Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “laser interference”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Colliding Pulse Mode Locking and Nonequilibrium Carrier Dynamics within Vertical External-Cavity Surface-Emitting Lasers

The complex nonlinear dynamics of colliding counterpropagating ultrashort laser pulses circulating in a vertical external-cavity surface-emitting ring laser cavity are captured by a first-principles quantum-mechanical microscopic model coupled to an intracavity beam propagator. Furthermore, our numerical simulations establish that overall mode locking stability is sensitive to relative phases and delays of the pulses impinging on the semiconductor saturable absorber mirror. Delay offsets of the counterpropagating pulses lead to asymmetric carrier recovery and instability, often leading in turn to single unidirectional circulating pulses. Although computationally challenging, we also include transverse effects and show that the influence of interference patterns from spatial gratings written by the counterpropagating pulses is significant in stabilizing the modelocked pulses.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Analysis of the Amplitude Response of a Two-Point and a Multi-Point Focused Laser Differential Interferometer

Experiments were performed with two different focused laser differential interferometer (FLDI) instruments to assess the relative amplitude response of each instrument to a traveling shockwave generated by a laser spark in air. The first FLDI instrument generated two slightly-separated measurement points, with each measurement point providing sensitivity to density fluctuations induced by the shockwave. By performing a cross-correlation between the signals obtained from each measurement point, the phase velocity of density fluctuations can be obtained. The second FLDI instrument generated a measurement line that was oriented parallel to the shockwave direction of travel with the resulting interference pattern sampled at multiple equally-spaced points along the line. As a result, this instrument provides density fluctuation measurement capability at multiple points simultaneously. When the measurement line is oriented parallel to the shockwave direction of travel, the phase velocity, rate of change of the phase velocity, and acceleration of density fluctuations traveling along each line can be obtained by performing a cross-correlation between points along the line. Numerical computations of the shockwave generated by the laser spark are used to simulate the response of each instrument and are compared to the experimental results. High-speed schlieren imaging has also been performed and is compared with the FLDI measurements and computational results.

Brett F. Bathel↗

Analysis of the Amplitude Response of a Two-Point and a Multi-Point Focused Laser Differential Interferometer

Experiments were performed with two different focused laser differential interferometer (FLDI) instruments to assess the relative amplitude response of each instrument to a traveling shockwave generated by a laser spark in air. The first FLDI instrument generated two slightly-separated measurement points, with each measurement point providing sensitivity to density fluctuations induced by the shockwave. By performing a cross-correlation between the signals obtained from each measurement point, the phase velocity of density fluctuations can be obtained. The second FLDI instrument generated a measurement line that was oriented parallel to the shockwave direction of travel with the resulting interference pattern sampled at multiple equally-spaced points along the line. As a result, this instrument provides density fluctuation measurement capability at multiple points simultaneously. When the measurement line is oriented parallel to the shockwave direction of travel, the phase velocity, rate of change of the phase velocity, and acceleration of density fluctuations traveling along each line can be obtained by performing a cross-correlation between points along the line. Numerical computations of the shockwave generated by the laser spark are used to simulate the response of each instrument and are compared to the experimental results. High-speed schlieren imaging has also been performed and is compared with the FLDI measurements and computational results.

Interferometry↗

Virtual Diagnostics Interface (ViDI) for Planning Laser-Based Wind Tunnel Experiments

Virtual Diagnostics Interface (ViDI), originally introduced by Richard Schwartz in 2004 and described again by Alderfer, et. al., in 2007, is an interactive 3D software tool developed at NASA Langley Research Center to serve three main purposes: assist in pre-test planning, enhance post-test image analysis and visualization, and serve as a central location for data storage and distribution.1,2 ViDI is composed of custom-developed software and Autodesk® 3ds Max® as it incorporates Computer Aided Design (CAD) models with the results obtained from optical diagnostics.3 This software tool has proven useful in the field of optical diagnostics where pre-test planning of beam paths, optical elements, and test articles must be carried out to avoid interference, ensure spatial resolution is sufficient, and the camera Field of View (FoV) is adequate for the field of interest. Typically, practical considerations such as the distance a camera is from the region of interest, the angles at which the camera is oriented and issues such as the size of the camera and its sensor and size and focal length lens as well as the path of the laser need to be taken into account to predict a successful measurement. An example application of ViDI is shown in Fig.1 where an experiment to investigate flow separation over the wing of the High Lift Common Research Model (HL-CRM) is currently being planned in the National Transonic Facility (NTF) at NASA Langley Research Center.

