Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “load monitoring”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Rapid denitrification of nitrate-contaminated groundwater in a low-gradient blackwater stream valley

Leaching of excess nitrogen (N) to groundwater in fertilized landscapes can overwhelm natural biogeochemical processes and cause long-term eutrophication of aquatic systems. We investigated N fate and transport from an intensively managed short-rotation woody crop (Pinus taeda) plantation through the riparian zone of an intermittent, low-gradient blackwater stream. Fertilization of the P. taeda plantation on the uplands resulted in contamination of groundwater with nitrate concentrations between 0.9 and 1.9 mg N L -1 . No corresponding increase in nitrate was observed in stream water or shallow groundwater in the riparian zone. Groundwater travel-time modeling predicted that N from near-stream, upland plantation areas should have reached streams during the monitoring period. Two years of measuring N species in well water in contrasting landscape positions (within the plantation, swale, riparian edge, forested hillslope, and valley), indicated rapid nitrate transformation and denitrification within the forested wetland valleys. Denitrification in the shallow groundwater system within the toeslopes and the riparian zone was estimated to have removed > 90% of nitrate. Finally, these results highlight the importance of riparian zones as pathways for the removal of N and for controlling downstream N loads.

54 ENVIRONMENTAL SCIENCES↗

Leak detection in a subcritical boiler

Thermal power plants experience cycling duty leading to the fatigue of the boiler and heat exchanger tubes. As a result, tube failures occur frequently in coal fired fleets leading to forced outages. Furthermore, because the tube leaks have been the major source of unwanted shutdowns and the number of outages is increasing, present work focuses on the detection and isolation of the leak in a subcritical boiler based upon the process data from a commercial coalfired power plant. The mass balance equation around the steam drum was analyzed using timeseries data collected from a 300 MW power plant. The ratio of the feed water mass flow rate to the steam mass flow rate was defined as a key parameter for detecting leaks. The difference in slope between the feedwater and steam mass flow rate during the normal and faulty operations was established as the upper control limit for real time monitoring. To reduce false alarm rates that arise when raw signal is directly compared against the threshold due to common process fluctuations, an optimal filter was derived for smoothing. It was found that the optimal filter reacted much more quickly to process changes than an exponential moving average filter, around 8 h earlier on average. Occurrence of relatively high false alarm rates even in the filtered responses was related to the cycling of the boiler from the base load condition. Variable threshold was established to keep false alarm rates to the minimum while maintaining the leak detection rate. Finally, the leak was located at the economizer and this could readily be isolated by investigating the magnitude of the mass flow rates ratio and the temperature at the economizer outlet.

42 ENGINEERING↗

Comparative Analysis of ML Techniques for Data-Driven Anomaly Detection, Classification and Localization in Distribution System

High penetration of Distributed Energy Resources (DERs), fundamental load behavior changes, controllable loads, and significant increase in Electrical Vehicles (EVs) lead to complex dynamic behavior of the electric distribution system. Increasing number of components also means more measurements, more data and more data anomalies. Detecting, classifying and localizing these anomalies are important for situational awareness, and at the same time, very challenging given increasing complexity of the system. Highly accurate and high-resolution analytical techniques are needed to support anomaly detection, classification and localization (AD-C-L) for monitoring, root cause analysis and decision making. This paper provides comprehensive review and analysis of the existing spatio-temporal AD-C-L techniques within the distribution system. Challenges for specific problems in AD-C- L have been also discussed in this paper. Existing AD-C- L techniques have been categorized and synthesized for specific merits and limitations of multiple Machine Learning (ML) methodologies using common developed metrics of performance. The comparative analysis is summarized and presented with the open research challenges and path forward for future research needs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Additive Manufacturing of Controlled Porous Elastomeric Nanocomposites for Enhanced Sensing Function

