Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “measurement bandwidth”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Acoustic gas volume fraction measurement in a multiphase flowing liquid

Apparatus and methods for the measurement of gas volume fraction of produced oil are described. A first method measures the response of a pipe containing the produced oil excited by a source of vibration in the form of an acoustic frequency chirp containing a linearly varying range of frequencies in the tens of kilohertz range encompassing at least one resonant mode of the pipe. As the gas volume fraction increases, the location of the peak maximum of the measured frequency spectrum responsive to the excitation increases in frequency, and the height of the peak maximum increases, thereby permitting a linear calibration curve to be obtained. A second method measures the response of a pipe containing the produced oil to excitation by a continuous source of vibration having a chosen frequency above those which excite flexural vibrations in the pipe and simultaneously excite acoustic waves in the fluid contained in the pipe, known as the coincidence frequency. Gas present in the fluid will interrupt sound propagation or reverberation, thereby generating fluctuations in the amplitude of the measured vibrations of the pipe. The amplitude fluctuation level provides a measure of the gas volume present inside the pipe. A third method measures the response of a pipe containing the produced oil to excitation by a high-bandwidth, short pulse having a chosen center frequency above the coincidence frequency. Gas present in the fluid will interrupt pulse propagation, thereby generating fluctuations in the amplitude of the measured vibrations of the pipe.

Sinha, Dipen N.↗

A Vibrational Energy Harvesting Sensor Based on Linear and Rotational Electromechanical Effects

In this investigation, a magnetically coupled double-spring design is presented for harvesting low-level non-stationary random vibrational energy. The sensor relies on multimodal coupling between the translation and rotation of a two-spring magnet and coil system to widen the harvesting bandwidth. Energy methods are used to develop a model to characterize the electromechanical response of the system, the solution of which is obtained using stochastic techniques based on a particle swarm algorithm. This approach provides an efficient method to estimate system parameters that otherwise are difficult or impossible to determine with independent measurements. The experimental results demonstrate agreement with the theoretical predictions over a limited bandwidth. The sensor can effectively harvest non-stationary vibration energy down to 10 -4 g within a limited bandwidth of 130–150 Hz. The sensor prototype has an operational volume of 2.6 cm 3 with a calculated power density of 0.2 W/cm 3 . The sensor’s small size results in a coupling efficiency of approximately 6% across the tested bandwidth.

42 ENGINEERING↗

Advanced Intensity-Modulation Continuous-Wave Lidar Techniques for ASCENDS O2 Column Measurements

Global atmospheric carbon dioxide (CO2) measurements for the NASA Active Sensing of CO2 Emissions over Nights, Days, and Seasons (ASCENDS) space mission are critical for improving our understanding of global CO2 sources and sinks. Advanced Intensity- Modulated Continuous-Wave (IM-CW) lidar techniques are investigated as a means of facilitating CO2 measurements from space to meet the ASCENDS measurement requirements. In recent numerical, laboratory and flight experiments we have successfully used the Binary Phase Shift Keying (BPSK) modulation technique to uniquely discriminate surface lidar returns from intermediate aerosol and cloud contamination. We demonstrate the utility of BPSK to eliminate sidelobes in the range profile as a means of making Integrated Path Differential Absorption (IPDA) column CO2 measurements in the presence of optically thin clouds, thereby eliminating the need to correct for sidelobe bias errors caused by the clouds. Furthermore, high accuracy and precision ranging to the surface as well as to the top of intermediate cloud layers, which is a requirement for the inversion of column CO2 number density measurements to column CO2 mixing ratios, has been demonstrated using new hyperfine interpolation techniques that takes advantage of the periodicity of the modulation waveforms. This approach works well for both BPSK and linear swept-frequency modulation techniques. The BPSK technique under investigation has excellent auto-correlation properties while possessing a finite bandwidth. A comparison of BPSK and linear swept-frequency is also discussed in this paper. These results are extended to include Richardson-Lucy deconvolution techniques to extend the resolution of the lidar beyond that implied by limit of the bandwidth of the modulation, where it is shown useful for making tree canopy measurements.