virtual diagnostics interface↗

Local enhancement in transient absorption spectroscopy by gating the resonance in the time domain

The concept of resonant perfect absorption, enabled by the combined action of pulse propagation and an auxiliary gate pulse, was recently proposed and demonstrated in a group of two-level systems [Y. He , ]. Here we exploit this method in a more realistic scenario by solving the coupled time-dependent Schrödinger equation and the Maxwell wave equation in helium. Through emptying the population of the 1 s 2 p excited state after its excitation, we explore the evolution of the spectral profile with time delay and propagation distance and link the observations to the controlled interference between the original field and the gated new field. We find that resonant absorption for higher-lying states can also be strongly enhanced, in spite of the congestion of multiple resonances and the presence of complex laser-induced couplings. Our results show that interferometric control of absorption using intense laser fields can be applied selectively in both the temporal and spatial domains. Published by the American Physical Society 2024

He, Yu (ORCID:0000000152120176)↗

Third-generation FAGE instrument for tropospheric hydroxyl radical measurement

A single-stage, frequency-doubled, copper vapor laser-pumped dye laser has been constructed to be used in the measurement of atmospheric hydroxyl radical concentrations. A new photon counting instrument is used for HO fluorescence detection. Theoretical and experimental studies of instrument performance show better sensitivities and reduced photolytic interferences than have been possible with previous systems based upon Nd:YAG pumping.

Chan, C. Y.↗

Molecular Rayleigh Scattering Diagnostic for Measurement of High Frequency Temperature Fluctuations

A novel technique for measurement of high frequency temperature fluctuations in unseeded gas flows using molecular Rayleigh scattering is investigated. The spectrum of laser light scattered from molecules in a gas flow is resolved using a Fabry-Perot interferometer. The width of the spectral peak is broadened by thermal motion of the molecules and hence is related to gas temperature. The interference fringe pattern containing spectral information is divided into four concentric regions using a series of mirrors angled with respect to one another. Light from each of these regions is directed towards photomultiplier tubes and sampled at 10 kHz using photon counting electronics. Monitoring the relative change in intensity within each region allows measurement of gas temperature. Independently monitoring the total scattered intensity provides a measure of gas density. This technique also has the potential to simultaneously measure a single component of flow velocity by monitoring the spectral peak location. Measurements of gas temperature and density are demonstrated using a low speed heated air jet surrounded by an unheated air co-flow. Mean values of temperature and density are shown for radial scans across the jet flow at a fixed axial distance from the jet exit plane. Power spectra of temperature and density fluctuations at several locations in the jet are also shown. The instantaneous measurements have fairly high uncertainty; however, long data records provide highly accurate statistically quantities, which include power spectra. Mean temperatures are compared with thermocouple measurements as well as the temperatures derived from independent density measurements. The accuracy for mean temperature measurements was +/- 7 K.

Mielke, Amy F.↗

Laser Sounder for Global Measurement of CO2 Concentrations in the Troposphere from Space: Progress