Sensors manufactured using piezoresistive elastomeric nanocomposites have a wide range of applications in many fields such as structural health monitoring, robotics, and biomedical industries. Additive manufacturing of these sensors, achieved using Direct Ink Writing (DIW), has provided numerous advantages including increased sensitivity and the fabrication of complex geometry. However, solid sensors manufactured either additively or using conventional methods, display a greater level of hysteresis, especially at strains higher than 10%, which limits their sensitivity. The solid sensors also display a greater level of piezoresistive relaxation where the resistance change with time either in a static or dynamic loading environment. Porosity can be introduced in the form of varying infill patterns and densities to reduce bulk material effects. In this paper, a lattice structure with four infill densities are investigated, and the samples are printed using a grid infill pattern. The fabricated samples are characterized using a scanning electron microscope (SEM) to validate the microstructural features and layer bonding. The pressure-sensing capability of each sensor is investigated using cyclic compression loading at various strain levels. Sensing results show that an increase in sensitivity, as well as a decrease in hysteresis with an increase in porosity, compared to solid samples (100% in-fill). The highest porosity was measured to be 62.3% with a corresponding 112% increase in the gauge factor compared to the solid bulk. These results indicate that introducing porosity using DIW is a sensible strategy to improve the piezoresistive performance of nanocomposites and to allow for the tunability of sensing capacity in pressure sensors

Sukati, Musa↗

3D printed graphene-based self-powered strain sensors for smart tires in autonomous vehicles

The transition of autonomous vehicles into fleets requires an advanced control system design that relies on continuous feedback from the tires. Smart tires enable continuous monitoring of dynamic parameters by combining strain sensing with traditional tire functions. Here, we provide breakthrough in this direction by demonstrating tire-integrated system that combines direct mask-less 3D printed strain gauges, flexible piezoelectric energy harvester for powering the sensors and secure wireless data transfer electronics, and machine learning for predictive data analysis. Ink of graphene based material was designed to directly print strain sensor for measuring tire-road interactions under varying driving speeds, normal load, and tire pressure. A secure wireless data transfer hardware powered by a piezoelectric patch is implemented to demonstrate self-powered sensing and wireless communication capability. Combined, this study significantly advances the design and fabrication of cost-effective smart tires by demonstrating practical self-powered wireless strain sensing capability.

33 ADVANCED PROPULSION SYSTEMS↗

Baselining Activity and Stability of ORR Catalysts and Electrodes for Proton Exchange Membrane Fuel Cells for Heavy-Duty Applications

Activity and stability of electrodes with Pt and PtCo alloy catalysts supported on high surface area carbon, hereafter to as a-Pt/C and d-PtCo/C, were evaluated for heavy-duty applications. Both catalysts had nearly identical Pt loading (50-wt% Pt on carbon and 0.25 mg Pt cm −2 ) and had undergone thermal treatment to stabilize them by growing the average particle size to 4–5 nm. Both were subjected to 90,000 (90 k) standard accelerated stress tests (AST) cycles consisting of 0.6–0.95 V square wave potentials, 3-s hold at upper and lower potential limits in H 2 /N 2 at 1.5 atm, 80 °C and 100% RH. Test protocols were developed to monitor the performance losses and characterize them in terms of activity for the oxygen reduction reaction (ORR), oxygen transport in the electrode and proton transport in the membrane and cathode catalyst layer. Despite the nearly double initial ORR activity, the PtCo/C electrode degraded faster due to the leaching of Co from the catalyst that had started even before the imposition of the AST potential cycles. Commensurate with Co leaching, Co poisoning of ionomer is responsible for the inferior performance of d-PtCo/C electrode at high current densities both before and after AST.

