Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “light source”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

A SYNCHRONIZED FIR/VUV LIGHT SOURCE AT JEFFERSON LAB

We describe a dual free-electron laser (FEL) configuration on the UV Demo FEL at Jefferson Lab that allows simultaneous lasing at FIR/THz and UV wavelengths. The FIR/THz source would be an FEL oscillator with a short wiggler providing nearly diffraction-limited pulses with pulse energy exceeding 50 microJoules. The FIR source would use the exhaust beam from a UVFEL. The coherent harmonics in the VUV from the UVFEL are out-coupled through a hole. The FIR source uses a shorter resonator with either hole or edge coupling to provide very high power FIR pulses. Simulations indicate excel-lent spectral brightness in the FIR region with over 100 W/cm-1 output.

43 PARTICLE ACCELERATORS↗

Strong Einstein-Podolsky-Rosen entanglement from a single squeezed light source

Einstein-Podolsky-Rosen (EPR) entanglement is a criterion that is more demanding than just certifying entanglement. We theoretically and experimentally analyze the low-resource generation of bipartite continuous-variable entanglement, as realized by mixing a squeezed mode with a vacuum mode at a balanced beam splitter, i.e., the generation of so-called vacuum-class entanglement. We find that in order to observe EPR entanglement the total optical loss must be smaller than 33.3 %. However, arbitrarily strong EPR entanglement is generally possible with this scheme. We realize continuous-wave squeezed light at 1550 nm with up to 9.9 dB of nonclassical noise reduction, which is the highest value at a telecom wavelength so far. Using two phase-controlled balanced homodyne detectors we observe an EPR covariance product of 0.502{+-}0.006<1, where 1 is the critical value. We discuss the feasibility of strong Gaussian entanglement and its application for quantum key distribution in a short-distance fiber network.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Paraxial SGM beamlines for coherence experiments at the Advanced Light Source

Beamlines have been designed for coherence experiments at the ALS based on brightness preserving spherical grating monochromators. The operation is almost paraxial so that a very simple scheme can deliver the modest spectral resolution required, with just two focusing optics, one of which is the spherical grating.

47 OTHER INSTRUMENTATION↗

Ultra Low Emittance Light Sources

This paper outlines the special issues for reaching sub-nm emittance in a storage ring. Effects of damping wigglers, intra-beam scattering and lifetime issues, dynamic aperture optimization, control of optics, and their interrelations are covered in some detail. The unique choices for the NSLS-II are given as one example.

43 PARTICLE ACCELERATORS↗

Data of heavy elements for light sources in EUV and XUV and for other applications

Atomic ionic states and transition properties of elements with atomic numbers Z ranging from 50 to 80 are discussed as these are important to the understanding of plasmas containing such heavy elements. As such, data productions and the current status of theoretical calculations in this field are discussed. Further, recent spectroscopic measurements and respective theoretical analyses for W, Gd, and Nd are provided. The spectra of photoemissions elicited by the transitions between the sub-shell levels in N-sub-shell open atomic ions are of interest for the strong influence received from the interactions between the electronic state configurations with different constituent orbitals. Visible light emissions of W from M1 as well as E2 transitions are introduced and discussed.

74 ATOMIC AND MOLECULAR PHYSICS↗

Techniques and use of a tunable, laser-based, MeV-Class Compton scattering light source

A Compton scattering {gamma}-ray source, capable of producing photons with energies ranging from 0.1 MeV to 0.9 MeV has been commissioned and characterized, and then used to perform nuclear resonance fluorescence (NRF) experiments. The key source parameters are the size (0.01 mm{sup 2}), horizontal and vertical divergence (6 x 10 mrad{sup 2}), duration (10 ps), spectrum and intensity (10{sup 5} photons/shot). These parameters are summarized by the peak brightness, 1.5 x 10{sup 15} photons/mm{sup 2}/mrad{sup 2}/s/0.1%bandwidth, measured at 478 keV. Additional measurements of the flux as a function of the timing difference between the drive laser pulse and the relativistic photoelectron bunch, {gamma}-ray beam profile, and background evaluations are presented. These results are systematically compared to theoretical models and computer simulations. NRF measurements performed on {sup 7}Li in LiH demonstrate the potential of Compton scattering photon sources to accurately detect isotopes in situ.

42 ENGINEERING↗

Jitter Studies for a 2.4 GeV Light Source Accelerator Using LiTrack

Electron beam quality is an important factor in the performance of a free electron laser (FEL). Parameters of particular interest are the electron beam energy, slice emittance and energy spread, peak current, and energy chirp. Jitter in average energy is typically many times the slice energy spread. A seeded FEL is sensitive not only to these local properties but also to factors such as shot-to-shot consistency and the uniformity of the energy and current profiles across the bunch. The timing and bunch length jitter should be controlled to maximize the interval of time over which the electron beam can be reliably seeded by a laser to produce good output in the FEL. LiTrack, a one-dimensional tracking code which includes the effect of longitudinal wakefields, is used to study the sensitivity of the accelerator portion of a 2.4 GeV FEL to sources of variability such as the radio frequency (RF) cavities, chicanes, and the timing and efficiency of electron production at the photocathode. The main contributors to jitter in the resulting electron beam are identified and quantified for various figures of merit.

