Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “measurement errors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Laboratory calibration of AAFE radiometer/scatterometer (RADSCAT)

A brief description of the electrical and mechanical instrument configuration, followed by an extensive discussion of laboratory tests and results are contained herein. This information is required to provide parameters for data reduction, and a basis for analysis of the measurement errors in data taken with this instrument.

Schroeder, L. C.↗

Load-displacement measurement and work determination in three-point bend tests of notched or precracked specimens

Suggestions for testing of notched or cracked three-point bend specimens are presented which: (1) correct displacement measurement errors resulting from misalignment between the load applicator and specimen; (2) account for coincidental strains not associated with the work of crack extension; (3) simplify record analysis and processing; and (4) extend displacement gage range without sacrifice of sensitivity or accuracy. These testing details are particularly applicable to procedures in which the crack extension force is determined from the work done on the specimen.

Buzzard, R. J.↗

Pseudo noise test set operation manual

Pseudonoise (PN) test set was designed to provide a reliable, operationally simple unit which allows the previously mentioned analog rms end-to-end error measurement of most communication systems to be easily performed. It also provides a band-limited pseudorandom noise as input, thereby escaping the disadvantages of most deterministic signals while retaining the advantages of using true-band-limited noise. In addition, the PN test set has the capability to be used as a means with which the autocorrelation function and impulse response may be determined for certain systems.

Weathers, G.↗

The mean magnetic field of the sun: Observations at Stanford

A solar telescope was built at Stanford University to study the organization and evolution of large-scale solar magnetic fields and velocities. The observations are made using a Babcock-type magnetograph which is connected to a 22.9 m vertical Littrow spectrograph. Sun-as-a-star integrated light measurements of the mean solar magnetic field were made daily since May 1975. The typical mean field magnitude is about 0.15 gauss with typical measurement error less than 0.05 gauss. The mean field polarity pattern is essentially identical to the interplanetary magnetic field sector structure (seen near the earth with a 4 day lag). The differences in the observed structures can be understood in terms of a warped current sheet model.

Scherrer, P. H.↗

Least squares polynomial fits and their accuracy

Equations are presented which attempt to fit least squares polynomials to tables of date. It is concluded that much data are needed to reduce the measurement error standard deviation by a significant amount, however at certain points great accuracy is attained.

Lear, W. M.↗

Regions of constrained maximum likelihood parameter identifiability

This paper considers the parameter identification problem of general discrete-time, nonlinear, multiple-input/multiple-output dynamic systems with Gaussian-white distributed measurement errors. Knowledge of the system parameterization is assumed to be known. Regions of constrained maximum likelihood (CML) parameter identifiability are established. A computation procedure employing interval arithmetic is proposed for finding explicit regions of parameter identifiability for the case of linear systems. It is shown that if the vector of true parameters is locally CML identifiable, then with probability one, the vector of true parameters is a unique maximal point of the maximum likelihood function in the region of parameter identifiability and the CML estimation sequence will converge to the true parameters.

Lee, C.-H.↗

A microprocessor controlled pressure scanning system

A microprocessor-based controller and data logger for pressure scanning systems is described. The microcomputer positions and manages data from as many as four 48-port electro-mechanical pressure scanners. The maximum scanning rate is 80 pressure measurements per second (20 ports per second on each of four scanners). The system features on-line calibration, position-directed data storage, and once-per-scan display in engineering units of data from a selected port. The system is designed to be interfaced to a facility computer through a shared memory. System hardware and software are described. Factors affecting measurement error in this type of system are also discussed.

Anderson, R. C.↗

Maximum theoretical angular accuracy of planar and linear arrays of sensors

The maximum theoretical accuracy in the angular location of a radiating object that can be obtained by using a planar or linear array is studied. The elements are assumed to have identical radiation patterns and the complex voltages observed at their ports are assumed to be subject to phase measurement errors, having normal probability density. An optimum scheme for the statistical extraction of the parameters defining the direction is established noting that the presence of thermal noise does not affect the structure of the estimator. Comparisons with the conventional multiple interferometric techniques are made.

Borgiotti, G. V.↗

Cosine-corrected optical diffuser

In solar energy utilization studies, correct measurements of flux arriving at other angles to optical axis must be given. Developed device (Cosine diffuser) significantly reduces measurement errors. In combination of radiation transmitter and diffuser co-operating with collimated optical instrument, relative aperture of instrument is filled.

Estey, R. S.↗

Nucleonic coal detector with independent, hydropneumatic suspension

The design of a nucleonic, coal interface detector which measures the depth of coal on the roof and floor of a coal mine is presented. The nucleonic source and the nucleonic detector are on independent hydropneumatic suspensions to reduce the measurement errors due to air gap.