30 DIRECT ENERGY CONVERSION↗

Quantitative Effects of Disorder on Chemically Modified Amorphous Carbon Electrodes

Real materials are disordered. This disorder influences the properties of these materials and the chemical processes that occur at their interfaces. Gaining a molecular-level understanding of the underlying physical manifestations caused by disordered materials is crucial to unraveling and ultimately controlling the efficiency and performance of these materials in a range of energy-related devices. This understanding necessitates measurement techniques through which disorder can be detected, quantified, and monitored. However, such quantitative measurements are notoriously difficult, as effects often average out in ensemble measurements. In this work, we describe how a combination of electrochemical and spatially resolved surface spectroscopy measurements illuminate a molecular-level picture of disorder in materials. Using amorphous carbon as an intrinsically disordered material, we covalently attached a monolayer of ferrocene. Interfacial electron transfer across the amorphous carbon–ferrocene interface is highly sensitive to disruptions of order. Here, by systematically varying linker properties and surface loadings, the influence of lateral interactions between nonuniformly distributed ferrocene headgroups on ensemble electrochemical measurements is demonstrated. Electrochemical and imaging data collectively indicate that conformational flexibility of the ferrocene moieties provides a mechanism to elude repulsive and unbalanced lateral interactions, while rigid linkages provide direct information about the underlying disorder of the material. This study is the first of its kind to quantify and visualize molecular disorder and heterogeneity with an experimental model accessed through ensemble measurements.

36 MATERIALS SCIENCE↗

Anomaly Detection, Localization and Classification using Drifting Synchrophasor Data Streams

With ongoing automation and digitization of the electric power system, several Phasor Measurement Units(PMUs) have been deployed for monitoring and control. PMU data can have multiple anomalies, and many of the researchers in the past have concentrated on training machine/deep learning algorithms offline for anomaly detection over PMU data (i.e., not in real time). These machine/deep learning algorithms, when trained offline on a sample rather than a population of the dataset, fail to consider the dynamic behavior of the power grid in real-time, resulting in low accuracy. Considering the dynamic behavior of the power grid (e.g., change in load, generation, distributed energy resources (DERs) switching, network, controls), the definition of data anomalies varies in time and requires online training. A fundamental challenge is to enable online (i.e., real-time) training of machine/deep learning algorithms for anomaly detection over streaming PMU data. While machine/deep learning is often desirable to manage data streams, training a deep learning algorithm over streaming PMU data is nontrivial due to changes in data statistics caused by dynamic streaming data. This paper proposes PMUNET: a novel device-level deep learning-based data-driven approach for anomaly detection, localization, and classification over streaming PMU data, using online learning and multivariate data-drift detection algorithm .Two variants of PMUNET, Dynamic data Change Driven Learning (DCDL) and Continuity Driven Learning (CDL), are proposed and compared. DCDL aims to train the deep learning algorithm whenever the definition of anomaly changes due to the power grid dynamics. On the other hand, CDL continuously trains the deep learning algorithm over the PMU data-stream. The experimental results verify that DCDL outperforms CDL and other efficient anomaly detection methods over multiple events such as faults and load/ generator/capacitor/DERs variations/switching for IEEE 14 and 39 Bus test system as well as real PMU industrial data. The result verifies that DCDL variant of PMUNET improves over existing approach with a gain of 2% - 10% in terms of accuracy, false-positive rate, and false-negative rate.

adversarial deep learning↗

Mitigating Moisture with High-R Walls

Energy-efficient building enclosures are key to decreasing energy load demand and enabling advanced space-conditioning systems for high-performance homes. One efficient enclosure design solution is high-R walls, which feature increased insulation levels as an effective solution for reducing air leakage and permeance of material layers. To increase builder confidence and encourage greater market adoption of high-R walls, Home Innovation Research Labs sought to demonstrate the long-term moisture performance of several high-R wall configurations in cold climate zones. The team monitored 22 newly constructed, occupied homes located throughout climate zones 4–7, where a substantial vapor drive to the exterior is present during the winter.

