At least 379 records · Page 21

Formation, cooling history and age of impact events on the IIE iron parent body: Evidence from the Miles meteorite

Most iron meteorites formed in planetary cores during differentiation, but the IIE iron meteorites have chemical and physical features that are inconsistent with this origin. By combining mineral chemistry, mineral modes and three-dimensional petrography, we reconstruct the bulk chemistry of the felsic silicate-bearing Miles IIE iron meteorite and demonstrate that the silicate inclusion compositions are similar to partial melts produced experimentally from an H chondrite composition. We use the reconstructed bulk composition, mineralogy and thermodynamic modelling to show that melting above ~ 1200°C under reducing conditions formed metal (Fe-Ni alloy) and felsic silicate partial melts. Upon cooling, the melts crystallized Mg-rich pyroxenes, Na- and K-rich feldspars, and tridymite. Importantly, this mechanism enriches cosmochemically volatile elements (i.e., those with a 50% condensation temperature of ~430–830°C, like Na and K) to the level found in the felsic silicate inclusions. The presence of crystallographically disordered srilankite (only stable above 1160°C) and an absence of Widmanstätten texture require both high peak temperatures and rapid cooling, which cannot be explained by core formation. Instead, they point to small melt volumes, a transient heat pulse, and small thermal mass, and imply efficient physical segregation of silicate and metallic melts through buoyancy separation followed by rapid cooling that arrested the separation of metal and silicate liquid phases. In situ 207 Pb/ 206 Pb age of 4542.3 ± 4.0 Ma in Zr-oxide and phosphate minerals dates the melting event that formed the silicate inclusions. This age aligns with the earliest ages found in other IIE iron meteorite silicates and requires a heating event ~25 million years after the solar system formed. We found 39 Ar/ 40 Ar ages of 3495 ± 52 Ma (low-T) and 4303 ± 7 Ma (high-T) in a K-feldspar grain, with the 3495 Ma age aligning with later thermal events recorded in other IIE iron meteorites. Dating reveals the complex petrogenetic and thermal history of Miles and the IIE iron meteorites. This is the first IIE iron meteorite found to record evidence of heating at 4.5 and 3.5 Ga likely from impact events. We propose that high-velocity impact(s) into an iron-rich, porous chondritic parent body at ~4.54 Ga produced immiscible metal and silicate melts that cooled rapidly and trapped low density silicate inclusions within high density metal. Other IIE irons that formed at lower peak temperatures (900–1000°C) contain chondritic silicate inclusions and relict chondrules, supporting this conceptual model. In conclusion, this petrogenesis is consistent with thermodynamic modelling, experimental data and the wide range of peak temperatures and cooling rates observed in the IIE iron meteorites.

58 GEOSCIENCES↗

Larger Cloud Liquid Water Enhances Both Aerosol Indirect Forcing and Cloud Radiative Feedback in Two Earth System Models

Previous studies have noticed that the Coupled Model Intercomparison Project Phase 6 (CMIP6) models with a stronger cooling from aerosol-cloud interactions (ACI) also have an enhanced warming from positive cloud feedback, and these two opposing effects are counter-balanced in simulations of the historical period. However, reasons for this anti-correlation are less explored. In this study, we perturb the cloud ice microphysical processes to obtain cloud liquid of varying amounts in two Earth System Models (ESMs). We find that the model simulations with a larger liquid water path (LWP) tend to have a stronger cooling from ACI and a stronger positive cloud feedback. More liquid clouds in the mean-state present more opportunities for anthropogenic aerosol perturbations and also weaken the negative cloud feedback at middle to high latitudes. This work, from a cloud state perspective, emphasizes the influence of the mean-state LWP on effective radiative forcing due to ACI (ERF ACI ).

