Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “isolation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Mechanical strain isolator mount

Certain devices such as optical instruments must preserve their alignmental integrity while being subjected to mechanical strain. A mechanical strain isolator mount is provided to preserve the alignmental integrity of an alignment sensitive instrument. An alignment sensitive instrument is mounted on a rectangular base. Flexural legs are connected at their proximal ends to the rectangular base. Flexural legs are also spaced parallel to the sides. Mounting pads are connected to the legs at the distal end and the mechanical strain isolator mount is attached to the substrate by means of threaded bolts. When a mounting pad and its respective leg is subjected to lateral strain in either the X or Y direction via the substrate, the respective leg relieves the strain by bending in the direction of the strain. An axial strain on a mounting pad in the Z direction is relieved by a rotational motion of the legs in the direction of the strain. When the substrate is stress free, the flexural legs return to their original condition and thus preserve the original alignment integrity of the alignment sensitive instrument.

James, Gordon E.↗

Thermally isolated deployable shield for spacecraft

A thermally isolated deployable shield for spacecraft is provided utilizing a plurality of lattice panels stowable generally against the craft and deployable to some fixed distance from the craft. The lattice panels are formed from replaceable shield panels affixed to lattice structures. The lattice panels generally encircle the craft providing 360 degree coverage therearound. Actuation means are provided from translating the shield radially outward from the craft and thermally isolating the shield from the craft. The lattice panels are relatively flexible, allowing the shield to deploy to variable diameters while retaining uniform curvature thereof. Restraining means are provided for holding the shield relatively tight in its stowed configuration. Close-out assemblies provide light sealing and protection of the annular spaces between the deployed shield and the crafts end structure.

Redmon, John W., Jr.↗

A new approach to controller design for microgravity isolation systems

A new method has been developed to design an active vibration isolation system for microgravity space experiments. This method yields the required controller transfer functions for a specified transmissibility. Hence, it is a straightforward task to guarantee that the desired vibration isolation performance is achieved at each frequency. The theory for such a controller design has been presented by considering a single degree of freedom system. The magnitude of the control force required by the new method has been found to be less than that used by a standard phase lead/lag compensator.

Sinha, A.↗

Microgravity vibration isolation: An optimal control law for the one-dimensional case

Certain experiments contemplated for space platforms must be isolated from the accelerations of the platforms. An optimal active control is developed for microgravity vibration isolation, using constant state feedback gains (identical to those obtained from the Linear Quadratic Regulator (LQR) approach) along with constant feedforward (preview) gains. The quadratic cost function for this control algorithm effectively weights external accelerations of the platform disturbances by a factor proportional to (1/omega)(exp 4). Low frequency accelerations (less than 50 Hz) are attenuated by greater than two orders of magnitude. The control relies on the absolute position and velocity feedback of the experiment and the absolute position and velocity feedforward of the platform, and generally derives the stability robustness characteristics guaranteed by the LQR approach to optimality. The method as derived is extendable to the case in which only the relative positions and velocities and the absolute accelerations of the experiment and space platform are available.

Hampton, R. D.↗

Fault detection and isolation for multisensor navigation systems

Increasing attention is being given to the problem of erroneous measurement data for multisensor navigation systems. A recursive estimator can be used in conjunction with a 'snapshot' batch estimator to provide fault detection and isolation (FDI) for these systems. A recursive estimator uses past system states to form a new state estimate and compares it to the calculated state based on a new set of measurements. A 'snapshot' batch estimator uses a set of measurements collected simultaneously and compares solutions based on subsets of measurements. The 'snapshot' approach requires redundant measurements in order to detect and isolate faults. FDI is also referred to as Receiver Autonomous Integrity Monitoring (RAIM).

Kline, Paul A.↗

Characterizing and testing a thermally isolating superconducting link for SAFIRE-like missions

The recent discovery of high temperature ceramic superconductors with transition temperatures above 90 K has opened the possibilities for new space applications. One application is the fabrication of an electrically conducting and thermally isolating electronic link to connect IR detectors to data acquisition electronics on remote sensing platforms. The Spectroscopy of the Atmosphere using Far Infra-Red Emission (SAFIRE) mission is an example of a platform which employs hybrid dewars and combines both mechanical and cryogenic liquid cooling. This new technology is limited by the heat conducted through sensor array leads that connect the electronics (at approximately 80 K) to the sensors (at approximately 4 K). This link must be made of material that has high electrical conductivity and high thermal resistance. The YBa2Cu3O(x) superconductor with a transition temperature, T(sub c), of 93 K can achieve these conflicting requirements. A link with these characteristics will improve the thermal isolation of IR detectors and will increase the lifetime of the cryogen. A reduction of the thermal load due to the link by a factor of four will increase the lifetime of a seven year mission by about one year.