buildings↗

Expansion of the Fuel Motion Monitoring System

The Idaho National Laboratory (INL) Transient Reactor Test Facility (TREAT) Fuel Motion Monitoring System (FMMS) is a diagnostic tool used to visualize the movement and location of fuel within the nuclear reactor during transient experiments. TREAT is designed to test the behavior of nuclear fuel under accident conditions, such as a rapid power increase. The TREAT FMMS, also referred to as the “hodoscope” because of the system’s massive steel collimator component, is located on the North beam port of the reactor. While the FMMS system is capable of incorporating a total of 360 sensors, initial refurbishment efforts resulted in a array of 96 fast neutron detectors. This initial array was configured to provide a narrow (2 channels) full-length view of experiment vessels with an extended 4-channel–wide region in the center of the array capable of providing a full view of all initially planned experiments. Planning and efforts to expand the FMMS array began immediately following the restart of TREAT. An additional 96 detectors were evaluated, characterized, and prepared for installation at TREAT during the summer of 2018. Unfortunately, funding reductions forced the project towards a 5-year hiatus. In October of 2023 funding from the Department of Energy’s Nuclear Science User Facilities enabled the expansion to recommence. This report serves to document the activities performed to expand the FMMS detector array to 192 channels in order to provide a broader view of the larger and more sophisticated test capsules currently planned for future irradiation in the TREAT reactor. This expansion also included doubling the data acquisition capability, addressing the new heat load on the system, and synchronizing the time for all digital components.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Grid-connected heat pump water heater benefits for low-income households in the Southeastern United States

Energy efficient heat pump water heaters (HPWHs) reduce customer energy costs; grid-connected controls further increase HPWH value by enabling energy storage and shifting demand to cheaper, off-peak periods. However, a HPWH’s first cost premium can put it out of reach for low-income customers. This paper will present results of an ongoing study exploring the benefits of load shifting HPWHs for 24 low-income households, aiming to support increased product deployment in this demographic. The study uses EcoPort modules to shift HPWH load for a study sample consisting primarily of low-income adults and seniors in North Carolina. Building upon prior studies, the study’s HPWH operating schedules are designed to maximize shifted energy and minimize participant electricity costs based on local time-of-use rates. The study documents load profiles of grid-connected HPWHs in a less-studied demographic group and explores how certain groups may have particularly flexible loads due to their unique usage profiles. The results are relevant for HPWH product performance in the Southeast. The study will quantify HPWH load shifting performance during North Carolina’s hot summer, temperate shoulder, and occasionally sub-freezing winter seasons, and the study includes installations in conditioned, semi-conditioned, and unconditioned spaces. Finally, study results will also explore how controlled HPWHs can provide value to the regional grid by reducing seasonal peaks via demand response. Lessons learned include HPWH acceptance for low-income and senior users, best practices for maintaining HPWH connectivity among users without prior product experience, and strategies to leverage remote monitoring to ensure optimal operation and enhance HPWH reliability.

Urigwe, Daniela↗

Instrumented Photovoltaic Modules for Environmental Characterization and Simulation Model Validation

Photovoltaic modules are subjected to various mechanical stressors in their deployment environments, ranging from installation handling to wind and snow loads. Damage incurred during these mechanical events has the potential to initiate subsequent degradation mechanisms, reducing useful module lifespan. Thus, characterizing the mechanical state of photovoltaic modules is pertinent to the development of reliable packaging designs. In this work, photovoltaic modules with strain gauges directly incorporated into the module laminate were fabricated and subjected to mechanical loading to characterize internal strains within the module when under load. These experimental measurements were then compared against results obtained by high-fidelity finite-element simulations. The simulation results showed reasonable agreement in the strain values over time; however, there were large discrepancies in the magnitudes of these strains. Both the instrumentation technique and the finite-element simulations have areas where they can improve. These areas of improvement have been documented. Despite the observed discrepancies between the experimental and simulated results, the module instrumentation proved to be a useful gauge in monitoring and characterizing the mechanical state. With some process improvements, this method could potentially be applied to other environments that a photovoltaic module will encounter in its lifetime that are known to cause damage and degrade performance.