54 ENVIRONMENTAL SCIENCES↗

Internally cooled membrane-based absorber for dehumidification and water heating: Validated model and simulation study

This report presents a comprehensive model for advanced membrane-based absorber components accounting for three separate fluid streams, one of them providing internal cooling, with complex flow patterns. The model was implemented with various liquid desiccants and their properties (including LiCl, CaCl 2 , and [emim][OMS] ionic liquid [IL]). The model has been validated using data from two laboratory prototype absorbers, one with CaCl 2 as the working fluid and one with an IL as the working fluid. Entropy analysis was further carried out to verify the model and understand effect of internal cooling on the entropy variation of three fluid streams. The developed model and codes are expected to enable detailed configuration optimization and provide in-depth understanding of three-fluid heat and mass exchanger (HMX) performance. The paper also describes parametric studies of the HMX components in utilizing the latent heat removed in space cooling to heat water and numerically explores the unique benefit of its application in a semi-open absorption heat pump water heater. The results show that a single three-fluid HMX has the potential to achieve simultaneous dehumidification and water heating efficiently at cost effectiveness, particularly in hot and humid climates.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Review of liquid desiccant air dehumidification systems coupled with heat pump: System configurations, component design, and performance

Vapor Compression Systems (VCS) are the most common air conditioning technology. VCS cool the air to its dew point temperature (overcooling) to remove water vapor in the air through condensation and then reheats the air back to the comfort temperature for direct use. The VCS process is inefficient due to overcooling and reheating. Liquid Desiccant Dehumidification (LDD) is a potentially energy-efficient air conditioning. LDD removes water vapor in the process air using liquid desiccant’s high-water affinity. It hybrids with sensible cooling to control temperature and humidity separately. The LD in the LDD becomes weak after dehumidification. The LDD needs additional heating to regenerate the weak Liquid Desiccant (LD) to a high concentration for dehumidification. Earlier versions of the LDD systems use highly concentrated liquid desiccant (large water removal capability) to dehumidify the air by only dealing with latent load. It leads to highly elevated temperatures above 60 °C of heat sources (combustion or electric resistance-based heating) for regeneration. The energy needed for the elevated temperature heat resource significantly reduces or demolishes the benefit of LDD systems. In the recent two decades, researchers have investigated a new configured LDD system that couples an LDD with a heat pump at both dehumidification and regeneration sides for better efficiency. The heat pump provides cooling (from the evaporator) for both dehumidification and sensible cooling and simultaneous heating from the condenser for regeneration. The highly integrated system (HP-LDD) with improved efficiency enables the LDD to operate at lower concentrations and temperatures in dehumidification and regeneration. This paper depicts the working principle behind HP-LDD and its heating and cooling requirements. It reviews the comparison between the HP-LDD systems and the conventional LDD systems regarding system configurations, component design, energy efficiency, and dehumidification performance characteristics. The main findings from the review include the preferred use of packed bed over membrane-based dehumidifiers, the use of internally cooled dehumidifiers enabled by the HP cooling capacity, the high dispersion of HP operation conditions, and the dependence of dehumidification performance on various dehumidifiers. Finally, an outlook for future research on HP-LDD strategies is presented based on the reviewed works and their limitations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Technical Documents for Gateway for Accelerated Innovation in Nuclear (GAIN)

The Gateway for Accelerated Innovation in Nuclear (GAIN) provides the nuclear energy community with access to the technical, regulatory, and financial support necessary to move new or advanced nuclear reactor designs toward commercialization. GAIN provides the nuclear community with a single point of access to the broad range of capabilities (i.e., people, facilities, materials, and data) across the U.S. Department of Energy (DOE) complex and its National Lab capabilities. The Fast Flux Test Facility (FFTF) is the most recent liquid metal reactor (LMR) to be designed, constructed, and operated by DOE. The 400-MWt sodium-cooled, fast-neutron flux reactor plant was designed for irradiation testing of nuclear reactor fuels and materials for liquid metal fast breeder reactors. Following the demise of the breeder reactor program in the United States, FFTF continued to play a key role in providing a test bed for demonstrating performance of advanced fuel designs and demonstrating operation, maintenance, and safety of advanced liquid metal reactors. The FFTF Program provides valuable information for potential follow-on reactor projects in the areas of plant system and component design, component fabrication, fuel design and performance, reactor control, prototype testing, and site construction. This report provides documents related to three important aspects of FFTF design and operation: 1) irradiation behavior of structural alloys and absorber materials, 2) thermohydraulics of rod bundles (i.e., coolant mixing), and 3) natural circulation heat transfer in the areas of modeling and validation. These technical documents are believed to be of interest to the nuclear industry and in particular to designers of new liquid metal reactors.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Advanced Materials Program Summary

