Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “light detection and ranging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Solar Wind Speed Structure in the Inner Corona at 3-12 Ro

Estimates of solar wind speed obtained by Armstrong et al. [1986] based on 1983 VLA multiple-station intensity scintillation measurements inside 12 R(sub o) have been correlated with the electron density structure observed in white-light coronagraph measurements. The observed large- scale and apparently systematic speed variations are found to depend primarily on changes in heliographic latitude and longitude, which leads to the first results on large-scale speed structure in the acceleration region of the solar wind. Over an equatorial hole, solar wind speed is relatively steady, with peak-to-peak variations of 50 km/s and an average of 230 km/s. In contrast, the near-Sun flow speed across the streamer belt shows regular large-scale variations in the range of 100-300 km/s. Based on four groups of data, the gradient is 36 km/s per degree in heliocentric coordinates (corresponding to a rise of 260 km/s over a spatial distance on the Sun of two arcmin) with a standard deviation of 2.4 km/s per degree. The lowest speeds most likely coincide with the stalks of coronal streamers observed in white-light measurements. The detection of significant wind shear over the streamer belt is consistent with in situ and scintillation measurements showing that the density spectrum has a power-law form characteristic of fully developed turbulence over a much broader range of scales than in neighboring regions.

Woo, Richard↗

Virtual Instrumentation for a Fiber-Optics-Based Artificial Nerve

A LabView-based computer interface for fiber-optic artificial nerves has been devised as a Masters thesis project. This project involves the use of outputs from wavelength multiplexed optical fiber sensors (artificial nerves), which are capable of producing dense optical data outputs for physical measurements. The potential advantages of using optical fiber sensors for sensory function restoration is the fact that well defined WDM-modulated signals can be transmitted to and from the sensing region allowing networked units to replace low-level nerve functions for persons desirous of "intelligent artificial limbs." Various FO sensors can be designed with high sensitivity and the ability to be interfaced with a wide range of devices including miniature shielded electrical conversion units. Our Virtual Instrument (VI) interface software package was developed using LabView's "Laboratory Virtual Instrument Engineering Workbench" package. The virtual instrument has been configured to arrange and encode the data to develop an intelligent response in the form of encoded digitized signal outputs. The architectural layout of our nervous system is such that different touch stimuli from different artificial fiber-optic nerve points correspond to gratings of a distinct resonant wavelength and physical location along the optical fiber. Thus, when an automated, tunable diode laser sends scans, the wavelength spectrum of the artificial nerve, it triggers responses that are encoded with different touch stimuli by way wavelength shifts in the reflected Bragg resonances. The reflected light is detected and a resulting analog signal is fed into ADC1 board and DAQ card. Finally, the software has been written such that the experimenter is able to set the response range during data acquisition.

Lyons, Donald R.↗

Aerosol size determination via light scattering of viruses and protein complexes

Abstract The study of ultrafine particle aerosols, those with particle diameters of 100 nm or less, is important due to their impact on our health and environment. However, given their small sizes, such particles can be difficult to measure and trace. Most common optical methods are unable to reach this size range. Other methods exist but incur other limitations, such as the need for electrically charged particles. Here we show how light scattering can be used to detect and measure the size and location of single viruses and protein complexes forming an aerosol beam, as well as trace their path. We were able to detect individual particles down to 16 nm in diameter. The primary purpose of our instrument is to monitor the delivery of single bioparticles to the focus of an X-ray laser to image those particles, but it has the potential to study any other aerosols such as those resulting from ultrafine sea spray, with important consequences for cloud formation and climate modeling, or from combustion, responsible for most air pollution and resulting health impacts.

Physics↗

Recommended conventions for reporting results from direct dark matter searches

Abstract The field of dark matter detection is a highly visible and highly competitive one. In this paper, we propose recommendations for presenting dark matter direct detection results particularly suited for weak-scale dark matter searches, although we believe the spirit of the recommendations can apply more broadly to searches for other dark matter candidates, such as very light dark matter or axions. To translate experimental data into a final published result, direct detection collaborations must make a series of choices in their analysis, ranging from how to model astrophysical parameters to how to make statistical inferences based on observed data. While many collaborations follow a standard set of recommendations in some areas, for example the expected flux of dark matter particles (to a large degree based on a paper from Lewin and Smith in 1995), in other areas, particularly in statistical inference, they have taken different approaches, often from result to result by the same collaboration. We set out a number of recommendations on how to apply the now commonly used Profile Likelihood Ratio method to direct detection data. In addition, updated recommendations for the Standard Halo Model astrophysical parameters and relevant neutrino fluxes are provided. The authors of this note include members of the DAMIC, DarkSide, DARWIN, DEAP, LZ, NEWS-G, PandaX, PICO, SBC, SENSEI, SuperCDMS, and XENON collaborations, and these collaborations provided input to the recommendations laid out here. Wide-spread adoption of these recommendations will make it easier to compare and combine future dark matter results.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The masses of CMEs measured in the inner heliosphere