Jones, E. W.↗

A gamma-ray testing technique for spacecraft

The simulated cosmic radiation effect on a spacecraft structure is evaluated by gamma ray testing in relation to structural thickness. A drawing of the test set-up is provided and measurement errors are discussed.

Gribov, B. S.↗

C-band radar calibration using GEOS-3

The various methods of determining tracking radar measurement error parameters are described, along with the projected accuracy of results. Typical examples and results for calibration of radars tracking the GEOS-3 satellite are presented.

Krabill, W. B.↗

Estimation of the sea surface's two-scale backscatter parameters

The relationship between the sea-surface normalized radar cross section and the friction velocity vector is determined using a parametric two-scale scattering model. The model parameters are found from a nonlinear maximum likelihood estimation. The estimation is based on aircraft scatterometer measurements and the sea-surface anemometer measurements collected during the JONSWAP '75 experiment. The estimates of the ten model parameters converge to realistic values that are in good agreement with the available oceanographic data. The rms discrepancy between the model and the cross section measurements is 0.7 db, which is the rms sum of a 0.3 db average measurement error and a 0.6 db modeling error.

Wentz, F. J.↗

Snow parameters from Nimbus-6 electrically scanned microwave radiometer

Two sites in Canada were selected for detailed analysis of the ESMR-6/ snow relationships. Data were analyzed for February 1976 for site 1 and January, February and March 1976 for site 2. Snowpack water equivalents were less than 4.5 inches for site 1 and, depending on the month, were between 2.9 and 14.5 inches for site 2. A statistically significant relationship was found between ESMR-6 measurements and snowpack water equivalents for the Site 2 February and March data. Associated analysis findings presented are the effects of random measurement errors, snow site physiolography, and weather conditions on the ESMR-6/snow relationship.

Abrams, G.↗

Optical measurements of the droplet size distribution in the case of fuel atomization in swirl nozzles and planar airblast diffusers

The theoretical principles of optical methods for the determination of the particle sizes of sprays are considered and aspects of the experimental implementation of these principles are discussed. An experimental device for point-intensity measurements makes use of a helium-neon laser. The cross-sectional area of the laser beam is enlarged with the aid of a lens system to the size of the measurement cross-section. The intensity of the laser light scattered by the spray particles is measured as a function of light direction. Approaches which take into account the total energy of the diffractively scattered light are also discussed and an investigation is conducted regarding the measurement error sources. A description is presented of experimental results obtained in studies of a number of fuel nozzle sprays.

Kayser, A.↗

Blade row dynamic digital compression program. Volume 2: J85 circumferential distortion redistribution model, effect of Stator characteristics, and stage characteristics sensitivity study

The results of dynamic digital blade row compressor model studies of a J85-13 engine are reported. The initial portion of the study was concerned with the calculation of the circumferential redistribution effects in the blade-free volumes forward and aft of the compression component. Although blade-free redistribution effects were estimated, no significant improvement over the parallel-compressor type solution in the prediction of total-pressure inlet distortion stability limit was obtained for the J85-13 engine. Further analysis was directed to identifying the rotor dynamic response to spatial circumferential distortions. Inclusion of the rotor dynamic response led to a considerable gain in the ability of the model to match the test data. The impact of variable stator loss on the prediction of the stability limit was evaluated. An assessment of measurement error on the derivation of the stage characteristics and predicted stability limit of the compressor was also performed.

Tesch, W. A.↗

The mean magnetic field of the sun - Observations at Stanford

A solar telescope has been built to study the organization and evolution of large-scale solar magnetic fields and velocities. The observations are made using a Babcock-type magnetograph connected to a 22.9-m vertical Littrow spectrograph. Sun-as-a-star integrated-light measurements of the mean solar magnetic field have been made daily since May 1975. The typical mean-field magnitude has been about 0.15 G, with a typical measurement error of less than 0.05 G. The mean-field polarity pattern is essentially identical to the interplanetary-magnetic-field sector structure (seen near earth with a four-day lag). The differences in the observed structures can be understood in terms of a 'warped current sheet' model.

Scherrer, P. H.↗

Load-displacement measurement and work determination in three-point bend tests of notched or precracked specimens

Suggestions for testing of notched or cracked three-point bend specimens are presented that (1) correct displacement measurement errors resulting from misalignment between the load applicator and specimen; (2) account for coincidental strains not associated with the work of crack extension; (3) simplify record analysis and processing; and (4) extend displacement gage range without sacrifice of sensitivity or accuracy. These testing details are particularly applicable to procedures in which the crack extension force J(I) is determined from the work done on the specimen.

Buzzard, R. J.↗