Advanced Reactor Technologies (ART) Advanced Materials Program: Provide material solutions to enable design, construction, and operation of licensable advanced reactors Including Gas-cooled Reactors, Fast Reactors, Molten Salt Reactors (solid or liquid fuel) Could be of modular design, and from 350 to 1 Mwe Conduct developmental R&D on structural materials that are best addressed by the national program Integrate program-directed work at national labs & universities and collaboration with international partners to address advanced reactor developer needs Provide qualification data (to NQA-1 or equivalent) on structural materials and develop & validate improved high temperature design methodology Utilize consensus standards organizations when appropriate (e.g., ASME, ASTM, etc.) Target resolution of issues needed for near to mid-term deployment of advanced reactors

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Constraining aerosol–cloud adjustments by uniting surface observations with a perturbed parameter ensemble

Abstract. Aerosol–cloud interactions (ACIs) are the largest source of uncertainty in inferring the magnitude of future warming consistent with the observational record. The effective radiative forcing due to ACI (ERFaci) is dominated by liquid clouds and is composed of two terms: the change in cloud albedo due to redistributing liquid over a larger number of cloud droplets (Nd) and the change in cloud macrophysical properties due to changes in cloud microphysics. These terms are, respectively, referred to as the radiative forcing due to ACI (RFaci) and aerosol–cloud adjustments. While the magnitude of RFaci is uncertain, its sign is confidently negative and results in a cooling in the historical record. In contrast, the adjustment of cloud liquid water path (LWP) to enhanced Nd and associated radiative forcing is uncertain in sign. Increased LWP in response to increased Nd is consistent with precipitation suppression, while decreased LWP in response to increased Nd is consistent with enhanced evaporation from cloud top. Observational constraints of these processes are poor in part because of causal ambiguity in the relationship between Nd and LWP. To better understand this relationship, precipitation (P), Nd, and LWP surface observations from the Eastern North Atlantic (ENA) atmospheric observatory are combined with the output from a perturbed parameter ensemble (PPE) hosted in the Community Atmosphere Model version 6 (CAM6). This allows for causal interpretation of observed covariability. Observations of precipitation and cloud from ENA constrain the range of possible LWP aerosol–cloud adjustments relative to the prior from the PPE by 15 %, resulting in a global value that is confidently positive (a historical cooling) ranging from 2.1 to 6.9 g m−2. It is found that observed covariability between Nd and LWP is dominated by coalescence scavenging and that this observed covariability is not strongly related to aerosol–cloud adjustments.

54 ENVIRONMENTAL SCIENCES↗

Automated cryogenic refilling system

An improved system and method for the automated refilling of cryogenic helium is provided. In one embodiment, the system includes a dewar in fluid communication with a liquid helium cryostat through a cryogen transfer line. A controller regulates operation of a three-way valve to pre-cool the transfer line and to cause gaseous helium to flow to the dewar and force liquid helium through the transfer line into the cryostat. The controller is coupled to the output of a cryogenic level sensor, such that the controller regulates the helium liquid level within the cryostat. During filling cycles, the dewar liquid level is also monitored by the cryogenic level sensor and an alarm sounds if the dewar liquid level is undesirably low. Between filling cycles, the controller is operable to ventilate the dewar through a solenoid vent valve in fixed time intervals to ensure the dewar pressure is sufficiently low so as to not bleed liquid helium into the cryostat.