Nearly 200 coronal mass ejections (CME's) detected in the Helios one and two 90 deg zodiacal light photometers, observed from 1975-1983, were catalogued. The Helios spacecraft were in sun centered orbits ranging from 0.3 to 1.0 AU. From the photometer observations of Thomson scattered sunlight in the inner heliosphere, CME masses for a subset of these events were determined using two methods: by integration of the spatial mass distribution viewed by all three photometers at a given time, and by integration of the mass flow over time past a given photometer. The 2nd method depends on CME speeds measured from timing of the peak CME brightness between the 16 deg and 31 deg photometers. This 2nd method yields two measurements of the mass for a given CME. The masses derived by the different measurements are compared. It was found that the CME excess mass values range from 10(exp 15) g to nearly 10(exp 17) g. Over the solar cycle, the results show that the mean mass per CME increases by a factor of 1.5 from solar minimum to solar maximum. The total CME mass at solar maximum is found to be about 15 percent of the total solar wind mass.

Jackson, Bernard V.↗

Simulation and ground testing with the Advanced Video Guidance Sensor

The Advanced Video Guidance Sensor (AVGS), an active sensor system that provides near-range 6-degree-of-freedom sensor data, has been developed as part of an automatic rendezvous and docking system for the Demonstration of Autonomous Rendezvous Technology (DART). The sensor determines the relative positions and attitudes between the active sensor and the passive target at ranges up to 300 meters. The AVGS uses laser diodes to illuminate retro-reflectors in the target, a solid-state imager to detect the light returned from the target, and image capture electronics and a digital signal processor to convert the video information into the relative positions and attitudes. The development of the sensor, through initial prototypes, final prototypes, and three flight units, has required a great deal of testing at every phase, and the different types of testing, their effectiveness, and their results, are presented in this paper, focusing on the testing of the flight units. Testing has improved the sensor's performance.

Howard, Richard T.↗

Extreme Molecular Complexity Resulting in a Continuum of Carbonaceous Species in Biomass Burning Tar Balls from Wildfire Smoke

Biomass burning emits a wide range of carbonaceous particles into the atmosphere and has negative impacts on human health and the Earth’s radiative balance. Nonvolatile spherical organic aerosol particles, commonly known as tar balls, represent one of the most abundant particles in aged biomass burning smoke. However, the detailed molecular-level composition of ambient tar balls is largely unknown but critical to access their environmental impacts. Ambient aerosol samples collected during a wildfire event, which were ~90% tar balls by number fraction, were analyzed using ultrahigh resolution Orbitrap Elite mass spectrometry with four complementary ionization modes. Our results show the molecular composition of tar balls to be complex, composed of over 10,000 molecular formulas. Model estimated saturation mass concentrations and relative humidity dependent glass transition temperatures were consistent with low volatility and solid morphology as expected for tar balls. Room-temperature evaporation kinetics showed that these particles were composed of ~90% non-volatile species. The molecular complexity detected here signifies a continuum of carbonaceous species, ranging from C3 to C45 with continuous ranges of oxygenation and hydrogen saturation for each Cn. Approximately 24% of molecular formulas were estimated the be highly aromatic, which could indicate chemical compounds with negative health effects, and which may contribute to visible light absorption. The carbon continuum observed here has significant implications for the molecular characterization of atmospheric organic matter. The level of complexity detected here should not be ignored in future studies and we demonstrate that multiple analytical methods may be required to suitably interpret this complexity on a molecular level.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Laser Doppler spectrometer method of particle sizing

A spectrometer for the detection of airborne particulate pollution in the submicron size range is described. In this device, airborne particles are accelerated through a supersonic nozzle, with different sizes achieving different velocities in the gas flow. Information about the velocities of the accelerated particles is obtained with a laser-heterodyne optical system through the Doppler shift of light scattered from the particles. Detection is accomplished by means of a photomultiplier. Nozzle design and signal processing techniques are also discussed.

