Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ion trap”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Space Flyable Hg(sup +) Frequency Standards

We discuss a design for a space based atomic frequency standard (AFS) based on Hg(sup +) ions confined in a linear ion trap. This newly developed AFS should be well suited for space borne applications because it can supply the ultra-high stability of a H-maser but its total mass is comparable to that of a NAVSTAR/GPS cesium clock, i.e., about 11kg. This paper will compare the proposed Hg(sup +) AFS to the present day GPS cesium standards to arrive at the 11 kg mass estimate. The proposed space borne Hg(sup +) standard is based upon the recently developed extended linear ion trap architecture which has reduced the size of existing trapped Hg(sup +) standards to a physics package which is comparable in size to a cesium beam tube. The demonstrated frequency stability to below 10(sup -15) of existing Hg(sup +) standards should be maintained or even improved upon in this new architecture. This clock would deliver far more frequency stability per kilogram than any current day space qualified standard.

clocks cesium atomic frequency standard Hg ions li↗

A numerical study of suprathermal ionospheric ion trajectories in three-dimensional electric and magnetic field models

A numerical study of the magnetospheric trajectories of ions upflowing from the ionosphere has been performed using three-dimensional magnetic and electric field models. Ion trajectories have been divided into three main types corresponding to (1) gravitational ions trapped between the magnetic and gravitational mirror points and drifting nearly along the local electric equipotential, (2) ions just escaping from the gravitational field and then convected to the magnetopause due to the loss of the main part of their kinetic energy, and (3) trapped and pseudo-trapped ions whose trajectories are mainly determined by the magnetic field topology (beams and conics) because of their large kinetic energy. Particles from conic distributions injected at inadequate local times and/or altitudes to gain enough energy to precipitate reach the dayside magnetopause after several bounce periods.

Sauvaud, J. A.↗

Dissipation-assisted steady-state entanglement engineering based on electron transfer models

Here, we propose a series of dissipation-assisted entanglement generation protocols that can be implemented on a trapped-ion quantum simulator. Our approach builds on the single-site molecular electron transfer (ET) model recently realized in experiment [So et al., Sci. Adv. 10, eads8011 (2024)]. This model leverages spin-dependent boson displacement and dissipation controlled by sympathetic cooling. We show that, when coupled to external degrees of freedom, the ET model can be used as a dissipative quantum control mechanism, enabling the precise tailoring of both spin and boson steady states of a target subsystem. We derive simplified analytical formalisms that offer intuitive insights into the dissipative dynamics. Using realistic interactions in a trapped-ion system, we develop a protocol for generating 𝑁-qubit and 𝑁-boson 𝑊 states. Additionally, we generalize this protocol to realize generic 𝑁-qubit Dicke states with tunable excitation numbers. Finally, we outline a realistic experimental setup to implement our schemes in the presence of noise sources.

chemical charge transfer↗

Design and Demonstration of the Mars Organic Molecule Analyzer (MOMA) on the ExoMars 2018 Rover

The Mars Organic Molecule Analyzer (MOMA) investigation is a key astrobiology experiment scheduled to launch on the joint ESA-Roscosmos ExoMars 2018 rover mission. MOMA will examine the chemical composition of geological samples acquired from depths of up to two meters below the martian surface, where fragile organic molecules may be protected from destructive cosmic radiation and/or oxidative chemical reactions. The heart of the MOMA mass spectrometer subsystem (i.e., MOMA-MS) is a miniaturized linear ion trap (LIT) that supports two distinct modes of operation to detect: i) volatile and semi-volatile, low-to-moderate mass organics (less than or equal to 500 Da) via pyrolysis coupled with gas chromatography mass spectrometry (pyr/GCMS); and, ii) more refractory, moderate-to-high mass compounds (up to 1000 Da) via laser desorption (LDMS) at ambient Mars pressures. Additionally, the LIT mass analyzer enables selective ion trapping via multi-frequency waveform ion excitation (e.g., stored waveform inverse Fourier transform, or SWIFT), and structural characterization of complex molecules using tandem mass spectrometry (MSIMS). A high-fidelity Engineering Test Unit (ETU) of MOMAMS, including the LIT subassembly, dual-gun electron ionization source, micropirani pressure gauge, solenoid-driven aperture valve, redundant detection chains, and control electronics, has been built and tested at NASA GSFC under relevant operational conditions (pressure, temperature, etc.). Spaceflight qualifications of individual hardware components and integrated subassemblies have been validated through vibration, shock, thermal, lifetime, and performance evaluations. The ETU serves as a pathfinder for the flight model buildup, integration and test, as the ETU meets the form, fit and function of the flight unit that will be delivered to MPS in late 2015. To date, the ETU of MOMA-MS has been shown to meet or exceed all functional requirements, including mass range, resolution, accuracy, instrumental drift, and Iimit-of-detection specifications, thereby enabling the primary science objectives of the MOMA investigation and ExoMars 2018 mission.