Ruiz-Rodriguez, Mariano M.↗

Origin of short- and medium-range order in supercooled liquid Ge 3 Sb 2 Te 6 from ab initio molecular dynamics simulations

Phase-change materials such as Ge–Sb–Te compounds have attracted much attention due to their potential value in electrical data storage. In contrast to the amorphous and crystalline phases, supercooled liquids are far from being deeply understood despite their inevitable role in both amorphization and crystallization processes. To this end, we have studied the dynamics properties and structural characteristics of liquid and supercooled liquid Ge 3 Sb 2 Te 6 during the fast cooling process. As the temperature decreases, chemical bonds become more homogeneous, but coordination numbers of Ge, Sb and Te atoms change very little. Meanwhile, the structural order of short-range configuration is obviously enhanced. Further studies suggest that Ge-centered, Sb-centered and Te-centered configurations change to the more ordered defective octahedrons mainly by adjusting the bond-angle relationship and bond length, rather than just by changing the coordination environment. It is the more ordered octahedrons that promote the formation of medium-range order. Our findings provide a deep insight into the origin of local structural order in supercooled liquid Ge 3 Sb 2 Te 6 , which is of great importance for the comprehensive understanding of amorphization and crystallization processes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Modeling Water Vapor Transport at Liquid/Membrane Interfaces for Applications in Liquid Desiccant Air Conditioners (CRADA CRD-17-679 Final Report)

Conventional compressor-based cooling has undergone incremental changes over the past 100 years. Further improvements in efficiency require evermore complex systems, especially under humid conditions. Meso-porous membranes offer unique opportunities for efficient humidity control in buildings using an absorbent desiccant solution, but membranes are not designed or optimized for this purpose. This project will use molecular dynamic simulations to determine optimal membrane properties for these air conditioning applications, focusing on the membrane properties at the membrane/liquid/air interface. Optimal membrane designs will enable smaller, more durable, and less expensive designs of these membrane air conditioning systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Measurement of Thermal Conductivity in a Supercooled Hydrogel-Salt Complex Near Its Phase Transition

Solid-liquid phase transitions, i.e. solidification processes, have applications in data storage, development of novel thermoelectric materials, cooling of microelectronic substrates and air conditioning condensers. Standard analyses of solidification (Stefan problem) assume constant thermal properties of the solid and liquid sides. It is not known how these properties change across the spatial transition interface, though most studies report a discontinuity in the solid and liquid properties through the transition temperature [1]. When the phase transition releases enthalpy, recent research has shown if the phonon or electron transport time is of the same order of magnitude as the time scale of the atomic transformation, this increases the heat capacity of the solid material at temperatures near the phase transition temperature [2]. A fundamental understanding of the phase transition may help shed light on the molecular origins of supercooling and spontaneous nucleation, which will help with applications involving them. We report studies of supercooling and nucleation of sodium sulfate decahydrate, a salt hydrate which is of recent interest in thermal storage, and of a hydrogel-sodium sulfate complex which shows limited supercooling. We will also report the measurement of their thermal properties during the phase transition process. This will be done with a hot-wire setup which produces small temperature changes of the order of ~1 C.

crystallization, phase transformation, thermal con↗

Experimental test of a predicted dynamics–structure–thermodynamics connection in molecularly complex glass-forming liquids

Significance The physical origin of cooperative activated relaxation in glass-forming liquids, which underlies the huge growth of viscosity and suppression of diffusion with cooling, remains elusive. Understanding this problem is of fundamental scientific interest and can assist in the design of new materials. We combine experimental relaxation time and equation-of-state data of molecular liquids to provide strong evidence for the recent theoretical prediction that activated relaxation, though causally driven by dynamically coupled cage-scale hopping and nonlocal collective elasticity quantified by local structural correlations, is well captured based on a thermodynamic description with dimensionless compressibility as the key variable. A mechanistic deduction is the crossover from fragile to strong (e.g., inorganic networks) relaxation behavior arises from the irrelevance of long-range elasticity effects.

36 MATERIALS SCIENCE↗

History, present status, and future directions of vanadium alloys for fusion reactors

Since the need for low-activation fusion reactor materials was recognized in the mid-1980s, vanadium alloys have been researched and developed as promising candidates for blanket structural materials. Vanadium alloys are non-ferromagnetic and ductile materials and thus have advantages different from other candidates. However, since vanadium alloys are still at a premature industrial stage, research and development have been carried out not only on issues specific to fusion reactors but also on those related to industrial materials. Blankets using vanadium alloys as structural materials and liquid Li as a tritium breeder and coolant (self-cooled V/Li blankets) have unique characteristics, and research and development of issues specific to V/Li blankets have been conducted in conjunction with the development of vanadium alloys. In this paper, the progress of this research and development is reviewed, and the remaining issues are pointed out. As a result, the future direction of vanadium alloy research and development is discussed, considering recent changes in the environment surrounding fusion energy.