We describe progress toward developing a laser-based technique for the remote measurement of the tropospheric CO2 concentrations from orbit. Our goal is to demonstrate a lidar technique and instrument technology that will permit measurements of the CO2 column abundance in the lower troposphere from aircraft at the few ppm level, with a capability of scaling to permit global CO2 measurements from orbit. Accurate measurements of the tropospheric CO2 mixing ratio from space are challenging due to the many potential error sources. These include possible interference from other trace gas species, the effects of temperature, clouds, aerosols & turbulence in the path, changes in surface reflectivity, and variability in dry air density caused by changes in atmospheric pressure, water vapor and topographic height. Some potential instrumental errors include frequency drifts in the transmitter, small transmission and sensitivity drifts in the instrument. High signal-to-noise ratios and measurement stability are needed for mixing ratio estimates at the few ppm level. We have been developing a laser sounder approach as a candidate for a future space mission. It utilizes multiple different laser transmitters to permit simultaneous measurement of CO2 and O2 extinction, and aerosol backscatter in the same measurement path. It directs the narrow co-aligned laser beams from the instrument's fiber lasers toward nadir, and measures the energy of the strong laser echoes reflected from the Earth's land and water surfaces. During the measurement its narrow linewidth lasers are rapidly tuned on- and off- selected CO2 line near 1572 nm and an O2 absorption line near 770 nm. The receiver measures the energies of the laser echoes from the surface and any clouds and aerosols in the path with photon counting detectors. Ratioing the on- to off-line echo pulse energies for each gas permits the column extinction and column densities of CO2 and O2 to be estimated simultaneously via the differential absorption lidar technique. For the on-line wavelengths, the side of the selected absorption lines are used, which due to pressure broadening, weights the measurements to the lower troposphere, where CO2 variations caused by surface sources and sinks are largest. Simultaneous measurements of O2 column abundance are made using an identical approach using an O2 line. The laser backscatter profiles from clouds and aerosols are measured with other lidar channels, which permits identifying measurements influenced by clouds and/or aerosol scattering in the path. For space use, our lidar would continuously measure at nadir in near polar circular orbit. Using dawn and dusk measurements made over the same region will make it possible to sample the diurnal variations in CO2 mixing ratios. A 1-m diameter telescope is used for the receiver for all wavelengths. When averaging over 50 seconds, our calculations show a SNR of approximately 1500 is achievable for each gas at each on- and off-line measurement. Measurements from such a mission can be used to generate monthly global maps of the lower tropospheric CO2 column abundance. Our calculations show global coverage with an accuracy of a few ppm with a spatial resolution of approximately 50,000 sq. km are achievable each month. We have demonstrated some key elements of the laser, detector and receiver approaches in the laboratory and with measurements over a 206 m horizontal path. These include stable measurements of CO2 line shapes in an absorption cell using a fiber laser amplifier seeded by a tunable diode laser, measurement of small amplitude changes at low optical signal levels with the PMT receiver, and comparison of the horizontal path measurements of CO2 against those from an in-situ instrument.

Abshire, J. B.↗

Genetic-algorithm retrieval of the molecular alignment distribution with high-order harmonics generated from transiently aligned CO 2 molecules

Using genetic algorithm, we propose a method to retrieve the alignment distribution of transiently aligned CO 2 molecules from the high-order harmonic generation (HHG) spectra. The retrieval method is based on the quantitative rescattering (QRS) model where averaged photorecombination transition dipole can be factored out from the parallel (or perpendicular) harmonic spectra after the propagation of the harmonic fields in the gas medium. We examine how the retrieved alignment distributions are affected by uncertainty in alignment dependent ionization probability and on multiple orbital contribution to the HHG. We further confirm that alignment distribution is more accurately retrieved by using the minima in the HHG spectra driven by a long-wavelength laser. In addition, we show that earlier experimental data on the ratios between the perpendicular and the parallel HHG components of aligned CO 2 molecules are in better agreement with the QRS model if the macroscopic propagation and multiple orbital interference are included in the theoretical calculation.

74 ATOMIC AND MOLECULAR PHYSICS↗

Remote water quality measurements with a lidar polarimeter

A lidar polarimeter system utilizing a 5 mw He-Ne laser has been constructed and used for laboratory and day light backscatter measurements from suspensions of teflon particles and absorbing dye in water. The results of this study have shown that a lidar polarimeter system can measure 'volume reflectance' without interference of peripheral effects such as sky reflections. The polarization ratio appears to be less affected by surface waves than does the total intensity or individual polarizations. The cross polarized return is the most sensitive to changes in the single scatter albedo and absolute concentrations of absorbing and scattering materials. A criterion is indicated which states that finite beam effects must be considered when the total extinction length is greater than the incident beam width.