Mars Organic Molecule Analyzer↗

Supramolecular Control of Ionic Retention in Electrolyte-Gated Synaptic Transistors

Electrolyte-gated transistors with ion-trapping layers offer a promising platform for artificial synapses in neuromorphic computing, yet molecular mechanisms governing ionic retention remain poorly understood. Here, in this study, we present a supramolecular approach to modulate ion retention by incorporating a crown ether derivative-based polymer network as an ion-trapping layer on top of a semiconducting monolayer. We show that the balance between ion–host binding and ion–solvent interactions dictates the kinetics of ion capture and release, which in turn controls the memory characteristics of the device. By varying the solvent dielectric constant, we tune the ionic retention time from nearly permanent trapping to rapid relaxation. Intermediate solvent polarity enables programmable short- and long-term synaptic behaviors, including excitatory postsynaptic current, paired-pulse facilitation, and long-term potentiation and depression. These findings establish a direct link between supramolecular ion recognition and synaptic plasticity and provide a generalizable design strategy for ionic–electronic neuromorphic devices.

36 MATERIALS SCIENCE↗

Gas phase protonated nicotine is a mixture of pyridine- and pyrrolidine-protonated conformers: implications for its native structure in the nicotinic acetylcholine receptor

The infrared (IR) spectra of gas phase protonated nicotine has been measured in the never-before probed N–H “fingerprint region” (3200–3500 cm -1 ). The protonated molecules generated by an electrospray source are thermalized in the first ion trap with water vapor and He gas at a pre-determined temperature prior to being probed by IR spectroscopy in the second ion trap at 4 K. The IR spectra exhibit two N–H stretching bands which are assigned to the pyridine and pyrrolidine protomers with the aid of high-level electronic structure calculations. This finding is in sharp contrast to previous spectroscopic studies that suggested a single population of the pyridine protomer. The relative populations of the two protomers vary by changing the temperature of the thermalizing trap from 180-300 K. The relative conformer populations at 240 K and 300 K are well reproduced by the theoretical calculations, unequivocally determining that gas phase nicotine is a 3 : 2 mixture of both pyridine and pyrrolidine protomers at room temperature. The thermalizing anhydrous vapor does not result in any population change. It rather demonstrates the catalytic role of water in achieving equilibrium between the two protomers. The combination of IR spectroscopy and electronic structure calculations establish the small energy difference between the pyridine and pyrrolidine protomers in nicotine. Finally, one of the gas phase nicotine pyrrolidine protomers has the closest conformational resemblance among all low-lying energy isomers with the X-ray structure of nicotine in the nicotinic acetylcholine receptor (nAChR).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Enhancement of vibrationally assisted energy transfer by proximity to exceptional points, probed by fluorescence-detected vibrational spectroscopy