Campbell, Joel F.↗

Calibration of the Oscillating Screen Viscometer

We have devised a calibration procedure for the oscillating screen viscometer which can provide the accuracy needed for the flight measurement of viscosity near the liquid-vapor critical point of xenon. The procedure, which makes use of the viscometer's wide bandwidth and hydrodynamic similarity, allows the viscometer to be self-calibrating. To demonstrate the validity of this procedure we measured the oscillator's transfer function under a wide variety of conditions. We obtained data using CO2 at temperatures spanning a temperature range of 35 K and densities varying by a factor of 165, thereby encountering viscosity variations as great as 50%. In contrast the flight experiment will be performed over a temperature range of 29 K and at only a single density, and the viscosity is expected to change by less than 40%. The measurements show that, after excluding data above 10 Hz (where frequency-dependent corrections are poorly modeled) and making a plausible adjustment to the viscosity value used at high density, the viscometer's behavior is fully consistent with the use of hydrodynamic similarity for calibration. Achieving this agreement required understanding a 1% anelastic effect present in the oscillator's torsion fiber.

Berg, Robert F.↗

Large Bandwidth and Low Noise in a Diffusion-Cooled Hot-Electron Bolometer Mixer

Heterodyne measurements have been made at 533 GHz using a novel superconducting hot-electron bolometer in a waveguide mixer. The bolometer is a 0.3 micrometer long niobium microbridge with a superconducting transition temperature of 5 K. The short length ensures that electron diffusion dominates over electron-phonon interactions as the electron cooling mechanism, which should allow heterodyne detection with intermediate frequencies (if) of several GHz. A Y-factor response of 1.15 dB has been obtained at an if of 1.4 GHz with 77 and 295 K loads, indicating a receiver noise temperature of 650 K DSB. The -3 dB rolloff in the if response occurs at 1.7 GHz.

Skalare, A.↗

Propagation experiments at Virginia Tech with the Olympus satellite

A major propagation experiment is in progress to measure atmospheric attenuation at 12, 20, and 30 GHz using the beacons of the Olympus satellite. The experiment uses a frequency-locked receiver system which locks to the 12-GHz beacon frequency and measures the signal strength of the coherent 20- and 30-GHz beacons in a 3-Hz bandwidth. The receiving system is augmented with radiometers in each beacon frequency band to set the clear-air attenuation levels of the beacon signals. Olympus propagation experiment objectives and the measurement system are described. Results from the measurement program will include fade statistics at all frequencies, attenuation scaling between frequencies, short baseline site diversity, and fade dynamics.

Pratt, T.↗

Quantitative non-destructive evaluation of porous composite materials based on ultrasonic wave propagation

Two complementary ultrasonic techniques for characterizing porosity in fiber-reinforced composite laminates are evaluated. Five uniaxial graphite-fiber/epoxy-matrix composites having a range of 1 to 8 percent volume fraction of solid glass inclusions to model porosity were investigated. In one technique, signal loss was measured in transmission mode and slope of attenuation, obtained from the first order coefficient of a two-parameter polynomial fit about the center frequency of the useful bandwidth, was used as the ultrasonic parameter to characterize the porosity. The results of these transmission mode measurements displayed a good correlation between the volume fraction of porosity and the slope of attenuation. Integrated polar backscatter was used as a second ultrasonic parameter for the characterization of the porosity in these samples. A single transducer insonified the samples and measured the resulting backscatter at a polar angle of 30 deg with respect to the normal of the sample surface with the azimuthal angles centered at 0 deg with respect to the fiber orientation (i.e., along the fibers). Integrated polar backscatter also displayed good correlation with the volume fraction of porosity.

Miller, James G.↗

Diagnosis Of A Pressure-Modulator-Radiometer Cell

Spectral response of pressure-modulator-radiometer cell measured with help of lead-salt tunable diode laser. Laser chosen because of narrow bandwidths {2 x 10 to negative 4th power (cm) to negative 1st power} and relatively high powers (up to 1 mW continuous) of such lasers and because available for wavelengths from 3 to 30 micrometers. Direct measurement of spectral response enables formulation of more-precise atmospheric-transmission functions, enabling extraction of better information from readings taken with instrument.

