative positions of the probes and avoiding of contact between the probes, we adopted sample-scanning methods to obtain four images simultaneously and developed an original control system for QSPTM operation with a function of automatic positional recognition. These improvements make the QSPTM a more practical and useful instrument since four images can now be reliably produced, and consequently the positioning of the four probes becomes easier owing to the reduced chance of accidental contact between the probes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Confocal Microscope Alignment of Nanocrystals for Coherent Diffraction Imaging

We have installed and tested an Olympus LEXT confocal microscope at the 34-ID-C beamline of the Advanced Photon Source (APS). The beamline is for Coherent X-ray Diffraction (CXD) experiments in which a nanometre-sized crystal is aligned inside a focussed X-ray beam. The microscope was required for three-dimensional (3D) sample alignment to get around sphere-of-confusion issues when locating Bragg peaks in reciprocal space. In this way, and by use of strategic sample preparations, we have succeeded in measuring six Bragg peaks from a single 200 nm gold crystal and obtained six projections of its internal displacement field. This enables the clear identification of stacking-fault bands within the crystal. The confocal alignment method will allow a full determination of the strain tensor provided three or more Bragg reflections from the same crystal are found.

43 PARTICLE ACCELERATORS↗

Integration of an Atomic Force Microscope in a Beamline Sample Environment

We developed and optimised an optics-free Atomic Force Microscope (AFM) that can be directly installed on most of the synchrotron radiation end-stations. The combination of Scanning Probe Microscopies with X-ray microbeams adds new possibilities to the variety of synchrotron radiation techniques. The instrument can be used for atomic force imaging of the investigated sample or to locally measure the X-ray absorption or diffraction, or it can also be used to mechanically interact with the sample while simultaneously taking spectroscopy or diffraction measurements. The local character of these measurements is intrinsically linked with the use of the Atomic Force Microscope tip. It is the sharpness of the tip that gives the opportunity to measure the photons flux impinging on it giving beam position monitor features, or allows to locally measure the absorption coefficient or the shape of the diffraction pattern. As an example of the possibilities opened by the instrument we will show diffraction measurements performed on a Ge/Si island while being indented with the AFM tip providing local measure of the Young coefficient. Three ESRF beamlines are going to be equipped with this new instrument.

43 PARTICLE ACCELERATORS↗

Multiwalled carbon nanotubes and dispersed nanodiamond novel hybrids: Microscopic structure evolution, physical properties, and radiation resilience

We report the structure and physical properties of novel hybrids of multiwalled carbon nanotubes (MWCNTs) and ultradispersed diamond (UDD) forming nanocomposite ensemble that were subjected to 50, 100, and 10{sup 3} kGy gamma ray doses and characterized using various analytical tools to investigate hierarchical defects evolution. This work is prompted by recent work on single-walled CNTs and UDD ensemble [Gupta et al., J. Appl. Phys. 107, 104308 (2010)] where radiation-induced microscopic defects seem to be stabilized by UDD. The present experiments show similar effects where these hybrids display only a minimal structural modification under the maximum dose. Quantitative analyses of multiwavelength Raman spectra revealed lattice defects induced by irradiation assessed through the variation in prominent D, G, and 2D bands. A minimal change in the position of D, G, and 2D bands and a marginal increase in intensity of the defect-induced double resonant Raman scattered D and 2D bands are some of the implications suggesting the radiation coupling. The in-plane correlation length (L{sub a}) was also determined following Tunistra-Koenig relation from the ratio of D to G band (I{sub D}/I{sub G}) besides microscopic stress. However, we also suggest the following taking into account of intrinsic defects of the constituents: (a) charge transfer arising at the interface due to the difference in electronegativity of MWCNT C sp{sup 2} and UDD core (C sp{sup 3}) leading to phonon and electron energy renormalization; (b) misorientation of C sp{sup 2} at the interface of MWCNT and UDD shell (C sp{sup 2}) resulting in structural disorder; (c) softening or violation of the q{approx}0 selection rule leading to D band broadening and a minimal change in G band intensity; and (d) normalized intensity of D and G bands with 2D band help to distinguish defect-induced double resonance phenomena. The MWCNT when combined with nanodiamond showed a slight decrease in their conductance further affected by irradiation pointing at relatively good interfacial contact. Furthermore, owing to high thermal and electrical conductivity properties, they can facilitate potentially efficient heat-transfer applications and some results deduced using Nielsen's model is provided.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Surface Detection in a STXM Microscope

We have modified scanning transmission x-ray microscopes (STXM) at the Canadian Light Source and the Advanced Light Source with total electron yield (TEY) detection (TEY-STXM). This provides improved surface-sensitive detection, simultaneous with existing bulk-sensitive transmission detection in the STXM microscopes. We have explored sample-current and channeltron-based electron yield detection. Both approaches provide improved surface sensitive imaging and spectroscopy, although channeltron-based detection is superior. TEY-STXM provides surface sensitive imaging of ultrathin films such as phase-separated Langmuir-Blodgett monolayer films, as well as differentiation of surface and bulk oxides of patterned metallic thin films. This paper will outline the experimental challenges of this method and the opportunities for correlative surface and bulk measurements of complex samples.

07 ISOTOPE AND RADIATION SOURCES↗

Calibrated nanoscale dopant profiling using a scanning microwave microscope

The scanning microwave microscope is used for calibrated capacitance spectroscopy and spatially resolved dopant profiling measurements. It consists of an atomic force microscope combined with a vector network analyzer operating between 1-20 GHz. On silicon semiconductor calibration samples with doping concentrations ranging from 10{sup 15} to 10{sup 20} atoms/cm{sup 3}, calibrated capacitance-voltage curves as well as derivative dC/dV curves were acquired. The change of the capacitance and the dC/dV signal is directly related to the dopant concentration allowing for quantitative dopant profiling. The method was tested on various samples with known dopant concentration and the resolution of dopant profiling determined to 20% while the absolute accuracy is within an order of magnitude. Using a modeling approach the dopant profiling calibration curves were analyzed with respect to varying tip diameter and oxide thickness allowing for improvements of the calibration accuracy. Bipolar samples were investigated and nano-scale defect structures and p-n junction interfaces imaged showing potential applications for the study of semiconductor device performance and failure analysis.

36 MATERIALS SCIENCE↗