Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “measurement errors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Characterizing the performance of a POPS miniaturized optical particle counter when operated on a quadcopter drone

We first validate the performance of the Portable Optical Particle Spectrometer (POPS), a small light-weight and high sensitivity optical particle counter, against a reference scanning mobility particle sizer (SMPS) for a month-long deployment in an environment dominated by biomass burning aerosols. Subsequently, we examine any biases introduced by operating the POPS on a quadcopter drone, a DJI Matrice 200 V2. We report the root mean square difference (RMSD) and mean absolute difference (MAD) in particle number concentrations (PNCs) when mounted on the UAV and operating on the ground and when hovering at 10 m. When wind speeds are low (less than 2.6 m s –1 ), we find only modest differences in the RMSDs and MADs of 5 % and 3 % when operating at 10 m altitude. When wind speeds are between 2.6 and 7.7 m s –1 the RMSDs and MADs increase to 26.2 % and 19.1 %, respectively, when operating at 10m altitude. No statistical difference in PNCs was detected when operating on the UAV in either ascent or descent. We also find size distributions of aerosols in the accumulation mode (defined by diameter, d, where 0.1 ≤ d ≤ 1 µm) are relatively consistent between measurements at the surface and measurements at 10 m altitude, while differences in the coarse mode (here defined by d > 1 µm) are universally larger. Our results suggest that the impact of the UAV rotors on the POPS PNCs are small at low wind speeds, but when operating under a higher wind speed of up to 7.6 m s –1 , larger discrepancies occur. In addition, it appears that the POPS measures sub-micron aerosol particles more accurately than super-micron aerosol particles when airborne on the UAV. These measurements lay the foundations for determining the magnitude of potential errors that might be introduced into measured aerosol particle size distributions and concentrations owing to the turbulence created by the rotors on the UAV.

47 OTHER INSTRUMENTATION↗

Physically based correction of systematic errors of Rotating Shadowband Irradiometers

Accurate measurements of direct normal, diffuse horizontal and global horizontal irradiance (DNI, DHI and GHI) are needed for meteorological studies and are essential for the solar resource assessment at potential solar power plant sites. Often, these potential sites are remote and hence require robust sensors that require minimal maintenance that are not affected strongly by soiling. Therefore, Rotating Shadowband Irradiometers (RSI) are widely used for resource assessment. To achieve the required accuracy, corrections for the raw values of RSIs depending on systematic temperature, incidence angle and spectral errors must be used, and a thorough calibration of the sensor head must be applied. The existing correction functions are derived from comparisons of RSIs to thermopile radiometers at selected sites and therefore empirical. Their accuracy is considered to be site dependent. In this work a new correction and calibration method is presented that removes the systematic errors using a physical approach. It is based on information of the sensor properties as well as measurements of its directional response, and incorporates the atmospheric conditions at the measurement site. In this case, no empiric relations obtained from a specific site are required. The method requires estimates of the current DHI and GHI spectra during each measurement of the RSI. Based on these spectra, a spectral correction, which includes a spectrum dependent temperature correction, can be made without employing empirical relationships. The new physical calibration and correction method is tested at three sites and reaches similar results compared to the empirical functions. This is already achieved with rudimentary estimations of the GHI and DHI spectra and we expect that these estimations can be improved in the future. The results indicate that the physical approach reduces the problematic location dependence of the current calibration and correction methods. The physical correction and calibration method show promise for a further improvement of the RSI accuracy.

47 OTHER INSTRUMENTATION↗

Investigating the application of Kalman Filters for real-time accountancy in fusion fuel cycles

Here tritium accountancy in the fusion fuel cycle is a significant concern for the operation of commercial devices. It is expected that a limit on the maximum amount of tritium inventory in the system will be implemented, meaning that accountancy of the tritium inventory in the fuel cycle will need to be as accurate as possible. This is difficult since not all locations along the fuel cycle can benefit from the implementation of a tritium accountancy sensor and measurements will inherently contain error. Commercial fusion plants will also operate continuously, challenging current accountancy techniques that rely on static processes in well-controlled environments. In this paper a simple fusion fuel cycle concept is defined and the tritium inventory over time of each component is modelled using the Euler Approximation of a series of differential Equations in Python. This information is then used to simulate sensor measurements at specific points on the fuel cycle and then passed through a Kalman Filter (KF) to improve the accuracy of the true measurement of the sensors.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Soft syndrome iterative decoding of quantum LDPC codes and hardware architectures