May, Randy D.↗

Conductive Spray Paint Fabricated Cylindrical Coplanar Waveguide for Noncontact Liquid-Level Sensing

A noncontact liquid-level sensor using a cylindrical coplanar waveguide (CCPW) is proposed. The concept is demonstrated using a prototype device made by directly spraying conductive paint on the outer surface of a glass cylinder. The position of the air–liquid interface is measured using the time-domain reflection (TDR) signal from the CCPW. The geometric parameters of the prototype sensor were optimized using a full-wave simulation tool. The experimental results show that the prototype CCPW-based liquid-level sensor has a resolution of 29.8μm over a range of 210 mm at the sweeping frequency bandwidth of 500 MHz–4 GHz. The tradeoff between the resolution and the measurement range was discussed. The proposed sensor provides a low-cost, easy-to-fabricate, and noncontact method for liquid-level measurement, which has potential applications in fuel storage, chemical production, and wastewater treatment.

42 ENGINEERING↗

Pseudorandom noise for telemetry error rate measurement applications and limitations.

A pseudorandom noise (PRN) generator functional design has been developed which is superior to the commercially available instrument in usable bandwidth and in the closeness of fit to the gaussian probability distribution in the 'tails' of the curve. The principal disadvantage of PRN sources for bit error rate (BER) measurements is that the probability distribution is truncated in the tails. This truncation of the probability distribution results in a similar truncation of the BER curve - i.e., there is a minimum BER which can be measured, below which the only possible result is zero. The minimum nonzero BER actually computed with the PRN source developed was 0.00001 with a pseudorandom sequence of 131,071 bits. It is theoretically possible, with a longer sequence, to achieve a minimum BER of 0.000001 with the same design.

Hopkins, P. M.↗

Evaluating the Uncertainties in the Electron Temperature and Radial Speed Measurements Using White Light Corona Eclipse Observations

We examine the uncertainties in two plasma parameters from their true values in a simulated asymmetric corona. We use the Corona Heliosphere (CORHEL) and Magnetohydrodynamics Around the Sphere (MAS) models in the Community Coordinated Modeling Center (CCMC) to investigate the differences between an assumed symmetric corona and a more realistic, asymmetric one. We were able to predict the electron temperatures and electron bulk flow speeds to within +/-0.5 MK and +/-100 km s(exp−1), respectively, over coronal heights up to 5.0 R from Sun center.We believe that this technique could be incorporated in next-generation white-light coronagraphs to determine these electron plasma parameters in the low solar corona. We have conducted experiments in the past during total solar eclipses to measure the thermal electron temperature and the electron bulk flow speed in the radial direction in the low solar corona. These measurements were made at different altitudes and latitudes in the low solar corona by measuring the shape of the K-coronal spectra between 350 nm and 450 nm and two brightness ratios through filters centered at 385.0 nm/410.0 nm and 398.7 nm/423.3 nm with a bandwidth of is approximately equal to 4 nm. Based on symmetric coronal models used for these measurements, the two measured plasma parameters were expected to represent those values at the points where the lines of sight intersected the plane of the solar limb.

corona↗

A Vision of Quantitative Imaging Technology for Validation of Advanced Flight Technologies