Weber, F. N.↗

Observation of thermally activated coherent magnon-magnon coupling in a magnonic hybrid system

In this work, we experimentally demonstrate coherent magnon-magnon coupling by thermal spin excitations in yttrium iron garnet/permalloy (YIG/Py) hybrid structures using microfocused Brillouin light scattering—an optical technique that enables the detection of zero-wave-vector and higher-order wave-vector spin waves in a broad frequency range. The thermally activated magnons in the bilayer lead to a hybrid excitation between magnon modes in the conductive Py layer with a wide wave-vector range and the first perpendicular standing magnon modes in the insulating YIG layer, facilitated by strong interfacial exchange coupling. To further investigate this coupling, we compare the thermal magnon spectra with the results obtained from electrical excitation and detection methods, which primarily detect the uniform Py mode. The realization of coherent coupling between incoherent (thermal) magnons is important for advancing energy-efficient magnonic devices, particularly in classical as well as quantum spin-wave computing technologies.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Search for monopole-dipole interactions with atom interferometry

Light, weakly coupled bosonic particles such as axions can mediate long range monopole-dipole interactions between matter and spins. We propose a new experimental method to detect such a force exerted by the spin of electrons on a freely falling atom using atom interferometry. The intrinsic advantages of atom interferometry, such as the freely falling nature of the atom and the well-defined response of the atom to external magnetic fields, should enable the proposed method to overcome systematic effects induced by vibrations, magnetic fields, and gravity. This approach is most suited to probe forces with a range ≳ 10 cm. With current technology, our proposed setup could potentially extend probes of such forces by an order of magnitude beyond present laboratory limits.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Excimer laser processing of backside-illuminated CCDS

An excimer laser is used to activate previously implanted dopants on the backside of a backside-illuminated CCD. The controlled ion implantation of the backside and subsequent thin layer heating and recrystallization by the short wavelength pulsed excimer laser simultaneously activates the dopant and anneals out implant damage. This improves the dark current response, repairs defective pixels and improves spectral response. This process heats a very thin layer of the material to high temperatures on a nanosecond time scale while the bulk of the delicate CCD substrate remains at low temperature. Excimer laser processing backside-illuminated CCD's enables salvage and utilization of otherwise nonfunctional components by bringing their dark current response to within an acceptable range. This process is particularly useful for solid state imaging detectors used in commercial, scientific and government applications requiring a wide spectral response and low light level detection.

Russell, S. D.↗

Radar Range Sidelobe Reduction Using Adaptive Pulse Compression Technique

Pulse compression has been widely used in radars so that low-power, long RF pulses can be transmitted, rather than a highpower short pulse. Pulse compression radars offer a number of advantages over high-power short pulsed radars, such as no need of high-power RF circuitry, no need of high-voltage electronics, compact size and light weight, better range resolution, and better reliability. However, range sidelobe associated with pulse compression has prevented the use of this technique on spaceborne radars since surface returns detected by range sidelobes may mask the returns from a nearby weak cloud or precipitation particles. Research on adaptive pulse compression was carried out utilizing a field-programmable gate array (FPGA) waveform generation board and a radar transceiver simulator. The results have shown significant improvements in pulse compression sidelobe performance. Microwave and millimeter-wave radars present many technological challenges for Earth and planetary science applications. The traditional tube-based radars use high-voltage power supply/modulators and high-power RF transmitters; therefore, these radars usually have large size, heavy weight, and reliability issues for space and airborne platforms. Pulse compression technology has provided a path toward meeting many of these radar challenges. Recent advances in digital waveform generation, digital receivers, and solid-state power amplifiers have opened a new era for applying pulse compression to the development of compact and high-performance airborne and spaceborne remote sensing radars. The primary objective of this innovative effort is to develop and test a new pulse compression technique to achieve ultrarange sidelobes so that this technique can be applied to spaceborne, airborne, and ground-based remote sensing radars to meet future science requirements. By using digital waveform generation, digital receiver, and solid-state power amplifier technologies, this improved pulse compression technique could bring significant impact on future radar development. The novel feature of this innovation is the non-linear FM (NLFM) waveform design. The traditional linear FM has the limit (-20 log BT -3 dB) for achieving ultra-low-range sidelobe in pulse compression. For this study, a different combination of 20- or 40-microsecond chirp pulse width and 2- or 4-MHz chirp bandwidth was used. These are typical operational parameters for airborne or spaceborne weather radars. The NLFM waveform design was then implemented on a FPGA board to generate a real chirp signal, which was then sent to the radar transceiver simulator. The final results have shown significant improvement on sidelobe performance compared to that obtained using a traditional linear FM chirp.