Selim, Raouf L.↗

Mechanisms of the Space Active Vibration Isolation (SAVI)

The Space Active Vibration Isolation (SAVI) is a concept for vibration isolation of one body from another with simultaneous precise control in 6 Degrees Of Freedom (DOF). SAVI achieves this using a combination of electromechanical linear actuators and magnetic actuators. Other mechanisms of interest include a structure for simulating the body being pointed, an apparatus to simulate the body that is the vibration source, and mechanisms to off-load the weight of each of these two bodies from the experiment to approximate a zero-g condition. A SAVI was built and tested to demonstrate these capabilities.

Schmitt, Frank↗

Dynamics and control of high precision magnetically levitated vibration isolation systems

Vibration control of flexible structures has received a great deal of interest in recent years. Several authors have investigated this topic in the areas of robot manipulators, space structures, and flexible rotors. Key issues associated with the dynamics and control of vibration isolation systems are addressed. Among other important issues to consider in the control of such systems, the location and number of actuators and sensors are essential to effectively control and suppress vibration. We first address the selection of proper actuator and sensor locations leading to a controllable and observable system. The Rayleigh-Ritz modal analysis method is used to develop a lumped-parameter model of a flexible vibration isolation table top. This model is then used to investigate the system's controllability and observability including the coupling effects introduced by the magnetic bearing. This analysis results in necessary and sufficient conditions for proper selection of actuator and sensor locations. These locations are also important for both controller system's complexity and stability of point of views. A favorable pole-zero plot of the open loop transfer functions is presented. Necessary and sufficient conditions for reducing the controller complexity are derived. The results are illustrated by examples using approximate mode shape functions.

Youcef-Toumi, K.↗

A six degree-of-freedom Lorentz vibration isolator with nonlinear controller

The results of a phase 2 Small Business Innovation Research Program sponsored by MSFC are presented. Technology is developed for isolating acceleration sensitive microgravity experiments from structural vibration of a spacecraft, such as a space station. Two hardware articles are constructed: a six degree of freedom Lorentz force isolation and a one degree of freedom low acceleration testbed capable of tests at typical experiment accelerations.

Fenn, Ralph C.↗

The Microgravity Isolation Mount (MGIM): A Columbus facility for improving the microgravity quality of payloads

The Microgravity Isolation Mount (MGIM) is a facility for providing active vibration isolation for sensitive experiments on the Columbus Attached Laboratory and the Columbus Free-Flying Laboratory. The facility is designed to be accommodated in a standard Columbus rack, and it iterfaces with existing rack utility services. The design is based on a non-contact strategy, whereby the payload 'floats' inside the rack, and its position is controlled by a number of magnetic actuators. The main advantage of using this non-contact strategy is the improved microgravity quality available. The overall design of the facility and a description of its elements are given.

Owen, R. G.↗

Experiments on active isolation using distributed PVDF error sensors

A control system based on a two-channel narrow-band LMS algorithm is used to isolate periodic vibration at low frequencies on a structure composed of a rigid top plate mounted on a flexible receiving plate. The control performance of distributed PVDF error sensors and accelerometer point sensors is compared. For both sensors, high levels of global reduction, up to 32 dB, have been obtained. It is found that, by driving the PVDF strip output voltage to zero, the controller may force the structure to vibrate so that the integration of the strain under the length of the PVDF strip is zero. This ability of the PVDF sensors to act as spatial filters is especially relevant in active control of sound radiation. It is concluded that the PVDF sensors are flexible, nonfragile, and inexpensive and can be used as strain sensors for active control applications of vibration isolation and sound radiation.

Lefebvre, S.↗

Damping phenomena in a wire rope vibration isolation system

A study of the dynamic characteristics of a wire rope vibration isolation system constructed with helical isolators is presented. Emphasis is placed on the analytical modeling of damping mechanisms in the system. An experimental investigation is described in which the static stiffness curve, hysteresis curves, phase trajectories, and frequency response curves were obtained. A semi-empirical model having nonlinear stiffness, nth-power velocity damping, and variable Coulomb friction damping is developed and results are compared to experimental data. Conclusions about dynamic phenomena in the wire rope system are made based on the experimental and semi-empirical results.