Wilhelmi, G. J.↗

Characteristics of merging shear layers and turbulent wakes of a multi-element airfoil

Flow characteristics in the vicinity of the trailing edge of a single-slotted airfoil flap are presented and analyzed. The experimental arrangement consisted of a NACA 4412 airfoil equipped with a NACA 4415 flap whose angle of deflection was 21.8 deg. The flow remained attached over the model surfaces except in the vicinity of the flap trailing edge where a small region of boundary-layer separation extended over the aft 7 percent of flap chord. The flow was complicated by the presence of a strong, initially inviscid jet emanating from the slot between airfoil and flap, and a gradual merging of the main airfoil wake and flap suction-side boundary layer. Downstream of the flap, the airfoil and flap wakes fully merged to form an asymmetrical curved wake. The airfoil configuration was tested at an angle of attack of 8.2 deg, at a Mach number of 0.09, and a chord based Reynolds number of 1.8 x 10 to the 6th power in the Ames Research Center 7- by 10-Foot Wind Tunnel. Surface pressure measurements were made on the airfoil and flap and on the wind tunnel roof and floor. It was estimated that the wall interference increased the C sub L by 7 percent and decreased the C sub M by 4.5 percent. Velocity characteristics were quantified using hot-wire anemometry in regions of flow with preferred direction and low turbulence intensity. A 3-D laser velocimeter was used in regions of flow recirculation and relatively high turbulence intensity.

Adair, Desmond↗

Two-Color Laser Speckle Shift Strain Measurement System

A two color laser speckle shift strain measurement system based on the technique of Yamaguchi was designed. The dual wavelength light output from an Argon Ion laser was coupled into two separate single-mode optical fibers (patchcords). The output of the patchcords is incident on the test specimen (here a structural fiber). Strain on the fiber, in one direction, is produced using an Instron 4502. Shifting interference patterns or speckle patterns will be detected at real-time rates using 2 CCD cameras with image processing performed by a hardware correlator. Strain detected in fibers with diameters from 21 microns to 143 microns is expected to be resolved to 15 mu epsilon. This system was designed to be compact and robust and does not require surface preparation of the structural fibers.

Tuma, Margaret L.↗

Imaging Fluorescent Combustion Species in Gas Turbine Flame Tubes: On Complexities in Real Systems

Planar laser-induced fluorescence (PLIF) is used to visualize the flame structure via OH, NO, and fuel imaging in kerosene- burning gas turbine combustor flame tubes. When compared to simple gaseous hydrocarbon flames and hydrogen flames, flame tube testing complexities include spectral interferences from large fuel fragments, unknown turbulence interactions, high pressure operation, and the concomitant need for windows and remote operation. Complications of these and other factors as they apply to image analysis are considered. Because both OH and gas turbine engine fuels (commercial and military) can be excited and detected using OH transition lines, a narrowband and a broadband detection scheme are compared and the benefits and drawbacks of each method are examined.

Hicks, Y. R.↗

Lunar Payloads to Constrain Exospheric Water through the NASA M-STAR program

Our understanding of water cycles on the Moon has significantly enhanced recent observations by Chang E-5, Lunar Prospector, and Chandrayaan-1 missions indicating the existence of an active water cycle on the Moon. In a new partnership between Delaware State University (DSU) and NASA Goddard Space Flight Center, enabled through the NASA’s M-STAR (MUREP Space Technology Artemis Research) program, we are developing low mass and power lunar rover payloads to enable long-duration human exploration missions. Payload technologies include wavelength modulation absorption spectroscopy to simultaneously detect water (H16OH) and isotopes (H16OD) in the (6700 nm) mid-infrared region using a closed path in compact Herriot cell optical design and wavelength modulation spectroscopy, and (2) Laser-induced breakdown spectroscopy (LIBS) to simultaneously detect and correlate water isotopes with characteristics elemental composition of lunar regolith. Due to the airless atmosphere of the Moon, we will utilize Artificial intelligence (AI) and Machine learning (ML) approaches to discriminate spectral interference with instrument drifts and correlate mid-IR trace gas profile with LIBS spectral information. This partnership will initiate a STEM engagement space program, e.g., Lander and CubeSat payload technology development for students and the next-generation NASA workforce for future lunar and Mars missions. DSU, a Historically Black University, prides itself in its proven excellence in teaching and research. It enrolls a diverse population of students (~5000) traditionally underrepresented in STEM disciplines. DSU has established itself at the forefront of optics and photonics research that transcends multidisciplinary fields of earth sciences, environmental, defense, and biomedical sensing applications.