14 SOLAR ENERGY↗

COnfirmation using Gamma-ray Non-Imaging Zero-knowledge ANti-mask Time-encoding (COGNIZANT) Final Summary Report

In potential future arms reduction treaties in which the numbers of nuclear warheads may approach small numbers, using delivery systems as a proxy for the warheads themselves may be insufficient. Therefore, a technical means of verifying the presence of a nuclear warhead may become necessary. Verifying that a declared item actually is a warhead is technically challenging within a verification regime: providing assurance to the monitoring party that a presented item is a warhead while protecting sensitive information about that warhead may be required. It is generally believed that strong assurance will require the confirmation of key attributes that may reveal closely-guarded critical design information. This provides high confidence to the monitoring party, but presents a risk of information loss to the host. A verification system must overcome this hurdle. Over the last several decades, systems have been developed that balance host and monitoring partner needs by using sensitive information to confirm treaty accountable items (TAI) as warheads while sequestering that information behind an information barrier (1). These are designed to meet the needs of the host but places the onus on the monitor to authenticate the hardware, firmware, and software. Authentication requires that the monitor confirm that all components of the system have not been modified and work as intended. In 2014, Glaser et al. proposed applying the concept of “zero knowledge protocols” (ZKP) from the field of cryptography to the problem of warhead verification (2). In mathematical cryptography, ZKP is accomplished by challenging one party to solve a problem that is only possible if that party possesses the information being authenticated. After repeated challenges, the party provides confidence that it possesses this information without revealing any details about the information itself. Systems have been in development based on this idea at both Princeton and MIT (2) (3) (4). The final measurement results produced by these systems can be viewed by both the host and the monitoring party without the worry of revealing sensitive information. However, in both of these physical implementations, there remains an information barrier within the system. The need for a digital information barrier to protect a measurement result is eliminated, but it has been replaced with the need to sequester physical components of the system, potentially obfuscating the measurement process itself. Both implementations physically insert information into the system that requires protection to prevent undesired disclosure of sensitive information: in the Princeton method, one must physically load the complement of the expected image of a true warhead into the system, and in the MIT technique, one loads a collection of spectator foils whose thicknesses physically encrypt a measured spectrum. This complicates authentication of the hardware and measurement process. The CONFIDANTE/COGNIZANT concept developed in this project do not load sensitive information into the system at any time, and could therefore open the possibility of allowing the inspector to not only view the final data but also the measurement as it is being performed and all associated equipment.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Smarter building start – A distributed solution

A significant focus of research and new technologies for reducing energy use in buildings is on operating the systems more efficiently during the times when the systems are active. However, there is a large potential for energy savings in determining the periods when the systems should or should not be active. This scheduling aspect of operation is often overlooked even though relatively simple solutions can unlock substantial energy savings. In this paper we describe a smart building start (SBS) algorithm that considers multiple zones in a building to determine individual schedules for room controllers as well as the central systems based on solving a simple optimization problem. Application of the SBS algorithm to multiple interconnected systems enables a staggered start-up that minimizes peak loads and also ensures comfort is within a target range with minimal system run time. The SBS algorithm extends the capability of traditional optimal start and is designed to be simple to deploy and robust. Simulation results as well as results from tests in a real building with a VAV system are presented. The presented algorithm is applicable to any type of building with a zonal or multi-zone HVAC system. To function, it needs to be able to change setpoints in rooms and monitor room temperatures, as well as, if desired, turn the central system on or off.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Performance Considerations for Ground Source Heat Pumps in Cold Climates: Preprint

Remote, cold climates present challenges to finding safe and affordable options to heat homes. In Alaska, residential ground source heat pumps (GSHPs) have been gaining in popularity to fill this gap. However, there is little research on their long-term performance or effect on soil temperatures. The extended heating season and cold soils of Alaska provide a harsh testing ground for GSHPs, even those designed and marketed for colder climates. The large and unbalanced heating load of cold climates creates a challenging environment for GSHPs. In 2013 the Cold Climate Housing Research Center (CCHRC) installed a GSHP at its Research and Testing Facility (RTF) in Fairbanks, Alaska. The heat pump replaced an oil-fired condensing boiler heating a 464 m2 office space via an in-floor hydronic radiant heating system. The ground heat exchanger (GHE) was installed in moisture-rich silty soils underlain with permafrost near 0°C. The intent of the installation was to observe and monitor the system over a 10-year period in order to develop a better understanding of the performance of GSHPs in sites with permafrost and to help inform future design. As of this writing, the heat pump system has been running for seven heating seasons. The efficiency in those seven heating seasons has been variable with ups and downs that have been difficult to explain. This paper seeks to understand the variability in performance as well as make recommendations for GSHP use in other cold climates.