Liquid Li blanket↗

Wastewater Recycling Using a Hygroscopic Cooling System

This project by the Energy & Environmental Research Center (EERC), Baltimore Aircoil Company (BAC), and Great River Energy (GRE) evaluated the concept of recycling wastewater at a coal-fired power plant using a hygroscopic cooling system, which is an evaporative cooling technology analogous to conventional cooling towers, except that sparingly soluble dissolved solids are precipitated and removed as waste solids instead of purging them with a liquid blowdown stream. This technology can maximize the use of plant makeup water by obtaining useful evaporative cooling from wastewater while minimizing the volume of wastes needing disposal. Experimental activities were conducted in two phases, a laboratory-based evaluation of the properties of wastewater from the host site, GRE’s Coal Creek Station near Underwood, North Dakota, and a field test of a small pilot hygroscopic cooling system at the host site power plant. Findings from the laboratory study informed the design of the pilot system and the system’s field test performance served as the basis for a techno-economic analysis (TEA) of the hygroscopic recycling concept. At the preferred operating conditions identified during the TEA, the wet-bulb approach temperature of the tower was 7.3°C (13°F) and the volume of blowdown produced by the plant was reduced to 5.4% of its incoming volume. Waste solids produced during field testing were classified as nonhazardous waste based on the measured hazardous element content and evaluation of their leaching potential. However, to qualify as a solid for landfill disposal i.e., as determined by the U.S. Environmental Protection Agency’s paint filter test, it appears that a dewatering step beyond hydrocyclone separation is needed. The baseline levelized cost of wastewater disposal (LCWD) for hygroscopic wastewater recycling was estimated to be $\$ $3.69–$\$ $3.72 per m3 of plant blowdown. Capital cost was estimated to contribute over 54% to the LCWD, and parameters that impact capital cost such as the heat exchange coil material of construction and the tower’s wet-bulb approach temperature were identified as having the greatest impact on overall LCWD. A LCWD estimate prepared for the same application but using thermomechanical brine evaporation was almost 40% higher than that calculated for hygroscopic cooling, despite recovering distilled-quality water for reuse, while the LCWD for disposal-only, deep well injection was estimated to be 30% lower compared to hygroscopic wastewater recycling.

01 COAL, LIGNITE, AND PEAT↗

A thermodynamic model of integrated liquid-to-liquid thermoelectric heat pump systems

Thermoelectric (TE) heat pumps (TEHPs) are advantageous for heating and cooling in various applications because of their modularity and simple design. A TEHP system includes the TE modules with p- and n-type materials bonded to substrates, plus heat exchangers, thermal interfaces to the heat exchangers, and heat transfer fluids. Although modeling an individual TE module has been extensively studied, limited studies have reported performance at the larger system-level. Furthermore, no prior study has addressed the impact of temperature-dependent TE material properties (e.g., electric resistivity, thermal conductivity, and Seebeck coefficient) on overall heat-pump-system-level performance. Here, this work presents a mathematical model for TEHP system performance based on Goldsmid's approach for TE material performance, “effective” TE material properties, Gnielinski's correlation for convective heat transfer, and thermal balance theory for a heat exchange network. This combined approach provides an accurate model of the liquid-to-liquid TEHP system. Three different approaches—one empirical, one based on the manufacturer's specifications, and one drawn from the literature—were then used to determine values for TE material properties. The first two methods treated properties as constants, while the last approach treated properties as surface-temperature-based functions. Finally, experimental TEHP data was used to validate the models, all with relative absolute deviations of approximately 10% when predicting heating capacity and 10%–25% when forecasting cooling capacity up to a 30 K surface temperature lift. The results demonstrated that, at the TEHP system level, the TE material properties could be treated as constants, avoiding solver iterations and reducing the performance uncertainty by up to 95%.