In practical quantum error correction implementations, the measurement of syndrome information is an unreliable step—typically modeled as a binary measurement outcome flipped with some probability. However, the measured syndrome is in fact a discretized value of the continuous voltage or current values obtained in the physical implementation of the syndrome extraction. In this paper, we use this “soft” or analog information to benefit iterative decoders for decoding quantum low-density parity-check (QLDPC) codes. Syndrome-based iterative belief propagation decoders are modified to utilize the soft syndrome to correct both data and syndrome errors simultaneously. We demonstrate the advantages of the proposed scheme not only in terms of comparison of thresholds and logical error rates for quasi-cyclic lifted-product QLDPC code families but also with faster convergence of iterative decoders. Additionally, we derive hardware (FPGA) architectures of these soft syndrome decoders and obtain similar performance in terms of error correction to the ideal models even with reduced precision in the soft information. The total latency of the hardware architectures is about 600 ns (for the QLDPC codes considered) in a 20 nm CMOS process FPGA device, and the area overhead is almost constant—less than 50% compared to min-sum decoders with noisy syndromes.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Phase diagram of the three-dimensional subsystem toric code

Subsystem quantum error-correcting codes typically involve measuring a sequence of noncommuting parity check operators. They can sometimes exhibit greater fault tolerance than conventional codes, which use commuting checks. However, unlike subspace codes, it is unclear if subsystem codes—in particular their advantages—can be understood in terms of ground-state properties of a physical Hamiltonian. In this paper, we address this question for the three-dimensional subsystem toric code (3D STC), as recently constructed by Kubica and Vasmer [], which exhibits single-shot error correction. Motivated by a conjectured relation between single-shot properties and thermal stability, we study the zero- and finite-temperature phases of an associated noncommuting Hamiltonian. By mapping the Hamiltonian model to a pair of 3D Z 2 gauge theories coupled by a kinetic constraint, we find various phases at zero temperature, all separated by first-order transitions: There are 3D toric code-like phases with deconfined point-like excitations in the bulk, and there are phases with a confined bulk supporting a 2D toric code on the surface when appropriate boundary conditions are chosen. The latter is similar to the surface topological order present in 3D STC. However, the similarities between the single-shot correction in 3D STC and the confined phases are only partial: they share the same sets of degrees of freedom, but they are governed by different dynamical rules. Instead, we argue that the process of single-shot error correction can more suitably be associated with a path (rather than a point) in the zero-temperature phase diagram, a perspective, which inspires alternative measurement sequences enabling single-shot error correction. Moreover, since none of the above-mentioned phases survives at nonzero temperature, the single-shot error-correction property of the code does not imply thermal stability of the associated Hamiltonian phase. Published by the American Physical Society 2024

Li, Yaodong (ORCID:0000000337421944)↗

Lifetime measurements of states of S 35 , S 36 , S 37 , and S 38 using the AGATA γ -ray tracking spectrometer

Lifetimes or lifetime limits of a small number of excited states of the sulfur isotopes with mass numbers A = 35 , 36, 37, and 38 have been measured using the differential recoil-distance method. The isotopes of sulfur were populated in binary grazing reactions initiated by a beam of 36 S ions of energy 225 MeV incident on a thin 208 Pb target which was mounted in the Cologne plunger apparatus. The combination of the PRISMA magnetic spectrometer and an early implementation of the AGATA γ-ray tracking array was used to detect γ rays in coincidence with projectile-like nuclear species. Lifetime measurements of populated states were measured within the range from about 1 to 100 ps. The number of states for which lifetime measurements or lifetime limits were possible was limited by statistics. For 35 S, the lifetime was determined for the first 1/2 + state at 1572 keV; the result is compared with a previous published lifetime value. The lifetime of the 3 - state of 36 S at 4193 keV was determined and compared with earlier measurements. No previous lifetime information exists for the (6 + ) state at 6690 keV; a lifetime measurement with large associated error was made in the present work. For 37 S, the states for which lifetime limits were established were those at 646 keV with J π = 3/2 - and at 2776 keV with J π = 11/2 - ; there are no previously published lifetime values for excited states of 37 S. Finally, a lifetime limit was established for the J π =(6 + ) state of 38 S at 3675 keV; no lifetime information exists for this state in the literature. Measured lifetime values were compared with the results of state-of-the-art shell-model calculations based on the PSDPF, SDPF-U, and FSU effective interactions. In addition, nuclear magnetic-dipole and electric-quadrupole moments, branching ratios, mixing ratios, and electromagnetic transition rates, where available, have been compared with shell-model values. The current work suffers from poor statistics; nevertheless, lifetime values and limits have been possible, allowing a useful discussion of the ability of state-of-the-art shell-model calculations to reproduce the experimental results.