Flight-testing is traditionally an expensive but critical element in the development and ultimate validation and certification of technologies destined for future operational capabilities. Measurements obtained in relevant flight environments also provide unique opportunities to observe flow phenomenon that are often beyond the capabilities of ground testing facilities and computational tools to simulate or duplicate. However, the challenges of minimizing vehicle weight and internal complexity as well as instrumentation bandwidth limitations often restrict the ability to make high-density, in-situ measurements with discrete sensors. Remote imaging offers a potential opportunity to noninvasively obtain such flight data in a complementary fashion. The NASA Hypersonic Thermodynamic Infrared Measurements Project has demonstrated such a capability to obtain calibrated thermal imagery on a hypersonic vehicle in flight. Through the application of existing and accessible technologies, the acreage surface temperature of the Shuttle lower surface was measured during reentry. Future hypersonic cruise vehicles, launcher configurations and reentry vehicles will, however, challenge current remote imaging capability. As NASA embarks on the design and deployment of a new Space Launch System architecture for access beyond earth orbit (and the commercial sector focused on low earth orbit), an opportunity exists to implement an imagery system and its supporting infrastructure that provides sufficient flexibility to incorporate changing technology to address the future needs of the flight test community. A long term vision is offered that supports the application of advanced multi-waveband sensing technology to aid in the development of future aerospace systems and critical technologies to enable highly responsive vehicle operations across the aerospace continuum, spanning launch, reusable space access and global reach. Motivations for development of an Agency level imagery-based measurement capability to support cross cutting applications that span the Agency mission directorates as well as meeting potential needs of the commercial sector and national interests of the Intelligence, Surveillance and Reconnaissance community are explored. A recommendation is made for an assessment study to baseline current imaging technology including the identification of future mission requirements. Development of requirements fostered by the applications suggested in this paper would be used to identify technology gaps and direct roadmapping for implementation of an affordable and sustainable next generation sensor/platform system.

Horvath, Thomas J.↗

Coherence bandwidth loss in transionospheric radio propagation

In this report a theoretical model is developed that predicts the single-point, two-frequency coherence function for transionospheric radio waves. The theoretical model is compared to measured complex frequency correlation coefficients using data from the seven equispaced, phase-coherent UHF signals transmitted by the Wideband satellite. The theory and data are in excellent agreement. The theory is critically dependent upon the power-law index, and the frequency coherence data clearly favor the comparatively small spectral indices that have been consistently measured from the wideband satellite phase data. A model for estimating the pulse delay jitter induced by the coherence bandwidth loss is also developed and compared with the actual delay jitter observed on synthesized pulses obtained from the Wideband UFH comb. The results are in good agreement with the theory. The results presented in this report, which are based on an asymptotic theory, are compared with the more commonly used quadratic theory. The model developed and validated in this report can be used to predict the effects of coherence bandwidth loss in disturbed nuclear environments. Simple formulas for the resultant pulse delay jitter are derived that can be used in predictive codes.

Rino, C. L.↗

The Dielectric Constant at P-Band for Salinity from 0 to 150 pss

Measurements have been made at P-band (0.707 GHz) to construct a model for the dielectric constant of sea water and extend the model for the dielectric constant to high salinity (50-150 pss). The measurements are part of research to develop a model for the dielectric constant suitable for future wide-bandwidth remote sensing of salinity and for application to water bodies such as the Great Salt Lake with salinity significantly above that found in the open ocean. Measurements have been made at temperatures from 2 to 30 °C and salinity from 0 to 138 pss. The data have been fit to a Debye model for the dielectric constant with a single resonance as has been employed at L-band (1.413 GHz) where remote sensing of salinity is currently done. Comparison with contemporary models developed from data at L-band indicates that the L-band model and new P-band model do well at both frequencies for salinity less than 50 pss but at higher values of salinity the L-band models diverge from the data. The data has also been used to test at high salinity the mathematical relationship between salinity and conductivity which is the basis for the practical salinity scale (pss).