43 PARTICLE ACCELERATORS↗

Science and Technology of Future Light Sources

Many of the important challenges facing humanity, including developing alternative sources of energy and improving health, are being addressed by advances that demand the improved understanding and control of matter. While the visualization, exploration, and manipulation of macroscopic matter have long been technological goals, scientific developments in the twentieth century have focused attention on understanding matter on the atomic scale through the underlying framework of quantum mechanics. Of special interest is matter that consists of natural or artificial nanoscale building blocks defined either by atomic structural arrangements or by electron or spin formations created by collective correlation effects. The essence of the challenge to the scientific community has been expressed in five grand challenges for directing matter and energy recently formulated by the Basic Energy Sciences Advisory Committee [1]. These challenges focus on increasing our understanding of, and ultimately control of, matter at the level of atoms, electrons. and spins, as illustrated in Figure 1.1, and serve the entire range of science from advanced materials to life sciences. Meeting these challenges will require new tools that extend our reach into regions of higher spatial, temporal, and energy resolution. X-rays with energies above 10 keV offer capabilities extending beyond the nanoworld shown in Figure 1.1 due to their ability to penetrate into optically opaque or thick objects. This opens the door to combining atomic level information from scattering studies with 3D information on longer length scales from real space imaging with a resolution approaching 1 nm. The investigation of multiple length scales is important in hierarchical structures, providing knowledge about function of living organisms, the atomistic origin of materials failure, the optimization of industrial synthesis, or the working of devices. Since the fundamental interaction that holds matter together is of electromagnetic origin, it is intuitively clear that electromagnetic radiation is the critical tool in the study of material properties. On the level of atoms, electrons, and spins, x-rays have proved especially valuable. Future advanced x-ray sources and instrumentation will extend the power of x-ray methods to reach greater spatial resolution, increased sensitivity, and unexplored temporal domains. The purpose of this document is threefold: (1) summarize scientific opportunities that are beyond the reach of today's x-ray sources and instrumentation; (2) summarize the requirements for advanced x-ray sources and instrumentation needed to realize these scientific opportunities, as well as potential methods of achieving them; and (3) outline the R&D required to establish the technical feasibility of these advanced x-ray sources and instrumentation.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Brain protein deciphered at Advanced Light Source

This computer-generated model of a rat glutamate receptor is the first complete portrait of this important link in the nervous system. At the top of the Y-shaped protein, a pair of molecules splay outward like diverging prongs. The bottom section, which is embedded in a neuronal membrane, houses the ion channel. The resolution of this image is 3.6 angstroms per pixel, or just under four ten-billionths of a meter per image unit. http://newscenter.lbl.gov/feature-stories/2010/01/21/glutamate-receptor/

43 PARTICLE ACCELERATORS↗

Single plasmonic split hole resonator nanostructure as an efficient nanoscale light source

We report a brief review of the results of experimental studies on the nonlinear optical interaction of laser radiation with a hybrid plasmonic nanostructure, i.e. a split hole resonator (SHR). We demonstrate second- and third-harmonic generation and mixed-frequency generation from a single SHR nanostructure. The practical application potential of an SHR nanostructure as a nanoprobe for measuring the femtosecond laser pulse duration and designing an all-optical nanodisplay is shown. (paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Cold-target recoil-ion momentum spectroscopy for diagnostics of high harmonics of the extreme-ultraviolet free-electron laser light source at SPring-8

We have developed a cold-target recoil-ion momentum spectroscopy apparatus dedicated to the experiments using the extreme-ultraviolet light pulses at the free-electron laser facility, SPring-8 Compact SASE Source test accelerator, in Japan and used it to measure spatial distributions of fundamental, second, and third harmonics at the end station.