electromagnetic transitions↗

Optical measure of disorder: Why Urbach analysis works for amorphous silicon but fails for amorphous carbon

We investigate the basis for the Paradox where the Urbach-slope disorder parameter disagrees with the Raman width in amorphous diamond-like carbon (DLC) materials (lower Urbach-Eo yet greater Raman width). We examined the bandgap and Urbach-slope measurement issues. While significant errors are identified, ultimately these cannot resolve the Paradox. This resolution involves large changes in shape of DLC's absorption band resulting from large energy shifts. To solidify the understanding of band energy shifts, we examined their properties using a-Si:H, well known for its agreement between Raman and Urbach-slope disorder parameters. Using Tauc-Lorentz (T-L) dispersion functions, the Urbach method works for a-Si:H because small changes in shape occur, as measured by (i) peak position, (ii) peak width, (iii) peak amplitude, and (iv) and gap energies. Moreover, for a-Si:H, a 5th condition (v) there is no other feature below the principal band to interfere with its fall. All 5 of these conditions fail for DLCs. Because T-L dispersions accommodate asymmetry, we traced the Paradox to a steepening of the band shape as it pushes toward lower energy. This steepening is unrelated to disorder, but to a boundary value problem where energy cannot be negative. We conclude that Urbach analysis is invalid for DLC materials, but the T-L width is a good measure instead. We also examined another disorder measure, where π bonds should be considered as disorder relative to the σ bonds in an idealized “amorphous diamond” sp 3 network: superconvergence can be used to quantify these π transitions. Finally, further molecular orbital calculations are needed to properly interpret the changes in T-L widths.

36 MATERIALS SCIENCE↗

Analysis of Long-Term Quality Control Data for a 137 Cs Dosimetry Calibration Source

Strict quality assurance programs are required for many radiological applications, but these seldom exist for verifying dosimetry calibration sources. After initial characterization of a dosimetry calibration facility, quality control procedures are recommended to ensure the early detection of any changes or malfunctions. These also result in refined knowledge about average dose rate and experimental variations in dose delivery. This paper describes the implementation of a phase I quality control protocol for a 137 Cs dosimetry calibration source and includes an analysis of the resulting data collected over a 24-mo period. During this time, substantial data was collected to establish trial control limits. Air kerma rate measurements were obtained using an ion chamber and were adjusted for decay, corrected for ambient temperature, pressure and humidity, and then analyzed using quality control charts. Three variations of rational subgrouping methods were used in order to find assignable causes of error, and Nelson's Rules were followed to detect any non-random statistical variations. Measurements were subgrouped according to same-day measurements in order to detect positional errors as well as atmospheric correction errors. Additionally, measurements were subgrouped according to analogous experimental setups in order to detect failure in equipment or incorrect settings. Both were analyzed using the X-bar and R chart method. Similarly, individuals and moving ranges charts were used to carefully examine each position in order to observe any situational errors that may occur which include timing, positional, or interference errors. Each method was successful in identifying unique out-of-control data points that occurred during the phase I application of forming control limits. Furthermore, over the 24-mo period, enough data points were deemed in-control to establish reliable trial limits. Future experiments will include the phase II application of gaining more reliable measurements in order to fine-tune the limits, as well as performing a designed experiment, where variables are purposefully changed in order to test the variation of the data.