Emulation of energy transfer processes in natural systems on quantum platforms can further our understanding of complex dynamics in nature. One notable example is the demonstration of vibrationally assisted energy transfer (VAET) on a trapped-ion quantum emulator, which offers insights for the energetics of light harvesting. In this work, we expand the study of VAET simulation with trapped ions to a non-Hermitian quantum system comprising a 𝒫⁢𝑇-symmetric chromophore dimer weakly coupled to a vibrational mode. We first characterize exceptional points (EPs) and non-Hermitian features of the excitation energy transfer processes in the absence of the vibration, finding a degenerate pair of second-order EPs. Exploring the non-Hermitian dynamics of the whole system including vibrations, we find that energy transfer accompanied by absorption of phonons from a vibrational mode can be significantly enhanced near such a degenerate EP. Our calculations reveal a unique spectral feature accompanying the coalescing of eigenstates and eigenenergies that provides a unique approach to probe the degenerate EP by fluorescence-detected vibrational spectroscopy. Enhancement of the VAET process near the EP is found to be due to maximal favorability of phonon absorption at the degenerate EP, enabling multiple simultaneous excitations. Our work on improving VAET processes in non-Hermitian quantum systems paves the way for leveraging non-Hermiticity in quantum dynamics related to excitation energy transfer.

Non-Hermitian systems↗

Modifying Operating Cycles to Increase Stability in a LITS

The short-term instability in the frequency of a linear-ion-trap frequency standard (LITS) can be reduced by modifying two cycles involved in its operation: (1) the bimodal (bright/dim) cycle of a plasma discharge lamp used for state preparation and detection and (2) a microwave-interrogation cycle. The purpose and effect of the modifications is to enable an increase in the microwave- interrogation cycle time, motivated by the general principle that the short-term uncertainty or instability decreases with increasing microwave-interrogation time. Stated from a slightly different perspective, the effect of modifications is to enable the averaged LITS readings to settle to their longterm stability over a shorter total observation time. The basic principles of a LITS were discussed in several NASA Tech Briefs articles. Here are recapitulated only those items of background information necessary to place the present modifications in context. A LITS includes a microwave local oscillator, the frequency of which is stabilized by comparison with the frequency of a ground-state hyperfine transition of Hg-199(+) ions. In a LITS of the type to which the modifications apply, the comparison involves a combination of optical and micro wave excitation and interrogation of the ions in two collinear ion traps: a quadrupole trap wherein the optical excitation used for state preparation and detection takes place, and a multipole (e.g., 12-pole) trap wherein the microwave interrogation of the clock transition takes place. The ions are initially loaded into the quadrupole trap and are thereafter shuttled between the two traps. This concludes the background information.

Burt, Eric↗

Evaluating Mass Analyzers as Candidates for Small, Portable, Rugged Single Point Mass Spectrometers for Analysis of Permanent Gases

For Space Shuttle launch safety, there is a need to monitor the concentration of H2, He, O2 and Ar around the launch vehicle. Currently a large mass spectrometry system performs this task, using long transport lines to draw in samples. There is great interest in replacing this stationary system with several miniature, portable, rugged mass spectrometers which act as point sensors which can be placed at the sampling point. Five commercial and two non-commercial analyzers are evaluated. The five commercial systems include the Leybold Inficon XPR-2 linear quadrupole, the Stanford Research (SRS-100) linear quadrupole, the Ferran linear quadrupole array, the ThermoQuest Polaris-Q quadrupole ion trap, and the IonWerks Time-of-Flight (TOF). The non-commercial systems include a compact double focusing sector (CDFMS) developed at the University of Minnesota, and a quadrupole ion trap (UF-IT) developed at the University of Florida. The System Volume is determined by measuring the entire system volume including the mass analyzer, its associated electronics, the associated vacuum system, the high vacuum pump and rough pump. Also measured are any ion gauge controllers or other required equipment. Computers are not included. Scan Time is the time required for one scan to be acquired and the data to be transferred. It is determined by measuring the time required acquiring a known number of scans and dividing by said number of scans. Limit of Detection is determined first by performing a zero-span calibration (using a 10-point data set). Then the limit of detection (LOD) is defined as 3 times the standard deviation of the zero data set. (An LOD of 10 ppm or less is considered acceptable.)