cold climate↗

Acoustic force spectroscopy reveals subtle differences in cellulose unbinding behavior of carbohydrate-binding modules

Protein adsorption to solid carbohydrate interfaces is critical to many biological processes, particularly in biomass deconstruction. To engineer more-efficient enzymes for biomass deconstruction into sugars, it is necessary to characterize the complex protein–carbohydrate interfacial interactions. A carbohydrate-binding module (CBM) is often associated with microbial surface-tethered cellulosomes or secreted cellulase enzymes to enhance substrate accessibility. However, it is not well known how CBMs recognize, bind, and dissociate from polysaccharides to facilitate efficient cellulolytic activity, due to the lack of mechanistic understanding and a suitable toolkit to study CBM–substrate interactions. Our work outlines a general approach to study the unbinding behavior of CBMs from polysaccharide surfaces using a highly multiplexed single-molecule force spectroscopy assay. Here, we apply acoustic force spectroscopy (AFS) to probe a Clostridium thermocellum cellulosomal scaffoldin protein (CBM3a) and measure its dissociation from nanocellulose surfaces at physiologically relevant, low force loading rates. An automated microfluidic setup and method for uniform deposition of insoluble polysaccharides on the AFS chip surfaces are demonstrated. The rupture forces of wild-type CBM3a, and its Y67A mutant, unbinding from nanocellulose surfaces suggests distinct multimodal CBM binding conformations, with structural mechanisms further explored using molecular dynamics simulations. Applying classical dynamic force spectroscopy theory, the single-molecule unbinding rate at zero force is extrapolated and found to agree with bulk equilibrium unbinding rates estimated independently using quartz crystal microbalance with dissipation monitoring. However, our results also highlight critical limitations of applying classical theory to explain the highly multivalent binding interactions for cellulose–CBM bond rupture forces exceeding 15 pN.

09 BIOMASS FUELS↗

Control approach for power modulation of end-use loads

Methods, apparatus, and systems are disclosed herein for power modulation control of power grids using end-use loads. At the beginning of a coordination period typically lasting a few minutes, a population of end-use loads (water heaters, air conditioners, plug-in electric vehicles, etc.) is interrogated for their willingness to participate in power modulation by undergoing state transitions from on to off, or off to on. Distribution system flexibilities are calculated from the sums of device powers within distribution systems. Area flexibilities are calculated from the sums of device powers within areas. Thresholds for various devices to change state in response to inter-area oscillation damping or frequency regulation are derived from these flexibilities. Two power functions are monitored in real-time and compared with the device thresholds to trigger state changes which then remain locked throughout the remainder of the coordination period, then the devices are released from the lockout state.

Lian, Jianming↗

Nondestructive Evaluation of Rexolite Insulators for the Purpose of Monitoring the Structural Health of Particle Accelerator

Rexolite is a cross-linked polystyrene plastic with stable electrical properties into the gigahertz frequency range. The ability to withstand high voltage makes Rexolite one of the most used materials as insulators for particle accelerators. Although, Rexolite’s poor outgassing performance relative to traditional vacuum materials such as stainless steel or aluminum deems the necessity to treat Rexolite prior to its use as insulators. Insulators are mandatory for an accelerator system because a uniform electric field is required to ensure the alignment of the accelerated particles. Furthermore, to operate properly, a particle accelerator is required to maintain a high vacuum or even an ultrahigh vacuum. Although, because outgassing is the major contributor to the gas load of a vacuum system, Rexolite insulators with uncontrolled outgassing characteristics can severely damage the particle accelerator. Disassembly and reassembly of a complex system like a particle accelerator is also time consuming.

36 MATERIALS SCIENCE↗