61 RADIATION PROTECTION AND DOSIMETRY↗

Quantification of regional net CO 2 flux errors in the Orbiting Carbon Observatory-2 (OCO-2) v10 model intercomparison project (MIP) ensemble using airborne measurements

Inverse model intercomparison projects (MIPs) provide a chance to assess the uncertainties in inversion estimates arising from various sources. However, accurately quantifying ensemble CO 2 flux errors remains challenging and often relies on the ensemble spread. This study proposes a method for quantifying the errors in regional net surface–atmosphere CO 2 flux estimates from models taken from the Orbiting Carbon Observatory-2 (OCO-2) v10 MIP by using independent airborne CO 2 measurements for the period 2015–2017. We first calculate the root mean square error (RMSE) between the ensemble mean of posterior CO 2 concentrations and airborne observations and then isolate the CO 2 concentration errors caused solely by the ensemble mean of posterior net fluxes by subtracting the observation, representation, and transport errors from seven regions. Our analysis reveals that the flux errors projected onto CO 2 space account for 55 %–85 % of the regional average RMSE over the 3 years, ranging from 0.88 to 1.91 ppm. In five regions, the error estimates based on observations exceed those computed from the ensemble spread of posterior fluxes by a factor of 1.33–1.93, implying an underestimation of the actual flux errors, while their magnitudes are comparable in two regions. The adjoint sensitivity analysis identifies that the underestimation of flux errors is prominent where the magnitudes of fossil fuel emissions exceed those of terrestrial-biosphere fluxes by a factor of 3–31 over the 3 years. This suggests the presence of systematic biases in the inversion estimates associated with errors in the prescribed fossil fuel emissions common to all models. Our study emphasizes the value of airborne measurements for quantifying regional errors in ensemble net CO 2 flux estimates.

54 ENVIRONMENTAL SCIENCES↗

Stellar reddening map from DESI imaging and spectroscopy

We present new Galactic reddening maps of the high Galactic latitude sky using DESI imaging and spectroscopy. We directly measure the reddening of 2.6 million stars by comparing the observed stellar colors in $g-r$ and $r-z$ from DESI imaging with the synthetic colors derived from DESI spectra from the first two years of the survey. The reddening in the two colors is on average consistent with the Fitzpatrick (1999) extinction curve with $R_\mathrm{V}=3.1$ . We find that our reddening maps differ significantly from the commonly used Schlegel et al. (1998) (SFD) reddening map (by up to 80 mmag in $E(B-V)$ ), and we attribute most of this difference to systematic errors in the SFD map. To validate the reddening map, we select a galaxy sample with extinction correction based on our reddening map, and this yields significantly better uniformity than the SFD extinction correction. Finally, we discuss the potential systematic errors in the DESI reddening measurements, including the photometric calibration errors that are the limiting factor on our accuracy. The $E(g-r)$ and $E(r-z)$ maps presented in this work, and for convenience their corresponding $E(B-V)$ maps with SFD calibration, are publicly available.

79 ASTRONOMY AND ASTROPHYSICS↗

Picosecond magneto-optic thermometry measurements of nanoscale thermal transport in AlN thin films

The thermal conductivity Λ of wide bandgap semiconductor thin films, such as AlN, affects the performance of high-frequency devices, power devices, and optoelectronics. However, accurate measurements of Λ in thin films with sub-micrometer thicknesses and Λ > 100 W m -1 K -1 is challenging. Widely used pump/probe metrologies, such as time–domain thermoreflectance (TDTR) and frequency–domain thermoreflectance, lack the spatiotemporal resolution necessary to accurately quantify thermal properties of sub-micrometer thin films with high Λ. In this work, we use a combination of magneto-optic thermometry and TiN interfacial layers to significantly enhance the spatiotemporal resolution of pump/probe thermal transport measurements. We use our approach to measure Λ of 100, 400, and 1000 nm AlN thin films. We coat AlN thin films with a ferromagnetic thin-film transducer with the geometry of (1 nm-Pt/0.4 nm-Co) x3 /(2 nm-TiN). This PtCo/TiN transducer has a fast thermal response time of <50 ps, which allows us to differentiate between the thermal response of the transducer, AlN thin film, and substrate. For the 100, 400, and 1000 nm thick AlN films, we determine Λ to be 200 ± 80, 165 ± 35, and 300 ± 70 W m -1 K -1 , respectively. We conclude with an uncertainty analysis that quantifies the errors associated with pump/probe measurements of thermal conductivity, as a function of transducer type, thin-film thermal conductivity, and thin-film thickness. Time resolved magneto-optic Kerr effect experiments can measure films that are three to five times thinner than is possible with standard pump/probe metrologies, such as TDTR. This advance in metrology will enable better characterization of nanoscale heat transfer in high thermal conductivity material systems like wide bandgap semiconductor heterostructures and devices.