43 PARTICLE ACCELERATORS↗

Cavity formation in a liquid Sn droplet driven by laser ablation pressure for an extreme ultraviolet light source target

An in situ approach to the formation of cavities in liquid Sn droplets for the purpose of increasing ion density from Sn plasma produced by a CO{sub 2} laser is investigated. Two-dimensional hydrodynamic simulations, treating the laser as a pulsed pressure source, are compared both spatially and temporally to experimental shadowgraphs for verification of cavity formation. It is shown that a 15 ns pulse from a 1.064 {mu}m laser with intensity of 2 x 10{sup 10} W/cm{sup 2} creates a cavity approximately 300 {mu}m wide and 100 {mu}m deep in approximately 1.4 {mu}s. The presence of the cavity enhances the conversion of laser energy to 13.5 nm radiation from the plasma.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Reconciling FTIR Spectroscopy with Top-off Operations at the Advanced Light Source

Top-off operations is a quasi-continuous injection mode that increases the flux and brightness of a synchrotron source and improves thermal stability of optical components by maintaining a constant current in the storage ring. Although the increased and constant flux is advantageous for FTIR measurements, the frequent injections (about one every 30 seconds in the ALS case) introduce artifacts into the spectrum by creating spikes in the interferogram data. These spikes are caused by brief beam motion during the injection event. Here, we describe our efforts to minimize the effects of top-off generated interferogram spikes on several FTIR spectrometers. They include using a fast feedback mirror system to correct for beam motion and a gating signal to inhibit interferogram collection during a top-off injection.

43 PARTICLE ACCELERATORS↗

From 3rd- to 4th-generation light sources: Free-electron lasers in the X-ray range

Activities on free-electron laser (FEL) x-ray sources, based on linear accelerators, to produce spatially coherent, ultra-short ({approx}100 fs) pulses with very high peak brilliance (10{sup 28}-10{sup 32} photons/s/mm{sup 2}/mrad{sup 2}/0.1% BW) are summarized. The scientific case includes time-resolved studies of dynamics on sub-ps scales, structural studies by imaging of non-periodic systems, and investigation of high energy-density phenomena such as non-linear x-ray optics and the production of warm dense matter. Examples are presented, with emphasis on the operational facilities, FLASH at DESY, Hamburg and LCLS in Stanford, California, and on the European XFEL project in Hamburg.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Reconciling FTIR Spectroscopy with Top-off Operations at the Advanced Light Source

Top-off operations is a quasi-continuous injection mode that increases the flux and brightness of a synchrotron source and improves thermal stability of optical components by maintaining a constant current in the storage ring. Although the increased and constant flux is advantageous for FTIR measurements, the frequent injections (about one every 30 seconds in the ALS case) introduce artifacts into the spectrum by creating spikes in the interferogram data. These spikes are caused by brief beam motion during the injection event. Here, we describe our efforts to minimize the effects of top-off generated interferogram spikes on several FTIR spectrometers. They include using a fast feedback mirror system to correct for beam motion and a gating signal to inhibit interferogram collection during a top-off injection.

47 OTHER INSTRUMENTATION↗

Soft x-ray scattering facility at the Advanced Light Source with real-time data processing and analysis

We present the development and characterization of a dedicated resonant soft x-ray scattering facility. Capable of operation over a wide energy range, the beamline and endstation are primarily used for scattering from soft matter systems around the carbon K-edge ({approx}285 eV). We describe the specialized design of the instrument and characteristics of the beamline. Operational characteristics of immediate interest to users such as polarization control, degree of higher harmonic spectral contamination, and detector noise are delineated. Of special interest is the development of a higher harmonic rejection system that improves the spectral purity of the x-ray beam. Special software and a user-friendly interface have been implemented to allow real-time data processing and preliminary data analysis simultaneous with data acquisition.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Nanoscience Beamline (I06) at Diamond Light Source

The Nanoscience beamline (I06) is one of seven Diamond Phase-I beamlines which has been operational since January 2007 delivering polarised soft x-rays, for a PhotoEmission Electron Microscope (PEEM) and branchline, in the energy range 80-2100 eV. The beamline is based on a collimated plane grating monochromator with sagittal focusing elements, utilising two APPLE II helical undulator sources, and has been designed for high flux density at the PEEM sample position. A {approx}5 {mu}m ({sigma}) diameter beam is focussed onto the sample in the PEEM allowing a range of experiments using x-ray absorption spectroscopy (XAS), x-ray magnetic circular dichroism (XMCD) and x-ray magnetic linear dichroism (XMLD) as contrast mechanisms. The beamline is also equipped with a branchline housing a 6T superconducting magnet for XMCD and XMLD experiments. The magnet is designed to move on and off the branchline which allows a diverse range of experiments.

43 PARTICLE ACCELERATORS↗

A Test Beamline on Diamond Light Source

A Test beamline B16 has been built on the 3 GeV Diamond synchrotron radiation source. The beamline covers a wide photon energy range from 2 to 25 keV. The beamline is highly flexible and versatile in terms of the available beam size (a micron to 100 mm) and the range of energy resolution and photon flux; by virtue of its several operational modes, and the different inter-changeable instruments available in the experiments hutch. Diverse experimental configurations can be flexibly configured using a five-circle diffractometer, a versatile optics test bench, and a suite of detectors. Several experimental techniques including reflectivity, diffraction and imaging are routinely available. Details of the beamline and its measured performance are presented.

43 PARTICLE ACCELERATORS↗