Tinker, Michael L.↗

Optimal microgravity vibration isolation - An algebraic introduction

Certain experiments contemplated for space platforms must be isolated from the accelerations of the platforms. An optimal active control is developed for microgravity vibration isolation, using constant state feedback gains (identical to those obtained from the Linear Quadratic Regulator (LQR) approach) along with constant feedforward (preview) gains. The quadratic cost function for this control algorithm effectively weights external accelerations of the platform disturbances by a factor proportional to (1/omega) (exp 4). Low frequency accelerations (less than 50 Hz) are attenuated by greater than two orders of magnitude. The control relies on the absolute position and velocity feedback of the experiment and the absolute position and velocity feedforward of the platform, and generally derives the stability robustness characteristics quaranteed by the LQR approach to optimality. The method as derived is extendable to the case in which only the relative positions and velocities and the absolute accelerations of the experiment and space platform are available.

Hampton, R. D.↗

Controller design for microgravity vibration isolation systems

Control aspects of the vibration isolation problem of manned orbiters are investigated, and a viable robust control is proposed. The application of modern control theory to this problem, incorporating frequency-weighting and disturbance accommodation techniques, is investigated. The resulting controller achieves excellent performance for plants within a reasonable range of variations from the nominal. Robust stability and performance guarantees are measured by singular value and structured singular value checks, yielding guarantees on allowable real plant parameter uncertainties and on acceptable controller and sensor phase and gain variations. The problem of unmodeled HG modes is eliminated by using frequency weighting to reduce controller bandwidth. The method is applied successfully to the single-degree-of-freedom isolation problem.

Hampton, R. D.↗

Six-Degree-Of-Freedom Magnetic Vibration Isolator

Feedback control provides soft mount and damping of vibrations. Active magnetic suspension system centers inner structure in position and orientation with respect to principal Cartesian coordinate axes of base or outer structure, stationary with respect to building or vehicle. System helps to isolate suspended mass from vibrations of building or vehicle. Designed to isolate 500-kg experimental apparatus from vibrations of spacecraft, but also used on Earth, provided that its z axis vertical and system assisted by low-stiffness vertical spring that, in steady state, holds up inner structure at nominal vertical position.

Gerver, Michael J.↗

Fault detection and isolation

Erroneous measurements in multisensor navigation systems must be detected and isolated. A recursive estimator can find fast growing errors; a least squares batch estimator can find slow growing errors. This process is called fault detection. A protection radius can be calculated as a function of time for a given location. This protection radius can be used to guarantee the integrity of the navigation data. Fault isolation can be accomplished using either a snapshot method or by examining the history of the fault detection statistics.

Bernath, Greg↗

Machine learning techniques for fault isolation and sensor placement

Fault isolation and sensor placement are vital for monitoring and diagnosis. A sensor conveys information about a system's state that guides troubleshooting if problems arise. We are using machine learning methods to uncover behavioral patterns over snapshots of system simulations that will aid fault isolation and sensor placement, with an eye towards minimality, fault coverage, and noise tolerance.

Carnes, James R.↗

Metabolic response of environmentally isolated microorganisms to industrial effluents: Use of a newly described cell culture assay

An environmental application using a microtiter culture assay to measure the metabolic sensitivity of microorganisms to petrochemical effluents will be tested. The Biomedical Operations and Research Branch at NASA JSC has recently developed a rapid and nondestructive method to measure cell growth and metabolism. Using a colorimetric procedure the uniquely modified assay allows the metabolic kinetics of prokaryotic and eukaryotic cells to be measured. Use of such an assay if adapted for the routine monitoring of waste products, process effluents, and environmentally hazardous substances may prove to be invaluable to the industrial community. The microtiter method as described will be tested using microorganisms isolated from the Galveston Bay aquatic habitat. The microbial isolates will be identified prior to testing using the automated systems available at JSC. Sodium dodecyl sulfate (SDS), cadmium, and lead will provide control toxic chemicals. The toxicity of industrial effluent from two industrial sites will be tested. An effort will be made to test the efficacy of this assay for measuring toxicity in a mixed culture community.

Ferebee, Robert N.↗