Li, Lihua↗

Application of X-Ray Pulsar Navigation: A Characterization of the Earth Orbit Trade Space

The potential for pulsars as a navigation source has been studied since their discovery in 1967. X-ray pulsar navigation (XNAV) is a celestial navigation system that uses the consistent timing nature of x-ray photons from milli-second pulsars (MSP) to perform space navigation. By comparing the detected arrival of x-ray photons to a reference database of expected pulsar lightcurve timing models, one can infer a range and range rate measurement based on light time delay. Much of the challenge of XNAV comes from the faint signal, availability, and distant nature of pulsars. This is a study of potential pulsar XNAV measurements to measure extended Kalman filter (EKF) tracking performance with a wide trade space of bounded Earth orbits, using a simulation of existing x-ray detector space hardware. An example of an x-ray detector for XNAV is the NASA Station Explorer for X-ray Timing and Navigation (SEXTANT) mission, a technology demonstration of XNAV set to perform on the International Space Station (ISS) in late 2016early 2017. XNAV hardware implementation is driven by trajectory and environmental influences which add noise to the x-ray pulse signal. In a closed Earth orbit, the radiation environment can exponentially increase the signal noise from x-ray pulsar sources, decreasing the quality and frequency of measurements. The SEXTANT mission in particular improves on the signal to noise ratio by focusing an array of 56 x-ray silicon drift detectors at one pulsar target at a time. This reduces timing glitches and other timing noise contributions from ambient x-ray sources to within a 100 nanosecond resolution. This study also considers the SEXTANT scheduling challenges inherent in a single target observation. Finally, as the navigation sources are now relatively inertial targets, XNAV measurements are also subject to periods of occultation from various celestial bodies. This study focuses on the characterization of these drivers in closed Earth orbits and is not a tuning analysis of the EKF. The study shows that the closed Earth orbit for XNAV performance is reliant on the orbit semi-major axis and eccentricity as well as orbit inclination. These parameters are the primary drivers of pulsar measurement availability and significantly influence the natural spacecraft orbit dynamics. Sensitivity to initial orbit determination error growth due to the scarcity of XNAV measurements within an orbital period require appropriate timing of initial XNAV measurements. The orbit angles of argument of perigee and right ascension of the ascending node, alongside the other orbit parameters, complete the initial cadence of XNAV measurements. The performance of initial XNAV measurements then propagates throughout the experimental period. The study provides a basis to missions who wish to consider XNAV as a potential navigation source in a closed Earth orbit design. It provides a family of orbit trajectories as well as other modeling considerations needed to effectively evaluate if XNAV is an effective navigation source for a potential mission. As an EKF is sensitive to a linearized estimated state, this study has a direct benefit of providing effective XNAV measurements to maintain spacecraft tracking, independent of other navigation sources. In the particular use case of the SEXTANT mission, it also provides a novel scheduling algorithm which addresses the need to prioritize and manage pulsar observations for effective navigation.

PULSAR↗

NASA SEXTANT Mission Operations Architecture

The Station Explorer for X-Ray Timing and Navigation (SEXTANT) mission is a technology demonstration enhancement to the Neutron Star Interior Composition Explorer (NICER) mission, a NASA Astrophysics Explorer Mission of Opportunity to the International Space Station (ISS) that was launched in June of 2017. The NICER instrument is a precision pointing X-ray telescope that times pulsar sourced photon arrivals which the SEXTANT mission uses to perform autonomous onboard X-ray Pulsar Navigation (XNAV). By comparing the detected time of arrival of X-ray photons to a reference of expected pulsar timing models, one can infer a range and range rate measurement based on light time delay. Since both timing and orientation information comes from a celestial source, this technology could provide a GPS-like navigation capability available throughout our Solar System and beyond. Applications that XNAV can support include outer planet and interstellar missions, manned missions, libration orbit missions, and current infrastructure such as the Deep Space Network (DSN). The SEXTANT team successfully completed a first demonstration of in-space and autonomous XNAV in November 2017. NICER and SEXTANT have separate teams, with NICER being the primary team with its own science objectives. Operational modes for both missions must have concurrent and independent components as well as an integrated ground system. This paper describes on the operational infrastructure and successful operations for performing X-ray Pulsar Navigation with the Station Explorer for X-ray Timing and Navigation Technology (SEXTANT) demonstration. This paper first details the infrastructure implemented, then the concept of operations, and finally the operations for the SEXTANT demonstration and lessons learned.