water cycles↗

Laser-Based Flowfield Imaging in a Lean Premixed Prevaporized Sector Combustor

OH and fuel planar laser-induced fluorescence (PLIF) is used qualitatively in this study to observe the flame structure resultant from different fuel injector dome configurations within the 3-cup sector combustor test rig. The fluorescence images are compared with some computational fluid dynamics (CFD) results. Interferences in obtaining OH fluorescence signals due to the emission of other species are assessed. NO PLIF images are presented and compared to gas analysis results. The comparison shows that PLIF NO can be an excellent method for measuring NO in the flame. Additionally, we present flow visualization of the molecular species C2.

Hicks, Yolanda R.↗

Tunable-diode laser absorption spectrometry

Tunable-diode laser absorption spectrometry (TDLAS) affords a number of advantages for atmospheric measurements. It is a universal method, applicable, in principle, to all gases of atmospheric interest. Because of its extremely high spectral resolution it provides unequivocal identification of the target species, with no interferences from other gases. It provides real-time, in situ measurements with time resolutions better than 1 minute. The sensitivity of the current TDLAS system is marginally capable of measuring HO2. This species exists in the troposphere at concentrations which are up to 2 orders of magnitude higher than those of HO and, in addition, is much less susceptible to removal by the surfaces of the instrument and its sampling system. HO2 is an important HO sub x species in its own right but can also give direct information on the HO concentration by virtue of the rapid partitioning between these two species. The addition of the high-frequency modulation technique to the TDLAS system would ensure its ability to measure HO2 under most atmospheric conditions. The ability of the TDLAS to measure hydrogen peroxide (H2O2) in the ambient atmosphere was also demonstrated. H2O2 measurements give a clear indication of HO sub x mixing ratios and are also important as a photolytic source of HO and as an important oxidant for other atmospheric consitituents such as SO2.

Schiff, H. I.↗

Experimental Determination of Spinel/Melt, Olivine/Melt, and Pyroxene/Melt Partition Coefficients for Re, Ru, Pd, Au, and Pt

Experimental studies have identified spinels as important hosts phases for many of the highly siderophile elements (HSE). Yet experimental studies involving chromite or Cr-rich spinel have been lacking. Experimental studies of partitioning of HSEs between silicate, oxides and silicate melt are plagued by low solubilities and the presence of small metallic nuggets at oxygen fugacities relevant to magmas, which interfere with analysis of the phases of interest. We have circumvented these problems in two ways: 1) performing experiments at oxidized conditions, which are still relevant to natural systems but in which nuggets are not observed, and 2) analysis of run products with laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS), allowing a combination of high sensitivity and good spatial resolution.

Righter, K.↗

The Least-Squares Calibration on the Micro-Arcsecond Metrology Test Bed

The Space Interferometry Mission (S1M) will measure optical path differences (OPDs) with an accuracy of tens of picometers, requiring precise calibration of the instrument. In this article, we present a calibration approach based on fitting star light interference fringes in the interferometer using a least-squares algorithm. The algorithm is first analyzed for the case of a monochromatic light source with a monochromatic fringe model. Using fringe data measured on the Micro-Arcsecond Metrology (MAM) testbed with a laser source, the error in the determination of the wavelength is shown to be less than 10pm. By using a quasi-monochromatic fringe model, the algorithm can be extended to the case of a white light source with a narrow detection bandwidth. In SIM, because of the finite bandwidth of each CCD pixel, the effect of the fringe envelope can not be neglected, especially for the larger optical path difference range favored for the wavelength calibration.

interferometer calibrations↗