36 MATERIALS SCIENCE↗

Automated Shift Detection in Sensor-Based PV Power and Irradiance Time Series: Preprint

PV power and irradiance sensor-based measurements are prone to error, resulting in issues such as abrupt time series data shifts. These shifts, which are usually unintentional, may be caused by software or hardware configuration changes on a PV system, and do not reflect an actual change in overall system performance. Locating these shifts and segmenting the associated time series aids in more accurate future PV analysis. In this research, an offline changepoint detection (CPD) algorithm that automatically detects these abrupt data shifts in sensor-based time series is introduced. Data shift periods in 101 daily PV power and irradiance time series were labeled manually by two solar experts. These data streams represent sensor-based measurements, and display a variety of data shift behaviors. A changepoint detection algorithm was tuned using the 101 labeled data streams, with each model configuration's ability to detect labeled changepoints benchmarked using metrics such as F1-score, recall, and Rand Index. Best performing models on seasonality-corrected data streams include the Pruned Exact Linear (PELT) method, the Binary Segmentation method, and the Bottom-Up method, all scoring an average F1-score of 0.76 or greater at detecting labeled changepoints within a 30-day window for the labeled data sets. To promote further research in this space, we are releasing the labeled data shift sets on U.S. Department of Energy's (DOE) DuraMAT Data Hub, and the associated algorithm in the Python PVAnalytics package.

changepoint detection↗

Automated Shift Detection in Sensor-Based PV Power and Irradiance Time Series

PV power and irradiance sensor-based measurements are prone to error, resulting in issues such as abrupt time series data shifts. These shifts, which are usually unintentional, may be caused by software or hardware configuration changes on a PV system, and do not reflect an actual change in overall system performance. Locating these shifts and segmenting the associated time series aids in more accurate future PV analysis. In this research, an offline changepoint detection (CPD) algorithm that automatically detects these abrupt data shifts in sensor-based time series is introduced. Data shift periods in 101 daily PV power and irradiance time series were labeled manually by two solar experts. These data streams represent sensor-based measurements, and display a variety of data shift behaviors. A changepoint detection algorithm was tuned using the 101 labeled data streams, with each model configuration's ability to detect labeled changepoints benchmarked using metrics such as F1-score, recall, and Rand Index. Best performing models on seasonality-corrected data streams include the Pruned Exact Linear (PELT) method, the Binary Segmentation method, and the Bottom-Up method, all scoring an average F1-score of 0.76 or greater at detecting labeled changepoints within a 30-day window for the labeled data sets. To promote further research in this space, we are releasing the labeled data shift sets on U.S. Department of Energy's (DOE) DuraMAT Data Hub, and the associated algorithm in the Python PVAnalytics package.

changepoint detection↗

Uncertainty Error Modeling for Non-Linear State Estimation With Unsynchronized SCADA and µPMU Measurements

Distribution systems of the future smart grid require enhancements to the reliability of distribution system state estimation (DSSE) in the face of low measurement redundancy, unsynchronized measurements, and dynamic load profiles. Micro phasor measurement units (µPMUs) facilitate co-synchronized measurements with high granularity, albeit at an often prohibitively expensive installation cost. Supervisory control and data acquisition (SCADA) measurements can supplement µPMU data, although they are received at a slower sampling rate. Further complicating matters is the uncertainty associated with load dynamics and unsynchronized measurements–not only are the SCADA and µPMU measurements not synchronized with each other, but the SCADA measurements themselves are received at different time intervals with respect to one another. This paper proposes a non-linear state estimation framework which models dynamic load uncertainty error by updating the variances of the unsynchronized measurements, leading to a time-varying system of weights in the weighted least squares state estimator. Case studies are performed on the 33-Bus Distribution System in MATPOWER, using Ornstein–Uhlenbeck stochastic processes to simulate dynamic load conditions.