Ground Systems↗

Search for Eccentric Binary Black Hole Mergers with Advanced LIGO and Advanced Virgo during Their First and Second Observing Runs

When formed through dynamical interactions, stellar-mass binary black holes (BBHs) may retain eccentric orbits (e > 0.1 at 10 Hz) detectable by ground-based gravitational-wave detectors. Eccentricity can therefore be used to differentiate dynamically formed binaries from isolated BBH mergers. Current template-based gravitational-wave searches do not use waveform models associated with eccentric orbits, rendering the search less efficient for eccentric binary systems. Here we present the results of a search for BBH mergers that inspiral in eccentric orbits using data from the first and second observing runs (O1 and O2) of Advanced LIGO and Advanced Virgo. We carried out the search with the coherent WaveBurst algorithm, which uses minimal assumptions on the signal morphology and does not rely on binary waveform templates. We show that it is sensitive to binary mergers with a detection range that is weakly dependent on eccentricity for all bound systems. Our search did not identify any new binary merger candidates. We interpret these results in light of eccentric binary formation models. We rule out formation channels with rates ≳100 Gpc−3 yr−1 for e > 0.1, assuming a black hole mass spectrum with a power-law index ≲2.

B. P. Abbott↗

A low noise CMOS camera system for 2D resonant inelastic soft X-ray scattering

Resonant Inelastic X-ray Scattering (RIXS) is a powerful spectroscopic technique to study quantum properties of materials in the bulk. A novel variant of RIXS, called 2D RIXS, enables concurrent measurement of the scattered X-ray spectrum for a wide range of input energies, improving on the typically low throughput of 1D RIXS. In the soft X-ray domain, 2D RIXS demands an X-ray camera system with small pixels, large area, high quantum efficiency and low noise to limit the false detection rate in long duration exposures. We designed and implemented a 7.5 Megapixel back-illuminated CMOS detector with 5 μm pixels and high quantum efficiency in the 200–1,000 eV X-ray energy range for the QERLIN 2D RIXS spectrometer at the Advanced Light Source. The QERLIN beamline and detector are currently in commissioning. The camera noise from in-situ 3 s long dark exposures is 7e - or less and the leakage current is 6.5 × 10 -3 e - /(pixel ∙ s). For individual 500 eV X-rays, the expected efficiency is greater than 75% and the false detection rate is ~1 × 10 -5 per pixel.

47 OTHER INSTRUMENTATION↗

Searching for high-frequency gravitational waves with phonons

The gravitational wave (GW) spectrum at frequencies above a kHz is a largely unexplored frontier. We show that detectors with sensitivity to single-phonon excitations in crystal targets can search for GWs with frequencies, 1 THz ≲ f ≲ 100 THz , corresponding to the range of optical phonon energies, 1 meV ≲ ω ≲ 100 meV . Such detectors are already being built to search for light dark matter (DM), and therefore sensitivity to high-frequency GWs will be achieved as a byproduct. We begin by deriving the absorption rate of a general GW signal into single phonons. We then focus on carefully defining the detector sensitivity to monochromatic and chirp signals, and compute the detector sensitivity for many proposed light DM detection targets. The detector sensitivity is then compared to the signal strength of candidate high-frequency GW sources, e.g., superradiant annihilation and black hole inspiral, as well as other recent detector proposals in the 1 MHz ≲ f ≲ 100 THz frequency range. With a judicious choice of target materials, a collection of detectors could optimistically achieve sensitivities to monochromatic signals with h 0 ∼ 10 − 23 − 10 − 25 over 1 THz ≲ f ≲ 100 THz . Published by the American Physical Society 2024

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Near-field probing of strong light-matter coupling in single IR antennae

Quantum well intersubband polaritons are traditionally studied in large scale ensembles, over many wavelengths in size.In this presentation, we demonstrate that it is possible to detect and investigate intersubband polaritons in a single sub-wavelength nanoantenna in the IR frequency range. We observe polariton formation using a scattering-type near-fieldmicroscope and nano-FTIR spectroscopy. In this work, we will discuss near-field spectroscopic signatures of plasmonic antennae withand without coupling to the intersubband transition in quantum wells located underneath the antenna. Evanescent fieldamplitude spectra recorded on the antenna surface show a mode anti-crossing behavior in the strong coupling case. Wealso observe a corresponding strong-coupling signature in the phase of the detected field. We anticipate that this near-fieldapproach will enable explorations of strong and ultrastrong light-matter coupling in the single nanoantenna regime,including investigations of the elusive effect of ISB polariton condensation.

36 MATERIALS SCIENCE↗