Arkin, C. Richard↗

Ultrafast High Voltage Kicker System Hardware for Ion Clearing Gaps

Jefferson Lab (JLab) will collaborate with Radiabeam, LLC in a DOE SBIR Phase II Project (DOE Grant No. DE-SC0019684, title: “Ultrafast High Voltage Kicker System Hardware for Ion Clearing Gaps”) to develop and test a MHz high voltage nanosecond kicker system that enables the time structure required by the ion traps for high current electron beam cooling. High current (in particular energy recovery) linac based electron cooling facilities for medium to high energy bunched proton or ion beams are of great interest for the recently funded Electron-Ion Collider (EIC) to which Jefferson Lab plays a critical role. The successful execution of this project will enable the capability to mitigate the ion trapping effect and circumvent a major obstacle preventing reliable operation of the crucial cooling facilities.

43 PARTICLE ACCELERATORS↗

Ultra-narrow-linewidth hybrid-integrated self-injection locked laser at 780 nm

Narrow-linewidth lasers are essential across a wide range of applications, including classical and quantum sensing, trapped ion systems, position/navigation/timing systems, optical clocks, and microwave frequency synthesizers. In the visible and near-visible spectrum, low-noise lasers are particularly important for laser trapping and cooling techniques, which are vital for trapped ion quantum computing, sensing, and atomic clocks. In this context, our work showcases a hybrid-integrated narrow-linewidth laser that operates at 780 nm, achieving a self-heterodyne linewidth of 105 Hz. To validate the experimental results, we performed a numerical analysis that combines insights from a many-body theory applied to the gain region with a travelling-wave model to capture the laser dynamics. Our investigation further delves into how the linewidth of the self-injection locked lasers is influenced by the parameters of micro-ring resonators, aiming to assess the potential for achieving Hz-level integrated laser linewidths at 780 nm. This work not only demonstrates the technical feasibility of Hz-level narrow-linewidth lasers but also lays the groundwork for future explorations in the field.

Prokoshin, Artem (ORCID:0009000699760238)↗

Effect of satellite potential on direct ion density measurements through the plasmapause

A simplified theory has been developed for calculating the effect of satellite potential on the ion current measured by an experiment such as an ion mass spectrometer or an ion trap. The theory is based on the use of a spherically symmetric Debye potential distribution in the sheath around the satellite and is particularly appropriate for use in regions where the Debye length is large, such as in the plasmasphere and magnetosphere. Ion data obtained from the ion trap on the Ogo 3 satellite during a pass through the plasmasphere show excellent agreement with the theory. The inferred ion densities from this analysis are as much as 1 order of magnitude different from what would be inferred from previous analyses.

Whipple, E. C.↗

Weak double layers

The characteristics of weak double layers with potential steps approximately equal to five are investigated in a triple plasma device and compared with a kinetic model. The double layers considered here differ from those previously investigated in two significant ways: (1) the double layers are much weaker; and (2) trapped ions play a much less important role. In this study, two plasmas at different potentials but with similar characteristics are separated from a target chamber by grids so that ions enter only at the high potential side and electron beams enter at the low potential side. What is more, thermal electrons enter at the high potential side and are trapped by the double layer. The model calculations illustrate the role of the trapped ions in determining the position of the double layer, and they demonstrate the dependence of the length of the double layer on the entering ion and electron fluxes.

Hershkowitz, N.↗

Evaluating Mass Analyzers as Candidates for Small, Portable, Rugged Single Point Mass Spectrometers for Analysis of Permanent Gases

For Space Shuttle launch safety, there is a need to monitor the concentration Of H2, He, O2, and Ar around the launch vehicle. Currently a large mass spectrometry system performs this task, using long transport lines to draw in samples. There is great interest in replacing this stationary system with several miniature, portable, rugged mass spectrometers which act as point sensors which can be placed at the sampling point. Five commercial and two non-commercial analyzers are evaluated. The five commercial systems include the Leybold Inficon XPR-2 linear quadrupole, the Stanford Research (SRS-100) linear quadrupole, the Ferran linear quadrupole array, the ThermoQuest Polaris-Q quadrupole ion trap, and the IonWerks Time-of-Flight (TOF). The non-commercial systems include a compact double focusing sector (CDFMS) developed at the University of Minnesota, and a quadrupole ion trap (UF-IT) developed at the University of Florida.