Dielectric Constant↗

Highly efficient visible and near-IR photon pair generation with thin-film lithium niobate

Efficient on-chip entangled photon pair generation at telecom wavelengths is an integral aspect of emerging quantum optical technologies, particularly for quantum communication and computing. However, moving to shorter wavelengths enables the use of more accessible silicon detector technology, and opens up applications in imaging and spectroscopy. Here, we present high brightness ((1.6 ± 0.3) × 10 9 pairs/s/mW/nm) visible–near-IR photon pair generation in a periodically poled lithium niobate nanophotonic waveguide. The degenerate spectrum of the photon pairs is centered at 811 nm with a bandwidth of 117 nm when pumped with a spectrally multimode laser diode. The measured on-chip source efficiency of (2.3 ± 0.5) × 10 11 pairs/s/mW is on par with source efficiencies at telecom wavelengths and is also orders of magnitude higher than the efficiencies of other visible sources implemented in bulk crystal or diffused waveguide-based technologies. Further improvements in the brightness and efficiencies are possible by pumping the device with a single-frequency laser, which would also shrink the pair bandwidth. These results represent the shortest wavelength of photon pairs generated in a nanophotonic waveguide reported to date by nearly an octave.

42 ENGINEERING↗

Chemical Detection using Electrically Open Circuits having no Electrical Connections

This paper presents investigations to date on chemical detection using a recently developed method for designing, powering and interrogating sensors as electrically open circuits having no electrical connections. In lieu of having each sensor from a closed circuit with multiple electrically connected components, an electrically conductive geometric pattern that is powered using oscillating magnetic fields and capable of storing an electric field and a magnetic field without the need of a closed circuit or electrical connections is used. When electrically active, the patterns respond with their own magnetic field whose frequency, amplitude and bandwidth can be correlated with the magnitude of the physical quantities being measured. Preliminary experimental results of using two different detection approaches will be presented. In one method, a thin film of a reactant is deposited on the surface of the open-circuit sensor. Exposure to a specific targeted reactant shifts the resonant frequency of the sensor. In the second method, a coating of conductive material is placed on a thin non-conductive plastic sheet that is placed over the surface of the sensor. There is no physical contact between the sensor and the electrically conductive material. When the conductive material is exposed to a targeted reactant, a chemical reaction occurs that renders the material non-conductive. The change in the material s electrical resistance within the magnetic field of the sensor alters the sensor s response bandwidth and amplitude, allowing detection of the reaction without having the reactants in physical contact with the sensor.

Woodward, Stanley E.↗

Hyperspectral X-ray Imaging: Progress Towards Chemical Analysis in the SEM

The Hyperspectral X-ray Imaging (HXI) project will enable non-destructive chemical-state determination of nano-scale samples in the electron microscope for nuclear safeguards applications. To efficiently measure chemical state through electron-excited X-ray emission requires a combination of wide spectral bandwidth, high resolution, and high count rate capability. We are building a next-generation X-ray detector based on an array of transition edge sensors (TESs) to make these measurements possible and routine in the scanning electron microscope (SEM). Leveraging the large pixel densities afforded by microwave multiplexing readout and continuous, uninterrupted operation of a cryogen-free dilution refrigerator, this instrument will have efficiency to allow chemical species identification of nano-scale samples in hours instead of days to weeks. We describe prototype pixel designs for this HXI instrument, comprising three pixel types that will make up the hybrid TES array. Engineering design of the integrated HXI cryostat and SEM system is in progress, with full detector commissioning expected in Spring 2021 followed closely by full-scale integration with the SEM. Furthermore, we also report on the commissioning of a complementary TES-based X-ray emission spectroscopy platform for bulk samples to build a spectral library for HXI sample identification.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Comparison of carrier localization effects between InAs quantum dashes and quantum dots in a DWELL (dashes- or dots-in-a-well) configuration

The optical properties of InAs quantum dashes (QDashes) grown on InP and InAs quantum dots (QDots) grown on GaAs in a dashes- or dots-in-a-well (DWELL) configuration are comparatively investigated using temperature-dependent photoluminescence (PL) measurements. The trends in PL characteristics such as exciton energy, spectral bandwidth and integrated intensity with respect to temperature are found to be distinctly dissimilar between the two systems. A rate-equation model involving exciton recombination and thermal transfer in a localized-state ensemble is used to quantitively interpret the experimental data. The results of this study suggest that QDashes in this configuration exhibit PL properties more consistent with a lower degree of carrier localization compared to QDots. A preliminary structural analysis highlighting the shape/size differences between the two nanostructures is also presented.

carrier localization↗