42 ENGINEERING↗

Medium-Range Structural Order as the Driver of Activated Dynamics and Complexity Reduction in Glass-Forming Liquids

Here, we analyze in depth the Elastically Collective Nonlinear Langevin Equation theory of activated dynamics in metastable liquids to establish that the predicted inter-relationships between the alpha relaxation time, local cage and collective elastic barriers, dynamic localization length, and shear modulus are causally related within the theory to the medium range order (MRO) static correlation length. The latter grows exponentially with density for metastable hard sphere fluids and as a nonuniversal inverse power law with temperature for supercooled liquids under isobaric conditions. The physical origin of predicted connections between the alpha time and other metrics of cage order and the thermodynamic inverse dimensionless compressibility is fully established. It is discovered that although kinetic constraints from the real space first coordination shell are important for the alpha time, they are of secondary importance compared to the consequences of the more universal MRO correlations in both the modestly and deeply metastable regimes. This understanding sheds new light on the theoretical basis for, and prior successes of, the predictive mapping of chemically complex thermal liquids to effective hard sphere fluids based on matching their dimensionless compressibilities, a scheme we call “complexity reduction”. In essence, the latter is equivalent to the physical requirement that the thermal liquid MRO correlation equals that of its effective hard sphere analog. The mapping alone is shown to provide a remarkable level of quantitative predictive power for the glass transition temperature T g of 21 molecular and polymer liquids. Predictions for the chemically specific absolute magnitude and growth with cooling of the MRO correlation length are obtained and lie in the window of 2–6 nm at T g . Dynamic heterogeneity, elastic facilitation, and beyond pair structure issues are briefly discussed. Future opportunities to theoretically analyze the equilibrated deep glass regime are outlined.

cancer↗

Material assembly from collective action of shape-changing polymers

Some animals form transient, responsive and solid-like ensembles through dynamic structural interactions. These ensembles demonstrate emergent responses such as spontaneous self-assembly, which are difficult to achieve in synthetic soft matter. In this work, we use shape-morphing units comprising responsive polymers to create solids that self-assemble, modulate their volume and disassemble on demand. The ensemble is composed of a responsive hydrogel, liquid crystal elastomer or semicrystalline polymer ribbons that reversibly bend or twist. The dispersions of these ribbons mechanically interlock, inducing reversible aggregation. The aggregated liquid crystal elastomer ribbons have a 12-fold increase in the yield stress compared with cooled dispersion and contract by 34% on heating. Ribbon type, concentration and shape dictate the aggregation and govern the global mechanical properties of the solid that forms. Coating liquid crystal elastomer ribbons with a liquid metal begets photoresponsive and electrically conductive aggregates, whereas seeding cells on hydrogel ribbons enables self-assembling three-dimensional scaffolds, providing a versatile platform for the design of dynamic materials.

36 MATERIALS SCIENCE↗

Ultralow-temperature cryogenic transmission electron microscopy using a new helium flow cryostat stage

Advances in cryogenic electron microscopy have opened new avenues for probing quantum phenomena in correlated materials. This study reports the installation and performance of a new side-entry condenZero cryogenic cooling system for JEOL (Scanning) Transmission Electron Microscopes (S/TEM), utilizing compressed liquid helium (LHe) and designed for imaging and spectroscopy at ultra-low temperatures. The system includes an external dewar mounted on a vibration-damping stage and a pressurized, low-noise helium transfer line with a remotely controllable needle valve, ensuring stable and efficient LHe flow with minimal thermal and mechanical noise. Performance evaluation demonstrates a stable base temperature of 4.37 K measured using a Cernox bare chip sensor on the holder with temperature fluctuations within ±0.004 K. Complementary in-situ electron energy-loss spectroscopy (EELS) via aluminum bulk plasmon analysis was used to measure the local specimen temperature and validate cryogenic operation during experiments. The integration of cryogenic cooling with other microscopy techniques, including electron diffraction and Lorentz TEM, was demonstrated by resolving charge density wave (CDW) transitions in NbSe2 using electron diffraction, and imaging nanometric magnetic skyrmions in MnSi via Lorentz TEM. In conclusion, this platform provides reliable cryogenic operation below 7 K, establishing a low-drift route for direct visualization of electronic and magnetic phase transformations in quantum materials.

Charge density wave↗