Arkin, C. Richard↗

Microhydration of the metastable N -Protomer of 4-Aminobenzoic acid by condensation at 80 K: H/D exchange without conversion to the more stable O- protomer

4-Aminobenzoic acid (4ABA) is a model scaffold for studying solvent-mediated proton transfer. Although protonation at the carboxylic group (O-protomer) is energetically favored in the gas phase, the N-protomer, where the proton remains on the amino group, can be kinetically trapped by electrospray ionization of 4ABA in an aprotic solvent such as acetonitrile. Here we report the formation of the hydrated deuterium isotopologues of the N-protomers, RND 3 + ·(H 2 O) n=1-3 , (R=C 6 H 4 COOD), which are generated by condensing water molecules onto the bare N-protomers in a liquid nitrogen cooled, radiofrequency octopole ion trap at 80 K. The product clusters are then transferred to a 20 K cryogenic ion trap where they are tagged with weakly bound D 2 molecules. The structures of these clusters are determined by analysis of their vibrational patterns obtained by resonant IR photodissociation. The resulting patterns confirm that the metastable N-protomer configuration remains intact even when warmed by sequential condensation of water molecules. Attachment of H 2 O molecules onto the RND 3 + head group also affords the opportunity to explore the possibility of H/D exchange between the acid scaffold and the proximal water network. The spectroscopic results establish that although the RND 3 + ·(H 2 O) n=1,2 clusters are formed without H/D exchange, the n = 3 cluster exhibits about 10% H/D exchange as evidenced by the appearance of the telltale HOD bands. Furthermore, the site of exchange on the acid is determined to be the acidic OH by the emergence of the OH stretching fundamental in the -COOH motif.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Numerical Investigation of Ion Transport in the MOMA Ion Mass Spectrometer

The Mars Organic Molecule Analyzer (MOMA) is a miniature ion trap mass spectrometer designed for the upcoming ExoMars Rover mission. The spectrometer uses laser desorption to ionize a Martian soil sample within an instrument internal clean zone maintained at ambient Martian pressure. A high-speed aperture valve transiently opens to allow ionized constituents, along with the ambient gas, to enter a vacuum cavity containing a linear ion trap mass spectrometer. The ambient clean zone and the vacuum cavity are connected via a few centimeter long aperture valve ion guide tube. In this paper, we present results from a recently completed numerical investigation of ion transport from the ion source across the ion guide. Specifically, we focus on collisional coupling between ions and the neutral molecules flowing into the vacuum cavity. The simulation domain contains the ambient region, and we consider the variation in ion conductance with ambient pressure. We also analyze the impact of a fixed potential bias applied to the aperture valve. Simulations are performed with a two-dimensional axisymmetric PIC / DSMC code Starfish. Numerical results are compared to experimental data.

Breida, Lubos↗

Polycyclic Aromatic Hydrocarbon Ionization Energy Lowering in Water Ices

In studying various interstellar and solar system ice analogs, we have recently found that upon vacuum ultraviolet photolysis, polycyclic aromatic hydrocarbons (PAHs) frozen in water ice at low temperatures are easily ionized and indefinitely stabilized as trapped ions (Gudipati; Gudipati & Allamandola). Here we report the first experimental study that shows that PAH ionization energy is significantly lowered in PAH/H2O ices, in agreement with recent theoretical work (Woon & Park). The ionization energy (IE) of the PAH studied here, quaterrylene (C40H20, IE = 6.11 eV), is lowered by up to 2.11 eV in water ice. PAH ionization energy reduction in low-temperature water ice substantially expands the astronomical regions in which trapped ions and electrons may be important. This reduction in ionization energy should also hold for other types of trapped species in waterrich interstellar, circumstellar, and solar system ices. Subject headings: ISM: clouds - methods: laboratory - molecular processes - radiation mechanisms: nonthermal -ultraviolet: ISM - ultraviolet: solar system

Gudipati, Murthy S.↗