Cooper, Austin↗

A Graph Convolutional Network for Active Distribution System Anomaly Detection Considering Measurement Spatial-Temporal Correlations

The accuracy of distribution system state estimation may be significantly impacted by the existence of bad measure-ments and unexpected topology errors. This paper proposes a data-driven Graph Convolutional Network (GCN) for anomaly detection, including bad measurements and topology change events. Compared to many existing machine learning approaches, the proposed approach embeds both spatial-temporal measure-ment correlations, which allows us to detect and distinguish different anomalies. Numerical results carried out on the IEEE 37-node system demonstrate that the proposed-based method can obtain high accuracy in detecting bad data and topology changes as compared to other approaches, even in the presence of high PV penetrations.

active distribution system↗

Mobility and threshold voltage extraction in transistors with gate-voltage-dependent contact resistance

The mobility of emerging (e.g., two-dimensional, oxide, organic) semiconductors is commonly estimated from transistor current-voltage measurements. However, such devices often experience contact gating, i.e., electric fields from the gate modulate the contact resistance during measurements, which can lead conventional extraction techniques to estimate mobility incorrectly even by a factor >2. Although this error can be minimized by measuring transistors at high gate-source bias |V gs |, this regime is often inaccessible in emerging devices that suffer from high contact resistance or early gate dielectric breakdown. Here, we propose a method of extracting mobility in transistors with gate-dependent contact resistance that does not require operation at high |V gs |, enabling accurate mobility extraction even in emerging transistors with strong contact gating. Our approach relies on updating the transfer length method (TLM) and can achieve <10% error even in regimes where conventional techniques overestimate mobility by >2×

36 MATERIALS SCIENCE↗

PELICAN Status Report for Year 2021

The Pressure Drop Experimental Loop for Investigations of Core Assemblies in Advanced Nuclear Reactors, PELICAN, is a novel experimental facility designed and constructed to recreate the prototypic full scale hydraulic flow conditions for the Versatile Test Reactor (VTR) currently under development by the U.S. Department of Energy. To support VTR design efforts, PELICAN is used to replicate VTR’s primary heat transport system (PHTS) in the core assembly region. The measurement objectives for data generated from this test facility are to mimic the prototypic VTR assembly and to meet the validation needs for code calculations and simulations of the reference design for the VTR core. These objectives focus on the need to validate pressure drop results across the various segments of the fuel assembly, including the axial reflectors, fuel, and transition regions, as they relate directly to the pumping power and safety behavior of the reactor. In the following sections, the major milestones for the experimental work performed on PELICAN over the calendar year (CY) 2021 are presented. In the next section, we discuss the assembly and shakedown testing of the facility. In Section 3, an analysis of the errors in the major measurements is performed. In Section 4 and 5 we present the results from the first set of test articles placed inside the loop. The design of the remaining test articles as part of the full assembly are shown in Section 6 and the conclusion and path forward for the following year, CY22 is given in the final section.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Measuring Galactic dark matter through unsupervised machine learning

ABSTRACT Measuring the density profile of dark matter in the Solar neighbourhood has important implications for both dark matter theory and experiment. In this work, we apply autoregressive flows to stars from a realistic simulation of a Milky Way-type galaxy to learn – in an unsupervised way – the stellar phase space density and its derivatives. With these as inputs, and under the assumption of dynamic equilibrium, the gravitational acceleration field and mass density can be calculated directly from the Boltzmann equation without the need to assume either cylindrical symmetry or specific functional forms for the galaxy’s mass density. We demonstrate our approach can accurately reconstruct the mass density and acceleration profiles of the simulated galaxy, even in the presence of Gaia-like errors in the kinematic measurements.

Astronomy & Astrophysics↗